{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T16:52:30Z","timestamp":1790009550531,"version":"4.0.1"},"reference-count":43,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2020,6,11]],"date-time":"2020-06-11T00:00:00Z","timestamp":1591833600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100006438","name":"Office of the Assistant Secretary for Health","doi-asserted-by":"publisher","award":["W81XWH-16-1-0485"],"award-info":[{"award-number":["W81XWH-16-1-0485"]}],"id":[{"id":"10.13039\/100006438","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009157","name":"National Institute on Disability, Independent Living, and Rehabilitation Research","doi-asserted-by":"publisher","award":["90AR5010 and 90AR5031"],"award-info":[{"award-number":["90AR5010 and 90AR5031"]}],"id":[{"id":"10.13039\/100009157","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0233148","type":"journal-article","created":{"date-parts":[[2020,6,11]],"date-time":"2020-06-11T17:37:44Z","timestamp":1591897064000},"page":"e0233148","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":13,"title":["Using mechanical testing to assess texturing of prosthetic sockets to improve suspension in the transverse plane and reduce rotation"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9089-7322","authenticated-orcid":true,"given":"Julia","family":"Quinlan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasanth","family":"Subramanian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Yohay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brad","family":"Poziembo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefania","family":"Fatone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2020,6,11]]},"reference":[{"issue":"2","key":"pone.0233148.ref001","first-page":"161","article-title":"State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review","volume":"38","author":"A Mak","year":"2001","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"pone.0233148.ref002","first-page":"155","article-title":"Issues of importance reported by persons with lower limb amputations and prostheses","volume":"36","author":"M Legro","year":"1999","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"pone.0233148.ref003","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/S0190-9622(00)90227-5","article-title":"Skin disorders in amputees","volume":"42","author":"C Lyon","year":"2000","journal-title":"J Am Acad Dermatol"},{"issue":"1","key":"pone.0233148.ref004","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.apmr.2008.07.015","article-title":"Determinants of skin problems of the stump in lower-limb amputees","volume":"90","author":"H Meulenbelt","year":"2009","journal-title":"Arch Phys Med Rehabil"},{"key":"pone.0233148.ref005","doi-asserted-by":"crossref","first-page":"2804","DOI":"10.1016\/j.wear.2011.05.032","article-title":"Effect of prosthetic socks on the frictional properties of residual limb skin","volume":"271","author":"W Li","year":"2011","journal-title":"Wear"},{"issue":"1","key":"pone.0233148.ref006","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1682\/JRRD.2003.01.0009","article-title":"Transverse rotation and longitudinal translation during prosthetic gait-a literature review","volume":"40","author":"M Twiste","year":"2003","journal-title":"J Rehabil Res Dev"},{"issue":"5","key":"pone.0233148.ref007","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1177\/0309364615592698","article-title":"Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns","volume":"40","author":"D Heitzmann","year":"2016","journal-title":"Prosthet Orthot Int"},{"key":"pone.0233148.ref008","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.gaitpost.2018.06.119","article-title":"The effect of transverse prosthetic alignment changes on socket reaction moments during gait in individuals with transtibial amputation","volume":"65","author":"H Hashimoto","year":"2018","journal-title":"Gait Posture"},{"issue":"1","key":"pone.0233148.ref009","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1177\/0309364616631343","article-title":"User experience of transtibial prosthetic liners: A systematic review","volume":"41","author":"A Richardson","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"pone.0233148.ref010","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1475-925X-13-1","article-title":"Evaluation of new suspension system for limb prosthetics","volume":"13","author":"H Gholizadeh","year":"2014","journal-title":"Biomed Eng Online"},{"issue":"11","key":"pone.0233148.ref011","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.1016\/j.apmr.2012.04.024","article-title":"Qualitative study of prosthetic suspension systems on transtibial amputees\u2019 satisfaction and perceived problems with their prosthetic devices","volume":"93","author":"S Ali","year":"2012","journal-title":"Arch Phys Med Rehabil"},{"issue":"12","key":"pone.0233148.ref012","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1097\/PHM.0b013e318269d82a","article-title":"Quantitative and qualitative comparison of a new prosthetic suspension system with two existing suspension systems for lower limb amputees","volume":"91","author":"A Eshraghi","year":"2012","journal-title":"Am J Phys Med Rehabil"},{"key":"pone.0233148.ref013","doi-asserted-by":"crossref","unstructured":"Chui K, Jorge M, Yen S-C, Lusardi M. Orthotics and Prosthetics in Rehabilitation E-Book: Elsevier Health Sciences; 2019.","DOI":"10.1016\/B978-0-323-60913-5.00001-5"},{"issue":"3","key":"pone.0233148.ref014","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1682\/JRRD.2008.06.0070","article-title":"Transtibial amputee joint rotation moments during straight-line walking and a common turning task with and without a torsion adapter","volume":"46","author":"A Segal","year":"2009","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"pone.0233148.ref015","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1177\/0309364613497048","article-title":"Use of a load cell and force-moment curves to compare transverse plane moment loads on transtibial residual limbs: A preliminary investigation","volume":"38","author":"E Neumann","year":"2014","journal-title":"Prosthet Orthot Int"},{"key":"pone.0233148.ref016","article-title":"Ideal operating conditions for a variable stiffness transverse plane adapter for individuals with lower-limb amputation","volume":"96","author":"C Pew","year":"2019","journal-title":"J Biomech"},{"issue":"1","key":"pone.0233148.ref017","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1080\/03093640500088120","article-title":"Comparison of human turning gait with the mechanical performance of lower limb prosthetic transverse rotation adapters","volume":"29","author":"K Flick","year":"2005","journal-title":"Prosthet Orthot Int"},{"key":"pone.0233148.ref018","unstructured":"Caspers C, inventor; Carl Caspers Consulting LLC, assignee. Dynamically-activated variable response socket with hydraulic pump. USA patent US 8114167B2. 2010 Jul 5."},{"key":"pone.0233148.ref019","volume-title":"The effect of vacuum level and socket wall texture on maximal static friction between a cloth sheath and socket wall material","author":"J Castellano","year":"2011"},{"issue":"S1","key":"pone.0233148.ref020","first-page":"39","article-title":"Mechanical testing of textured prosthetic sockets provides insight on improving suspension","volume":"30","author":"J Quinlan","year":"2018","journal-title":"J Prosthet Orthot"},{"issue":"S2","key":"pone.0233148.ref021","first-page":"32","article-title":"Tensile and coefficient of friction testing of textured prosthetic socket specimens provide insights on strength and friction","volume":"31","author":"J Quinlan","year":"2019","journal-title":"J Prosthet Orthot"},{"key":"pone.0233148.ref022","unstructured":"Rovick J. An additive fabrication technique for the computer-aided manufacturing of sockets. 7th World Congress of the International Society for Prosthetics and Orthotics (ISPO); 28 June-3 July 1992; Chicago, Illinois, USA: ISPO; 1992. p. 24."},{"key":"pone.0233148.ref023","volume-title":"Automated Fabrication of Sockets for Artificial Limbs","author":"J Rovick","year":"1993"},{"key":"pone.0233148.ref024","unstructured":"ASTM. D1894-14. Standard test method for static and kinetic coefficients of friction of plastic film and sheeting."},{"key":"pone.0233148.ref025","unstructured":"ISO. 10328:2016. Prosthetics\u2014Structural testing of lower-limb prostheses\u2014Requirements and test methods."},{"issue":"2","key":"pone.0233148.ref026","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3109\/03093649909071622","article-title":"Static structural testing of trans-tibial composite sockets","volume":"23","author":"T Current","year":"1999","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"pone.0233148.ref027","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1080\/03093640008726554","article-title":"Principal structural testing of trans-tibial prosthetic assemblies: specimen preparation","volume":"24","author":"L Neo","year":"2000","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"pone.0233148.ref028","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/JPO.0b013e3180cfe8da","article-title":"Relative Strength of Pylon-to-Socket Attachment Systems Used in Transtibial Composite Sockets","volume":"19","author":"R Graebner","year":"2007","journal-title":"J Prosthet Orthot"},{"issue":"3","key":"pone.0233148.ref029","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1682\/JRRD.2011.05.0091","article-title":"Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets","volume":"49","author":"M Gerschutz","year":"2012","journal-title":"J Rehabil Res Dev"},{"issue":"7","key":"pone.0233148.ref030","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1089\/wound.2016.0719","article-title":"Progress toward optimizing prosthetic socket fit and suspension using elevated vacuum to promote residual limb health","volume":"6","author":"M Wernke","year":"2017","journal-title":"Adv Wound Care (New Rochelle)"},{"issue":"3","key":"pone.0233148.ref031","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1177\/0954411917690764","article-title":"Development of a residuum\/socket interface simulator for lower limb prosthetics","volume":"231","author":"M McGrath","year":"2017","journal-title":"Proc Inst Mech Eng H"},{"issue":"9","key":"pone.0233148.ref032","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1177\/0954411912452996","article-title":"A linear-actuated torsional device to replicate clinically relevant spiral fractures in long bones","volume":"226","author":"W Edwards","year":"2012","journal-title":"Proc Inst Mech Eng H"},{"key":"pone.0233148.ref033","unstructured":"Instron. 8800 Series load frames using console 8.2 onwards. Operating instructions manual. M21-15041-EN Revision E. www.instron.com. p. 1\u20133."},{"issue":"2","key":"pone.0233148.ref034","doi-asserted-by":"crossref","first-page":"114","DOI":"10.3109\/03093647709164619","article-title":"Functional analysis of the UC-BL shank axial rotation device","volume":"1","author":"L Lamoureux","year":"1977","journal-title":"Prosthet Orthot Int"},{"issue":"9","key":"pone.0233148.ref035","doi-asserted-by":"crossref","DOI":"10.1115\/1.4040125","article-title":"Understanding displacements of the gel liner for below knee prosthetic users","volume":"140","author":"A Lenz","year":"2018","journal-title":"J Biomech Eng"},{"issue":"4","key":"pone.0233148.ref036","doi-asserted-by":"crossref","DOI":"10.1115\/1.4035917","article-title":"Development of standardized material testing protocols for prosthetic liners","volume":"139","author":"J Cagle","year":"2017","journal-title":"J Biomech Eng"},{"issue":"1","key":"pone.0233148.ref037","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00008526-200012010-00007","article-title":"Flow constraint and loading rate effects on prosthetic liner material and human tissue mechanical response","volume":"12","author":"S Covey","year":"2000","journal-title":"J Prosthet Orthot"},{"issue":"1","key":"pone.0233148.ref038","first-page":"41","article-title":"A two-step approach for transforming continuous variables to normal: Implications and recommendations for IS research","volume":"28","author":"G Templeton","year":"2011","journal-title":"CAIS"},{"issue":"1","key":"pone.0233148.ref039","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.gaitpost.2010.09.021","article-title":"Comparison of transtibial amputee and non-amputee biomechanics during a common turning task","volume":"33","author":"A Segal","year":"2011","journal-title":"Gait Posture"},{"issue":"1","key":"pone.0233148.ref040","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1080\/03093640208726619","article-title":"The biomechanical effects of the inclusion of a torque absorber on trans-femoral amputee gait, a pilot study","volume":"26","author":"M Van der Linden","year":"2002","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"pone.0233148.ref041","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.gaitpost.2011.05.014","article-title":"Compensatory mechanisms of transtibial amputees during circular turning","volume":"34","author":"J Ventura","year":"2011","journal-title":"Gait Posture"},{"issue":"3","key":"pone.0233148.ref042","first-page":"1","article-title":"Biomechanical modeling of human skin tissue surrogates","volume":"3","author":"A Chanda","year":"2018","journal-title":"Biomimetics (Basel, Switzerland)"},{"key":"pone.0233148.ref043","unstructured":"Trotta T, Trotta J, Lowe S, inventors; Gaumard Scientific Co Inc, assignee. Human tissue models, materials, and methods. United States patent US 20130192741A1. 2013 Aug 1."}],"updated-by":[{"DOI":"10.1371\/journal.pone.0269580","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,6,2]],"date-time":"2022-06-02T00:00:00Z","timestamp":1654128000000}}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0233148","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,20]],"date-time":"2021-03-20T00:04:08Z","timestamp":1616198648000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0233148"}},"subtitle":[],"editor":[{"given":"Yih-Kuen","family":"Jan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2020,6,11]]},"references-count":43,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,6,11]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0233148","relation":{"correction":[{"id-type":"doi","id":"10.1371\/journal.pone.0269580","asserted-by":"object"}]},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,11]]}}}