{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T03:45:20Z","timestamp":1785469520944,"version":"3.56.0"},"reference-count":27,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2022,5,24]],"date-time":"2022-05-24T00:00:00Z","timestamp":1653350400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Ratchadapiseksompotch","award":["CU_GR_63_146_30_53"],"award-info":[{"award-number":["CU_GR_63_146_30_53"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Purpose<\/jats:title>\n<jats:p>To evaluate agreement of total corneal power (TCP) measured by swept-source anterior segment optical coherence tomography (CASIA 2), Scheimpflug tomography (Pentacam AXL), and swept-source optical biometer (IOLMaster 700) in normal and keratoconic patients.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Methods<\/jats:title>\n<jats:p>This is a prospective observational study conducted at King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Biometric values were measured by each device for three times by two operators to evaluate repeatability and reproducibility of TCP. The agreement of TCP and other parameters including total corneal astigmatism, anterior keratometry, anterior corneal astigmatism, posterior keratometry, posterior corneal astigmatism, anterior chamber depth, white-to-white corneal diameter (WTW), central corneal thickness, and intraocular power were also evaluated.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Results<\/jats:title>\n<jats:p>This study enrolled 100 healthy participants and 34 patients with keratoconus. The repeatability and reproducibility of TCP were high in all devices (ICC &gt; 0.9). The agreement of TCP was excellent among three devices in both groups (ICC &gt; 0.9). However, the agreement of TCP between CASIA 2 and IOLMaster 700 was slightly lower in healthy participants (ICC = 0.867) and keratoconic patients (ICC = 0.852) with mean differences of more than 1.0 diopter is clinically significant. Wider 95% limit of agreement were found in keratoconic eyes. Most of other parameters showed good to excellent agreement except WTW which showed poor to moderate agreement in both groups. IOL power showed clinically significant differences in patients with keratoconus.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec004\">\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The agreement of TCP measured by three devices was excellent in normal and keratoconic patients. However, TCP cannot be used interchangeably between devices.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0268856","type":"journal-article","created":{"date-parts":[[2022,5,24]],"date-time":"2022-05-24T17:38:42Z","timestamp":1653413922000},"page":"e0268856","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":28,"title":["Agreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients"],"prefix":"10.1371","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2102-4015","authenticated-orcid":true,"given":"Rosepon","family":"Asawaworarit","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1020-6833","authenticated-orcid":true,"given":"Vannarut","family":"Satitpitakul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parichart","family":"Taweekitikul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3818-9761","authenticated-orcid":true,"given":"Krit","family":"Pongpirul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2022,5,24]]},"reference":[{"issue":"1","key":"pone.0268856.ref001","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.jcrs.2007.08.015","article-title":"Pentacam keratometry and IOL power calculation","volume":"34","author":"S. Norrby","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"pone.0268856.ref002","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","article-title":"Contribution of posterior corneal astigmatism to total corneal astigmatism","volume":"38","author":"DD Koch","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0268856.ref003","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1097\/j.jcrs.0000000000000136","article-title":"Evaluation of total corneal power measurements with a new optical biometer","volume":"46","author":"M Shajari","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"pone.0268856.ref004","doi-asserted-by":"crossref","first-page":"93","DOI":"10.4103\/jovr.jovr_19_17","article-title":"Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes","volume":"13","author":"S Feizi","year":"2018","journal-title":"J Ophthalmic Vis Res"},{"issue":"10","key":"pone.0268856.ref005","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/j.jcrs.2015.03.019","article-title":"Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer","volume":"41","author":"S Srivannaboon","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"pone.0268856.ref006","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0886-3350(98)80284-8","article-title":"Live-epikeratophakia for keratoconus","volume":"24","author":"JH Krumeich","year":"1998","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"pone.0268856.ref007","article-title":"Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses","volume":"33","author":"HB Fam","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"8476","key":"pone.0268856.ref008","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"JM Bland","year":"1986","journal-title":"Lancet"},{"issue":"7059","key":"pone.0268856.ref009","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1136\/bmj.313.7059.744","article-title":"Measurement error","volume":"313","author":"JM Bland","year":"1996","journal-title":"BMJ"},{"issue":"7049","key":"pone.0268856.ref010","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1136\/bmj.313.7049.106","article-title":"Measurement error proportional to the mean","volume":"313","author":"JM Bland","year":"1996","journal-title":"BMJ"},{"issue":"2","key":"pone.0268856.ref011","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"TK Koo","year":"2016","journal-title":"J Chiropr Med"},{"issue":"6","key":"pone.0268856.ref012","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.ophtha.2015.01.021","article-title":"Corneal thickness profile and posterior corneal astigmatism in normal corneas","volume":"122","author":"Y Ueno","year":"2015","journal-title":"Ophthalmology"},{"issue":"4","key":"pone.0268856.ref013","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1016\/j.jcrs.2012.11.022","article-title":"Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera","volume":"39","author":"G Savini","year":"2013","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"pone.0268856.ref014","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1007\/s00417-019-04443-7","article-title":"Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery","volume":"257","author":"S Srivannaboon","year":"2019","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"4","key":"pone.0268856.ref015","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.jcrs.2018.02.015","article-title":"Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras","volume":"44","author":"G Savini","year":"2018","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0268856.ref016","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1038\/s41433-020-01245-8","article-title":"Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging","volume":"35","author":"G Savini","year":"2021","journal-title":"Eye (Lond)"},{"issue":"10","key":"pone.0268856.ref017","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1016\/j.jcrs.2011.05.027","article-title":"Corneal topographic analysis in patients with keratoconus using 3-dimensional anterior segment optical coherence tomography","volume":"37","author":"T Nakagawa","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0268856.ref018","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.clae.2014.04.004","article-title":"Repeatability and reproducibility of Galilei measurements in normal keratoconic and postrefractive corneas","volume":"37","author":"E G\u00fcler","year":"2014","journal-title":"Cont Lens Anterior Eye"},{"issue":"1","key":"pone.0268856.ref019","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1038\/s41598-020-57926-7","article-title":"Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus","volume":"10","author":"D Schiano-Lomoriello","year":"2020","journal-title":"Sci Rep"},{"issue":"5","key":"pone.0268856.ref020","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.jcrs.2014.08.043","article-title":"Effect of keratoconus grades on repeatability of keratometry readings: Comparison of 5 devices","volume":"41","author":"H Hashemi","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0268856.ref021","first-page":"21","article-title":"Progression in Keratoconus","volume":"5","author":"P PR Vinciguerra","year":"2016","journal-title":"Int J Kerat Ect Cor Dis"},{"key":"pone.0268856.ref022","doi-asserted-by":"crossref","first-page":"85","DOI":"10.2147\/OPTO.S210721","article-title":"Posterior corneal astigmatism: a review article","volume":"11","author":"SF Mohammadi","year":"2019","journal-title":"Clin Optom (Auckl)"},{"issue":"3","key":"pone.0268856.ref023","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.jcrs.2011.10.027","article-title":"Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus","volume":"38","author":"E Szalai","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0268856.ref024","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s10792-020-01552-9","article-title":"Agreement of white-to-white measurements with swept-source OCT, Scheimpflug and color LED devices","volume":"41","author":"P Tana-Rivero","year":"2021","journal-title":"Int Ophthalmol"},{"issue":"1","key":"pone.0268856.ref025","doi-asserted-by":"crossref","first-page":"6501","DOI":"10.1038\/s41598-020-63546-y","article-title":"Development of a new intraocular lens power calculation method based on lens position estimated with optical coherence tomography","volume":"10","author":"T Satou","year":"2020","journal-title":"Sci Rep"},{"issue":"5","key":"pone.0268856.ref026","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2018.11.029","article-title":"Intraocular lens power calculation in eyes with keratoconus","volume":"45","author":"G Savini","year":"2019","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0268856.ref027","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1097\/j.jcrs.0000000000000082","article-title":"Intraocular lens power calculation in eyes with keratoconus","volume":"46","author":"N Garz\u00f3n","year":"2020","journal-title":"J Cataract Refract Surg"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0268856","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,24]],"date-time":"2022-05-24T17:39:15Z","timestamp":1653413955000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0268856"}},"subtitle":[],"editor":[{"given":"Rajiv R.","family":"Mohan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,5,24]]},"references-count":27,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,5,24]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0268856","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,24]]}}}