{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T08:27:28Z","timestamp":1765268848136,"version":"3.37.3"},"reference-count":64,"publisher":"Public Library of Science (PLoS)","issue":"7","license":[{"start":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T00:00:00Z","timestamp":1658361600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001843","name":"Science and Engineering Research Board","doi-asserted-by":"publisher","award":["SRG\/2019\/000235"],"award-info":[{"award-number":["SRG\/2019\/000235"]}],"id":[{"id":"10.13039\/501100001843","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Mechanobiology plays an essential role in secondary bone fracture healing. While the introduction of newer type of plates, e.g. locking plate (LP), is becoming increasingly popular for complex femoral fractures, the conventional technique involving dynamic compression plate (DCP) remains the standard choice. The difference between the two techniques lies primarily in their screw fixation mechanisms. The present study applied 3D dynamic fracture healing scheme modelled on a subtrochanteric femur fracture, regulated by both finite element (FE) analysis and Fuzzy logic control in order to understand the spatio-temporal healing phenomena for both LP and DCP. The study further examined the influence of the two screw fixation mechanisms in determining the comparative progression of fracture healing. The problem was solved iteratively in several healing steps running in loop and accordingly, the local tissue concentrations and material properties were updated. The predicted results accorded well with various previous experimental observations. The study found an initial delay in healing associated with DCP. However, as the healing progressed, there was no significant difference in overall callus modulus. The presented preclinical model may further help predict bone healing for different implantation techniques, and thus can serve as a non-invasive tool for evaluating relative merits of extramedullary plating techniques.<\/jats:p>","DOI":"10.1371\/journal.pone.0271061","type":"journal-article","created":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T17:53:11Z","timestamp":1658425991000},"page":"e0271061","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":6,"title":["A preclinical model of post-surgery secondary bone healing for subtrochanteric femoral fracture based on fuzzy interpretations"],"prefix":"10.1371","volume":"17","author":[{"given":"Pratik","family":"Nag","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4110-3191","authenticated-orcid":true,"given":"Souptick","family":"Chanda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2022,7,21]]},"reference":[{"issue":"2","key":"pone.0271061.ref001","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1177\/145749690609500205","article-title":"Current augmentation fixation techniques for the osteoporotic patient.","volume":"95","author":"A Moroni","year":"2006","journal-title":"Scand J Surg"},{"key":"pone.0271061.ref002","doi-asserted-by":"crossref","unstructured":"George C. Babis, Panayotis N. Soucacos, Bone scaffolds: The role of mechanical stability and instrumentation, Injury, Volume 36, Issue 4, Supplement,2005, Pages S38-S44, ISSN 0020-1383, https:\/\/doi.org\/10.1016\/j.injury.2005.10.009.","DOI":"10.1016\/j.injury.2005.10.009"},{"issue":"9","key":"pone.0271061.ref003","first-page":"439","article-title":"Has locked plating completely replaced conventional plating?","volume":"33","author":"MJ Gardner","year":"2004","journal-title":"Am J Orthop (Belle Mead NJ)."},{"issue":"1\u20132","key":"pone.0271061.ref004","first-page":"183","article-title":"Importance de la friction plaque-os pour l\u2019ancrage des plaques d\u2019ost\u00e9osynth\u00e8se. D\u00e9termination du coefficient de friction m\u00e9tal-os chez l\u2019animal \"in vivo\" [Importance of the friction between plate and bone in the anchoring of plates for osteosynthesis. Determination of the coefficient of metal-bone friction in animal in vivo].","volume":"46","author":"J Cordey","year":"1979","journal-title":"Helv Chir Acta."},{"issue":"138","key":"pone.0271061.ref005","first-page":"175","article-title":"Physical and biological aspects of fracture healing with special reference to internal fixation","author":"SM Perren","year":"1979","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"pone.0271061.ref006","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"SM Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"pone.0271061.ref007","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.medengphy.2010.02.014","article-title":"Biomechanical evaluation of a new system to improve screw fixation in osteoporotic bones.","volume":"32","author":"A Y\u00e1nez","year":"2010","journal-title":"Med Eng Phys"},{"key":"pone.0271061.ref008","first-page":"271","article-title":"New concepts for bone fracture treatment and the Locking Compression Plate","volume":"12","author":"M Wagner","year":"2004","journal-title":"Surg Technol Int"},{"issue":"8","key":"pone.0271061.ref009","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","article-title":"Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques.","volume":"21","author":"A Aminian","year":"2007","journal-title":"J Orthop Trauma."},{"issue":"9","key":"pone.0271061.ref010","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1097\/BOT.0b013e3181a2a31d","article-title":"A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.","volume":"23","author":"BD Crist","year":"2009","journal-title":"J Orthop Trauma."},{"issue":"9","key":"pone.0271061.ref011","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/BOT.0b013e3181b04835","article-title":"Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures.","volume":"23","author":"JC Floyd","year":"2009","journal-title":"J Orthop Trauma."},{"issue":"7","key":"pone.0271061.ref012","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1111\/j.1532-950X.2008.00433.x","article-title":"Mechanical comparison of 3.5 mm broad dynamic compression plate, broad limited-contact dynamic compression plate, and narrow locking compression plate systems using interfragmentary gap models.","volume":"37","author":"JM Uhl","year":"2008","journal-title":"Vet Surg"},{"issue":"355 Suppl","key":"pone.0271061.ref013","doi-asserted-by":"crossref","first-page":"S132","DOI":"10.1097\/00003086-199810001-00015","article-title":"Effects of mechanical factors on the fracture healing process","author":"LE Claes","year":"1998","journal-title":"Clinical Orthopaedics and Related Research"},{"issue":"3","key":"pone.0271061.ref014","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0021-9290(98)00153-5","article-title":"Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing","volume":"32","author":"LE Claes","year":"1999","journal-title":"J Biomech"},{"issue":"5","key":"pone.0271061.ref015","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1002\/jor.1100060517","article-title":"Correlations between mechanical stress history and tissue differentiation in initial fracture healing","volume":"6","author":"DR Carter","year":"1988","journal-title":"J Orthop Res"},{"issue":"3","key":"pone.0271061.ref016","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1002\/jor.1100070312","article-title":"Role of mechanical loading in the progressive ossification of a fracture callus","volume":"7","author":"PR Blenman","year":"1989","journal-title":"J Orthop Res"},{"issue":"1","key":"pone.0271061.ref017","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1002\/jor.1100090116","article-title":"Role of interfragmentary strain in fracture healing: ovine model of a healing osteotomy","volume":"9","author":"EJ Cheal","year":"1991","journal-title":"J Orthop Res"},{"issue":"8","key":"pone.0271061.ref018","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1016\/S0021-9290(00)00049-X","article-title":"A fuzzy logic model of fracture healing","volume":"33","author":"C Ament","year":"2000","journal-title":"J Biomech"},{"issue":"8","key":"pone.0271061.ref019","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1016\/S0021-9290(03)00117-9","article-title":"Beneficial effects of moderate, early loading and adverse effects of delayed or excessive loading on bone healing","volume":"36","author":"A Bail\u00f3n-Plaza","year":"2003","journal-title":"J Biomech"},{"issue":"3","key":"pone.0271061.ref020","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.jtbi.2008.07.003","article-title":"A mechano-regulatory bone-healing model incorporating cell-phenotype specific activity [published correction appears","volume":"254","author":"H Isaksson","year":"2008","journal-title":"J Theor Biol"},{"issue":"1","key":"pone.0271061.ref021","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.engfracmech.2003.08.003","article-title":"Modelling bone tissue fracture and healing: a review","volume":"71","author":"M Doblare","year":"2004","journal-title":"Eng Fract Mech"},{"issue":"9","key":"pone.0271061.ref022","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading","volume":"35","author":"D Lacroix","year":"2002","journal-title":"J Biomech"},{"issue":"5","key":"pone.0271061.ref023","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1080\/1025584021000025014","article-title":"Three-dimensional simulation of fracture repair in the human tibia","volume":"5","author":"D Lacroix","year":"2002","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"7","key":"pone.0271061.ref024","doi-asserted-by":"crossref","first-page":"1467","DOI":"10.1016\/j.jbiomech.2006.06.013","article-title":"Computational simulation of fracture healing: influence of interfragmentary movement on the callus growth","volume":"40","author":"JM Garc\u00eda-Aznar","year":"2007","journal-title":"J Biomech"},{"key":"pone.0271061.ref025","unstructured":"Kuiper JH, Ashton BA, Richardson JB. Computer simulation of fracture callus formation and stiffness restoration. In: Proceedings of the 12th Conference of the European Society of Biomechanics; Dublin. p. 61."},{"issue":"2","key":"pone.0271061.ref026","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1006\/jtbi.2001.2372","article-title":"A mathematical framework to study the effects of growth factor influences on fracture healing","volume":"212","author":"A Bail\u00f3n-Plaza","year":"2001","journal-title":"J Theor Biol"},{"issue":"1","key":"pone.0271061.ref027","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.jtbi.2007.11.008","article-title":"Angiogenesis in bone fracture healing: a bioregulatory model","volume":"251","author":"L Geris","year":"2008","journal-title":"J Theor Biol"},{"key":"pone.0271061.ref028","article-title":"Simulation of tissue development and vascularization in the callus healing process","author":"U Simon","year":"2003","journal-title":"Transactions ORS"},{"issue":"12","key":"pone.0271061.ref029","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.1016\/j.jbiomech.2004.10.019","article-title":"Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic","volume":"38","author":"SJ Shefelbine","year":"2005","journal-title":"J Biomech"},{"issue":"1","key":"pone.0271061.ref030","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1080\/10255842.2010.499865","article-title":"A numerical model of the fracture healing process that describes tissue development and revascularisation","volume":"14","author":"U Simon","year":"2011","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"1","key":"pone.0271061.ref031","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1053\/j.jfas.2006.09.009","article-title":"Fixation of osteoporotic distal fibula fractures: A biomechanical comparison of locking versus conventional plates.","volume":"46","author":"T Kim","year":"2007","journal-title":"J Foot Ankle Surg"},{"issue":"2","key":"pone.0271061.ref032","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.clinbiomech.2006.08.009","article-title":"Locked vs. unlocked plate osteosynthesis of the proximal humerus\u2014a biomechanical study.","volume":"22","author":"K Seide","year":"2007","journal-title":"Clin Biomech (Bristol, Avon)."},{"issue":"16","key":"pone.0271061.ref033","doi-asserted-by":"crossref","first-page":"1818","DOI":"10.1080\/10255842.2014.974580","article-title":"Reasons why dynamic compression plates are inferior to locking plates in osteoporotic bone: a finite element explanation","volume":"18","author":"AR MacLeod","year":"2015","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"9","key":"pone.0271061.ref034","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1016\/j.compstruct.2009.09.051","article-title":"The finite element analysis of a fractured tibia applied by composite bone plates considering contact conditions and time-varying properties of curing tissues","volume":"92","author":"SH Kim","year":"2010","journal-title":"Compos Struct"},{"issue":"3","key":"pone.0271061.ref035","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/1350-4533(95)00041-0","article-title":"Finite element stress analysis of a hybrid fracture fixation plate.","volume":"18","author":"SJ Ferguson","year":"1996","journal-title":"Med Eng Phys"},{"issue":"3","key":"pone.0271061.ref036","first-page":"466","article-title":"Stresses in plated long-bones: the role of screw tightness and interface slipping [published correction appears","volume":"6","author":"GS Beaupr\u00e9","year":"1988","journal-title":"J Orthop Res"},{"issue":"6","key":"pone.0271061.ref037","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1016\/j.clinbiomech.2010.03.003","article-title":"Influence of the fixation stability on the healing time\u2014a numerical study of a patient-specific fracture healing process.","volume":"25","author":"T Wehner","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)."},{"issue":"2","key":"pone.0271061.ref038","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s11517-020-02306-6","article-title":"Biomechanical design prognosis of two extramedullary fixation devices for subtrochanteric femur fracture: a finite element study","volume":"59","author":"P Nag","year":"2021","journal-title":"Med Biol Eng Comput"},{"key":"pone.0271061.ref039","unstructured":"ISO\u2014ISO 7206\u20134:2010\u2014Implants for surgery\u2014partial and total hip joint prostheses\u2014part 4: determination of endurance properties and performance of stemmed femoral components. https:\/\/www.iso.org\/standard\/42769.html. (Accessed 14 Apr 2021)."},{"issue":"7","key":"pone.0271061.ref040","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","article-title":"Hip contact forces and gait patterns from routine activities","volume":"34","author":"G Bergmann","year":"2001","journal-title":"J Biomech"},{"issue":"7","key":"pone.0271061.ref041","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/S0021-9290(01)00039-2","article-title":"Musculo-skeletal loading conditions at the hip during walking and stair climbing","volume":"34","author":"MO Heller","year":"2001","journal-title":"J Biomech"},{"issue":"5","key":"pone.0271061.ref042","first-page":"43","article-title":"Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation [published correction appears","volume":"25","author":"A. Gefen","year":"2003","journal-title":"Med Eng Phys."},{"issue":"10","key":"pone.0271061.ref043","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.injury.2011.02.012","article-title":"Can DCP and LCP plates generate more compression? The effect of multiple eccentrically placed screws and their drill positioning guides.","volume":"42","author":"FM Ya\u2019ish","year":"2011","journal-title":"Injury"},{"issue":"5","key":"pone.0271061.ref044","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/0021-9290(83)90014-3","article-title":"Fatigue failure of cortical bone screws","volume":"16","author":"MS Zand","year":"1983","journal-title":"J Biomech"},{"key":"pone.0271061.ref045","unstructured":"Biomechanical products catalog Sawbones: Test materials and composite bones. https:\/\/www.sawbones.com\/media\/assets\/product\/documents\/biomechanical_catalog2020.pdf. (Accessed 7 Dec 2020)."},{"key":"pone.0271061.ref046","first-page":"276","article-title":"Prediction of tissue differentiation during fracture healing- influence of mechanical loading","author":"D Lacroix","year":"1999","journal-title":"Proceedings of the American Society of Biomechanics."},{"key":"pone.0271061.ref047","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1007\/BF00523401","article-title":"Eine neue Theorie \u00fcber den Einflu\u00df mechanischer Reize auf die Differenzierung der St\u00fctzgewebe.","volume":"121","author":"F. Pauwels","year":"1960","journal-title":"Zeitschrift f\u00fcr Anatomie und Entwicklungsgeschichte."},{"key":"pone.0271061.ref048","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0020-7373(75)80002-2","article-title":"An Experiment in Linguistic Synthesis with a Fuzzy Logic Controller","author":"E.H. Mamdani","year":"1975","journal-title":"International Journal of Man-Machine Studies"},{"key":"pone.0271061.ref049","doi-asserted-by":"crossref","unstructured":"L.A. Zadeh, Fuzzy sets, Information and Control, Volume 8, Issue 3, 1965, Pages 338\u2013353, ISSN 0019-9958, https:\/\/doi.org\/10.1016\/S0019-9958(65)90241-X.","DOI":"10.1016\/S0019-9958(65)90241-X"},{"issue":"1","key":"pone.0271061.ref050","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S0021-9290(99)00171-2","article-title":"Dynamic cell stretching increases human osteoblast proliferation and CICP synthesis but decreases osteocalcin synthesis and alkaline phosphatase activity","volume":"33","author":"D Kaspar","year":"2000","journal-title":"J Biomech"},{"issue":"105","key":"pone.0271061.ref051","first-page":"34","article-title":"Tibial blood supply in relation to fracture healing","author":"FW Rhinelander","year":"1974","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"pone.0271061.ref052","first-page":"275","article-title":"Histomorphologie und Vaskularisation der sekund\u00e4ren Knochenbruchheilung, unter besonderer Ber\u00fccksichtigung der Tibiaschaftfraktur [Histomorphology and vascularization of secondary healing of bone fractures with emphasis on tibial shaft fractures (author\u2019s transl)].","volume":"80","author":"L Schweiberer","year":"1977","journal-title":"Unfallheilkunde"},{"issue":"5","key":"pone.0271061.ref053","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/S0736-0266(02)00044-X","article-title":"The effect of mechanical stability on local vascularization and tissue differentiation in callus healing","volume":"20","author":"L Claes","year":"2002","journal-title":"J Orthop Res"},{"issue":"355 Suppl","key":"pone.0271061.ref054","doi-asserted-by":"crossref","first-page":"S7","DOI":"10.1097\/00003086-199810001-00003","article-title":"The cell and molecular biology of fracture healing","author":"TA Einhorn","year":"1998","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"pone.0271061.ref055","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.injury.2011.03.031","article-title":"The biology of fracture healing","volume":"42","author":"R Marsell","year":"2011","journal-title":"Injury"},{"issue":"3","key":"pone.0271061.ref056","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.","volume":"24","author":"TJ Lujan","year":"2010","journal-title":"J Orthop Trauma"},{"issue":"232","key":"pone.0271061.ref057","first-page":"139","article-title":"Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection?","author":"SM Perren","year":"1988","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"pone.0271061.ref058","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/S1350-4533(03)00036-5","article-title":"The biomechanical environment of a bone fracture and its influence upon the morphology of healing","volume":"25","author":"TN Gardner","year":"2003","journal-title":"Med Eng Phys"},{"issue":"4","key":"pone.0271061.ref059","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1002\/jor.1100150414","article-title":"Influence of size and stability of the osteotomy gap on the success of fracture healing","volume":"15","author":"L Claes","year":"1997","journal-title":"J Orthop Res"},{"journal-title":"Bone Rep","article-title":"The investigation of bone fracture healing under intramembranous and endochondral ossification","author":"S Ghimire","key":"pone.0271061.ref060"},{"issue":"1","key":"pone.0271061.ref061","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1302\/0301-620X.64B1.7040407","article-title":"The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials","volume":"64","author":"K Tayton","year":"1982","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"pone.0271061.ref062","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.67B4.4030869","article-title":"The influence of induced micromovement upon the healing of experimental tibial fractures","volume":"67","author":"AE Goodship","year":"1985","journal-title":"J Bone Joint Surg Br"},{"issue":"9","key":"pone.0271061.ref063","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading","volume":"35","author":"D Lacroix","year":"2002","journal-title":"J Biomech"},{"issue":"4","key":"pone.0271061.ref064","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1002\/jor.1100150414","article-title":"Influence of size and stability of the osteotomy gap on the success of fracture healing","volume":"15","author":"L Claes","year":"1997","journal-title":"J Orthop Res"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0271061","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T17:54:28Z","timestamp":1658426068000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0271061"}},"subtitle":[],"editor":[{"given":"Yiming","family":"Tang","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,7,21]]},"references-count":64,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2022,7,21]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0271061","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2022,7,21]]}}}