{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T00:04:12Z","timestamp":1773705852113,"version":"3.50.1"},"reference-count":55,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2020,6,25]],"date-time":"2020-06-25T00:00:00Z","timestamp":1593043200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007434","name":"Ag\u00eancia Nacional de Inova\u00e7\u00e3o","doi-asserted-by":"publisher","award":["POCI-01-0247-FEDER-017604"],"award-info":[{"award-number":["POCI-01-0247-FEDER-017604"]}],"id":[{"id":"10.13039\/501100007434","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0235087","type":"journal-article","created":{"date-parts":[[2020,6,25]],"date-time":"2020-06-25T17:29:55Z","timestamp":1593106195000},"page":"e0235087","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":14,"title":["Development of an innovative double-chamber syringe for intravenous therapeutics and flushing: Nurses\u2019 involvement through a human-centred approach"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3880-6590","authenticated-orcid":true,"given":"Pedro","family":"Parreira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8914-6975","authenticated-orcid":true,"given":"Liliana","family":"B. Sousa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"In\u00eas A.","family":"Marques","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo","family":"Costa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Cortez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Filipa","family":"Carneiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arm\u00e9nio","family":"Cruz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anabela","family":"Salgueiro-Oliveira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2020,6,25]]},"reference":[{"issue":"6 Suppl","key":"pone.0235087.ref001","first-page":"S1","article-title":"The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC): results from a multis-pecialty panel using the RAND\/UCLA appropriateness method","volume":"163","author":"Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) Panel","year":"2015","journal-title":"Ann Intern Med"},{"key":"pone.0235087.ref002","first-page":"1","volume-title":"Infusion nursing: An evidence-based approach","author":"A Corrigan","year":"2010","edition":"3"},{"issue":"3","key":"pone.0235087.ref003","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1590\/0104-07072014000900013","article-title":"The incidence of phlebitis in a Medical Clinical Unit","volume":"23","author":"C.K. Abdul-Hak","year":"2014","journal-title":"Texto Contexto Enferm"},{"key":"pone.0235087.ref004","doi-asserted-by":"crossref","first-page":"e3002","DOI":"10.1590\/1518-8345.2377.3002","article-title":"Phlebitis and infiltration: Vascular trauma associated with the peripheral venous catheter","volume":"26","author":"L.M. Braga","year":"2018","journal-title":"Revista Latino-Americana de Enfermagem"},{"issue":"6","key":"pone.0235087.ref005","first-page":"517","article-title":"Incidence of local complications in peripheral venous catheters and associated risk factors","volume":"28","author":"M.T.R. Danski","year":"2015","journal-title":"Acta Paul Enferm"},{"issue":"4","key":"pone.0235087.ref006","doi-asserted-by":"crossref","first-page":"61","DOI":"10.12707\/RIII13141","article-title":"Incidence and factors associated with the development of phlebitis: results of a pilot cohort study","volume":"S\u00e9rie IV","author":"L.Z. Rojas-S\u00e1nchez","year":"2015","journal-title":"Rev Enf Ref"},{"issue":"2","key":"pone.0235087.ref007","first-page":"32","article-title":"Incidence of phlebitis in patients with peripheral intravenous catheters: the influence of some risk factors","volume":"30","author":"A Salgueiro-Oliveira","year":"2012","journal-title":"Aust J Adv Nurs"},{"issue":"4","key":"pone.0235087.ref008","first-page":"192","article-title":"2016 Expert consensus document on prevention, diagnosis and treatment of short-term peripheral venous catheter-related infections in adults","volume":"23","author":"on behalf the SEICAV, SEMI, SEQ, and SECTCV Societies","year":"2016","journal-title":"Cir Cardiov"},{"issue":"1S","key":"pone.0235087.ref009","first-page":"S1","article-title":"Infusion therapy standards of practice","volume":"39","author":"Infusion Nurses Society","year":"2016","journal-title":"Journal of Infusion Nursing"},{"issue":"S1","key":"pone.0235087.ref010","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/S0195-6701(13)60012-2","article-title":"Epic3: National evidence-based guidelines for preventing healthcare-associated infections in NHS hospital in England","volume":"86","author":"HP Loveday","year":"2014","journal-title":"Journal of Hospital Infection"},{"key":"pone.0235087.ref011","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1111\/j.1751-553X.2007.00931.x","article-title":"Guidelines on the insertion and management of central venous access devices in adults","volume":"29","author":"L Bishop","year":"2007","journal-title":"International Journal of Laboratory Hematology"},{"issue":"1","key":"pone.0235087.ref012","doi-asserted-by":"crossref","first-page":"75","DOI":"10.5301\/JVA.2011.8487","article-title":"Flushing of intravascular access devices (IVADs)\u2014Efficacy of pulsed and continuous infusions","volume":"13","author":"G Guiffant","year":"2012","journal-title":"The Journal of Vascular Access"},{"issue":"3","key":"pone.0235087.ref013","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/00129804-200505000-00005","article-title":"A theory-based intervention to improve nurses\u2019 knowledge, self-efficacy, and skills to reduce PICC occlusion","volume":"28","author":"A Ngo","year":"2005","journal-title":"Journal of Infusion Nursing"},{"issue":"6","key":"pone.0235087.ref014","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.cherd.2011.10.004","article-title":"The fouling and cleaning of venous catheters: A possible optimization of the process using intermittent flushing","volume":"90","author":"L Royon","year":"2012","journal-title":"Chemical Engineering Research and Design"},{"issue":"2","key":"pone.0235087.ref015","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.rbmret.2005.03.001","article-title":"The use of a hydrodynamic bench for experimental simulation of flushing venous catheters: Impact on the technique","volume":"26","author":"J.P. Vigier","year":"2005","journal-title":"ITBM-RBM"},{"key":"pone.0235087.ref016","volume-title":"Standards for infusion therapy","author":"Royal College of Nursing","year":"2016","edition":"4"},{"issue":"1","key":"pone.0235087.ref017","doi-asserted-by":"crossref","first-page":"e19066","DOI":"10.12707\/RIV19066","article-title":"Peripheral venous catheter flushing: a scoping review protocol","volume":"5","author":"P Parreira","year":"2020","journal-title":"Revista de Enfermagem Refer\u00eancia"},{"key":"pone.0235087.ref018","article-title":"Flushing and locking of venous catheters: Available evidence and evidence deficit","author":"GA Goossens","year":"2015","journal-title":"Nursing Research and Practice"},{"key":"pone.0235087.ref019","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1016\/j.ijnurstu.2015.07.001","article-title":"Nursing and midwifery practice for maintenance of vascular access device patency. A cross-sectional survey","volume":"52","author":"S Keogh","year":"2015","journal-title":"International Journal of Nursing Studies"},{"issue":"2","key":"pone.0235087.ref020","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/NAN.0000000000000024","article-title":"A time and motion study of peripheral venous catheter flushing practice using manually prepared and prefilled flush syringes","volume":"37","author":"S Keogh","year":"2014","journal-title":"Journal of Infusion Nursing"},{"key":"pone.0235087.ref021","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.xphs.2015.11.025","article-title":"Technology, applications, and process challenges of dual chamber systems","volume":"105","author":"T Werk","year":"2016","journal-title":"Journal of Pharmaceutical Sciences"},{"key":"pone.0235087.ref022","unstructured":"European Commission. Regulation (EU) 2017\/745 of the European Parliament and of the Council of 5 April 2017 on medical devices; Author: Brussels, Belgium, 2017."},{"key":"pone.0235087.ref023","article-title":". Comparison of rates of safety issues and reporting of trial outcomes for medical devices approved in the European Union and United States: Cohort study","volume":"353","author":"T.J. Hwang","year":"2016","journal-title":"BMJ"},{"key":"pone.0235087.ref024","unstructured":"Clinical Excellence Commission. The Device Usability Handbook\u2013An introductory resource for NSW health employees. Clinical Excellence Commission: Sydney, Australia, 2017."},{"issue":"3","key":"pone.0235087.ref025","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1017\/S0266462318000314","article-title":"Health Technology Assessment methods guidelines for medical devices: How can we address the gaps? The International Federation of Medical and Biological Engineering perspective","volume":"34","author":"J Polisena","year":"2018","journal-title":"International Journal of Technology Assessment"},{"issue":"Suppl. 1","key":"pone.0235087.ref026","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1002\/hec.3479","article-title":"Linking the regulatory and reimbursement processes for medical devices: The need for integrated assessments","volume":"26","author":"O Ciani","year":"2017","journal-title":"Health Economics"},{"key":"pone.0235087.ref027","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.healthpol.2016.08.010","article-title":"HTA of medical devices: Challenges and ideas for future from a European perspective","volume":"121","author":"S Fuchs","year":"2017","journal-title":"Health Policy"},{"key":"pone.0235087.ref028","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1183\/16000617.0016-2016","article-title":". What type of clinical evidence is needed to assess medical devices?","volume":"25","author":"R Tarricone","year":"2016","journal-title":"European Respiratory Review"},{"issue":"Suppl. 1","key":"pone.0235087.ref029","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1002\/hec.3471","article-title":"Improving the methods for the economic evaluation of medical devices","volume":"26","author":"R Tarricone","year":"2017","journal-title":"Health Economics"},{"issue":"4","key":"pone.0235087.ref030","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1001\/jama.2017.8976","article-title":"Practical improvements for medical device evaluation","volume":"318","author":"D.B. Kramer","year":"2017","journal-title":"JAMA"},{"key":"pone.0235087.ref031","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.zefq.2015.06.011","article-title":"Health technology assessment of medical devices: What is different? An overview of three European projects","volume":"109","author":"P Schnell-Inderst","year":"2015","journal-title":"Z. Evid. Fortbild. Qual. Gesundh. Wesen"},{"key":"pone.0235087.ref032","article-title":"IDEAL-D: A rational framework for evaluating and regulating the use of medical devices","volume":"353","author":"A Sedrakyan","year":"2016","journal-title":"BMJ"},{"issue":"Suppl. 1","key":"pone.0235087.ref033","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1002\/hec.3469","article-title":"Challenges in the assessment of medical devices: The MedTecHTA project","volume":"26","author":"R Tarricone","year":"2017","journal-title":"Health Economics"},{"key":"pone.0235087.ref034","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1186\/s13063-017-2168-0","article-title":"Specific barriers to the conduct of randomized clinical trials on medical devices","volume":"18","author":"E.A.M. Neugebauer","year":"2017","journal-title":"Trials"},{"key":"pone.0235087.ref035","unstructured":"EUnetHTA Joint action European Network for Health Technology Assessment Joint Action on HTA 2012\u20132015: HTA core model for rapid relative effectiveness. EUnetHTA: Diemen, Netherlands, 2015."},{"key":"pone.0235087.ref036","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/1472-6947-12-74","article-title":"Integrating the results of user research into medical device development: Insights from a case study","volume":"12","author":"J. L. Martin","year":"2012","journal-title":"BMC Medical Informatics & Decision Making"},{"key":"pone.0235087.ref037","unstructured":"International Organization for Standardization ISO IEC 62366\u20131: Medical devices\u2014Part 1: Application of usability engineering to medical devices. Author: Geneva, Switzerland, 2015."},{"issue":"1","key":"pone.0235087.ref038","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.2196\/humanfactors.5443","article-title":"A human-centered design methodology to enhance the usability, human factors, and user experience of connected health systems: A three-phase methodology","volume":"4","author":"R Harte","year":"2017","journal-title":"JMIR Human Factors"},{"key":"pone.0235087.ref039","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1088\/0967-3334\/27\/8\/R01","article-title":"Capturing user requirements in medical device development: The role of ergonomics","volume":"27","author":"J.L. Martin","year":"2006","journal-title":"Physiological Measurement"},{"key":"pone.0235087.ref040","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.apergo.2016.08.034","article-title":"Human factors in the design of medical devices\u2013Approaches to meeting international standards in the European Union and USA","volume":"59","author":"M.B. Privitera","year":"2017","journal-title":"Applied Ergonomics"},{"issue":"1","key":"pone.0235087.ref041","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1080\/17434440.2018.1418661","article-title":"Designing medical technology for resilience: Integrating health economics and human factors approaches","volume":"15","author":"S Borsci","year":"2018","journal-title":"Expert Review of Medical Devices"},{"key":"pone.0235087.ref042","unstructured":"International Organization for Standardization. ISO 13407: Human-centered design processes for interactive systems. Author: Geneva, Switzerland, 1999."},{"key":"pone.0235087.ref043","unstructured":"International Organization for Standardization. ISO 14155: Clinical investigation of medical devices for human subjects\u2013Good clinical practices. Author: Geneva, Switzerland, 2011."},{"key":"pone.0235087.ref044","unstructured":"International Organization for Standardization. ISO 14971: Medical devices\u2013application of risk management to medical devices. Author: Geneva, Switzerland, 2012."},{"key":"pone.0235087.ref045","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.apergo.2007.10.002","article-title":"Medical device development: The challenge for ergonomics","volume":"39","author":"J.L. Martin","year":"2008","journal-title":"Applied Ergonomics"},{"key":"pone.0235087.ref046","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.apergo.2013.05.009","article-title":"Integration of human factors and ergonomics during the medical device design and development: It\u2019s all about communication","volume":"45","author":"C.J. Vincent","year":"2014","journal-title":"Applied Ergonomics"},{"key":"pone.0235087.ref047","unstructured":"Bardin L. L\u2019analyse de contenu. Quadrige\/PUF: Paris, France, 2007."},{"key":"pone.0235087.ref048","first-page":"49","article-title":"Meeting end user needs in collaborative medical device technology development research projects: A qualitative case study","volume":"237","author":"F Strisland","year":"2017","journal-title":"Studies in Health Technology and Informatics"},{"issue":"10","key":"pone.0235087.ref049","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1080\/0951192X.2014.934292","article-title":"Designing, prototyping and manufacturing medical devices: An overview","volume":"27","author":"J Ciurana","year":"2014","journal-title":"International Journal of Computer Integrated Manufacturing"},{"issue":"5","key":"pone.0235087.ref050","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1586\/17434440.2014.940312","article-title":"How many testers are needed to assure the usability of medical devices?","volume":"11","author":"S Borsci","year":"2014","journal-title":"Expert Reviews Medical Devices"},{"issue":"5","key":"pone.0235087.ref051","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1145\/2506210","article-title":"Reviewing and extending the five-user assumption: a grounded procedure for interaction evaluation","volume":"20","author":"S Borsci","year":"2013","journal-title":"ACM Transactions on Computer-Human Interaction (TOCHI)"},{"key":"pone.0235087.ref052","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.clsr.2017.03.019","article-title":"The EU commission\u2019s risky choice for a non-risk based strategy on assessment of medical devices","volume":"33","author":"P Quinn","year":"2017","journal-title":"Computer Law & Security Review"},{"key":"pone.0235087.ref053","first-page":"1505","article-title":"The potential of medical device industry in technological and economical context","volume":"11","author":"P Maresova","year":"2015","journal-title":"Therapeutics and Clinical Risk Management"},{"issue":"3","key":"pone.0235087.ref054","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1586\/erd.12.89","article-title":"Additional peculiarities of medical devices that should be considered in their development process","volume":"10","author":"I.C.T. Santos","year":"2013","journal-title":"Expert Reviews Medical Devices"},{"key":"pone.0235087.ref055","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1186\/s13063-019-3887-1","article-title":"Double-chamber syringe versus classic syringes for peripheral intravenous drug administration and catheter flushing: a study protocol for a randomized controlled trial","volume":"21","author":"P Parreira","year":"2020","journal-title":"Trials"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0235087","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,25]],"date-time":"2020-06-25T17:30:16Z","timestamp":1593106216000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0235087"}},"subtitle":[],"editor":[{"given":"Simone","family":"Borsci","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,6,25]]},"references-count":55,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,6,25]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0235087","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,25]]}}}