{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T20:10:25Z","timestamp":1767903025846,"version":"3.49.0"},"reference-count":70,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13FH628IX6"],"award-info":[{"award-number":["13FH628IX6"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100010665","name":"H2020 Marie Sk\u0142odowska-Curie Actions","doi-asserted-by":"publisher","award":["Rise (#872488 DCPM)"],"award-info":[{"award-number":["Rise (#872488 DCPM)"]}],"id":[{"id":"10.13039\/100010665","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Structural prior information can improve electrical impedance tomography (EIT) reconstruction. In this contribution, we introduce a discrete cosine transformation-based (DCT-based) EIT reconstruction algorithm to demonstrate a way to incorporate the structural prior with the EIT reconstruction process. Structural prior information is obtained from other available imaging methods, e.g., thorax-CT. The DCT-based approach creates a functional EIT image of regional lung ventilation while preserving the introduced structural information. This leads to an easier interpretation in clinical settings while maintaining the advantages of EIT in terms of bedside monitoring during mechanical ventilation. Structural priors introduced in the DCT-based approach are of two categories in terms of different levels of information included: a contour prior only differentiates lung and non-lung region, while a detail prior includes information, such as atelectasis, within the lung area. To demonstrate the increased interpretability of the EIT image through structural prior in the DCT-based approach, the DCT-based reconstructions were compared with reconstructions from a widely applied one-step Gauss-Newton solver with background prior and from the advanced GREIT algorithm. The comparisons were conducted both on simulation data and retrospective patient data. In the simulation, we used two sets of forward models to simulate different lung conditions. A contour prior and a detail prior were derived from simulation ground truth. With these two structural priors, the reconstructions from the DCT-based approach were compared with the reconstructions from both the one-step Gauss-Newton solver and the GREIT. The difference between the reconstructions and the simulation ground truth is calculated by the <jats:italic>\u2113<\/jats:italic><jats:sub>2<\/jats:sub>-norm image difference. In retrospective patient data analysis, datasets from six lung disease patients were included. For each patient, a detail prior was derived from the patient\u2019s CT, respectively. The detail prior was used for the reconstructions using the DCT-based approach, which was compared with the reconstructions from the GREIT. The reconstructions from the DCT-based approach are more comprehensive and interpretable in terms of preserving the structure specified by the priors, both in simulation and retrospective patient data analysis. In simulation analysis, the <jats:italic>\u2113<\/jats:italic><jats:sub>2<\/jats:sub>-norm image difference of the DCT-based approach with a contour prior decreased on average by 34% from GREIT and 49% from the Gauss-Newton solver with background prior; for reconstructions of the DCT-based approach with detail prior, on average the <jats:italic>\u2113<\/jats:italic><jats:sub>2<\/jats:sub>-norm image difference is 53% less than GREIT and 63% less than the reconstruction with background prior. In retrospective patient data analysis, the reconstructions from both the DCT-based approach and GREIT can indicate the current patient status, but the DCT-based approach yields more interpretable results. However, it is worth noting that the preserved structure in the DCT-based approach is derived from another imaging method, not from the EIT measurement. If the structural prior is outdated or wrong, the result might be misleadingly interpreted, which induces false clinical conclusions. Further research in terms of evaluating the validity of the structural prior and detecting the outdated prior is necessary.<\/jats:p>","DOI":"10.1371\/journal.pone.0285619","type":"journal-article","created":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T17:24:50Z","timestamp":1683825890000},"page":"e0285619","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":9,"title":["Structural priors represented by discrete cosine transform improve EIT functional imaging"],"prefix":"10.1371","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6233-129X","authenticated-orcid":true,"given":"Rongqing","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabine","family":"Krueger-Ziolek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e1s","family":"Lovas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bal\u00e1zs","family":"Beny\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan J.","family":"Rupitsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Knut","family":"Moeller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2023,5,11]]},"reference":[{"issue":"1","key":"pone.0285619.ref001","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1186\/s13054-018-2137-3","article-title":"Regional Expiratory Time Constants in Severe Respiratory Failure Estimated by Electrical Impedance Tomography: A Feasibility Study","volume":"22","author":"C Karagiannidis","year":"2018","journal-title":"Critical Care"},{"issue":"1","key":"pone.0285619.ref002","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","article-title":"Chest Electrical Impedance Tomography Examination, Data Analysis, Terminology, Clinical Use and Recommendations: Consensus Statement of the TRanslational EIT developmeNt stuDy Group","volume":"72","author":"I Frerichs","year":"2017","journal-title":"Thorax"},{"issue":"1","key":"pone.0285619.ref003","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13054-016-1475-2","article-title":"Electrical Impedance Tomography to Determine Optimal Positive End-Expiratory Pressure in Severe Chronic Obstructive Pulmonary Disease","volume":"20","author":"E Kostakou","year":"2016","journal-title":"Critical Care"},{"issue":"2","key":"pone.0285619.ref004","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.jcrc.2011.04.008","article-title":"High-Frequency Oscillatory Ventilation in Patients with Acute Exacerbation of Chronic Obstructive Pulmonary Disease","volume":"27","author":"I Frerichs","year":"2012","journal-title":"Journal of critical care"},{"issue":"12","key":"pone.0285619.ref005","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1007\/s00134-012-2684-z","article-title":"Electrical Impedance Tomography: The Holy Grail of Ventilation and Perfusion Monitoring?","volume":"38","author":"S Leonhardt","year":"2012","journal-title":"Intensive care medicine"},{"issue":"3","key":"pone.0285619.ref006","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1097\/CCM.0B013E3181652EDD","article-title":"Electrical Impedance Tomography Compared with Thoracic Computed Tomography during a Slow Inflation Maneuver in Experimental Models of Lung Injury","volume":"36","author":"H Wrigge","year":"2008","journal-title":"Critical care medicine"},{"issue":"10","key":"pone.0285619.ref007","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1088\/0967-3334\/34\/10\/1303","article-title":"Quantification of Ventilation Distribution in Regional Lung Injury by Electrical Impedance Tomography and Xenon Computed Tomography","volume":"34","author":"G Elke","year":"2013","journal-title":"Physiological measurement"},{"issue":"3","key":"pone.0285619.ref008","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1080\/0309190021000059687","article-title":"Electrical Impedance Tomography (EIT): A Review","volume":"27","author":"BH Brown","year":"2003","journal-title":"Journal of medical engineering & technology"},{"issue":"9","key":"pone.0285619.ref009","doi-asserted-by":"crossref","first-page":"1754","DOI":"10.1109\/TMI.2012.2200904","article-title":"Impact of Model Shape Mismatch on Reconstruction Quality in Electrical Impedance Tomography","volume":"31","author":"B Grychtol","year":"2012","journal-title":"IEEE transactions on medical imaging"},{"issue":"3","key":"pone.0285619.ref010","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/cc7900","article-title":"Electrical Impedance Tomography Compared to Positron Emission Tomography for the Measurement of Regional Lung Ventilation: An Experimental Study","volume":"13","author":"J Richard","year":"2009","journal-title":"Critical Care"},{"issue":"7","key":"pone.0285619.ref011","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1164\/rccm.200512-1942OC","article-title":"Lung Volume Recruitment after Surfactant Administration Modifies Spatial Distribution of Ventilation","volume":"174","author":"I Frerichs","year":"2006","journal-title":"American journal of respiratory and critical care medicine"},{"issue":"2","key":"pone.0285619.ref012","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/21\/2\/201","article-title":"Electrical Impedance Tomography (EIT) in Applications Related to Lung and Ventilation: A Review of Experimental and Clinical Activities","volume":"21","author":"I Frerichs","year":"2000","journal-title":"Physiological measurement"},{"issue":"7","key":"pone.0285619.ref013","doi-asserted-by":"crossref","first-page":"S261","DOI":"10.1088\/0967-3334\/28\/7\/S19","article-title":"Reproducibility of Regional Lung Ventilation Distribution Determined by Electrical Impedance Tomography during Mechanical Ventilation","volume":"28","author":"I Frerichs","year":"2007","journal-title":"Physiological measurement"},{"issue":"12","key":"pone.0285619.ref014","doi-asserted-by":"crossref","first-page":"2312","DOI":"10.1007\/s00134-003-2029-z","article-title":"Electrical Impedance Tomography: A Method for Monitoring Regional Lung Aeration and Tidal Volume Distribution?","volume":"29","author":"I Frerichs","year":"2003","journal-title":"Intensive care medicine"},{"issue":"3","key":"pone.0285619.ref015","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1007\/s00134-007-0786-9","article-title":"Assessment of Regional Lung Recruitment and Derecruitment during a PEEP Trial Based on Electrical Impedance Tomography","volume":"34","author":"T Meier","year":"2008","journal-title":"Intensive care medicine"},{"issue":"1","key":"pone.0285619.ref016","doi-asserted-by":"crossref","first-page":"R8","DOI":"10.1186\/cc8860","article-title":"PEEP Titration Guided by Ventilation Homogeneity: A Feasibility Study Using Electrical Impedance Tomography","volume":"14","author":"Z Zhao","year":"2010","journal-title":"Critical Care"},{"issue":"1","key":"pone.0285619.ref017","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1378\/chest.124.1.314","article-title":"Regional Ventilation by Electrical Impedance Tomography: A Comparison with Ventilation Scintigraphy in Pigs","volume":"124","author":"J Hinz","year":"2003","journal-title":"Chest"},{"issue":"7","key":"pone.0285619.ref018","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1164\/rccm.200301-133OC","article-title":"Imbalances in Regional Lung Ventilation: A Validation Study on Electrical Impedance Tomography","volume":"169","author":"JA Victorino","year":"2004","journal-title":"American journal of respiratory and critical care medicine"},{"issue":"1","key":"pone.0285619.ref019","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/2049-6958-7-44","article-title":"Dynamics of Regional Lung Aeration Determined by Electrical Impedance Tomography in Patients with Acute Respiratory Distress Syndrome","volume":"7","author":"S Pulletz","year":"2012","journal-title":"Multidisciplinary respiratory medicine"},{"issue":"7","key":"pone.0285619.ref020","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1152\/japplphysiol.01630.2011","article-title":"Spatial and Temporal Heterogeneity of Regional Lung Ventilation Determined by Electrical Impedance Tomography during Pulmonary Function Testing","volume":"113","author":"B Vogt","year":"2012","journal-title":"Journal of applied physiology"},{"issue":"1","key":"pone.0285619.ref021","doi-asserted-by":"crossref","first-page":"L8","DOI":"10.1152\/ajplung.00463.2015","article-title":"Regional Lung Response to Bronchodilator Reversibility Testing Determined by Electrical Impedance Tomography in Chronic Obstructive Pulmonary Disease","volume":"311","author":"B Vogt","year":"2016","journal-title":"American journal of physiology Lung cellular and molecular physiology"},{"issue":"11","key":"pone.0285619.ref022","doi-asserted-by":"crossref","first-page":"N107","DOI":"10.1088\/0967-3334\/34\/11\/N107","article-title":"Regional Airway Obstruction in Cystic Fibrosis Determined by Electrical Impedance Tomography in Comparison with High Resolution CT","volume":"34","author":"Z Zhao","year":"2013","journal-title":"Physiological measurement"},{"issue":"5","key":"pone.0285619.ref023","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/S2213-2600(20)30161-2","article-title":"Intensive Care Management of Coronavirus Disease 2019 (COVID-19): Challenges and Recommendations","volume":"8","author":"J Phua","year":"2020","journal-title":"The Lancet Respiratory medicine"},{"issue":"4","key":"pone.0285619.ref024","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s00059-020-04923-1","article-title":"Ventilation of COVID-19 Patients in Intensive Care Units","volume":"45","author":"S Mohlenkamp","year":"2020","journal-title":"Herz"},{"issue":"11","key":"pone.0285619.ref025","first-page":"1570","article-title":"Advanced Imaging in COPD: Insights into Pulmonary Pathophysiology","volume":"6","author":"S Milne","year":"2014","journal-title":"Journal of thoracic disease"},{"key":"pone.0285619.ref026","doi-asserted-by":"crossref","unstructured":"Zhao Z, Frerichs I, Pulletz S, M\u00fcller-Lisse U, M\u00f6ller K. Does Thorax EIT Image Analysis Depend on the Image Reconstruction Method? In: Journal of Physics: Conference Series. vol. 434. IOP Publishing; 2013. p. 012040.","DOI":"10.1088\/1742-6596\/434\/1\/012040"},{"issue":"11","key":"pone.0285619.ref027","doi-asserted-by":"crossref","first-page":"2494","DOI":"10.1109\/TBME.2017.2728323","article-title":"Electrical Impedance Tomography: Tissue Properties to Image Measures","volume":"64","author":"A Adler","year":"2017","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"5","key":"pone.0285619.ref028","doi-asserted-by":"crossref","first-page":"S103","DOI":"10.1088\/0967-3334\/27\/5\/S09","article-title":"Imaging of conductivity changes and electrode movement in EIT","volume":"27","author":"M Soleimani","year":"2006","journal-title":"Physiological Measurement"},{"issue":"2","key":"pone.0285619.ref029","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1109\/TBME.2008.2003103","article-title":"Real-Time Management of Faulty Electrodes in Electrical Impedance Tomography","volume":"56","author":"AE Hartinger","year":"2009","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"6","key":"pone.0285619.ref030","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1088\/0967-3334\/37\/6\/785","article-title":"3D EIT image reconstruction with GREIT","volume":"37","author":"B Grychtol","year":"2016","journal-title":"Physiological Measurement"},{"issue":"7","key":"pone.0285619.ref031","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1088\/0967-3334\/28\/7\/S01","article-title":"Temporal image reconstruction in electrical impedance tomography","volume":"28","author":"A Adler","year":"2007","journal-title":"Physiological Measurement"},{"issue":"4","key":"pone.0285619.ref032","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1109\/10.664204","article-title":"A Kalman filter approach to track fast impedance changes in electrical impedance tomography","volume":"45","author":"M Vauhkonen","year":"1998","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"4","key":"pone.0285619.ref033","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.3934\/ipi.2014.8.1013","article-title":"A Real-time D-bar Algorithm for 2-D Electrical Impedance Tomography Data","volume":"8","author":"M Dodd","year":"2014","journal-title":"Inverse problems and imaging (Springfield, Mo)"},{"issue":"6","key":"pone.0285619.ref034","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1088\/0967-3334\/30\/6\/S03","article-title":"GREIT: A Unified Approach to 2D Linear EIT Reconstruction of Lung Images","volume":"30","author":"A Adler","year":"2009","journal-title":"Physiological measurement"},{"issue":"6","key":"pone.0285619.ref035","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1088\/0967-3334\/36\/6\/1161","article-title":"A shape-based quality evaluation and reconstruction method for electrical impedance tomography","volume":"36","author":"CH Antink","year":"2015","journal-title":"Physiological Measurement"},{"issue":"5","key":"pone.0285619.ref036","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1088\/0967-3334\/33\/5\/739","article-title":"Level-set-based reconstruction algorithm for EIT lung images: first clinical results","volume":"33","author":"P Rahmati","year":"2012","journal-title":"Physiological Measurement"},{"issue":"1","key":"pone.0285619.ref037","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1109\/TMI.2009.2022540","article-title":"In Vivo Impedance Imaging With Total Variation Regularization","volume":"29","author":"A Borsic","year":"2010","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"9","key":"pone.0285619.ref038","doi-asserted-by":"crossref","first-page":"2090","DOI":"10.1109\/TMI.2018.2816739","article-title":"Image Reconstruction in Electrical Impedance Tomography Based on Structure-Aware Sparse Bayesian Learning","volume":"37","author":"S Liu","year":"2018","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"9","key":"pone.0285619.ref039","doi-asserted-by":"crossref","first-page":"5033","DOI":"10.1109\/TII.2019.2895469","article-title":"Accelerated Structure-Aware Sparse Bayesian Learning for Three-Dimensional Electrical Impedance Tomography","volume":"15","author":"S Liu","year":"2019","journal-title":"IEEE Transactions on Industrial Informatics"},{"issue":"10","key":"pone.0285619.ref040","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1109\/TMI.2018.2828303","article-title":"Deep D-Bar: Real-Time Electrical Impedance Tomography Imaging With Deep Neural Networks","volume":"37","author":"SJ Hamilton","year":"2018","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"7","key":"pone.0285619.ref041","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1088\/0967-3334\/32\/7\/S07","article-title":"Minimizing EIT Image Artefacts from Mesh Variability in Finite Element Models","volume":"32","author":"A Adler","year":"2011","journal-title":"Physiological measurement"},{"issue":"9","key":"pone.0285619.ref042","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1109\/TMI.2017.2716825","article-title":"EIT Imaging Regularization Based on Spectral Graph Wavelets","volume":"36","author":"B Gong","year":"2017","journal-title":"IEEE transactions on medical imaging"},{"key":"pone.0285619.ref043","doi-asserted-by":"crossref","first-page":"25951","DOI":"10.1038\/srep25951","article-title":"Structural-Functional Lung Imaging Using a Combined CT-EIT and a Discrete Cosine Transformation Reconstruction Method","volume":"6","author":"B Schullcke","year":"2016","journal-title":"Scientific reports"},{"key":"pone.0285619.ref044","unstructured":"Adler A, Arnold J, Bayford R, Borsic A, Brown B, Dixon P, et al. GREIT: Towards a Consensus EIT Algorithm for Lung Images. In: 9th International Conference on Biomedical Applications of Electrical Impedance Tomography. Dartmouth, NH, USA; 2008."},{"issue":"4","key":"pone.0285619.ref045","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1137\/090773970","article-title":"Exact Shape-Reconstruction by One-Step Linearization in Electrical Impedance Tomography","volume":"42","author":"B Harrach","year":"2010","journal-title":"SIAM Journal on Mathematical Analysis"},{"issue":"3","key":"pone.0285619.ref046","first-page":"407","article-title":"Computational Aspects of Low Frequency Electrical and Electromagnetic Tomography: A Review Study","volume":"5","author":"M Soleimani","year":"2008","journal-title":"Int J Numer Anal Model"},{"issue":"2","key":"pone.0285619.ref047","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1088\/0266-5611\/13\/2\/020","article-title":"Electrical Impedance Tomography with Basis Constraints","volume":"13","author":"M Vauhkonen","year":"1997","journal-title":"Inverse problems"},{"issue":"4A","key":"pone.0285619.ref048","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1088\/0143-0815\/9\/4A\/023","article-title":"A Regularised Electrical Impedance Tomography Reconstruction Algorithm","volume":"9","author":"P Hua","year":"1988","journal-title":"Clinical Physics and Physiological Measurement"},{"key":"pone.0285619.ref049","doi-asserted-by":"crossref","unstructured":"Grychtol B, Adler A. FEM Electrode Refinement for Electrical Impedance Tomography. Annual International Conference of the IEEE Engineering in Medicine and Biology Society IEEE Engineering in Medicine and Biology Society Annual International Conference. 2013;2013:6429\u201332.","DOI":"10.1109\/EMBC.2013.6611026"},{"key":"pone.0285619.ref050","unstructured":"Vauhkonen M. Electrical Impedance Tomography and Prior Information [PhD Thesis]. University of Kuopio. Kuopio, Finland; 1997."},{"issue":"2","key":"pone.0285619.ref051","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1109\/42.700740","article-title":"Tikhonov Regularization and Prior Information in Electrical Impedance Tomography","volume":"17","author":"M Vauhkonen","year":"1998","journal-title":"IEEE transactions on medical imaging"},{"issue":"6","key":"pone.0285619.ref052","doi-asserted-by":"crossref","first-page":"065006","DOI":"10.1088\/1361-6579\/ab1937","article-title":"Self-Weighted NOSER-Prior Electrical Impedance Tomography Using Internal Electrodes in Cardiac Radiofrequency Ablation","volume":"40","author":"DM Nguyen","year":"2019","journal-title":"Physiological measurement"},{"issue":"12","key":"pone.0285619.ref053","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1088\/0957-0233\/13\/12\/310","article-title":"A Matlab Toolkit for Three-Dimensional Electrical Impedance Tomography: A Contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software Project","volume":"13","author":"N Polydorides","year":"2002","journal-title":"Measurement science and technology"},{"issue":"3","key":"pone.0285619.ref054","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1088\/1361-6579\/aa5b78","article-title":"Methods for Calculating the Electrode Position Jacobian for Impedance Imaging","volume":"38","author":"A Boyle","year":"2017","journal-title":"Physiological measurement"},{"issue":"6","key":"pone.0285619.ref055","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1088\/0967-3334\/34\/6\/579","article-title":"Uniform Background Assumption Produces Misleading Lung EIT Images","volume":"34","author":"B Grychtol","year":"2013","journal-title":"Physiological measurement"},{"issue":"1","key":"pone.0285619.ref056","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1109\/T-C.1974.223784","article-title":"Discrete Cosine Transform","volume":"100","author":"N Ahmed","year":"1974","journal-title":"IEEE transactions on Computers"},{"issue":"3","key":"pone.0285619.ref057","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/ALN.0000000000002583","article-title":"Imaging the Injured Lung: Mechanisms of Action and Clinical Use","volume":"131","author":"M Cereda","year":"2019","journal-title":"Anesthesiology"},{"issue":"5","key":"pone.0285619.ref058","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1088\/0967-3334\/27\/5\/S03","article-title":"Uses and Abuses of EIDORS: An Extensible Software Base for EIT","volume":"27","author":"A Adler","year":"2006","journal-title":"Physiological measurement"},{"issue":"1","key":"pone.0285619.ref059","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s007910050004","article-title":"NETGEN An Advancing Front 2D\/3D-Mesh Generator Based on Abstract Rules","volume":"1","author":"J Sch\u00f6berl","year":"1997","journal-title":"Computing and visualization in science"},{"issue":"5","key":"pone.0285619.ref060","doi-asserted-by":"crossref","first-page":"S65","DOI":"10.1088\/0967-3334\/27\/5\/S06","article-title":"Objective Selection of Hyperparameter for EIT","volume":"27","author":"B Graham","year":"2006","journal-title":"Physiological measurement"},{"issue":"11","key":"pone.0285619.ref061","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1007\/s00134-009-1589-y","article-title":"Evaluation of an Electrical Impedance Tomography-Based Global Inhomogeneity Index for Pulmonary Ventilation Distribution","volume":"35","author":"Z Zhao","year":"2009","journal-title":"Intensive care medicine"},{"key":"pone.0285619.ref062","doi-asserted-by":"crossref","DOI":"10.3389\/fmed.2022.747570","article-title":"Differentiating Phenotypes of Coronavirus Disease-2019 Pneumonia by Electric Impedance Tomography","volume":"9","author":"A Lovas","year":"2022","journal-title":"Frontiers in Medicine"},{"key":"pone.0285619.ref063","doi-asserted-by":"crossref","unstructured":"Nakanishi RM, Santos TBR, Amato MBP, Lima RG. A Measure of Prior Information of a Pathology in an EIT Anatomical Atlas. In: Bertemes-Filho P, editor. 17th International Conference on Electrical Bioimpedance. Singapore: Springer Singapore; 2020. p. 173\u2013180.","DOI":"10.1007\/978-981-13-3498-6_26"},{"key":"pone.0285619.ref064","first-page":"1","article-title":"Supervised Descent Learning for Thoracic Electrical Impedance Tomography","author":"K Zhang","year":"2020","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"5","key":"pone.0285619.ref065","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0920-5489(02)00069-7","article-title":"Software defined QCIF simple profile MPEG-4 for portable devices using dynamically reconfigurable DSP","volume":"24","author":"JG Chase","year":"2002","journal-title":"Computer Standards & Interfaces"},{"issue":"2","key":"pone.0285619.ref066","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1088\/0967-3334\/34\/2\/163","article-title":"Interaction of Dependent and Non-Dependent Regions of the Acutely Injured Lung during a Stepwise Recruitment Manoeuvre","volume":"34","author":"C G\u00f3mez-Laberge","year":"2013","journal-title":"Physiological measurement"},{"key":"pone.0285619.ref067","doi-asserted-by":"crossref","unstructured":"Chen R, Moeller K. Redistribution Index\u2014Detection of an Outdated Prior Information in the Discrete Cosine Transformation-Based EIT Algorithm. In: 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE; 2021.","DOI":"10.1109\/EMBC46164.2021.9630567"},{"issue":"2","key":"pone.0285619.ref068","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1164\/rccm.200607-915OC","article-title":"Tidal Hyperinflation during Low Tidal Volume Ventilation in Acute Respiratory Distress Syndrome","volume":"175","author":"PP Terragni","year":"2007","journal-title":"American journal of respiratory and critical care medicine"},{"key":"pone.0285619.ref069","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.arcontrol.2019.05.002","article-title":"A Review of Electrical Impedance Tomography in Lung Applications: Theory and Algorithms for Absolute Images","volume":"48","author":"T de Castro Martins","year":"2019","journal-title":"Annual reviews in control"},{"issue":"6","key":"pone.0285619.ref070","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1007\/s00134-020-06033-2","article-title":"COVID-19 Pneumonia: Different Respiratory Treatments for Different Phenotypes?","volume":"46","author":"L Gattinoni","year":"2020","journal-title":"Intensive Care Medicine"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0285619","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T17:26:02Z","timestamp":1683825962000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0285619"}},"subtitle":[],"editor":[{"given":"Mohamed Kamel","family":"Riahi","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":70,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,5,11]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0285619","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,11]]}}}