{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T17:42:58Z","timestamp":1772214178533,"version":"3.50.1"},"reference-count":13,"publisher":"Public Library of Science (PLoS)","issue":"3","license":[{"start":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T00:00:00Z","timestamp":1678147200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100001818","name":"Research to Prevent Blindness","doi-asserted-by":"publisher","award":["Unrestricted Grant"],"award-info":[{"award-number":["Unrestricted Grant"]}],"id":[{"id":"10.13039\/100001818","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Institutes of Health, National Eye Institute","award":["R01-EY013178"],"award-info":[{"award-number":["R01-EY013178"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>This study was registered with ClinicalTrials.gov (ID: NCT03715231). A total of 20 participants (37 eyes) who were 18 or older and had glaucoma or were glaucoma suspects were enrolled from the NYU Langone Eye Center and Bellevue Hospital. During their usual ophthalmology visit, they were consented for the study and underwent 360-degree goniophotography using the NIDEK Gonioscope GS-1. Afterwards, the three ophthalmologists separately examined the images obtained and determined the status of the iridocorneal angle in four quadrants using the Shaffer grading system. Physicians were masked to patient names and diagnoses. Inter-observer reproducibility was determined using Fleiss\u2019 kappa statistics. The interobserver reliability using Fleiss\u2019 statistics was shown to be significant between three glaucoma specialists with fair overall agreement (Fleiss\u2019 kappa: 0.266, p &lt; .0001) in the interpretation of 360-degree goniophotos. Automated 360-degree goniophotography using the NIDEK Gonioscope GS-1 have quality such that they are interpreted similarly by independent expert observers. This indicates that angle investigation may be performed using this automated device and that interpretation by expert observers is likely to be similar. Images produced from automated 360-degree goniophotography using the NIDEK Gonioscope GS-1 are similarly interpreted amongst glaucoma specialists, thus supporting use of this technique to document and assess the anterior chamber angle in patients with, or suspected of, glaucoma and iridocorneal angle abnormalities.<\/jats:p>","DOI":"10.1371\/journal.pone.0270941","type":"journal-article","created":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T13:27:15Z","timestamp":1678195635000},"page":"e0270941","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":2,"title":["Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma"],"prefix":"10.1371","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8265-9543","authenticated-orcid":true,"given":"Chisom T.","family":"Madu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taylor","family":"Phelps","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8885-3766","authenticated-orcid":true,"given":"Joel S.","family":"Schuman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald","family":"Zambrano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ting-Fang","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Panarelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lama","family":"Al-Aswad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gadi","family":"Wollstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2023,3,7]]},"reference":[{"issue":"2","key":"pone.0270941.ref001","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1111\/opo.12200","article-title":"Repeatability and comparison of clinical techniques for anterior chamber angle assessment","volume":"35","author":"P Campbell","year":"2015","journal-title":"Ophthalmic Physiol Opt"},{"issue":"1","key":"pone.0270941.ref002","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1177\/1120672118806436","article-title":"Automated gonioscopy photography for iridocorneal angle grading.","volume":"30","author":"F Teixeira","year":"2020","journal-title":"Eur J Ophthalmol"},{"issue":"5","key":"pone.0270941.ref003","doi-asserted-by":"crossref","first-page":"e0251249","DOI":"10.1371\/journal.pone.0251249","article-title":"Intraobserver and interobserver agreement among anterior chamber angle evaluations using automated 360-degree gonio-photos.","volume":"16","author":"M Matsuo","year":"2021","journal-title":"PLoS One"},{"issue":"6","key":"pone.0270941.ref004","first-page":"529","article-title":"Stereoscopic Manual of Gonioscopy","volume":"38","author":"RN Shaffer","year":"1963","journal-title":"Academic Medicine"},{"issue":"5","key":"pone.0270941.ref005","doi-asserted-by":"crossref","first-page":"16-","DOI":"10.1167\/tvst.8.5.16","article-title":"Remote Grading of the Anterior Chamber Angle Using Goniophotographs and Optical Coherence Tomography: Implications for Telemedicine or Virtual Clinics.","volume":"8","author":"J Phu","year":"2019","journal-title":"Transl Vis Sci Technol"},{"issue":"5","key":"pone.0270941.ref006","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1037\/0033-2909.86.5.974","article-title":"Large sample variance of kappa in the case of different sets of rater","volume":"86","author":"JL Fleiss","year":"1979","journal-title":"Psychol Bull"},{"issue":"1","key":"pone.0270941.ref007","first-page":"54","article-title":"Bootstrap Methods for Standard Errors, Confidence Intervals, and Other Measures of Statistical Accuracy","volume":"1","author":"B Efron","year":"1986","journal-title":"Stat Sci"},{"key":"pone.0270941.ref008","volume-title":"Practical statistics for medical research","author":"DG Altman","year":"1991"},{"issue":"1","key":"pone.0270941.ref009","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The Measurement of Observer Agreement for Categorical Data","volume":"33","author":"JR Landis","year":"1977","journal-title":"Biometrics"},{"issue":"3","key":"pone.0270941.ref010","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1093\/ptj\/85.3.257","article-title":"The Kappa Statistic in Reliability Studies: Use, Interpretation, and Sample Size Requirements","volume":"85","author":"J Sim","year":"2005","journal-title":"Physical Therapy"},{"key":"pone.0270941.ref011","doi-asserted-by":"crossref","first-page":"1727039","DOI":"10.1155\/2016\/1727039","article-title":"Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging","volume":"2016","author":"M Rigi","year":"2016","journal-title":"J Ophthalmol"},{"issue":"13","key":"pone.0270941.ref012","first-page":"4836-","article-title":"A new 3-Dimensional (3D) method for assessment of the anterior chamber angle","volume":"55","author":"D Wang","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"pone.0270941.ref013","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1136\/bjo.2006.103408","article-title":"Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?","volume":"91","author":"A Konstantopoulos","year":"2007","journal-title":"Br J Ophthalmol"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0270941","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T13:27:31Z","timestamp":1678195651000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0270941"}},"subtitle":[],"editor":[{"given":"Gianni","family":"Virgili","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2023,3,7]]},"references-count":13,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,3,7]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0270941","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2022.06.22.22276741","asserted-by":"object"}]},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,7]]}}}