{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T01:14:20Z","timestamp":1790990060201,"version":"4.1.0"},"reference-count":44,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2020,5,14]],"date-time":"2020-05-14T00:00:00Z","timestamp":1589414400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Biotecnos"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The propose was to compare this new implant macrogeometry with a control implant with a conventional macrogeometry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Eighty-six conical implants were divided in two groups (n = 43 per group): group control (group CON) that were used conical implants with a conventional macrogeometry and, group test (group TEST) that were used implants with the new macrogeometry. The new implant macrogeometry show several circular healing cambers between the threads, distributed in the implant body. Three implants of each group were used to scanning electronic microscopy (SEM) analysis and, other eighty samples (n = 40 per group) were inserted the tibia of ten rabbit (n = 2 per tibia), determined by randomization. The animals were sacrificed (n = 5 per time) at 3-weeks (Time 1) and at 4-weeks after the implantations (Time 2). The biomechanical evaluation proposed was the measurement of the implant stability quotient (ISQ) and the removal torque values (RTv). The microscopical analysis was a histomorphometric measurement of the bone to implant contact (%BIC) and the SEM evaluation of the bone adhered on the removed implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The results showed that the implants of the group TEST produced a significant enhancement in the osseointegration in comparison with the group CON. The ISQ and RTv tests showed superior values for the group TEST in the both measured times (3- and 4-weeks), with significant differences (p &lt; 0.05). More residual bone in quantity and quality was observed in the samples of the group TEST on the surface of the removed implants. Moreover, the %BIC demonstrated an important increasing for the group TEST in both times, with statistical differences (in Time 1\n                      <jats:italic>p<\/jats:italic>\n                      = 0.0103 and in Time 2\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.0003).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Then, we can conclude that the alterations in the implant macrogeometry promote several benefits on the osseointegration process.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0233304","type":"journal-article","created":{"date-parts":[[2020,5,14]],"date-time":"2020-05-14T17:24:11Z","timestamp":1589477051000},"page":"e0233304","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":22,"title":["RETRACTED: Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5863-9101","authenticated-orcid":true,"given":"Sergio Alexandre","family":"Gehrke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaime","family":"Arambur\u00fa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leticia","family":"P\u00e9rez-D\u00edaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tales Dias","family":"do Prado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3995-4747","authenticated-orcid":true,"given":"Berenice Anina","family":"Dedavid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"Mazon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piedad","family":"N. De Aza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2020,5,14]]},"reference":[{"issue":"6","key":"pone.0233304.ref001","doi-asserted-by":"crossref","DOI":"10.3390\/ma12060856","article-title":"Biomechanical and Histological Analysis of Titanium (Machined and Treated Surface) Versus Zirconia Implant Materials: An In Vivo Animal Study","volume":"12","author":"SA Gehrke","year":"2019","journal-title":"Materials (Basel)"},{"key":"pone.0233304.ref002","doi-asserted-by":"crossref","first-page":"170","DOI":"10.3389\/fbioe.2019.00170","article-title":"Titanium-Tissue Interface Reaction and Its Control With Surface Treatment","volume":"7","author":"T Hanawa","year":"2019","journal-title":"Front Bioeng Biotechnol"},{"issue":"2","key":"pone.0233304.ref003","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.dental.2014.10.002","article-title":"Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants","volume":"31","author":"CN Elias","year":"2015","journal-title":"Dent Mater"},{"key":"pone.0233304.ref004","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1111\/clr.13145","article-title":"Marginal bone loss at implants with different surface characteristics\u2014A 20-year follow-up of a randomized controlled clinical trial","volume":"29","author":"M Donati","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"pone.0233304.ref005","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jdent.2019.03.008","article-title":"Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis","volume":"84","author":"MS Howe","year":"2019","journal-title":"J Dent"},{"issue":"1","key":"pone.0233304.ref006","doi-asserted-by":"crossref","DOI":"10.3390\/jfb9010007","article-title":"Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV) Bone: An Overview","volume":"9","author":"HS Alghamdi","year":"2018","journal-title":"J Funct Biomater"},{"key":"pone.0233304.ref007","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1590\/0103-6440201601559","article-title":"Accelerated Healing Period with Hydrophilic Implant Placed in Sheep Tibia","volume":"28","author":"SC Sartoretto","year":"2017","journal-title":"Braz Dent J"},{"key":"pone.0233304.ref008","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/4265474","article-title":"Effect of Different Morphology of Titanium Surface on the Bone Healing in Defects Filled Only with Blood Clot: A New Animal Study Design","volume":"2018","author":"SA Gehrke","year":"2018","journal-title":"Biomed Res Int"},{"key":"pone.0233304.ref009","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.micron.2017.11.010","article-title":"Osteoblastic cell behaviour on modified titanium surfaces","volume":"105","author":"M Lukaszewska-Kuska","year":"2018","journal-title":"Micron"},{"key":"pone.0233304.ref010","doi-asserted-by":"crossref","first-page":"e12349","DOI":"10.1111\/jicd.12349","article-title":"Novel surfaces and osseointegration in implant dentistry","volume":"9","author":"G Pellegrini","year":"2018","journal-title":"J Investig Clin Dent"},{"key":"pone.0233304.ref011","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1016\/j.jmbbm.2011.06.016","article-title":"The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs","volume":"4","author":"PG Coelho","year":"2011","journal-title":"J Mech Behav Biomed Mater"},{"issue":"6","key":"pone.0233304.ref012","doi-asserted-by":"crossref","DOI":"10.3390\/jcm8060777","article-title":"Impact of Different Titanium Implant Thread Designs on Bone Healing: A Biomechanical and Histometric Study with an Animal Model","volume":"8","author":"SA Gehrke","year":"2019","journal-title":"J Clin Med"},{"issue":"6","key":"pone.0233304.ref013","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1111\/j.1708-8208.2011.00431.x","article-title":"Biomechanical and bone histomorphological evaluation of two surfaces on tapered and cylindrical root form implants: an experimental study in dogs","volume":"15","author":"B Negri","year":"2013","journal-title":"Clin Implant Dent Relat Res"},{"key":"pone.0233304.ref014","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1111\/j.1708-8208.2009.00202.x","article-title":"The effects of superficial roughness and design on the primary stability of dental implants","volume":"13","author":"MV Dos Santos","year":"2011","journal-title":"Clin Implant Dent Relat Res"},{"key":"pone.0233304.ref015","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1111\/clr.12909","article-title":"Effects on the osseointegration of titanium implants incorporating calcium-magnesium: a resonance frequency and histomorphometric analysis in rabbit tibia","volume":"29","author":"SA Gehrke","year":"2018","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"pone.0233304.ref016","doi-asserted-by":"crossref","DOI":"10.3390\/ma12050840","article-title":"In Vitro Assessment of the Functional Dynamics of Titanium with Surface Coating of Hydroxyapatite Nanoparticles","volume":"12","author":"JH de Lima Cavalcanti","year":"2019","journal-title":"Materials (Basel)"},{"key":"pone.0233304.ref017","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1097\/SCS.0000000000001788","article-title":"Evaluation of the Cortical Bone Reaction Around of Implants Using a Single-Use Final Drill: A Histologic Study","volume":"26","author":"SA Gehrke","year":"2015","journal-title":"J Craniofac Surg"},{"key":"pone.0233304.ref018","doi-asserted-by":"crossref","first-page":"780","DOI":"10.11607\/jomi.5871","article-title":"Impact of Surface Chemistry Modifications on Speed and Strength of Osseointegration","volume":"33","author":"HG Kang","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"key":"pone.0233304.ref019","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/6285620","article-title":"Impact of Dental Implant Surface Modifications on Osseointegration","volume":"2016","author":"R Smeets","year":"2016","journal-title":"Biomed Res Int"},{"key":"pone.0233304.ref020","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.cden.2014.12.003","article-title":"Implant surface material, design, and osseointegration","volume":"59","author":"OE Ogle","year":"2015","journal-title":"Dent Clin North Am"},{"key":"pone.0233304.ref021","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1111\/j.1600-0501.2008.01692.x","article-title":"Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: A laboratory study","volume":"20","author":"A Tabassum","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"pone.0233304.ref022","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1177\/0022034514566029","article-title":"Multiscale Analyses of the Bone\u2010implant Interface","volume":"94","author":"JY Cha","year":"2015","journal-title":"J Dent Res"},{"key":"pone.0233304.ref023","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1902\/jop.2009.080581","article-title":"Implant compression necrosis: current understanding and case report","volume":"80","author":"JD Bashutski","year":"2009","journal-title":"J Periodontol"},{"key":"pone.0233304.ref024","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1111\/clr.12180","article-title":"Evaluation of primary and secondary stability of titanium implants using different surgical techniques","volume":"25","author":"A Tabassum","year":"2014","journal-title":"Clin Oral Implants Res"},{"key":"pone.0233304.ref025","doi-asserted-by":"crossref","first-page":"e43","DOI":"10.1016\/j.joms.2011.08.006","article-title":"Effect of drilling dimension on implant placement torque and early osseointegration stages: an experimental study in dogs","volume":"70","author":"FE Campos","year":"2012","journal-title":"J Oral Maxillofac Surg"},{"key":"pone.0233304.ref026","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.ijom.2014.03.017","article-title":"The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental study","volume":"43","author":"R Jimbo","year":"2014","journal-title":"Int J Oral Maxillof Surg"},{"key":"pone.0233304.ref027","article-title":"Is there a need for standardization of tightening force used to connect the transducer for resonance frequency analysis in determining implant stability?","author":"DB Salatti","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"8","key":"pone.0233304.ref028","doi-asserted-by":"crossref","DOI":"10.3390\/ma12081287","article-title":"Microgrooves and Microrugosities in Titanium Implant Surfaces: An In Vitro and In Vivo Evaluation","volume":"12","author":"SA Gehrke","year":"2019","journal-title":"Materials (Basel)"},{"key":"pone.0233304.ref029","doi-asserted-by":"crossref","first-page":"203","DOI":"10.2147\/CCIDE.S174895","article-title":"The effect of implant placement torque on crestal bone remodeling after 1 year of loading","volume":"9","author":"S Aldahlawi","year":"2018","journal-title":"Clin Cosmet Investig Dent"},{"key":"pone.0233304.ref030","first-page":"837","article-title":"High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible","volume":"26","author":"P Trisi","year":"2011","journal-title":"Int J Oral Maxillofac Implants"},{"key":"pone.0233304.ref031","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1615\/JLongTermEffMedImplants.2015012034","article-title":"High Insertion Torque and Peri-Implant Bone Loss: Is There a Relationship?","volume":"25","author":"M Bidgoli","year":"2015","journal-title":"J Long Term Eff Med Implants"},{"key":"pone.0233304.ref032","first-page":"1193","article-title":"Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias","volume":"26","author":"ACG de Souza Carvalho","year":"2011","journal-title":"Int J Oral Maxillofac Implants"},{"key":"pone.0233304.ref033","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1177\/154405910208100814","article-title":"Risk factors for dental implant failure: A strategy for the analysis of clustered failure-time observations","volume":"81","author":"SK Chuang","year":"2002","journal-title":"J Dent Res"},{"key":"pone.0233304.ref034","first-page":"544","article-title":"Immediate occlusal loading of Osseotite implants in the completely edentulous mandible","volume":"18","author":"T Testori","year":"2003","journal-title":"Int J Oral Maxillofac Implants"},{"key":"pone.0233304.ref035","first-page":"787","article-title":"Immediate non-occlusal loading vs early loading in partially edentulous patients","volume":"15","author":"T Testori","year":"2003","journal-title":"Pract Proced Aesthet Dent"},{"issue":"12","key":"pone.0233304.ref036","doi-asserted-by":"crossref","DOI":"10.3390\/ma11122532","article-title":"Analysis of Trauma Intensity during Surgical Bone Procedures Using NF-\u03baB Expression Levels as a Stress Sensor: An Experimental Study in a Wistar Rat Model","volume":"11","author":"MB Salles","year":"2018","journal-title":"Materials (Basel)"},{"key":"pone.0233304.ref037","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1111\/cid.12000","article-title":"Implant stability and bone remodeling after 3 and 13 days of implantation with an initial static strain","volume":"16","author":"A Halldin","year":"2014","journal-title":"Clin Implant Dent Relat Res"},{"key":"pone.0233304.ref038","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1902\/jop.2009.080484","article-title":"Osteocyte density in the peri-implant bone of immediately loaded and submerged dental implants","volume":"80","author":"RR Barros","year":"2009","journal-title":"J Periodontol"},{"key":"pone.0233304.ref039","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/j.1708-8208.2000.tb00110.x","article-title":"Measurements comparing the initial stability of five designs of dental implants: A human cadaver study","volume":"2","author":"D O\u2019Sullivan","year":"2000","journal-title":"Clin Implant Dent Relat Res"},{"key":"pone.0233304.ref040","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1034\/j.1600-0501.1997.080406.x","article-title":"A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: Preliminary report","volume":"8","author":"A Niimi","year":"1997","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"pone.0233304.ref041","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.dental.2014.10.007","article-title":"Osseointegration: hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales","volume":"31","author":"PG Coelho","year":"2015","journal-title":"Dental Materials"},{"issue":"3","key":"pone.0233304.ref042","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1111\/j.1600-0501.2008.01640.x","article-title":"A study of the bone healing kinetics of plateau versus screw root design titanium dental implants","volume":"20","author":"G Leonard","year":"2009","journal-title":"Clinical Oral Implants Research"},{"key":"pone.0233304.ref043","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1111\/j.1600-0501.2009.01853.x","article-title":"Histomorphologic and histomorphometric evaluation of various endosseous implant healing chamber configurations at early implantation times: a study in dogs","volume":"21","author":"C Marin","year":"2010","journal-title":"Clin Oral Implants Res"},{"issue":"Suppl 2","key":"pone.0233304.ref044","doi-asserted-by":"crossref","first-page":"S81","DOI":"10.1016\/j.parkreldis.2008.04.003","article-title":"Thoughts on limitations of animal models","volume":"14","author":"T Hartung","year":"2008","journal-title":"Parkinsonism Relat Disord"}],"updated-by":[{"DOI":"10.1371\/journal.pone.0355242","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:00:00Z","timestamp":1785801600000}}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0233304","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T17:38:36Z","timestamp":1785865116000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0233304"}},"subtitle":[],"editor":[{"given":"Mar\u00eda Angeles","family":"P\u00e9rez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2020,5,14]]},"references-count":44,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2020,5,14]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0233304","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,14]]}}}