{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T23:15:48Z","timestamp":1784243748995,"version":"3.55.0"},"reference-count":32,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2023,4,6]],"date-time":"2023-04-06T00:00:00Z","timestamp":1680739200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Purpose<\/jats:title>\n<jats:p>Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Materials and methods<\/jats:title>\n<jats:p>Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Results<\/jats:title>\n<jats:p>The shoulder\u2019s mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG (<jats:italic>p<\/jats:italic> = .016 and <jats:italic>p<\/jats:italic> = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG (<jats:italic>p<\/jats:italic> = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG (<jats:italic>p<\/jats:italic> = .002 and <jats:italic>p<\/jats:italic>&lt; .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG (<jats:italic>p<\/jats:italic> = .014 and <jats:italic>p<\/jats:italic> = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec004\">\n<jats:title>Conclusion<\/jats:title>\n<jats:p>The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0284178","type":"journal-article","created":{"date-parts":[[2023,4,6]],"date-time":"2023-04-06T17:50:18Z","timestamp":1680803418000},"page":"e0284178","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":4,"title":["Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life"],"prefix":"10.1371","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4132-8531","authenticated-orcid":true,"given":"Cansu","family":"Cosgun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muharrem Said","family":"Cosgun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oznur","family":"Buyukturan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Buket","family":"Buyukturan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2023,4,6]]},"reference":[{"issue":"6","key":"pone.0284178.ref001","first-page":"460","article-title":"CIED implantation in elderly patients: a single-center experience","volume":"15","author":"NN Ilov","year":"2018","journal-title":"J Geriatr Cardiol"},{"issue":"1","key":"pone.0284178.ref002","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1161\/01.CIR.0000048892.83521.58","article-title":"Arterial and cardiac aging: major shareholders in cardiovascular disease enterprises: Part I: aging arteries: a \"set up\" for vascular disease.","volume":"107","author":"EG Lakatta","year":"2003","journal-title":"Circulation"},{"issue":"6","key":"pone.0284178.ref003","first-page":"101","article-title":"Trends in aging\u2014United States and worldwide.","volume":"52","author":"Centers for Disease Control and Prevention (CDC)","year":"2003","journal-title":"MMWR Morb Mortal Wkly Rep"},{"issue":"2","key":"pone.0284178.ref004","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1080\/17434440.2021.1866543","article-title":"Pacing devices to treat bradycardia: current status and future perspectives.","volume":"18","author":"M Biffi","year":"2021","journal-title":"Expert Rev Med Devices."},{"issue":"10","key":"pone.0284178.ref005","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.amjcard.2014.02.025","article-title":"Determinants of all-cause mortality in different age groups in patients with severe systolic left ventricular dysfunction receiving an implantable cardioverter defibrillator (from the Italian ClinicalService Multicenter Observational Project)","volume":"113","author":"S Fumagalli","year":"2014","journal-title":"Am J CardiolMay 15"},{"issue":"2","key":"pone.0284178.ref006","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1002\/ehf2.13192","article-title":"Real-world outcomes in cardiac resynchronization therapy patients: design and baseline demographics of the SMART- Registry","volume":"8","author":"D Gardner RS","year":"2021","journal-title":"ESC Heart Fail"},{"issue":"4","key":"pone.0284178.ref007","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/S0025-6196(12)62213-7","article-title":"Consistent subcutaneous prepectoral implantation of a new implantable cardioverter defibrillator","volume":"69","author":"MS Stanton","year":"1994","journal-title":"Mayo Clin Proc"},{"issue":"18","key":"pone.0284178.ref008","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1093\/eurheartj\/eht511","article-title":"Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark","volume":"35","author":"RE Kirkfeldt","year":"2014","journal-title":"Eur Heart J"},{"issue":"2","key":"pone.0284178.ref009","first-page":"163","article-title":"Avoiding implant complications in cardiac implantable electronic devices: what works? Europace","volume":"23","author":"M Frausing","year":"2021"},{"issue":"12","key":"pone.0284178.ref010","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.1016\/j.hrthm.2021.09.008","article-title":"Time to diagnosis of acute complications after cardiovascular implantable electronic device insertion and optimal timing of discharge within the first 24 hours","volume":"18","year":"2021","journal-title":"Heart Rhythm"},{"issue":"1","key":"pone.0284178.ref011","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.ijcard.2012.09.071","article-title":"Implantation of cardioverter-defibrillator: effects on shoulder function","volume":"168","author":"I Diemberger","year":"2013","journal-title":"Int J Cardiol"},{"issue":"2","key":"pone.0284178.ref012","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.athoracsur.2019.10.063","article-title":"Shoulder Function After Cardioverter-Defibrillator Implantation: 5-Year Follow-up","volume":"110","author":"C Martignani","year":"2020","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"pone.0284178.ref013","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1111\/pace.14465","article-title":"Efficacy and safety of different exercises in preventing cardiac implantable electronic device-related shoulder impairment","volume":"45","author":"MS Cosgun","year":"2022","journal-title":"Pacing Clin Electrophysiol"},{"issue":"9","key":"pone.0284178.ref014","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1111\/pace.13999","article-title":"Prevention of adhesive capsulitis following pacemaker implantation: A randomized controlled study","volume":"43","author":"MV Jorat","year":"2020","journal-title":"Pacing Clin Electrophysiol"},{"issue":"3","key":"pone.0284178.ref015","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s10840-019-00541-y","article-title":"Effect of early pendulum exercise on shoulder function after cardiac rhythm management device implantation","volume":"55","author":"W Wongcharoen","year":"2019","journal-title":"J Interv Card Electrophysiol"},{"issue":"6","key":"pone.0284178.ref016","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1111\/j.1540-8159.2010.03026.x","article-title":"Preventing shoulder pain after cardiac rhythm management device implantation: a randomized, controlled study","volume":"34","author":"JD Daniels","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"issue":"18","key":"pone.0284178.ref017","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.1161\/01.CIR.0000016183.07898.90","article-title":"Cardiology patient pages. Cardiac pacemakers from the patient\u2019s perspective","volume":"105","author":"MA Wood","year":"2002","journal-title":"Circulation"},{"issue":"1","key":"pone.0284178.ref018","first-page":"46","article-title":"Patient education guide. Pacemakers","volume":"34","author":"P Toth","year":"2004","journal-title":"Nursing"},{"issue":"4","key":"pone.0284178.ref019","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/MRR.0000000000000122","article-title":"Limitation of motion and shoulder disabilities in patients with cardiac implantable electronic devices.","volume":"38","author":"G Findikoglu","year":"2015","journal-title":"Int J Rehabil Res."},{"issue":"4","key":"pone.0284178.ref020","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/S0002-8703(98)70270-4","article-title":"Prospective evaluation of shoulder-related problems in patients with pectoral cardioverter-defibrillator implantation","volume":"135","author":"T Korte","year":"1998","journal-title":"Am Heart J"},{"issue":"3","key":"pone.0284178.ref021","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1023\/A:1009803927436","article-title":"Frozen shoulder syndrome associated with subpectoral defibrillator implantation.","volume":"3","author":"MC Burke","year":"1999","journal-title":"J Interv Card Electrophysiol"},{"issue":"5","key":"pone.0284178.ref022","first-page":"590","article-title":"Biomechanics of the shoulder.","volume":"31","author":"VP Kumar","year":"2002","journal-title":"Ann Acad Med SingapSep"},{"issue":"5","key":"pone.0284178.ref023","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1136\/bjsm.2009.058834","article-title":"Current concepts: scapular dyskinesis.","volume":"44","author":"WB Kibler","year":"2010","journal-title":"Br J Sports MedApr"},{"issue":"2","key":"pone.0284178.ref024","doi-asserted-by":"crossref","first-page":"160","DOI":"10.4085\/1062-6050-44.2.160","article-title":"A clinical method for identifying scapular dyskinesis, part 1: reliability.","volume":"44","author":"P McClure","year":"2009","journal-title":"Journal of athletic training"},{"issue":"2","key":"pone.0284178.ref025","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1093\/ptj\/81.2.799","article-title":"Measurement of scapular asymetry and assessment of shoulder dysfunction using the Lateral Scapular Slide Test: a reliability and validity study.","volume":"81","author":"CJ Odom","year":"2001","journal-title":"Physical therapy."},{"issue":"5","key":"pone.0284178.ref026","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1136\/bjsm.2009.058834","article-title":"Current concepts: scapular dyskinesis.","volume":"44","author":"WB Kibler","year":"2010","journal-title":"British journal of sports medicine"},{"issue":"12","key":"pone.0284178.ref027","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1111\/pace.14378","article-title":"Predictors of shoulder limitations and disability in patients with cardiac implantable electronic devices: Importance of device size","volume":"44","author":"MS Cosgun","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"issue":"6","key":"pone.0284178.ref028","doi-asserted-by":"crossref","first-page":"937","DOI":"10.3233\/BMR-181362","article-title":"A comparison of physical characteristics, functions and quality of life between breast cancer survivor women who had a mastectomy and healthy women","volume":"32","author":"F Zabit","year":"2019","journal-title":"J Back Musculoskelet Rehabil"},{"issue":"3","key":"pone.0284178.ref029","doi-asserted-by":"crossref","first-page":"e285","DOI":"10.1016\/j.clbc.2020.10.008","article-title":"Comparison of Shoulder-Arm Complex Pain, Function, and Scapular Dyskinesia in Women With and Without Unilateral Lymphedema After Breast Cancer Surgery.","volume":"21","author":"TS Korucu","year":"2021","journal-title":"Clin Breast Cancer"},{"issue":"6","key":"pone.0284178.ref030","doi-asserted-by":"crossref","first-page":"364","DOI":"10.5435\/JAAOS-20-06-364","article-title":"Scapular dyskinesis and its relation to shoulder injury.","volume":"20","author":"WB Kibler","year":"2012","journal-title":"J Am Acad Orthop Surg."},{"issue":"3","key":"pone.0284178.ref031","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.injury.2010.11.046","article-title":"Measuring shoulder injury function: common scales and checklists.","volume":"42","author":"GP Slobogean","year":"2011","journal-title":"Injury"},{"issue":"4","key":"pone.0284178.ref032","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.jse.2020.07.015","article-title":"The American Shoulder and Elbow Surgeons score highly correlates with the Simple Shoulder Test.","volume":"30","author":"KM Baumgarten","year":"2021","journal-title":"J Shoulder Elbow Surg."}],"updated-by":[{"DOI":"10.1371\/journal.pone.0348025","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000}}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0284178","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,6]],"date-time":"2023-04-06T17:50:43Z","timestamp":1680803443000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0284178"}},"subtitle":[],"editor":[{"given":"Ey\u00fcp Serhat","family":"\u00c7al\u0131k","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2023,4,6]]},"references-count":32,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,4,6]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0284178","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,6]]}}}