{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:01:31Z","timestamp":1787022091668,"version":"build-2736575974"},"reference-count":18,"publisher":"Public Library of Science (PLoS)","issue":"10","license":[{"start":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T00:00:00Z","timestamp":1634860800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002806","name":"carl zeiss meditec ag","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002806","id-type":"DOI","asserted-by":"publisher"}]},{"name":"iq laser vision"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To report the visual and refractive results of small incision lenticule extraction (SMILE) with low energy settings in the United States (US) and to evaluate outcomes for low astigmatism treatment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>Private clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Retrospective cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This study retrospectively reviewed 462 consecutive eyes that underwent SMILE with lower energy settings. Inclusion criteria included all patients between the ages of 19\u201339 with myopic astigmatism up to -11.25 diopters (D) spherical equivalent (sphere up to -10.00 D, astigmatism up to -3.00 D), and corrected distance visual acuity of at least 20\/25. Eyes with low astigmatism (0.25 D-0.50 D) were also included. Outcome analysis was performed according to the Standard Graphs for Reporting Refractive Surgery at postoperative month (POM) 1, and POM 3\u20136 when data were available.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec005\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The mean preoperative spherical equivalent treated was -4.96 \u00b1 2.07; at POM 1, 92% of eyes achieved uncorrected visual acuity (UCVA) of 20\/20 or better and maintained visual stability throughout the remainder of the study. At last visit, 431 eyes (93%) achieved UCVA of 20\/20 or better, and 461 eyes (99.8%) were 20\/25 or better. Ninety-seven (21%) eyes gained at least 1 Snellen line of corrected distance visual acuity and no eyes lost 2 or more lines. Almost all eyes (n = 453, 98%) were within 0.5D of target; 85% of eyes with low astigmatism had \u22640.25 D at last visit compared to 80% of eyes with moderate astigmatism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec006\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>SMILE with U.S.-approved low energy settings is safe, predictable, and efficacious and provides patients with a fast visual recovery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0258835","type":"journal-article","created":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T18:13:16Z","timestamp":1634926396000},"page":"e0258835","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":4,"title":["Refractive results with SMILE using lower energy settings in the United States"],"prefix":"10.1371","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4392-7917","authenticated-orcid":true,"given":"Erica T.","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4748-4685","authenticated-orcid":true,"given":"Ruti","family":"Sella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Goernert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henry","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert T.","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2021,10,22]]},"reference":[{"issue":"9","key":"pone.0258835.ref001","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1016\/j.jcrs.2008.05.033","article-title":"First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: six-month results","volume":"34","author":"W Sekundo","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"pone.0258835.ref002","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s40662-014-0003-1","article-title":"Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes","volume":"1","author":"DZ Reinstein","year":"2014","journal-title":"Eye Vis (Lond)"},{"issue":"10","key":"pone.0258835.ref003","doi-asserted-by":"crossref","first-page":"e77797","DOI":"10.1371\/journal.pone.0077797","article-title":"Comparison of dry eye and corneal sensitivity between small incision lenticule extraction and femtosecond LASIK for myopia","volume":"8","author":"M Li","year":"2013","journal-title":"PLoS One"},{"issue":"3","key":"pone.0258835.ref004","doi-asserted-by":"crossref","first-page":"e373","DOI":"10.1111\/aos.14017","article-title":"Five-year results of small incision lenticule extraction (SMILE) and femtosecond laser LASIK (FS-LASIK) for myopia","volume":"97","author":"M Li","year":"2019","journal-title":"Acta Ophthalmol"},{"issue":"11","key":"pone.0258835.ref005","doi-asserted-by":"crossref","first-page":"690","DOI":"10.3928\/1081597X-20190930-02","article-title":"SMILE, Topography-Guided LASIK, and Wavefront-Guided LASIK: Review of Clinical Outcomes in Premarket Approval FDA Studies","volume":"35","author":"JM Schallhorn","year":"2019","journal-title":"J Refract Surg"},{"issue":"2","key":"pone.0258835.ref006","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1007\/s40123-018-0137-7","article-title":"Initial Single-Site Surgical Experience with SMILE: A Comparison of Results to FDA SMILE, and the Earliest and Latest Generation of LASIK","volume":"7","author":"M Moshirfar","year":"2018","journal-title":"Ophthalmol Ther"},{"issue":"7","key":"pone.0258835.ref007","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1097\/j.jcrs.0000000000000203","article-title":"Visual outcomes after SMILE from the first-year experience at a U.S. military refractive surgery center and comparison with PRK and LASIK outcomes","volume":"46","author":"RK Sia","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"pone.0258835.ref008","unstructured":"Carl Zeiss Meditec. VisuMax Femtosecond Laser: Small Incision Lenticule Extraction (SMILE) procedure for the correction of myopia. Professiomal Use Information. Available at: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/P150040D.pdf Accessed June 23, 2020. Dublin, CA: Carl Zeiss Meditec."},{"key":"pone.0258835.ref009","unstructured":"Carl Zeiss Meditec. Summary of Safety and Effectiveness Data. Available at: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/p150040s003b.pdf. Accessed June 23, 2020. Dublin, CA: Carl Zeiss Meditec; 2018."},{"key":"pone.0258835.ref010","article-title":"Comparison of early visual outcomes following low-energy SMILE, high-energy SMILE, and LASIK for myopia and myopic astigmatism in the United States","author":"M Nejad","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"pone.0258835.ref011","doi-asserted-by":"crossref","first-page":"636","DOI":"10.3928\/1081597X-20160602-01","article-title":"Lower Energy Levels Improve Visual Recovery in Small Incision Lenticule Extraction (SMILE)","volume":"32","author":"D Donate","year":"2016","journal-title":"J Refract Surg"},{"issue":"1","key":"pone.0258835.ref012","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3928\/1081597X-20171115-01","article-title":"Energy Setting and Visual Outcomes in SMILE: A Retrospective Cohort Study","volume":"34","author":"L Li","year":"2018","journal-title":"J Refract Surg"},{"issue":"1","key":"pone.0258835.ref013","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3928\/1081597X-20101116-01","article-title":"Standardized graphs and terms for refractive surgery results","volume":"27","author":"GO Waring","year":"2011","journal-title":"J Refract Surg"},{"key":"pone.0258835.ref014","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.ajo.2017.05.005","article-title":"Lower Laser Energy Levels Lead to Better Visual Recovery After Small-Incision Lenticule Extraction: Prospective Randomized Clinical Trial","volume":"179","author":"YW Ji","year":"2017","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"pone.0258835.ref015","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/APO.0000000000000259","article-title":"Enhancement Options After Myopic Small-Incision Lenticule Extraction (SMILE): A Review","volume":"8","author":"J Siedlecki","year":"2019","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"6","key":"pone.0258835.ref016","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.ophtha.2017.01.053","article-title":"Enhancement after Small-Incision Lenticule Extraction: Incidence, Risk Factors, and Outcomes","volume":"124","author":"YC Liu","year":"2017","journal-title":"Ophthalmology"},{"issue":"1","key":"pone.0258835.ref017","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1186\/s12886-016-0331-0","article-title":"Four-year observation of predictability and stability of small incision lenticule extraction","volume":"16","author":"T Han","year":"2016","journal-title":"BMC OphthalmolPubMed Central PMCID"},{"issue":"10","key":"pone.0258835.ref018","doi-asserted-by":"crossref","first-page":"618","DOI":"10.3928\/1081597X-20190826-02","article-title":"10-Year Results of Small Incision Lenticule Extraction","volume":"35","author":"M Blum","year":"2019","journal-title":"J Refract Surg"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0258835","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T18:13:42Z","timestamp":1634926422000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0258835"}},"subtitle":[],"editor":[{"given":"Yu-Chi","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2021,10,22]]},"references-count":18,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2021,10,22]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0258835","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,22]]}}}