{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T18:28:04Z","timestamp":1793816884514,"version":"4.6.1"},"reference-count":23,"publisher":"Public Library of Science (PLoS)","issue":"8","license":[{"start":{"date-parts":[[2022,8,26]],"date-time":"2022-08-26T00:00:00Z","timestamp":1661472000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Coordination for the Improvement of Level Personnel - CAPES","award":["88882.4333686\/2019-1"],"award-info":[{"award-number":["88882.4333686\/2019-1"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Introduction<\/jats:title>\n<jats:p>The aim of this study was to describe and evaluate a novel plate designed specifically for the canine ilium using finite element methods. The cranial portion of the plate had an elliptical shape and contained nine screw holes. The caudal portion of the plate was triangular with three screw holes. Four and three screws were used at the cranial (screw 1 to 4) and caudal (screw 5 to 7) segment of the plate. Finite element models of the plate and canine pelvis were created. A load of 300 N was applied on the femur-hip joint contact area. Values of Von Mises Stress on the plate, screws and the maximum and minimum main stresses in the bone were used to capture the mechanical factors in this study.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Results<\/jats:title>\n<jats:p>The novel implant had a plate stress of 51.9 megapascals (MPa) with higher stress in the dorsal part of the plate. Screws 2 and 4 showed similar stress values of 17.3 MPa. Screws 1 and 3 were the most loaded (51.9 MPa and 75 MPa, respectively). Screws 5, 6, and 7 showed similar dissipation and stress values (21.55 MPa). There was traction force in the dorsal region of the pubis and compression in the ventral part, with dissipation and values of 15.4 MPa and 23.9 MPa, respectively, acquiring balance between them.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Conclusion<\/jats:title>\n<jats:p>The novel plate is potentially applicable and specifically suitable for iliac fractures in dogs. The screws distribution modeled proved itself strategical since the simulated stresses were evenly distributed throughout the implant construct.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0269313","type":"journal-article","created":{"date-parts":[[2022,8,26]],"date-time":"2022-08-26T17:44:05Z","timestamp":1661535845000},"page":"e0269313","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":3,"title":["Preliminary study on a novel dedicated plate for iliac fractures in dogs"],"prefix":"10.1371","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4076-5548","authenticated-orcid":true,"given":"Tryssia S. M.","family":"Moi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruno W.","family":"Minto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana P.","family":"Macedo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dayvid V. F.","family":"Lucena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caio A. S.","family":"Malta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis G. G. G.","family":"Dias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2022,8,26]]},"reference":[{"key":"pone.0269313.ref001","doi-asserted-by":"crossref","first-page":"349","DOI":"10.3415\/VCOT-06-10-0072","article-title":"A biomechanical comparison of external skeletal fixation and plating for the stabilization of ilial osteotomies in dogs","volume":"21","author":"N Fitzpatrick","year":"2008","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref002","doi-asserted-by":"crossref","first-page":"535","DOI":"10.2460\/javma.229.4.535","article-title":"Evaluation of ilial screw loosening after triple pelvic osteotomy in dogs: 227 cases (1992\u20131999)","volume":"226","author":"MT Doornink","year":"2006","journal-title":"JAVMA"},{"key":"pone.0269313.ref003","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.2460\/ajvr.2005.66.1954","article-title":"Evaluation of an osteoconductive resorbable calcium phosphate cement and polymethylmethacrylate for augmentation of orthopedic screws in the pelvis of canine cadavers","volume":"66","author":"GS Hutchinson","year":"2005","journal-title":"Am J Vet Res"},{"key":"pone.0269313.ref004","doi-asserted-by":"crossref","first-page":"430","DOI":"10.3415\/VCOT-14-01-0001","article-title":"A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model","volume":"27","author":"CW Bruce","year":"2014","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref005","doi-asserted-by":"crossref","first-page":"70","DOI":"10.3415\/VCOT-07-12-0111","article-title":"Transilial interlocking plate stabilisation of a sacral fracture and an ilial fracture in a dog","volume":"22","author":"J. Mills","year":"2009","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref006","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1186\/s12917-017-1139-8","article-title":"A biomechanical comparison of conventional dynamic compression plates and string-of-pearls\u2122 locking plates using cantilever bending in a canine ilial fracture model","volume":"13","author":"AR Kenzig","year":"2017","journal-title":"BMC Vet Res"},{"key":"pone.0269313.ref007","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1055\/s-0038-1636484","article-title":"The radiographic evaluation of repaired canine ilial fractures (69 cases)","volume":"17","author":"L Breshears","year":"2004","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref008","doi-asserted-by":"crossref","first-page":"256","DOI":"10.3415\/VCOT-16-05-0065","article-title":"A structural numerical model for the optimization of double pelvic osteotomy in the early treatment of canine hip dysplasia","volume":"30","author":"EM Zanetti","year":"2017","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref009","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/BF00636166","article-title":"The limited contact dynamic compression plate (LC-DCP)","volume":"109","author":"SM Perren","year":"1990","journal-title":"Arch Orthop Trauma Surg"},{"key":"pone.0269313.ref010","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1111\/j.1532-950X.2011.00927.x","article-title":"Use of locking plate and screws for triple pelvic osteotomy","volume":"41","author":"SA Rose","year":"2012","journal-title":"Vet Surg"},{"key":"pone.0269313.ref011","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1186\/s12917-018-1416-1","article-title":"Pelvic modelling and the comparison between plate position for double pelvic osteotomy using artificial cancellous bone and finite elements analysis","volume":"14","author":"M McCartney","year":"2018","journal-title":"BMC Vet Res"},{"key":"pone.0269313.ref012","doi-asserted-by":"crossref","first-page":"396","DOI":"10.5326\/JAAHA-MS-6074","article-title":"Short-term complications associated with TPLO in dogs using 2.0 and 2.7 mm plates","volume":"50","author":"SD Garnett","year":"2004","journal-title":"J Am Anim Hosp Assoc"},{"key":"pone.0269313.ref013","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1177\/1098612X15606958","article-title":"Management and long-term outcome of pelvic fractures: a retrospective study of 43 cats","volume":"19","author":"RL Meeson","year":"2017","journal-title":"J Feline Med Surg"},{"key":"pone.0269313.ref014","doi-asserted-by":"crossref","first-page":"226","DOI":"10.3415\/VCOT-12-05-0060","article-title":"Use of Y-shaped TPLO plates for the stabilization of supracotyloid ilial fractures in four dogs and one cat","volume":"26","author":"P Chou","year":"2013","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref015","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1097\/SCS.0000000000005124","article-title":"A novel approach for horizontal augmentation of posterior maxilla using ridge split technique","volume":"30","author":"NB Karan","year":"2019","journal-title":"J Craniofac Surg"},{"key":"pone.0269313.ref016","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1302\/0301-620X.93B9.26721","article-title":"A comparison of parallel and diverging screw angles in the stability of locked plate constructs","volume":"93","author":"D Wahnert","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"pone.0269313.ref017","first-page":"462","article-title":"Effect of fracture gap on stability of compression plate fixation: a finite element study","volume":"28","author":"JK Oh","year":"2009","journal-title":"J Orthop Res"},{"key":"pone.0269313.ref018","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1515\/BMT.2007.052","article-title":"Ellbogendyplasie beim Hund: finite-elemente-analyse","volume":"52","author":"A Polikeit","year":"2007","journal-title":"Biomedizinische Technik"},{"key":"pone.0269313.ref019","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1111\/os.12368","article-title":"Biomechanical analysis of a novel intercalary prosthesis for humeral diaphyseal segmental defect reconstruction","volume":"10","author":"L Zhao","year":"2018","journal-title":"Orthop Surg"},{"key":"pone.0269313.ref020","doi-asserted-by":"crossref","first-page":"453","DOI":"10.3415\/VCOT-17-01-0015","article-title":"Locking T-plate repair of ilial fractures in cats and small dogs","volume":"30","author":"A Scrimgeour","year":"2017","journal-title":"Vet Comp Orthop Traumatol"},{"key":"pone.0269313.ref021","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1111\/jsap.12803","article-title":"Tibial plateau levelling osteotomy locking-compression plates for stabilization of canine and feline ilial body fractures","volume":"59","author":"JW Guthrie","year":"2017","journal-title":"J Small Anim Pract"},{"key":"pone.0269313.ref022","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1111\/j.1532-950X.2011.00913.x","article-title":"Comparison of the mechanical behaviors of locked and nonlocked plate\/screw fixation applied to experimentally induced rotational osteotomies in canine ilia","volume":"41","author":"JB Case","year":"2011","journal-title":"Vet Surg"},{"key":"pone.0269313.ref023","article-title":"Engineering high resolution micropatterns directly onto titanium with optimized contact guidance to promote osteogenic differentiation and bon\u00e9 regeneration","author":"M Zhu","year":"2019","journal-title":"ACS Applied Materials & Interfaces"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0269313","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,26]],"date-time":"2022-08-26T17:44:33Z","timestamp":1661535873000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0269313"}},"subtitle":[],"editor":[{"given":"Carlos E.","family":"Ambr\u00f3sio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,8,26]]},"references-count":23,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,8,26]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0269313","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,26]]}}}