{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T21:38:07Z","timestamp":1783114687089,"version":"3.54.6"},"reference-count":39,"publisher":"Public Library of Science (PLoS)","issue":"8","license":[{"start":{"date-parts":[[2022,8,11]],"date-time":"2022-08-11T00:00:00Z","timestamp":1660176000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"MEDEL","award":["The study was sponsored by MED-EL Elektromedizinische Ger\u00e4te GmbH, Innsbruck, Austria"],"award-info":[{"award-number":["The study was sponsored by MED-EL Elektromedizinische Ger\u00e4te GmbH, Innsbruck, Austria"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Human stapedius muscle (SM) can be directly and safely accessed via retrofacial approach, opening new approaches to directly measure the electrically evoked stapedius reflex threshold (eSRT). The measurement of the SM activity via direct surgical access represents a potential tool for objective eSRT fitting of cochlear implants (CI), increasing the benefit experienced by the CI users and leading to new perspectives in the development of smart implantable neurostimulators. 3D middle-ear reconstructions created after manual segmentation and related SM accessibility metrics were evaluated before the CI surgery for 16 candidates with assessed stapedius reflex. Retrofacial approach to access the SM was performed after facial recess exposure. In cases of poor exposition of SM, the access was performed anteriorly to the FN via drilling of the pyramidal eminence (PE). The total access rate of the SM via both the retrofacial and anterior approach of the FN was 100%. In 81.2% of cases (13\/16), the retrofacial approach allowed to access the SM on previously categorized well exposed (8\/8), partially exposed (4\/5), and wholly concealed (1\/3) SM with respect to FN. Following intraoperative evaluation in the remaining 18.8% (3\/16), the SM was accessed anteriorly via drilling of the PE. Exposure of SM with respect to the FN and the sigmoid sinus\u2019s prominence was a predictor for the suitable surgical approach. The retrofacial approach offers feasible and reproducible access to the SM belly, opening direct access to electromyographic sensing of the eSRT. Surgical planner tools can quantitatively assist pre-surgical assessment.<\/jats:p>","DOI":"10.1371\/journal.pone.0272943","type":"journal-article","created":{"date-parts":[[2022,8,11]],"date-time":"2022-08-11T17:30:15Z","timestamp":1660239015000},"page":"e0272943","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":5,"title":["Accessing the stapedius muscle via novel surgical retrofacial approach during cochlear implantation surgery: Intraoperative results on feasibility and safety"],"prefix":"10.1371","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9671-0784","authenticated-orcid":true,"given":"Orlando","family":"Guntinas-Lichius","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Arnold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd Fabian","family":"Volk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Korth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rene","family":"Aschenbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9647-5136","authenticated-orcid":true,"given":"Johann-Martin","family":"Hempel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fritz","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4724-2440","authenticated-orcid":true,"given":"Thore","family":"Schade-Mann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Gamerdinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anke","family":"Tropitzsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hubert","family":"L\u00f6wenheim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2022,8,11]]},"reference":[{"issue":"1","key":"pone.0272943.ref001","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/00206090009073049","article-title":"Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants","volume":"39","author":"K Stephan","year":"2000","journal-title":"Audiology"},{"issue":"Suppl 1","key":"pone.0272943.ref002","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1179\/146701010X12671177204741","article-title":"ESRT, ART, and MCL correlations in experienced paediatric cochlear implant users","volume":"11","author":"A Walkowiak","year":"2010","journal-title":"Cochlear Implants Int"},{"key":"pone.0272943.ref003","doi-asserted-by":"crossref","first-page":"501738","DOI":"10.1155\/2014\/501738","article-title":"Cochlear Implant Programming: A Global Survey on the State of the Art","volume":"2014","author":"B Vaerenberg","year":"2014","journal-title":"The Scientific World Journal"},{"issue":"1","key":"pone.0272943.ref004","first-page":"68","article-title":"The importance of electrically evoked stapedial reflex in cochlear implant","volume":"80","author":"KC Andrade","year":"2014","journal-title":"Braz J Otorhinolaryngol"},{"issue":"12","key":"pone.0272943.ref005","doi-asserted-by":"crossref","first-page":"2811","DOI":"10.1016\/j.clinph.2004.06.024","article-title":"Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting","volume":"115","author":"H Thai-Van","year":"2004","journal-title":"Clin Neurophysiol"},{"issue":"1","key":"pone.0272943.ref006","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1179\/1754762814Y.0000000082","article-title":"The relationship between electrical auditory brainstem responses and perceptual thresholds in Digisonic(R) SP cochlear implant users","volume":"16","author":"G Guenser","year":"2015","journal-title":"Cochlear Implants Int"},{"issue":"1","key":"pone.0272943.ref007","first-page":"62","article-title":"The Use of ESRT in Fitting Children with Cochlear Implants","volume":"5","author":"J Kosaner","year":"2009","journal-title":"Int Adv Otol"},{"issue":"12","key":"pone.0272943.ref008","doi-asserted-by":"crossref","first-page":"4167","DOI":"10.1007\/s00405-016-4115-1","article-title":"Maps created using a new objective procedure (C-NRT) correlate with behavioral, loudness-balanced maps: a study in adult cochlear implant users","volume":"273","author":"A Scorpecci","year":"2016","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"pone.0272943.ref009","doi-asserted-by":"crossref","first-page":"8","DOI":"10.5152\/iao.2019.6589","article-title":"The Relationship between Electrical Stapedius Reflex Thresholds and Behaviorally Most Comfortable Levels in Experienced Cochlear Implant Users","volume":"16","author":"A \u00c7iprut","year":"2020","journal-title":"J Int Adv Otol"},{"key":"pone.0272943.ref010","article-title":"Stapedius refelx tests in cochlear implantation","author":"K Stephan","year":"1992","journal-title":"First International Symposium on Objective Measures Nottingham"},{"issue":"4","key":"pone.0272943.ref011","doi-asserted-by":"crossref","first-page":"201","DOI":"10.15406\/joentr.2019.11.00435","article-title":"Correlation between behaviorally measured comfort (c) levels and electrically evoked stapedius reflex thresholds (ESRT) in children with unilateral cochlear implant","volume":"11","author":"R Mishra","year":"2019","journal-title":"J Otolaryngol ENT Res"},{"issue":"3 Pt 1","key":"pone.0272943.ref012","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0194-5998(97)70183-9","article-title":"Electrical middle ear muscle reflex: use in cochlear implant programming","volume":"117","author":"AV Hodges","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"3","key":"pone.0272943.ref013","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1179\/1754762814Y.0000000064","article-title":"A clinical study of electrophysiological correlates of behavioural comfort levels in cochlear implantees","volume":"15","author":"S Raghunandhan","year":"2014","journal-title":"Cochlear Implants Int"},{"issue":"1","key":"pone.0272943.ref014","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1080\/14670100.2004.11873748","article-title":"ESRT and MCL correlations in experienced paediatric cochlear implant users","volume":"5","author":"A Lorens","year":"2004","journal-title":"Cochlear Implants Int"},{"issue":"Suppl 1","key":"pone.0272943.ref015","doi-asserted-by":"crossref","first-page":"43S","DOI":"10.1097\/AUD.0b013e31829c70d9","article-title":"Acoustic reflex measurement","volume":"34","author":"KS Schairer","year":"2013","journal-title":"Ear Hear"},{"issue":"1","key":"pone.0272943.ref016","first-page":"59","article-title":"Anatomical variations and anomalies of the musculus stapedius tendon. Study by scanning electron microscopy","volume":"104","author":"D Djeric","year":"1987","journal-title":"Ann Otolaryngol Chir Cervicofac"},{"issue":"2","key":"pone.0272943.ref017","first-page":"112","article-title":"Absence of both stapedius tendon and muscle","volume":"11","author":"C Kopuz","year":"2006","journal-title":"Neurosciences (Riyadh)"},{"key":"pone.0272943.ref018","article-title":"Accessing the stapedius muscle via novel surgical retrofacial approach: A cadaveric feasibility study\u2014In press","author":"D Arnold","year":"2021","journal-title":"Otol Neurotol\u2014accepted"},{"issue":"4","key":"pone.0272943.ref019","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1007\/s00405-019-05773-2","article-title":"Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study","volume":"277","author":"GF Volk","year":"2020","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"2","key":"pone.0272943.ref020","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s11548-020-02288-8","article-title":"The use of a surgical planning tool for evaluating the optimal surgical accessibility to the stapedius muscle via a retrofacial approach during cochlear implant surgery: a feasibility study","volume":"16","author":"P Marquez","year":"2021","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"pone.0272943.ref021","doi-asserted-by":"crossref","first-page":"85","DOI":"10.4103\/0301-4738.77005","article-title":"How to choose the right statistical test?","volume":"59","author":"BK Nayak","year":"2011","journal-title":"Indian J Ophthalmol"},{"issue":"6","key":"pone.0272943.ref022","first-page":"741","article-title":"Sinus tympani: anatomic considerations, computed tomography, and a discussion of the retrofacial approach for removal of disease","volume":"16","author":"BP Pickett","year":"1995","journal-title":"The American journal of otology"},{"issue":"1","key":"pone.0272943.ref023","first-page":"1","article-title":"Retrofacial approach for the removal of a cholesteatoma from the sinus tympani","volume":"51","author":"H Kawano","year":"2005","journal-title":"jibi to rinsho"},{"issue":"3","key":"pone.0272943.ref024","doi-asserted-by":"crossref","first-page":"e79","DOI":"10.1097\/MAO.0000000000000648","article-title":"Retrofacial approach to access the round window for cochlear implantation of malformed ears","volume":"36","author":"H Rizk","year":"2015","journal-title":"Otology & neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology"},{"issue":"3","key":"pone.0272943.ref025","doi-asserted-by":"crossref","first-page":"e84","DOI":"10.1097\/MAO.0000000000000687","article-title":"Cochlear implantation requiring a retrofacial approach to the round window","volume":"36","author":"KP Allen","year":"2015","journal-title":"Otol Neurotol"},{"issue":"7","key":"pone.0272943.ref026","doi-asserted-by":"crossref","first-page":"e550","DOI":"10.1097\/MAO.0000000000001878","article-title":"The Feasibility of Retrofacial Approach for Cochlear Implantation","volume":"39","author":"R Yilmazer","year":"2018","journal-title":"Otology & neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology"},{"issue":"2","key":"pone.0272943.ref027","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.anl.2018.08.012","article-title":"Vibrant Soundbridge implantation via a retrofacial approach in a patient with congenital aural atresia","volume":"46","author":"R Ikeda","year":"2019","journal-title":"Auris Nasus Larynx"},{"issue":"6","key":"pone.0272943.ref028","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1080\/00016489.2020.1725113","article-title":"Location of the stapedius muscle with reference to the facial nerve in patients with unilateral congenital aural atresia: implication for active middle ear implants surgery","volume":"140","author":"R Ikeda","year":"2020","journal-title":"Acta Otolaryngol"},{"key":"pone.0272943.ref029","doi-asserted-by":"crossref","first-page":"641581","DOI":"10.3389\/fsurg.2021.641581","article-title":"Forensic Implications of Anatomical Education and Surgical Training With Cadavers","volume":"8","author":"C Pirri","year":"2021","journal-title":"Front Surg"},{"issue":"2","key":"pone.0272943.ref030","doi-asserted-by":"crossref","first-page":"279","DOI":"10.21608\/mjmu.2008.129203","article-title":"Morphologial features of the stapedius muscle in man","volume":"37","author":"T Haberkamp","year":"2008","journal-title":"Mansoura Medical Journal"},{"issue":"3","key":"pone.0272943.ref031","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1177\/0194599820915458","article-title":"Additional Benefits of Facial Nerve Monitoring during Otologic Surgery","volume":"163","author":"K Casano","year":"2020","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"4","key":"pone.0272943.ref032","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1007\/s00405-020-06171-9","article-title":"Evaluating the didactic value of 3D visualization in otosurgery","volume":"278","author":"NM Weiss","year":"2021","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"pone.0272943.ref033","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/MAO.0b013e31818a0898","article-title":"Electromyographical recording of the electrically elicited stapedius reflex via a bipolar hook electrode","volume":"30","author":"HW Pau","year":"2009","journal-title":"Otology & neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology"},{"issue":"3","key":"pone.0272943.ref034","doi-asserted-by":"crossref","first-page":"146","DOI":"10.3109\/00206090009073067","article-title":"Objective intraoperative method to record averaged electromyographic stapedius muscle reflexes in cochlear implant patients","volume":"39","author":"B Almqvist","year":"2000","journal-title":"Audiology"},{"key":"pone.0272943.ref035","doi-asserted-by":"crossref","first-page":"108290","DOI":"10.1016\/j.heares.2021.108290","article-title":"Intraoperative recordings of electromyogenic responses from the human stapedius muscle","volume":"408","author":"A Zarowski","year":"2021","journal-title":"Hear Res"},{"issue":"3","key":"pone.0272943.ref036","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1111\/j.1469-7580.2009.01105.x","article-title":"Development of the stapedius muscle and pyramidal eminence in humans","volume":"215","author":"JF Rodriguez-Vazquez","year":"2009","journal-title":"J Anat"},{"key":"pone.0272943.ref037","doi-asserted-by":"crossref","first-page":"103556","DOI":"10.1016\/j.mod.2019.103556","article-title":"Single origin of the epithelium of the human middle ear","volume":"158","author":"HF van Waegeningh","year":"2019","journal-title":"Mech Dev"},{"issue":"5","key":"pone.0272943.ref038","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1097\/MAO.0b013e318068b298","article-title":"Surgical anatomy of anterior and retrofacial approaches to sinus tympani","volume":"28","author":"CE Cesario de Abreu","year":"2007","journal-title":"Otol Neurotol"},{"issue":"1","key":"pone.0272943.ref039","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.1097\/MAO.0000000000001611","article-title":"An Objective Method to determine the electrically evoked stapedius reflex threshold during cochlea implantation","volume":"39","author":"BG Weiss","year":"2018","journal-title":"Otol Neurotol"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0272943","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,11]],"date-time":"2022-08-11T17:31:00Z","timestamp":1660239060000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0272943"}},"subtitle":[],"editor":[{"given":"Adrien A.","family":"Eshraghi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,8,11]]},"references-count":39,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,8,11]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0272943","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,11]]}}}