{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T04:08:15Z","timestamp":1768709295901,"version":"3.49.0"},"reference-count":51,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T00:00:00Z","timestamp":1593129600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/publicdomain\/zero\/1.0\/"}],"funder":[{"DOI":"10.13039\/100004440","name":"Wellcome Trust","doi-asserted-by":"publisher","award":["106946"],"award-info":[{"award-number":["106946"]}],"id":[{"id":"10.13039\/100004440","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013373","name":"NIHR Oxford Biomedical Research Centre","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100013373","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0234982","type":"journal-article","created":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T20:23:05Z","timestamp":1593202985000},"page":"e0234982","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":11,"title":["Histological evaluation of cellular response to a multifilament electrospun suture for tendon repair"],"prefix":"10.1371","volume":"15","author":[{"given":"Mustafa","family":"Rashid","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jayesh","family":"Dudhia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie G.","family":"Dakin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Snelling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonina","family":"Lach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0037-5286","authenticated-orcid":true,"given":"Roberta","family":"De Godoy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1192-6362","authenticated-orcid":true,"given":"Pierre-Alexis","family":"Mouthuy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roger","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Morrey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew J.","family":"Carr","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2020,6,26]]},"reference":[{"issue":"4","key":"pone.0234982.ref001","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/S1058-2746(99)90148-9","article-title":"Age-related prevalence of rotator cuff tears in asymptomatic shoulders","volume":"8","author":"SR Tempelhof","year":"1999","journal-title":"Journal of Shoulder and Elbow Surgery"},{"issue":"21","key":"pone.0234982.ref002","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.2106\/JBJS.N.01051","article-title":"Treatment of Nontraumatic Rotator Cuff Tears: A Randomized Controlled Trial with Two Years of Clinical and Imaging Follow-up.","volume":"97","author":"J Kukkonen","year":"2015","journal-title":"J Bone Joint Surg Am"},{"key":"pone.0234982.ref003","unstructured":"NHS. Hospital Admitted Patient Care Activity, 2015\u20132016 [National statistics]. Hospital Episodes Statistics Online. 2016 [Available from: https:\/\/digital.nhs.uk\/data-and-information\/publications\/statistical\/hospital-admitted-patient-care-activity\/2015-16."},{"issue":"1","key":"pone.0234982.ref004","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1302\/0301-620X.47B1.36","article-title":"Repair of ruptures of the rotator cuff of the shoulder","volume":"47-B","author":"PD Debeyre J","year":"1965","journal-title":"Journal of Bone and Joint Surgery"},{"issue":"6","key":"pone.0234982.ref005","doi-asserted-by":"crossref","first-page":"e1297","DOI":"10.1016\/j.eats.2016.07.022","article-title":"Arthroscopic Rotator Cuff Repair: Double-Row Transosseous Equivalent Suture Bridge Technique.","volume":"5","author":"M Abdelshahed","year":"2016","journal-title":"Arthrosc Tech."},{"issue":"3","key":"pone.0234982.ref006","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.arthro.2009.07.009","article-title":"The geometric classification of rotator cuff tears: a system linking tear pattern to treatment and prognosis.","volume":"26","author":"J Davidson","year":"2010","journal-title":"Arthroscopy"},{"key":"pone.0234982.ref007","first-page":"363546517728718","article-title":"Arthroscopic Single-Row Versus Double-Row Suture Bridge Technique for Rotator Cuff Tears in Patients Younger Than 55 Years: A Prospective Comparative Study.","author":"ME Hantes","year":"2017","journal-title":"Am J Sports Med."},{"issue":"10","key":"pone.0234982.ref008","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1177\/0363546513497565","article-title":"Stress distribution within rotator cuff tendons with a crescent-shaped and an L-shaped tear.","volume":"41","author":"H Sano","year":"2013","journal-title":"Am J Sports Med"},{"issue":"9","key":"pone.0234982.ref009","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.arthro.2017.04.003","article-title":"Functional Outcome and Healing of Large and Massive Rotator Cuff Tears Repaired With a Load-Sharing Rip-Stop Construct.","volume":"33","author":"MP Noyes","year":"2017","journal-title":"Arthroscopy"},{"key":"pone.0234982.ref010","first-page":"1","article-title":"Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.","author":"MS Rashid","year":"2017","journal-title":"Acta Orthop."},{"issue":"1","key":"pone.0234982.ref011","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0424.R1","article-title":"Effectiveness of open and arthroscopic rotator cuff repair (UKUFF): a randomised controlled trial.","volume":"99-b","author":"A Carr","year":"2017","journal-title":"Bone Joint J"},{"issue":"3","key":"pone.0234982.ref012","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1177\/0363546516652900","article-title":"The Clinical Effect of a Rotator Cuff Retear: A Meta-analysis of Arthroscopic Single-Row and Double-Row Repairs.","volume":"45","author":"J Yang","year":"2017","journal-title":"Am J Sports Med."},{"issue":"9","key":"pone.0234982.ref013","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1007\/s00167-011-1436-x","article-title":"Biomechanical evaluation of four different transosseous-equivalent\/suture bridge rotator cuff repairs.","volume":"19","author":"M Maguire","year":"2011","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"9","key":"pone.0234982.ref014","first-page":"674","article-title":"Evaluation of High-Strength Orthopedic Sutures: A Head-to-Head Comparison.","volume":"33","author":"FJ Miller T","year":"2010","journal-title":"Orthopaedics"},{"key":"pone.0234982.ref015","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0268-0033(99)00095-9","article-title":"Mechanical properties of the posterior rotator cuff.","volume":"15","author":"ZM Halder A","year":"2000","journal-title":"Clinical Biomechanics"},{"issue":"Suppl 1","key":"pone.0234982.ref016","doi-asserted-by":"crossref","first-page":"S14","DOI":"10.1016\/j.jor.2015.01.025","article-title":"Braided tape suture provides superior bone pull-through strength than wire suture in greater tuberosity of the humerus","volume":"12","author":"B Leger St-Jean","year":"2015","journal-title":"J Orthop"},{"issue":"4","key":"pone.0234982.ref017","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jse.2015.09.002","article-title":"A 3D finite element model for geometrical and mechanical comparison of different supraspinatus repair techniques.","volume":"25","author":"M Mantovani","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"issue":"2","key":"pone.0234982.ref018","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1177\/0363546513516602","article-title":"Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.","volume":"42","author":"SS Burkhart","year":"2014","journal-title":"Am J Sports Med"},{"issue":"12","key":"pone.0234982.ref019","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1016\/j.arthro.2014.06.018","article-title":"Abrasive properties of braided polyblend sutures in cuff tendon repair: an in vitro biomechanical study exploring regular and tape sutures.","volume":"30","author":"J Deranlot","year":"2014","journal-title":"Arthroscopy"},{"issue":"6","key":"pone.0234982.ref020","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1007\/s00776-012-0275-z","article-title":"The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.","volume":"17","author":"A De Carli","year":"2012","journal-title":"J Orthop Sci."},{"issue":"4","key":"pone.0234982.ref021","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1111\/os.12139","article-title":"Arthroscopic single-row versus double-row technique for repairing rotator cuff tears: a systematic review and meta-analysis.","volume":"6","author":"ZM Ying","year":"2014","journal-title":"Orthop Surg"},{"issue":"14","key":"pone.0234982.ref022","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.2106\/JBJS.K.00999","article-title":"A multicenter randomized controlled trial comparing single-row with double-row fixation in arthroscopic rotator cuff repair","volume":"94","author":"PL Lapner","year":"2012","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"pone.0234982.ref023","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1177\/0363546508328115","article-title":"A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: magnetic resonance imaging and early clinical evaluation.","volume":"37","author":"RT Burks","year":"2009","journal-title":"Am J Sports Med"},{"issue":"2","key":"pone.0234982.ref024","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1067\/mse.2003.21","article-title":"Mode of failure for rotator cuff repair with suture anchors identified at revision surgery","volume":"12","author":"CA Cummins","year":"2003","journal-title":"J Shoulder Elbow Surg"},{"issue":"4","key":"pone.0234982.ref025","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1177\/0363546509350081","article-title":"Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique.","volume":"38","author":"NS Cho","year":"2010","journal-title":"Am J Sports Med"},{"issue":"1","key":"pone.0234982.ref026","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.jse.2015.07.018","article-title":"Abrasiveness of high-strength sutures used in rotator cuff surgery: are they all the same?","volume":"25","author":"JF Williams","year":"2016","journal-title":"J Shoulder Elbow Surg."},{"issue":"2","key":"pone.0234982.ref027","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1002\/jbm.a.35911","article-title":"Cell response to sterilized electrospun poly(varepsilon-caprolactone) scaffolds to aid tendon regeneration in vivo.","volume":"105","author":"P Bhaskar","year":"2017","journal-title":"J Biomed Mater Res A"},{"issue":"2","key":"pone.0234982.ref028","doi-asserted-by":"crossref","first-page":"025006","DOI":"10.1088\/1758-5090\/7\/2\/025006","article-title":"Fabrication of continuous electrospun filaments with potential for use as medical fibres.","volume":"7","author":"PA Mouthuy","year":"2015","journal-title":"Biofabrication"},{"issue":"9\u201310","key":"pone.0234982.ref029","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1089\/ten.tea.2016.0319","article-title":"Braided and Stacked Electrospun Nanofibrous Scaffolds for Tendon and Ligament Tissue Engineering.","volume":"23","author":"BB Rothrauff","year":"2017","journal-title":"Tissue Eng Part A"},{"key":"pone.0234982.ref030","article-title":"Resorbable electrospun polydioxanone fibres modify the behaviour of cells from both healthy and diseased human tendons","author":"A Kendal","year":"2017","journal-title":"Eur Cell Mater"},{"issue":"1","key":"pone.0234982.ref031","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1186\/s13287-018-0900-7","article-title":"Bone marrow mesenchymal stem cells do not enhance intra-synovial tendon healing despite engraftment and homing to niches with the synovium.","volume":"9","author":"MR Khan","year":"2018","journal-title":"Stem Cell Research & Therapy."},{"key":"pone.0234982.ref032","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.polymertesting.2018.05.014","article-title":"Using an industrial braiding machine to upscale the production and modulate the design of electrospun medical yarns","volume":"69","author":"RE Abhari","year":"2018","journal-title":"Polymer Testing"},{"issue":"7","key":"pone.0234982.ref033","doi-asserted-by":"crossref","first-page":"1788","DOI":"10.1097\/00006534-199712000-00023","article-title":"Tissue response to suture materials implanted subcutaneously in a rabbit model","volume":"100","author":"G Setzen","year":"1997","journal-title":"Plastic and reconstructive surgery"},{"key":"pone.0234982.ref034","first-page":"295","volume-title":"15\u2014Multifilament electrospun scaffolds for soft tissue reconstruction.","author":"RE Abhari","year":"2018"},{"key":"pone.0234982.ref035","first-page":"360","volume-title":"Burn dressings.Biomaterial Science.","author":"JB Kane","year":"1996"},{"key":"pone.0234982.ref036","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.actbio.2015.08.007","article-title":"A layered electrospun and woven surgical scaffold to enhance endogenous tendon repair.","volume":"26","author":"O Hakimi","year":"2015","journal-title":"Acta biomaterialia."},{"issue":"3","key":"pone.0234982.ref037","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1089\/ten.teb.2008.0619","article-title":"Degradation Behaviors of Electrospun Resorbable Polyester Nanofibers","volume":"15","year":"2009","journal-title":"Tissue Engineering Part B: Reviews."},{"issue":"12","key":"pone.0234982.ref038","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1016\/j.arthro.2012.05.887","article-title":"Regeneration of rotator cuff tear using electrospun poly(d,l-Lactide-Co-Glycolide) scaffolds in a rabbit model.","volume":"28","author":"A Inui","year":"2012","journal-title":"Arthroscopy"},{"issue":"14","key":"pone.0234982.ref039","doi-asserted-by":"crossref","first-page":"4056","DOI":"10.1016\/j.biomaterials.2010.01.135","article-title":"A polydioxanone electrospun valved patch to replace the right ventricular outflow tract in a growing lamb model.","volume":"31","author":"D Kalfa","year":"2010","journal-title":"Biomaterials"},{"issue":"7","key":"pone.0234982.ref040","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1002\/mabi.201500455","article-title":"Bioactive, Elastic, and Biodegradable Emulsion Electrospun DegraPol Tube Delivering PDGF-BB for Tendon Rupture Repair.","volume":"16","author":"O Evrova","year":"2016","journal-title":"Macromol Biosci"},{"issue":"8","key":"pone.0234982.ref041","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1039\/C6BM00958A","article-title":"Macrophage infiltration of electrospun polyester fibers.","volume":"5","author":"S Liu","year":"2017","journal-title":"Biomater Sci"},{"issue":"3","key":"pone.0234982.ref042","first-page":"353","article-title":"A long-term in vivo investigation on the effects of xenogenous based, electrospun, collagen implants on the healing of experimentally-induced large tendon defects.","volume":"13","author":"A Oryan","year":"2013","journal-title":"J Musculoskelet Neuronal Interact."},{"key":"pone.0234982.ref043","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.2147\/IJN.S59536","article-title":"Biological augmentation of rotator cuff repair using bFGF-loaded electrospun poly(lactide-co-glycolide) fibrous membranes.","volume":"9","author":"S Zhao","year":"2014","journal-title":"International journal of nanomedicine"},{"issue":"13\u201314","key":"pone.0234982.ref044","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1089\/ten.tea.2013.0283","article-title":"In vivo skeletal muscle biocompatibility of composite, coaxial electrospun, and microfibrous scaffolds.","volume":"20","author":"KD McKeon-Fischer","year":"2014","journal-title":"Tissue Eng Part A."},{"issue":"1","key":"pone.0234982.ref045","doi-asserted-by":"crossref","first-page":"3615","DOI":"10.1038\/s41598-017-03851-1","article-title":"Small-diameter hybrid vascular grafts composed of polycaprolactone and polydioxanone fibers.","volume":"7","author":"Y Pan","year":"2017","journal-title":"Sci Rep"},{"issue":"4","key":"pone.0234982.ref046","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1002\/mabi.201500355","article-title":"Three-Layered PCL Grafts Promoted Vascular Regeneration in a Rabbit Carotid Artery Model.","volume":"16","author":"K Wang","year":"2016","journal-title":"Macromol Biosci"},{"issue":"12","key":"pone.0234982.ref047","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1080\/09205063.2016.1188349","article-title":"Co-effect of silk and amniotic membrane for tendon repair","volume":"27","author":"YK Seo","year":"2016","journal-title":"J Biomater Sci Polym Ed"},{"issue":"1","key":"pone.0234982.ref048","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1177\/0885328215569891","article-title":"Simple surface coating of electrospun poly-L-lactic acid scaffolds to induce angiogenesis","volume":"30","author":"G Gigliobianco","year":"2015","journal-title":"J Biomater Appl"},{"issue":"4","key":"pone.0234982.ref049","first-page":"497","article-title":"Polydioxanone (PDS), a novel monofilament synthetic absorbable suture.","volume":"153","author":"JA Ray","year":"1981","journal-title":"Surgery, gynecology & obstetrics."},{"issue":"1","key":"pone.0234982.ref050","first-page":"43","article-title":"In-vivo comparison of four absorbable sutures: Vicryl, Dexon Plus, Maxon and PDS.","volume":"31","author":"RB Bourne","year":"1988","journal-title":"Canadian journal of surgery Journal canadien de chirurgie"},{"issue":"13","key":"pone.0234982.ref051","doi-asserted-by":"crossref","first-page":"3387","DOI":"10.1016\/j.biomaterials.2011.01.025","article-title":"Mechanical properties and in vivo behavior of a biodegradable synthetic polymer microfiber-extracellular matrix hydrogel biohybrid scaffold","volume":"32","author":"Y Hong","year":"2011","journal-title":"Biomaterials"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0234982","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T20:23:37Z","timestamp":1593203017000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0234982"}},"subtitle":[],"editor":[{"given":"James H-C","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,6,26]]},"references-count":51,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,6,26]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0234982","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,26]]}}}