{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T04:30:32Z","timestamp":1781325032230,"version":"3.54.1"},"reference-count":14,"publisher":"Public Library of Science (PLoS)","issue":"11","license":[{"start":{"date-parts":[[2023,11,30]],"date-time":"2023-11-30T00:00:00Z","timestamp":1701302400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000065","name":"National Institute of Neurological Disorders and Stroke","doi-asserted-by":"publisher","award":["R01NS094570"],"award-info":[{"award-number":["R01NS094570"]}],"id":[{"id":"10.13039\/100000065","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Introduction<\/jats:title>\n<jats:p>The mechanisms of catheter obstruction are still poorly understood, but the literature suggests that resistance to fluid flow plays a significant role. We developed and assessed a gravity-driven device that measures flow through ventricular catheters. We used this device to quantitatively analyze the resistances of unused ventricular catheters used in the treatment of hydrocephalus; failed hydrocephalus catheters from our catheter biorepository were also evaluated quantitatively.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Methods<\/jats:title>\n<jats:p>Catheters of three manufacturing companies were inserted into the benchtop model, which records time, flow rate, and pressure data using sensors. The relative resistances of catheters across six design models were evaluated. Experiments were performed to evaluate changes in the relative resistance of a catheter when the catheter\u2019s holes were progressively closed. The relative resistance of explanted catheters from our catheter biorepository was also measured.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Results<\/jats:title>\n<jats:p>Experimental results showed significant differences (<jats:italic>P<\/jats:italic>&lt;0.05) between the relative resistances of different catheter models just after being removed from their packaging. A non-linear trend of increasing resistance was observed in experiments on catheters with artificially obstructed holes. Data from five individual benchtop models were compared, and the differences in measured data between the models were found to be negligible. A significant increase (<jats:italic>P<\/jats:italic> &lt; 0.05) in relative resistance was observed in explanted catheters.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec004\">\n<jats:title>Conclusion<\/jats:title>\n<jats:p>The current study sought to propose a novel in-vitro model and use it to examine data on differences in relative resistance among catheter models. From these experiments, we can rapidly correlate clinical patient cohorts to identify mechanisms of luminal shunt obstruction.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0294811","type":"journal-article","created":{"date-parts":[[2023,11,30]],"date-time":"2023-11-30T18:31:11Z","timestamp":1701369071000},"page":"e0294811","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":5,"title":["A novel, benchtop model for quantitative analysis of resistance in ventricular catheters"],"prefix":"10.1371","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8361-0132","authenticated-orcid":true,"given":"Pranav","family":"Gopalakrishnan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad","family":"Faryami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9700-7457","authenticated-orcid":true,"given":"Carolyn A.","family":"Harris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2023,11,30]]},"reference":[{"key":"pone.0294811.ref001","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1007\/s003810000351","article-title":"CSF shunts 50 Years On\u2014past, present and future.","volume":"16","author":"J. M. Drake","year":"2000","journal-title":"Child\u2019s Nervous System"},{"key":"pone.0294811.ref002","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1159\/000055960","article-title":"Long-term follow-up data from the Shunt Design Trial.","volume":"33","author":"J. Kestle","year":"2000","journal-title":"Pediatric Neurosurgery"},{"key":"pone.0294811.ref003","doi-asserted-by":"crossref","first-page":"426","DOI":"10.3171\/jns.2003.99.2.0426","article-title":"Computational and experimental study of proximal flow in ventricular catheters","volume":"99","author":"J. Lin","year":"2003","journal-title":"Journal of Neurosurgery"},{"key":"pone.0294811.ref004","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s00381-013-2226-1","article-title":"Computational fluid dynamics of ventricular catheters used for the treatment of hydrocephalus: A 3D analysis.","volume":"30","author":"M. Galarza","year":"2013","journal-title":"Child\u2019s Nervous System"},{"key":"pone.0294811.ref005","doi-asserted-by":"crossref","DOI":"10.1186\/s12987-020-00211-6","article-title":"Characterization of a multicenter pediatric-hydrocephalus shunt biobank.","volume":"17","author":"J. Gluski","year":"2020","journal-title":"Fluids and Barriers of the CNS"},{"key":"pone.0294811.ref006","doi-asserted-by":"crossref","DOI":"10.1186\/s12987-021-00262-3","article-title":"A multicenter retrospective study of heterogeneous tissue aggregates obstructing ventricular catheters explanted from patients with hydrocephalus.","volume":"18","author":"P. Hariharan","year":"2021","journal-title":"Fluids and Barriers of the CNS"},{"key":"pone.0294811.ref007","doi-asserted-by":"crossref","first-page":"213","DOI":"10.3171\/jns.1987.66.2.0213","article-title":"A new approach in the treatment of hydrocephalus","volume":"66","author":"C. Sainte-Rose","year":"1987","journal-title":"Journal of Neurosurgery"},{"key":"pone.0294811.ref008","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-019-46328-z","article-title":"An electrical model of hydrocephalus shunt incorporating the CSF Dynamics.","volume":"9","author":"R. Baghbani","year":"2019","journal-title":"Scientific Reports"},{"key":"pone.0294811.ref009","first-page":"191","article-title":"Flow characteristics of cerebrospinal fluid shunt tubing. Journal of Neurosurgery","volume":"9","author":"J. T. Cheatle","year":"2012","journal-title":"Pediatrics"},{"issue":"10","key":"pone.0294811.ref010","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.3390\/children9101453","article-title":"Partial obstruction of ventricular catheters affects performance in a new catheter obstruction model of hydrocephalus.","volume":"9","author":"S Lee","year":"2022","journal-title":"Children"},{"key":"pone.0294811.ref011","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1007\/s00381-011-1430-0","article-title":"Does drainage hole size influence adhesion on ventricular catheters?","volume":"27","author":"C. A. Harris","year":"2011","journal-title":"Child\u2019s Nervous System"},{"key":"pone.0294811.ref012","first-page":"1221","article-title":"Ventricular catheters for hydrocephalus.","author":"M. Galarza","year":"2019","journal-title":"Pediatric Hydrocephalus"},{"key":"pone.0294811.ref013","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1007\/s00381-009-1055-8","article-title":"Perforation holes in ventricular catheters\u2014is less more?.","volume":"26","author":"U.W. Thomale","year":"2010","journal-title":"Childs Nerv Syst"},{"key":"pone.0294811.ref014","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0262372","article-title":"Testing and validation of reciprocating positive displacement pump for benchtop pulsating flow model of cerebrospinal fluid production and other physiologic systems.","volume":"17","author":"A. Faryami","year":"2022","journal-title":"PLOS ONE"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0294811","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,30]],"date-time":"2023-11-30T18:31:25Z","timestamp":1701369085000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0294811"}},"subtitle":[],"editor":[{"given":"Naveen","family":"Jayaprakash","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2023,11,30]]},"references-count":14,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,11,30]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0294811","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,30]]}}}