{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T00:58:41Z","timestamp":1768870721541,"version":"3.49.0"},"reference-count":31,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2020,4,29]],"date-time":"2020-04-29T00:00:00Z","timestamp":1588118400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0232372","type":"journal-article","created":{"date-parts":[[2020,4,29]],"date-time":"2020-04-29T18:42:38Z","timestamp":1588185758000},"page":"e0232372","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":12,"title":["Clinical feasibility of ultrafast intracranial vessel imaging with non-Cartesian spiral 3D time-of-flight MR angiography at 1.5T: An intra-individual comparison study"],"prefix":"10.1371","volume":"15","author":[{"given":"Thomas","family":"Sartoretti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabeth","family":"Sartoretti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u00c1rp\u00e1d","family":"Schwenk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luuk","family":"van Smoorenburg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manoj","family":"Mannil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9","family":"Euler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anton S.","family":"Becker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0209-4114","authenticated-orcid":true,"given":"Alex","family":"Alfieri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5151-4672","authenticated-orcid":true,"given":"Arash","family":"Najafi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph A.","family":"Binkert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Wyss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7156-8945","authenticated-orcid":true,"given":"Sabine","family":"Sartoretti-Schefer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2020,4,29]]},"reference":[{"issue":"6","key":"pone.0232372.ref001","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1002\/jmri.26752","article-title":"Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing","volume":"50","author":"Z Lin","year":"2019","journal-title":"J Magn Reson Imaging"},{"issue":"11","key":"pone.0232372.ref002","doi-asserted-by":"crossref","DOI":"10.1002\/nbm.3774","article-title":"Clinical evaluation of time-of-flight MR angiography with sparse undersampling and iterative reconstruction for cerebral aneurysms","volume":"30","author":"Y Fushimi","year":"2017","journal-title":"NMR Biomed"},{"issue":"4","key":"pone.0232372.ref003","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1097\/RLI.0000000000000226","article-title":"Compressed Sensing 3-Dimensional Time-of-Flight Magnetic Resonance Angiography for Cerebral Aneurysms: Optimization and Evaluation","volume":"51","author":"Y Fushimi","year":"2016","journal-title":"Invest Radiol"},{"issue":"10","key":"pone.0232372.ref004","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.3174\/ajnr.A5786","article-title":"Clinical Evaluation of Highly Accelerated Compressed Sensing Time-of-Flight MR Angiography for Intracranial Arterial Stenosis","volume":"39","author":"SS Lu","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"pone.0232372.ref005","doi-asserted-by":"crossref","first-page":"e0189493","DOI":"10.1371\/journal.pone.0189493","article-title":"Magnetic resonance angiography with compressed sensing: An evaluation of moyamoya disease","volume":"13","author":"T Yamamoto","year":"2018","journal-title":"PLoS One"},{"issue":"6","key":"pone.0232372.ref006","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/RLI.0000000000000221","article-title":"Time-of-Flight Magnetic Resonance Angiography With Sparse Undersampling and Iterative Reconstruction: Comparison With Conventional Parallel Imaging for Accelerated Imaging","volume":"51","author":"T Yamamoto","year":"2016","journal-title":"Invest Radiol"},{"issue":"2","key":"pone.0232372.ref007","doi-asserted-by":"crossref","first-page":"265","DOI":"10.3348\/kjr.2017.0634","article-title":"Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries","volume":"20","author":"H Tang","year":"2019","journal-title":"Korean J Radiol"},{"key":"pone.0232372.ref008","article-title":"Ultrafast Intracranial Vessel Imaging with non-Cartesian Spiral 3D Time-of-flight MR Angiography at 1.5T: An in vitro and clinical study in Healthy Volunteers","author":"T Sartoretti","year":"2019","journal-title":"Invest Radiol"},{"key":"pone.0232372.ref009","article-title":"Highly accelerated time-of-flight magnetic resonance angiography using spiral imaging improves conspicuity of intracranial arterial branches while reducing scan time","author":"T Greve","year":"2019","journal-title":"Eur Radiol"},{"issue":"4","key":"pone.0232372.ref010","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1002\/mrm.1910380414","article-title":"Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays","volume":"38","author":"DK Sodickson","year":"1997","journal-title":"Magn Reson Med"},{"key":"pone.0232372.ref011","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"MA Griswold","year":"2002","journal-title":"Magn Reson Med"},{"issue":"5","key":"pone.0232372.ref012","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"KP Pruessmann","year":"1999","journal-title":"Magn Reson Med"},{"issue":"4","key":"pone.0232372.ref013","doi-asserted-by":"crossref","first-page":"e0214887","DOI":"10.1371\/journal.pone.0214887","article-title":"Reduction of procedure times in routine clinical practice with Compressed SENSE magnetic resonance imaging technique","volume":"14","author":"E Sartoretti","year":"2019","journal-title":"PLoS One"},{"issue":"4","key":"pone.0232372.ref014","doi-asserted-by":"crossref","first-page":"642","DOI":"10.3174\/ajnr.A4600","article-title":"A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo","volume":"37","author":"Z Li","year":"2016","journal-title":"AJNR Am J Neuroradiol"},{"key":"pone.0232372.ref015","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1002\/mrm.1910330414","article-title":"A velocity k-space analysis of flow effects in echo-planar and spiral imaging","volume":"33","author":"DG Nishimura","year":"1995","journal-title":"Magn Reson Med"},{"key":"pone.0232372.ref016","first-page":"247","article-title":"Spiral spin-echo magnetic resonance imaging of the pelvis with spectrally and spatially selective radiofrequency excitation: comparison with fat-saturated fast spin-echo imaging","volume":"48","author":"ME Yacoe","year":"1997","journal-title":"Can Assoc Radiol J"},{"key":"pone.0232372.ref017","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1002\/nbm.1380","article-title":"Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions","volume":"22","author":"KD Brewer","year":"2009","journal-title":"NMR Biomed"},{"issue":"4","key":"pone.0232372.ref018","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1002\/mrm.1258","article-title":"Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography","volume":"46","author":"P B\u00f6rnert","year":"2001","journal-title":"Magn Reson Med"},{"issue":"120","key":"pone.0232372.ref019","doi-asserted-by":"crossref","first-page":"108667","DOI":"10.1016\/j.ejrad.2019.108667","article-title":"Compressed SENSE accelerated 3D T1w black blood Turbo Spin Echo versus 2D T1w Turbo Spin Echo Sequence in Pituitary Magnetic Resonance Imaging","volume":"14","author":"T Sartoretti","year":"2019","journal-title":"Eur J Radiol"},{"issue":"6","key":"pone.0232372.ref020","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1007\/s13244-018-0668-4","article-title":"Common artefacts encountered on images acquired with combined compressed sensing and SENSE","volume":"9","author":"T Sartoretti","year":"2018","journal-title":"Insights Imaging"},{"key":"pone.0232372.ref021","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.ejrad.2019.04.002","article-title":"Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions","volume":"115","author":"FK Loh\u00f6fer","year":"2019","journal-title":"Eur J Radiol"},{"key":"pone.0232372.ref022","doi-asserted-by":"crossref","first-page":"108675","DOI":"10.1016\/j.ejrad.2019.108675","article-title":"Camera-based respiratory triggering improves the image quality of 3D magnetic resonance cholangiopancreatography","volume":"120","author":"F Harder","journal-title":"Eur J Radiol. 2019"},{"issue":"6","key":"pone.0232372.ref023","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1097\/RLI.0000000000000550","article-title":"Acceleration of Double Inversion Recovery Sequences in Multiple Sclerosis With Compressed Sensing","volume":"54","author":"P Eichinger","year":"2019","journal-title":"Invest Radiol"},{"issue":"3","key":"pone.0232372.ref024","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1148\/radiol.2293020782","article-title":"Time-of-flight MR angiography: comparison of 3.0-T imaging and 1.5-T imaging\u2014initial experience","volume":"229","author":"WA Willinek","year":"2003","journal-title":"Radiology"},{"issue":"1","key":"pone.0232372.ref025","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1097\/RLI.0000000000000504","article-title":"Improved Visualization of Juxtaprosthetic Tissue Using Metal Artifact Reduction Magnetic Resonance Imaging: Experimental and Clinical Optimization of Compressed Sensing SEMAC","volume":"54","author":"PM Jungmann","year":"2019","journal-title":"Invest Radiol"},{"key":"pone.0232372.ref026","article-title":"Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction","author":"D Hausmann","year":"2019","journal-title":"Invest Radiol"},{"issue":"6","key":"pone.0232372.ref027","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/RLI.0000000000000548","article-title":"Compressed Sensing and Parallel Imaging for Double Hepatic Arterial Phase Acquisition in Gadoxetate-Enhanced Dynamic Liver Magnetic Resonance Imaging","volume":"54","author":"JK Yoon","year":"2019","journal-title":"Invest Radiol"},{"issue":"11","key":"pone.0232372.ref028","doi-asserted-by":"crossref","first-page":"e0224988","DOI":"10.1371\/journal.pone.0224988","article-title":"Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing","volume":"14","author":"FK Loh\u00f6fer","year":"2019","journal-title":"PLoS One"},{"issue":"7","key":"pone.0232372.ref029","doi-asserted-by":"crossref","first-page":"e0218874","DOI":"10.1371\/journal.pone.0218874","article-title":"Accelerated magnetic resonance imaging tissue phase mapping of the rat myocardium using compressed sensing with iterative soft-thresholding","volume":"14","author":"G McGinley","year":"2019","journal-title":"PLoS One"},{"issue":"1","key":"pone.0232372.ref030","doi-asserted-by":"crossref","first-page":"e0228424","DOI":"10.1371\/journal.pone.0228424","article-title":"Whole body MRI in multiple myeloma: Optimising image acquisition and read times","volume":"15","author":"S Singh","year":"2020","journal-title":"PLoS One"},{"issue":"3","key":"pone.0232372.ref031","doi-asserted-by":"crossref","first-page":"e0213514","DOI":"10.1371\/journal.pone.0213514","article-title":"High-resolution contrast-enhanced vessel wall imaging in patients with suspected cerebral vasculitis: Prospective comparison of whole-brain 3D T1 SPACE versus 2D T1 black blood MRI at 3 Tesla","volume":"14","author":"S Eiden","year":"2019","journal-title":"PLoS One"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0232372","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,30]],"date-time":"2023-09-30T13:15:10Z","timestamp":1696079710000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0232372"}},"subtitle":[],"editor":[{"given":"Pascal A. T.","family":"Baltzer","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,4,29]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,4,29]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0232372","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,29]]}}}