{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:21:39Z","timestamp":1759335699119,"version":"3.37.3"},"reference-count":17,"publisher":"Public Library of Science (PLoS)","issue":"7","license":[{"start":{"date-parts":[[2020,7,7]],"date-time":"2020-07-07T00:00:00Z","timestamp":1594080000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0235593","type":"journal-article","created":{"date-parts":[[2020,7,7]],"date-time":"2020-07-07T17:43:38Z","timestamp":1594143818000},"page":"e0235593","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":4,"title":["Leakage of isopropanol from port protectors used in neonatal care\u2014Results from an in vitro study"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0958-7341","authenticated-orcid":true,"given":"Louise Bj\u00f6rkman","family":"Hjalmarsson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessika","family":"Hagberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens","family":"Schollin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Ohlin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2020,7,7]]},"reference":[{"issue":"2","key":"pone.0235593.ref001","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1093\/infdis\/167.2.487","article-title":"A prospective study of the catheter hub as the portal of entry for microorganisms causing catheter-related sepsis in neonates","volume":"167","author":"MB Salzman","year":"1993","journal-title":"J Infect Dis"},{"issue":"6","key":"pone.0235593.ref002","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.ajic.2010.03.007","article-title":"Reduction in central line-associated bloodstream infections by implementation of a postinsertion care bundle","volume":"38","author":"K Guerin","year":"2010","journal-title":"Am J Infect Control"},{"key":"pone.0235593.ref003","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jcrc.2017.02.035","article-title":"Incidence of central venous catheter hub contamination","volume":"39","author":"JL Holroyd","year":"2017","journal-title":"J Crit Care"},{"key":"pone.0235593.ref004","unstructured":"Centers for Disease Control and Prevention. Guidelines for the prevention of intravascular catheter-related infections 2011 [Available from: http:\/\/www.cdc.gov\/hicpac\/pdf\/guidelines\/bsi-guidelines-2011.pdf."},{"issue":"10","key":"pone.0235593.ref005","doi-asserted-by":"crossref","first-page":"S174 e1","DOI":"10.1016\/j.ajic.2008.10.006","article-title":"Preventing central venous catheter-associated bloodstream infections: development of an antiseptic barrier cap for needleless connectors","volume":"36","author":"SZ Menyhay","year":"2008","journal-title":"Am J Infect Control"},{"issue":"1","key":"pone.0235593.ref006","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.ajic.2015.08.026","article-title":"Adding innovative practices and technology to central line bundle reduces bloodstream infection rate in challenging pediatric population","volume":"44","author":"M Pavia","year":"2016","journal-title":"Am J Infect Control"},{"key":"pone.0235593.ref007","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.ijnurstu.2017.01.007","article-title":"Antiseptic barrier cap effective in reducing central line-associated bloodstream infections: a systematic review and meta-analysis","volume":"69","author":"AF Voor In 't Holt","year":"2017","journal-title":"Int J Nurs Stud"},{"issue":"12","key":"pone.0235593.ref008","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1016\/j.ajic.2014.09.008","article-title":"Impact of universal disinfectant cap implementation on central line-associated bloodstream infections","volume":"42","author":"KC Merrill","year":"2014","journal-title":"Am J Infect Control"},{"issue":"11","key":"pone.0235593.ref009","doi-asserted-by":"crossref","first-page":"e489","DOI":"10.1111\/apa.13099","article-title":"Using isopropyl alcohol impregnated disinfection caps in the neonatal intensive care unit can cause isopropyl alcohol toxicity","volume":"104","author":"C Sauron","year":"2015","journal-title":"Acta Paediatr"},{"issue":"3","key":"pone.0235593.ref010","doi-asserted-by":"crossref","first-page":"E12","DOI":"10.1053\/ajkd.2002.34938","article-title":"Isopropyl alcohol intoxication: a diagnostic challenge","volume":"40","author":"F Zaman","year":"2002","journal-title":"Am J Kidney Dis"},{"issue":"2","key":"pone.0235593.ref011","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/00006565-199404000-00008","article-title":"Isopropyl alcohol intoxication in a neonate through chronic dermal exposure: a complication of a culturally-based umbilical care practice","volume":"10","author":"PM Vivier","year":"1994","journal-title":"Pediatr Emerg Care"},{"issue":"1","key":"pone.0235593.ref012","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.jen.2009.10.006","article-title":"Isopropyl alcohol intoxication","volume":"36","author":"JD Clark","year":"2010","journal-title":"J Emerg Nurs"},{"issue":"12","key":"pone.0235593.ref013","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1177\/0960327107087794","article-title":"Poisoning with 1-propanol and 2-propanol","volume":"26","author":"M Vujasinovic","year":"2007","journal-title":"Hum Exp Toxicol"},{"issue":"5","key":"pone.0235593.ref014","doi-asserted-by":"crossref","first-page":"470","DOI":"10.3109\/15563650.2014.914527","article-title":"Isopropanol poisoning","volume":"52","author":"RJ Slaughter","year":"2014","journal-title":"Clin Toxicol (Phila)"},{"issue":"3","key":"pone.0235593.ref015","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1097\/00006565-199306000-00007","article-title":"Two-week-old infant with isopropanol intoxication","volume":"9","author":"TT Mydler","year":"1993","journal-title":"Pediatr Emerg Care"},{"issue":"8","key":"pone.0235593.ref016","doi-asserted-by":"crossref","first-page":"e77","DOI":"10.1016\/j.ajic.2012.10.018","article-title":"Disinfection of needleless connectors with chlorhexidine-alcohol provides long-lasting residual disinfectant activity","volume":"41","author":"H Hong","year":"2013","journal-title":"Am J Infect Control"},{"issue":"3","key":"pone.0235593.ref017","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1038\/sj.jp.7211646","article-title":"Transplacental isopropanol exposure: case report and review of metabolic principles","volume":"27","author":"JN Wood","year":"2007","journal-title":"J Perinatol"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0235593","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,7]],"date-time":"2020-07-07T17:43:56Z","timestamp":1594143836000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0235593"}},"subtitle":[],"editor":[{"given":"Shawn D.","family":"Larson","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,7,7]]},"references-count":17,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2020,7,7]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0235593","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2020,7,7]]}}}