{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:06:31Z","timestamp":1790787991673,"version":"4.1.0"},"reference-count":82,"publisher":"Public Library of Science (PLoS)","issue":"11","license":[{"start":{"date-parts":[[2022,11,18]],"date-time":"2022-11-18T00:00:00Z","timestamp":1668729600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"labex smart","award":["ANR-11-IDEX-0004-02"],"award-info":[{"award-number":["ANR-11-IDEX-0004-02"]}]},{"name":"IUIS Sorbonne Universit\u00e9"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>After a major upper limb amputation, the use of myoelectric prosthesis as assistive devices is possible. However, these prostheses remain quite difficult to control for grasping and manipulation of daily life objects. The aim of the present observational case study is to document the kinematics of grasping in a group of 10 below-elbow amputated patients fitted with a myoelectric prosthesis in order to describe and better understand their compensatory strategies. They performed a grasping to lift task toward 3 objects (a mug, a cylinder and a cone) placed at two distances within the reaching area in front of the patients. The kinematics of the trunk and upper-limb on the non-amputated and prosthetic sides were recorded with 3 electromagnetic Polhemus sensors placed on the hand, the forearm (or the corresponding site on the prosthesis) and the ipsilateral acromion. The 3D position of the elbow joint and the shoulder and elbow angles were calculated thanks to a preliminary calibration of the sensor position. We examined first the effect of side, distance and objects with non-parametric statistics. Prosthetic grasping was characterized by severe temporo-spatial impairments consistent with previous clinical or kinematic observations. The grasping phase was prolonged and the reaching and grasping components uncoupled. The 3D hand displacement was symmetrical in average, but with some differences according to the objects. Compensatory strategies involved the trunk and the proximal part of the upper-limb, as shown by a greater 3D displacement of the elbow for close target and a greater forward displacement of the acromion, particularly for far targets. The hand orientation at the time of grasping showed marked side differences with a more frontal azimuth, and a more \u201cthumb-up\u201d roll. The variation of hand orientation with the object on the prosthetic side, suggested that the lack of finger and wrist mobility imposed some adaptation of hand pose relative to the object. The detailed kinematic analysis allows more insight into the mechanisms of the compensatory strategies that could be due to both increased distal or proximal kinematic constraints. A better knowledge of those compensatory strategies is important for the prevention of musculoskeletal disorders and the development of innovative prosthetics.<\/jats:p>","DOI":"10.1371\/journal.pone.0277917","type":"journal-article","created":{"date-parts":[[2022,11,18]],"date-time":"2022-11-18T13:24:06Z","timestamp":1668777846000},"page":"e0277917","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":13,"title":["Kinematic analysis of impairments and compensatory motor behavior during prosthetic grasping in below-elbow amputees"],"prefix":"10.1371","volume":"17","author":[{"given":"Am\u00e9lie","family":"Touillet","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8535-4267","authenticated-orcid":true,"given":"Adrienne","family":"Gouzien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Badin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierrick","family":"Herbe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"No\u00ebl","family":"Martinet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathana\u00ebl","family":"Jarrass\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6196-7229","authenticated-orcid":true,"given":"Agn\u00e8s","family":"Roby-Brami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2022,11,18]]},"reference":[{"issue":"1","key":"pone.0277917.ref001","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1186\/s12984-016-0197-7","article-title":"Learning to use a body-powered prosthesis: changes in functionality and kinematics","volume":"13","author":"LH Huinink","year":"2016","journal-title":"J Neuroeng Rehabil"},{"issue":"3","key":"pone.0277917.ref002","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1302\/0301-620X.37B3.506","article-title":"The use of myo-electric currents in the operation of prostheses","volume":"37-B","author":"CK Battye","year":"1955","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"pone.0277917.ref003","doi-asserted-by":"crossref","DOI":"10.1007\/s40137-013-0044-8","article-title":"Prosthetic Myoelectric Control Strategies: A Clinical Perspective","volume":"2","author":"A Roche","year":"2014","journal-title":"Current Surgery Reports"},{"key":"pone.0277917.ref004","doi-asserted-by":"crossref","first-page":"22","DOI":"10.3389\/fnbot.2014.00022","article-title":"Proceedings of the first workshop on Peripheral Machine Interfaces: going beyond traditional surface electromyography","volume":"8","author":"C Castellini","year":"2014","journal-title":"Front Neurorobot"},{"issue":"12","key":"pone.0277917.ref005","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/PHM.0b013e3181587f6c","article-title":"Upper-limb prosthetics: critical factors in device abandonment","volume":"86","author":"E Biddiss","year":"2007","journal-title":"Am J Phys Med Rehabil"},{"issue":"6","key":"pone.0277917.ref006","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1682\/JRRD.2010.08.0161","article-title":"Myoelectric forearm prostheses: state of the art from a usercentered perspective","volume":"48","author":"B Peerdeman","year":"2011","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"pone.0277917.ref007","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.neulet.2006.06.047","article-title":"Peripheral neuropathy and object length perception by effortful (dynamic) touch: a case study","volume":"405","author":"C Carello","year":"2006","journal-title":"Neurosci Lett"},{"key":"pone.0277917.ref008","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/1743-0003-11-72","article-title":"Visuomotor behaviours when using a myoelectric prosthesis","volume":"11","author":"MM Sobuh","year":"2014","journal-title":"J Neuroeng Rehabil"},{"issue":"4","key":"pone.0277917.ref009","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1109\/TNSRE.2014.2305111","article-title":"The extraction of neural information from the surface EMG for the control of upper-limb prostheses: emerging avenues and challenges","volume":"22","author":"D Farina","year":"2014","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"8","key":"pone.0277917.ref010","doi-asserted-by":"crossref","first-page":"e0160817","DOI":"10.1371\/journal.pone.0160817","article-title":"Learning an EMG Controlled Game: Task-Specific Adaptations and Transfer","volume":"11","author":"L van Dijk","year":"2016","journal-title":"PLoS One"},{"issue":"12","key":"pone.0277917.ref011","doi-asserted-by":"crossref","first-page":"1384","DOI":"10.1109\/TNSRE.2015.2502424","article-title":"Task-Oriented Gaming for Transfer to Prosthesis Use","volume":"24","author":"L van Dijk","year":"2016","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"pone.0277917.ref012","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1109\/TRO.2007.910708","article-title":"On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User\u2013Prosthesis Interaction","volume":"24","author":"C Cipriani","year":"2008","journal-title":"IEEE Transactions on Robotics"},{"key":"pone.0277917.ref013","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1186\/1743-0003-11-132","article-title":"Comparison of range-of-motion and variability in upper body movements between transradial prosthesis users and able-bodied controls when executing goal-oriented tasks","volume":"11","author":"MJ Major","year":"2014","journal-title":"J Neuroeng Rehabil"},{"issue":"6","key":"pone.0277917.ref014","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1177\/0309364619871185","article-title":"Biomechanical analysis of users of multi-articulating externally powered prostheses with and without their device","volume":"43","author":"AB Wanamaker","year":"2019","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"pone.0277917.ref015","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1682\/JRRD.2014.08.0192","article-title":"Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review","volume":"52","author":"SL Carey","year":"2015","journal-title":"J Rehabil Res Dev"},{"issue":"7","key":"pone.0277917.ref016","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1097\/01.phm.0000166885.16180.63","article-title":"Factor structure of the Trinity Amputation and Prosthesis Experience Scales (TAPES) with individuals with acquired upper limb amputations","volume":"84","author":"DM Desmond","year":"2005","journal-title":"Am J Phys Med Rehabil"},{"issue":"6","key":"pone.0277917.ref017","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1053\/apmr.2002.32737","article-title":"Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity","volume":"83","author":"CM Light","year":"2002","journal-title":"Arch Phys Med Rehabil"},{"issue":"4","key":"pone.0277917.ref018","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s12178-020-09656-6","article-title":"Technological Advances in Prosthesis Design and Rehabilitation Following Upper Extremity Limb Loss","volume":"13","author":"TJ Bates","year":"2020","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"9","key":"pone.0277917.ref019","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.clinbiomech.2008.05.008","article-title":"Compensatory movements of transradial prosthesis users during common tasks","volume":"23","author":"SL Carey","year":"2008","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"8","key":"pone.0277917.ref020","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1682\/JRRD.2011.10.0207","article-title":"Case report of modified Box and Blocks test with motion capture to measure prosthetic function","volume":"49","author":"JS Hebert","year":"2012","journal-title":"J Rehabil Res Dev"},{"issue":"11","key":"pone.0277917.ref021","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1016\/j.apmr.2008.05.016","article-title":"Control of a six degree of freedom prosthetic arm after targeted muscle reinnervation surgery","volume":"89","author":"LA Miller","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"key":"pone.0277917.ref022","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.clinbiomech.2019.12.002","article-title":"Compensatory strategies of body-powered prosthesis users reveal primary reliance on trunk motion and relation to skill level","volume":"72","author":"AM Valevicius","year":"2020","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"1","key":"pone.0277917.ref023","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1080\/03093640208726621","article-title":"Gait analysis in prosthetics: opinions, ideas and conclusions","volume":"26","author":"JS Rietman","year":"2002","journal-title":"Prosthet Orthot Int"},{"issue":"4","key":"pone.0277917.ref024","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1682\/JRRD.2003.06.0102","article-title":"A systematic literature review of the effect of different prosthetic components on human functioning with a lower-limb prosthesis","volume":"41","author":"H van der Linde","year":"2004","journal-title":"J Rehabil Res Dev"},{"key":"pone.0277917.ref025","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1743-0003-11-16","article-title":"Changes in performance over time while learning to use a myoelectric prosthesis","volume":"11","author":"H Bouwsema","year":"2014","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"pone.0277917.ref026","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1177\/0309364614554030","article-title":"Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test","volume":"40","author":"L Haverkate","year":"2016","journal-title":"Prosthet Orthot Int"},{"issue":"10","key":"pone.0277917.ref027","doi-asserted-by":"crossref","first-page":"1874","DOI":"10.1109\/TNSRE.2017.2693234","article-title":"An Integrated Movement Analysis Framework to Study Upper Limb Function: A Pilot Study","volume":"25","author":"K Kontson","year":"2017","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"4","key":"pone.0277917.ref028","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TNSRE.2015.2398112","article-title":"Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?","volume":"23","author":"F Montagnani","year":"2015","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"pone.0277917.ref029","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1177\/0309364616660248","article-title":"Categorization of compensatory motions in transradial myoelectric prosthesis users","volume":"41","author":"A Hussaini","year":"2017","journal-title":"Prosthet Orthot Int"},{"key":"pone.0277917.ref030","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1186\/s12984-016-0130-0","article-title":"Flexible and static wrist units in upper limb prosthesis users: functionality scores, user satisfaction and compensatory movements","volume":"13","author":"M Deijs","year":"2016","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"pone.0277917.ref031","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1109\/TMRB.2020.3048251","article-title":"Closing the Loop Between Body Compensations and Upper Limb Prosthetic Movements: A Feasibility Study","volume":"3","author":"M Legrand","year":"2021","journal-title":"IEEE Transactions on Medical Robotics and Bionics"},{"key":"pone.0277917.ref032","doi-asserted-by":"crossref","DOI":"10.3389\/fnbot.2018.00001","article-title":"Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?","volume":"12","author":"M Merad","year":"2018","journal-title":"Front Neurorobotics"},{"issue":"1","key":"pone.0277917.ref033","doi-asserted-by":"crossref","first-page":"4999","DOI":"10.1038\/s41598-017-05094-6","article-title":"Reachability and the sense of embodiment in amputees using prostheses","volume":"7","author":"A Gouzien","year":"2017","journal-title":"Sci Rep"},{"issue":"3","key":"pone.0277917.ref034","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1080\/03093640308726682","article-title":"Development and measurement properties of the Orthotics and Prosthetics Users\u2019 Survey (OPUS): a comprehensive set of clinical outcome instruments","volume":"27","author":"AW Heinemann","year":"2003","journal-title":"Prosthet Orthot Int"},{"issue":"7\u20138","key":"pone.0277917.ref035","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1016\/S0893-6080(98)00047-1","article-title":"Modeling parietal-premotor interactions in primate control of grasping","volume":"11","author":"AH Fagg","year":"1998","journal-title":"Neural Netw"},{"issue":"5","key":"pone.0277917.ref036","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/j.jbiomech.2004.05.042","article-title":"ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion\u2014Part II: shoulder, elbow, wrist and hand","volume":"38","author":"G Wu","year":"2005","journal-title":"J Biomech"},{"issue":"Pt 2","key":"pone.0277917.ref037","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1093\/brain\/105.2.331","article-title":"Human arm trajectory formation","volume":"105","author":"W Abend","year":"1982","journal-title":"Brain"},{"issue":"7","key":"pone.0277917.ref038","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.1523\/JNEUROSCI.05-07-01688.1985","article-title":"The coordination of arm movements: an experimentally confirmed mathematical model","volume":"5","author":"T Flash","year":"1985","journal-title":"J Neurosci"},{"issue":"3","key":"pone.0277917.ref039","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1080\/00222895.1984.10735319","article-title":"The timing of natural prehension movements","volume":"16","author":"M. Jeannerod","year":"1984","journal-title":"J Mot Behav"},{"key":"pone.0277917.ref040","volume-title":"The neural and behavioral organization of goal-directed movements","author":"M. Jeannerod","year":"1988"},{"key":"pone.0277917.ref041","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1017\/CBO9780511581267.011","volume-title":"Sensorimotor Control of Grasping, Physiology and Pathophysiology","author":"M. Jeannerod","year":"2009"},{"issue":"3","key":"pone.0277917.ref042","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1152\/jn.1998.79.3.1307","article-title":"Gradual molding of the hand to object contours","volume":"79","author":"M Santello","year":"1998","journal-title":"J Neurophysiol"},{"issue":"3","key":"pone.0277917.ref043","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1007\/BF00233990","article-title":"The speed-accuracy trade-off in manual prehension: effects of movement amplitude, object size and object width on kinematic characteristics","volume":"98","author":"RJ Bootsma","year":"1994","journal-title":"Exp Brain Res"},{"key":"pone.0277917.ref044","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/0167-9457(90)90025-9","article-title":"Functional relationship between grasp and transport components in a prehension task","volume":"9","author":"RG Marteniuk","year":"1990","journal-title":"Human Movement Science"},{"key":"pone.0277917.ref045","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1007\/BF00231858","article-title":"Selective perturbation of visual input during prehension movements. 2. The effects of changing object size","volume":"87","author":"Y Paulignan","year":"1991","journal-title":"Experimental Brain Research"},{"key":"pone.0277917.ref046","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1007\/BF00229827","article-title":"Selective perturbation of visual input during prehension movements 1. The effects of changing object position","volume":"83","author":"Y Paulignan","year":"1991","journal-title":"Experimental Brain Research"},{"issue":"4","key":"pone.0277917.ref047","first-page":"427","article-title":"Coordination in prehension. Information-based coupling of reaching and grasping","volume":"119","author":"FT Zaal","year":"1998","journal-title":"Exp Brain Res"},{"issue":"3","key":"pone.0277917.ref048","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1682\/JRRD.2009.06.0075","article-title":"Feedforward control strategies of subjects with transradial amputation in planar reaching","volume":"47","author":"AJ Metzger","year":"2010","journal-title":"J Rehabil Res Dev"},{"issue":"6","key":"pone.0277917.ref049","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.clinbiomech.2010.02.011","article-title":"Movement characteristics of upper extremity prostheses during basic goal-directed tasks","volume":"25","author":"H Bouwsema","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"pone.0277917.ref050","article-title":"Differences in quality of movements made with body-powered and myoelectric prostheses during activities of daily living","author":"SM Engdahl","year":"2021","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"pone.0277917.ref051","first-page":"259","volume-title":"Analyse instrumentale de la pr\u00e9hension proth\u00e9tique","author":"N Martinet","year":"2000"},{"issue":"3","key":"pone.0277917.ref052","doi-asserted-by":"crossref","first-page":"151","DOI":"10.3109\/03093648109146239","article-title":"A case study of reaching by a user of a manually-operated artificial hand","volume":"5","author":"C Fraser","year":"1981","journal-title":"Prosthet Orthot Int"},{"key":"pone.0277917.ref053","doi-asserted-by":"crossref","unstructured":"Wing A. Coordination in normal and prosthetic reaching. In: S.T. V, Iberall T, editors. Dextrous robot hands: Springer Verlag; 1990.","DOI":"10.1007\/978-1-4613-8974-3_3"},{"key":"pone.0277917.ref054","volume-title":"Sensorimotor Control of grasping, physiology and pathophysiology","author":"R Johansson","year":"2009"},{"issue":"5","key":"pone.0277917.ref055","doi-asserted-by":"crossref","first-page":"e0177965","DOI":"10.1371\/journal.pone.0177965","article-title":"Targeted box and blocks test: Normative data and comparison to standard tests","volume":"12","author":"K Kontson","year":"2017","journal-title":"PLoS One"},{"issue":"1","key":"pone.0277917.ref056","doi-asserted-by":"crossref","first-page":"e0226563","DOI":"10.1371\/journal.pone.0226563","article-title":"Kinematic analysis of motor learning in upper limb body-powered bypass prosthesis training","volume":"15","author":"C Bloomer","year":"2020","journal-title":"PLoS One"},{"issue":"1","key":"pone.0277917.ref057","doi-asserted-by":"crossref","first-page":"15471","DOI":"10.1038\/s41598-020-72470-0","article-title":"Differential experiences of embodiment between body-powered and myoelectric prosthesis users","volume":"10","author":"SM Engdahl","year":"2020","journal-title":"Sci Rep"},{"key":"pone.0277917.ref058","volume-title":"The co-ordination and regulation of movements","author":"N. Bernstein","year":"1967"},{"key":"pone.0277917.ref059","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1152\/jn.1997.77.1.452","article-title":"Postural control of three-dimensional prehension movements","volume":"77","author":"M Desmurget","year":"1997","journal-title":"Journal of Neurophysiology"},{"issue":"5","key":"pone.0277917.ref060","first-page":"1365","article-title":"Postural dynamics and the preferred critical boundary for visually guided reaching","volume":"23","author":"LS Mark","year":"1997","journal-title":"Journal of Experimental Psychology"},{"issue":"2","key":"pone.0277917.ref061","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1080\/03093640802613229","article-title":"Kinematic comparison of myoelectric and body powered prostheses while performing common activities","volume":"33","author":"SL Carey","year":"2009","journal-title":"Prosthet Orthot Int"},{"issue":"11","key":"pone.0277917.ref062","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1016\/j.apmr.2012.03.011","article-title":"Characterization of compensatory trunk movements during prosthetic upper limb reaching tasks","volume":"93","author":"AJ Metzger","year":"2012","journal-title":"Arch Phys Med Rehabil"},{"issue":"3","key":"pone.0277917.ref063","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jht.2017.12.003","article-title":"Development and reliability of the rating of compensatory movements in upper limb prosthesis wearers during work-related tasks","volume":"32","author":"TMJ van der Laan","year":"2019","journal-title":"J Hand Ther"},{"key":"pone.0277917.ref064","doi-asserted-by":"crossref","first-page":"109843","DOI":"10.1016\/j.jbiomech.2020.109843","article-title":"Computational musculoskeletal modeling of compensatory movements in the upper limb","volume":"108","author":"M Reilly","year":"2020","journal-title":"J Biomech"},{"issue":"4","key":"pone.0277917.ref065","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1177\/0309364615584658","article-title":"A survey of overuse problems in patients with acquired or congenital upper limb deficiency","volume":"40","author":"H Burger","year":"2016","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"pone.0277917.ref066","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/JPO.0b013e31817ecb16","article-title":"Overuse Syndrome and the Unilateral Upper Limb Amputee: Consequences and Prevention","volume":"20","author":"C. Gambrell","year":"2008","journal-title":"Journal of Prosthetics and Orthotics"},{"issue":"12","key":"pone.0277917.ref067","doi-asserted-by":"crossref","first-page":"1967","DOI":"10.1016\/j.apmr.2011.06.026","article-title":"Musculoskeletal pain and overuse syndromes in adult acquired major upper-limb amputees","volume":"92","author":"K Ostlie","year":"2011","journal-title":"Arch Phys Med Rehabil"},{"issue":"11","key":"pone.0277917.ref068","doi-asserted-by":"crossref","first-page":"e49727","DOI":"10.1371\/journal.pone.0049727","article-title":"Body structures and physical complaints in upper limb reduction deficiency: a 24-year follow-up study","volume":"7","author":"SG Postema","year":"2012","journal-title":"PLoS One"},{"issue":"7","key":"pone.0277917.ref069","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1016\/j.apmr.2016.01.031","article-title":"Musculoskeletal Complaints in Transverse Upper Limb Reduction Deficiency and Amputation in The Netherlands: Prevalence, Predictors, and Effect on Health","volume":"97","author":"SG Postema","year":"2016","journal-title":"Arch Phys Med Rehabil"},{"issue":"4\u20135","key":"pone.0277917.ref070","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/S0268-0033(98)00096-5","article-title":"A biomechanical study of occupational loads in the shoulder and elbow in dentistry","volume":"13","author":"L Finsen","year":"1998","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"4","key":"pone.0277917.ref071","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1539\/joh.11-0262-OA","article-title":"Effects of individual and work-related factors on incidence of shoulder pain in a large working population","volume":"54","author":"J Bodin","year":"2012","journal-title":"J Occup Health"},{"key":"pone.0277917.ref072","unstructured":"Hansson G, Arvidsson I, Nordander C. Riktv\u00e4rden f\u00f6r att bed\u00f6ma risken f\u00f6r belastningsskador, baserade p\u00e5 tekniska m\u00e4tningar av exponeringen. Lund, Sweden; 2016. Contract No.: Report n\u00b04."},{"issue":"1\u20132","key":"pone.0277917.ref073","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0006-8993(00)02378-7","article-title":"Hand orientation for grasping depends on the direction of the reaching movement","volume":"869","author":"A Roby-Brami","year":"2000","journal-title":"Brain Res"},{"issue":"3","key":"pone.0277917.ref074","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1109\/TOH.2014.2326871","article-title":"Analysis of human grasping behavior: object characteristics and grasp type","volume":"7","author":"T Feix","year":"2014","journal-title":"IEEE Trans Haptics"},{"key":"pone.0277917.ref075","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1093\/brain\/123.5.940","article-title":"Compensatory strategies for reaching in stroke","volume":"123","author":"MC Cirstea","year":"2000","journal-title":"Brain"},{"issue":"2","key":"pone.0277917.ref076","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/s00221-001-0976-6","article-title":"Use of the trunk for reaching targets placed within and beyond the reach in adult hemiparesis","volume":"143","author":"MF Levin","year":"2002","journal-title":"Exp Brain Res"},{"key":"pone.0277917.ref077","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1123\/mcj.1.1.72","article-title":"Reaching and grasping strategies in hemiparetic patients","volume":"1","author":"A Roby-Brami","year":"1997","journal-title":"Motor Control"},{"issue":"5","key":"pone.0277917.ref078","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1034\/j.1600-0404.2003.00021.x","article-title":"Motor compensation and recovery for reaching in stroke patients","volume":"107","author":"A Roby-Brami","year":"2003","journal-title":"Acta Neurol Scand"},{"issue":"1","key":"pone.0277917.ref079","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1080\/00140130120716","article-title":"Theories of musculoskeletal injury causation","volume":"44","author":"S. Kumar","year":"2001","journal-title":"Ergonomics"},{"issue":"1","key":"pone.0277917.ref080","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1109\/TMRB.2020.2970065","article-title":"Assessment of an Automatic Prosthetic Elbow Control Strategy Using Residual Limb Motion for Transhumeral Amputated Individuals With Socket or Osseointegrated Prostheses","volume":"2","author":"M Merad","year":"2020","journal-title":"IEEE Transactions on Medical Robotics and Bionics"},{"issue":"2","key":"pone.0277917.ref081","doi-asserted-by":"crossref","first-page":"1973","DOI":"10.1109\/LRA.2021.3061351","article-title":"Exploiting inherent human motor behaviour in the online personalisation of human-prosthetic interfaces","volume":"6","author":"R Garcia-Rosas","year":"2021","journal-title":"IEEE Robotics and Automation Letters"},{"key":"pone.0277917.ref082","first-page":"jrm00245","article-title":"Effect of multi-grip myoelectric prosthetic hands on daily activities, pain-related disability and prosthesis use compared with single-grip myoelectric prostheses: A single-case study","volume":"54","author":"C Widehammar","year":"2022","journal-title":"J Rehabil Med"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0277917","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,18]],"date-time":"2022-11-18T13:25:09Z","timestamp":1668777909000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0277917"}},"subtitle":[],"editor":[{"given":"Thomas A","family":"Stoffregen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,11,18]]},"references-count":82,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11,18]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0277917","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,18]]}}}