{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T14:55:10Z","timestamp":1781880910306,"version":"3.54.5"},"reference-count":19,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T00:00:00Z","timestamp":1682035200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Myopic Choroidal neovascularization (mCNV) is one of the most common vision-threatening com- plications of pathological myopia among many retinal diseases. Optical Coherence Tomography Angiography (OCTA) is an emerging newer non-invasive imaging technique and is recently being included in the investigation and treatment of mCNV. However, there exists no standard tool for time-efficient and dependable analysis of OCTA images of mCNV. In this study, we propose a customizable ImageJ macro that automates the OCTA image processing and lets users measure nine mCNV biomarkers. We developed a three-stage image processing pipeline to process the OCTA images using the macro. The images were first manually delineated, and then denoised using a Gaussian Filter. This was followed by the application of the Frangi filter and Local Adaptive thresholding. Finally, skeletonized images were obtained using the Mexican Hat filter. Nine vascular biomarkers including Junction Density, Vessel Diameter, and Fractal Dimension were then computed from the skeletonized images. The macro was tested on a 26 OCTA image dataset for all biomarkers. Two trends emerged in the computed biomarker values. First, the lesion-size dependent parameters (mCNV Area (mm<jats:sup>2<\/jats:sup>) Mean = 0.65, SD = 0.46) showed high variation, whereas normalized parameters (Junction Density(n\/mm): Mean = 10.24, SD = 0.63) were uniform throughout the dataset. The computed values were consistent with manual measurements within existing literature. The results illustrate our ImageJ macro to be a convenient alternative for manual OCTA image processing, including provisions for batch processing and parameter customization, providing a systematic, reliable analysis of mCNV.<\/jats:p>","DOI":"10.1371\/journal.pone.0283929","type":"journal-article","created":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T17:51:58Z","timestamp":1682099518000},"page":"e0283929","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":14,"title":["An ImageJ macro tool for OCTA-based quantitative analysis of Myopic Choroidal neovascularization"],"prefix":"10.1371","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9897-6372","authenticated-orcid":true,"given":"Aadit","family":"Deshpande","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4975-4121","authenticated-orcid":true,"given":"Sundaresan","family":"Raman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber","family":"Dubey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradeep","family":"Susvar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajiv","family":"Raman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2023,4,21]]},"reference":[{"key":"pone.0283929.ref001","first-page":"586","article-title":"Optical Coherence Tomography Angiography- Based Quantitative Assessment of Morphologic Changes in Active Myopic Choroidal Neovas- cularization During Anti-vascular Endothelial Growth Factor Therapy.","volume":"8","author":"Y Wang","year":"2021","journal-title":"Frontiers in Medicine."},{"issue":"1","key":"pone.0283929.ref002","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.ajo.2013.08.010","article-title":"Epidemiology and disease burden of pathologic myopia and myopic choroidal neovascularization: an evidence-based systematic review","volume":"157","author":"TY Wong","year":"2014","journal-title":"American journal of ophthalmology"},{"issue":"7","key":"pone.0283929.ref003","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1038\/s41433-019-0378-2","article-title":"Diagnostic algorithm utilising multimodal imaging including optical coherence tomography angiography for the detection of myopic choroidal neovascularisation.","volume":"33","author":"A Bagchi","year":"2019","journal-title":"Eye."},{"issue":"4","key":"pone.0283929.ref004","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1097\/IAE.0000000000002005","article-title":"Application of optical coherence tomography angiography to assess anti\u2013vascular endothelial growth factor therapy in myopic choroidal neovascularization.","volume":"39","author":"Y Cheng","year":"2019","journal-title":"Retina."},{"issue":"9","key":"pone.0283929.ref005","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1097\/IAE.0000000000002650","article-title":"Assessing the activity of myopic choroidal neovascularization: comparison between optical coherence tomography angiography and dye angiography.","volume":"40","author":"S Li","year":"2020","journal-title":"Retina (Philadelphia, Pa)."},{"issue":"7","key":"pone.0283929.ref006","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1038\/nmeth.2019","article-title":"Fiji: an open-source platform for biological-image analysis","volume":"9","author":"J Schindelin","year":"2012","journal-title":"Nature methods"},{"issue":"4","key":"pone.0283929.ref007","doi-asserted-by":"crossref","first-page":"e95576","DOI":"10.1371\/journal.pone.0095576","article-title":"Image registration algorithm using Mexican hat function-based operator and grouped feature matching strategy.","volume":"9","author":"F Jin","year":"2014","journal-title":"PloS one"},{"key":"pone.0283929.ref008","volume-title":"Feature extraction and image processing for computer vision.","author":"M Nixon","year":"2019"},{"issue":"1","key":"pone.0283929.ref009","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-020-62607-6","article-title":"Usefulness of Denois- ing process to Depict Myopic choroidal neovascularisation Using a Single optical coherence tomography Angiography image.","volume":"10","author":"Y Sawai","year":"2020","journal-title":"Scientific reports."},{"key":"pone.0283929.ref010","unstructured":"Curtis Rueden ML. Frangi Vesselness Filter-ImageJ [Internet]; Available from: https:\/\/imagej.net\/plugins\/frangi."},{"key":"pone.0283929.ref011","first-page":"130","volume-title":"In: International conference on medical image computing and computer-assisted intervention","author":"AF Frangi","year":"1998"},{"key":"pone.0283929.ref012","unstructured":"Landini G. Auto Local Threshold-ImageJ [Internet]; Available from: https:\/\/imagej.net\/plugins\/auto-local-threshold."},{"key":"pone.0283929.ref013","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.aasri.2012.11.074","article-title":"An improved median-based Otsu image thresholding algorithm.","volume":"3","author":"X Yang","year":"2012","journal-title":"Aasri Procedia"},{"key":"pone.0283929.ref014","unstructured":"Prodanov D. Mexican Hat Filter-ImageJ [Internet]; Available from: https:\/\/imagej.nih.gov\/ij\/plugins\/mexican-hat\/index.html."},{"issue":"6","key":"pone.0283929.ref015","first-page":"462","article-title":"Building skeleton models via 3-D medial surface axis thinning algorithms","volume":"56","author":"TC Lee","year":"1994","journal-title":"CVGIP: Graphical Models and Image Processing"},{"key":"pone.0283929.ref016","unstructured":"Arganda-Carreras I.AnalyzeSkeleton-ImageJ [Internet]; Available from: https:\/\/imagej.net\/plugins\/analyze-skeleton\/."},{"issue":"3","key":"pone.0283929.ref017","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1136\/bjophthalmol-2020-316111","article-title":"Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope","volume":"105","author":"X Yao","year":"2021","journal-title":"British Journal of Ophthalmology"},{"issue":"8","key":"pone.0283929.ref018","doi-asserted-by":"crossref","first-page":"3796","DOI":"10.1364\/BOE.8.003796","article-title":"Method for quantitative assessment of retinal vessel tortuosity in optical coherence tomography angiography applied to sickle cell retinopathy","volume":"8","author":"M. M. Khansari","year":"2017","journal-title":"Biomedical Optics Express"},{"issue":"8","key":"pone.0283929.ref019","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.18240\/ijo.2021.08.11","article-title":"Macular density alterations in myopic choroidal neovascularization and the effect of anti-VEGF on it","volume":"14","author":"JB Mao","year":"2021","journal-title":"International Journal of Ophthalmology"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0283929","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T17:52:18Z","timestamp":1682099538000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0283929"}},"subtitle":[],"editor":[{"given":"Ali Mohammad","family":"Alqudah","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2023,4,21]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,4,21]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0283929","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,21]]}}}