{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T14:42:07Z","timestamp":1788273727931,"version":"build-2803163510"},"reference-count":24,"publisher":"Public Library of Science (PLoS)","issue":"8","license":[{"start":{"date-parts":[[2021,8,3]],"date-time":"2021-08-03T00:00:00Z","timestamp":1627948800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007514","name":"Universit\u00e0 di Pisa","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007514","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Recently, the use of smartphone ECG devices has been reported in humans and animals. Nevertheless, as the electrodes of these devices are inseparable, they can create only a precordial reading in veterinary species. Thus, although the smartphone ECG devices are considered valuable as a screening tool for the detection of some common arrhythmias, they are not always a reliable method for the measurement of the duration of the electrical deflections. The objectives of this study were to evaluate the feasibility of a novel smartphone ECG device, to report the readings obtained recorded simultaneously with a reference ECG system, and to compare the heart rate and duration of cardiac deflections obtained with the two methods. A total of 28 healthy mares of different breeds and age were included in this study and ECG recordings were obtained simultaneously with a reference ECG telemetry system with surface electrodes attached to the skin with alligator clips using a standard base-apex system and a smartphone ECG device with electrodes positioned alternatively with a standard and a modified base apex derivation. All the recordings obtained were considered acceptable for interpretation. An excellent agreement was found between the two methods for the evaluation of heart rate and polarity of cardiac deflections. No differences regarding number, duration and percentage of artifacts were found. This technology could become a valid diagnostic tool in the cardiological assessment of horses, in particular on the field.<\/jats:p>","DOI":"10.1371\/journal.pone.0255247","type":"journal-article","created":{"date-parts":[[2021,8,3]],"date-time":"2021-08-03T17:28:09Z","timestamp":1628011689000},"page":"e0255247","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":17,"title":["Evaluation of a new portable 1-lead digital cardiac monitor (eKuore) compared with standard base-apex electrocardiography in healthy horses"],"prefix":"10.1371","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2273-5377","authenticated-orcid":true,"given":"Valentina","family":"Vitale","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommaso","family":"Vezzosi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosalba","family":"Tognetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlotta","family":"Fraschetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micaela","family":"Sgorbini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2021,8,3]]},"reference":[{"key":"pone.0255247.ref001","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/B978-0-7020-2817-5.00018-3","volume-title":"Cardiology of the Horse","author":"VB Reef","year":"2010","edition":"2"},{"key":"pone.0255247.ref002","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.jevs.2018.03.006","article-title":"Evaluation of a Smartphone Electrocardiograph in Healthy Horses: Comparison With Standard Base-apex Electrocardiography","volume":"67","author":"T Vezzosi","year":"2018","journal-title":"Journal of Equine Veterinary Science"},{"key":"pone.0255247.ref003","doi-asserted-by":"crossref","first-page":"2101","DOI":"10.1111\/jvim.15795","article-title":"Stall-side screening potential of a smartphone electrocardiogram recorded over both sides of the thorax in horses","volume":"34","author":"I Corradini","year":"2020","journal-title":"Journal of Veterinary Internal Medicine"},{"key":"pone.0255247.ref004","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.tvjl.2016.06.013","article-title":"Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography.","volume":"216","author":"T Vezzosi","year":"2016","journal-title":"Vet J"},{"key":"pone.0255247.ref005","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1111\/jvim.15396","article-title":"Comparison of smartphone-based and standard base-apex electrocardiography in healthy dairy cows","volume":"33","author":"F Bonelli","year":"2019","journal-title":"J Vet Intern Med"},{"key":"pone.0255247.ref006","doi-asserted-by":"crossref","first-page":"e0204403","DOI":"10.1371\/journal.pone.0204403","article-title":"Can smartphone wireless ECGs be used to accurately assess ECG intervals in pediatrics? A comparison of mobile health monitoring to standard 12-lead ECG.","volume":"13","author":"MRF Gropler","year":"2018","journal-title":"PLoS One"},{"key":"pone.0255247.ref007","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1111\/jce.12634","article-title":"Wireless Smartphone ECG Enables Large-Scale Screening in Diverse Populations","volume":"26","author":"ZC Haberman","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"pone.0255247.ref008","doi-asserted-by":"crossref","first-page":"189","DOI":"10.2460\/javma.249.2.189","article-title":"Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats","volume":"249","author":"MS Kraus","year":"2016","journal-title":"J Am Vet Med Assoc"},{"key":"pone.0255247.ref009","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1177\/2047487314552604","article-title":"Acquisition and analysis of cardiovascular signals on smartphones: potential, pitfalls and perspectives: by the Task Force of the e-Cardiology Working Group of European Society of Cardiology","volume":"21","author":"N Bruining","year":"2014","journal-title":"Eur J Prev Cardiol"},{"key":"pone.0255247.ref010","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1111\/jce.12097","article-title":"Ubiquitous wireless ECG recording: a powerful tool physicians should embrace","volume":"24","author":"LA Saxon","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"1","key":"pone.0255247.ref011","doi-asserted-by":"crossref","first-page":"e000441","DOI":"10.1136\/vetreco-2020-000441","article-title":"Evaluation of a smartphone-based electrocardiogram device accuracy in field and hospital conditions in horses","volume":"7","author":"E Alberti","year":"2020","journal-title":"Vet Rec Open"},{"key":"pone.0255247.ref012","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.rvsc.2019.05.018","article-title":"Utility and accuracy of a smartphone-based electrocardiogram device as compared to a standard base-apex electrocardiogram in the horse","volume":"125","author":"MS Kraus","year":"2019","journal-title":"Res Vet Sci"},{"key":"pone.0255247.ref013","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/B978-0-7020-2817-5.00011-0","volume-title":"Cardiology of the Horse","author":"G Van Loon","year":"2010","edition":"2"},{"key":"pone.0255247.ref014","doi-asserted-by":"crossref","first-page":"e70","DOI":"10.1136\/vr.105759","article-title":"Comparison between smartphone electrocardiography and standard three-lead base apex electrocardiography in healthy horses","volume":"187","author":"B Welch-Huston","year":"2020","journal-title":"Vet Rec"},{"key":"pone.0255247.ref015","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1111\/j.2042-3306.2012.00653.x","article-title":"Ventricular response during lungeing exercise in horses with lone atrial fibrillation","volume":"45","author":"T Verheyen","year":"2013","journal-title":"Equine Vet J"},{"key":"pone.0255247.ref016","unstructured":"Kraus MS, Rishniw MR, Gelzer AR, et al. Comparison of the smartphone electrocardiogram device with a reference standard base apex electrocardiogram in horses. In: Proceedings of the 59th Annual Convention of the American Association of Equine Practitioners, Nashville, Tennessee, USA, 7\u201311 December 2013 2013;271\u2013272."},{"key":"pone.0255247.ref017","unstructured":"Vera L, Van Steenkiste G, Decloedt A, et al. Comparison of smartphone\u2010based and standard electrocardiography in healthy horses. In: British Equine Veterinary Association Congres 2019."},{"key":"pone.0255247.ref018","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.cvex.2019.05.001","article-title":"Smartphone-Based Device in Exotic Pet Medicine","volume":"22","author":"M Huynh","year":"2019","journal-title":"Vet Clin North Am Exot Anim Pract"},{"key":"pone.0255247.ref019","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1161\/CIRCULATIONAHA.114.009024","article-title":"Novel wireless devices for cardiac monitoring","volume":"130","author":"JA Walsh","year":"2014","journal-title":"Circulation"},{"key":"pone.0255247.ref020","first-page":"331","article-title":"Electrocardiography in horses\u2013part 1: how to make a good recording","volume":"79","author":"T Verheyen","year":"2010","journal-title":"Vlaams Diergeneeskundig Tijdschrift"},{"key":"pone.0255247.ref021","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/B978-0-7020-2671-3.50037-4","volume-title":"Equine Sports Medicine and Surgery\u2013Basic and Clinical Sciences of the Equine Athlete","author":"L Young","year":"2004"},{"key":"pone.0255247.ref022","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jevs.2019.06.001","article-title":"Two methods for 24-hour monitoring in horses: evaluation of recording performance at rest and during exercise","volume":"79","author":"T Vezzosi","year":"2019","journal-title":"J Equine Vet Sci"},{"issue":"3","key":"pone.0255247.ref023","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1136\/vr.104917","article-title":"Home monitoring of heart rate and heart rhythm with a smartphone-based ECG in dogs","volume":"184","author":"T Vezzosi","year":"2019","journal-title":"Vet Rec"},{"issue":"2","key":"pone.0255247.ref024","first-page":"119","article-title":"Veterinary telemedicine","volume":"60","author":"C Gyles","year":"2019","journal-title":"Can Vet J"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0255247","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,3]],"date-time":"2021-08-03T17:28:35Z","timestamp":1628011715000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0255247"}},"subtitle":[],"editor":[{"given":"Arianna","family":"Miglio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2021,8,3]]},"references-count":24,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2021,8,3]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0255247","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,3]]}}}