{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T00:35:10Z","timestamp":1789605310357,"version":"build-2803163510"},"reference-count":32,"publisher":"Public Library of Science (PLoS)","issue":"3","license":[{"start":{"date-parts":[[2024,3,21]],"date-time":"2024-03-21T00:00:00Z","timestamp":1710979200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Objective<\/jats:title>\n<jats:p>This study aimed to analyze the prevalence, risk factors, and clinical implications of hemolyzed laboratory samples in the pediatric emergency department (ED), a subject on which existing data remains scarce.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Methods<\/jats:title>\n<jats:p>We conducted a multi-site observational cohort analysis of pediatric ED encounters in Metro Detroit, Michigan, United States. The study included participants below 18 years of age who had undergone peripheral intravenous catheter (PIVC) placement and laboratory testing. The primary outcome was the presence of hemolysis, and secondary outcomes included identifying risk factors for hemolysis and assessing the impact of hemolysis on PIVC failure.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Results<\/jats:title>\n<jats:p>Between January 2021 and May 2022, 10,462 ED encounters met inclusion criteria, of which 14.0% showed laboratory evidence of hemolysis. The highest proportion of hemolysis occurred in the infant (age 0\u20131) population (20.1%). Multivariable regression analysis indicated higher odds of hemolysis for PIVCs placed in the hand\/wrist in the toddler (age 2\u20135) and child (age 6\u201311) subgroups. PIVCs placed in the hand\/wrist also demonstrated higher odds of failure in infants.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec004\">\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Hemolysis in the pediatric ED population is a frequent complication that occurs at similar rates as in adults. PIVCs placed in the hand\/wrist were associated with higher odds of hemolysis compared to those placed in the antecubital fossa. Clinicians should consider alternative locations for PIVC placement if clinically appropriate. Further research is needed to better understand the clinical implications of pediatric hemolysis.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0299692","type":"journal-article","created":{"date-parts":[[2024,3,21]],"date-time":"2024-03-21T17:42:12Z","timestamp":1711042932000},"page":"e0299692","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":2,"title":["Pediatric hemolysis in emergency departments: Prevalence, risk factors, and clinical implications"],"prefix":"10.1371","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2461-427X","authenticated-orcid":true,"given":"Nicholas","family":"Mielke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ray","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Bahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2024,3,21]]},"reference":[{"issue":"3","key":"pone.0299692.ref001","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/10408363.2011.600228","article-title":"Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories","volume":"48","author":"G Lippi","year":"2011","journal-title":"Crit Rev Clin Lab Sci"},{"key":"pone.0299692.ref002","unstructured":"Emergency Nurses Association. Clinical Practice Guideline: Prevention of Blood Specimen Hemolysis in Peripherally-Collected Venous Specimens [Internet]. 2020. www.ena.org"},{"issue":"5","key":"pone.0299692.ref003","doi-asserted-by":"crossref","DOI":"10.1002\/jcla.22396","article-title":"Interference of in vitro hemolysis complete blood count","volume":"32","author":"G de Jonge","year":"2018","journal-title":"J Clin Lab Anal"},{"issue":"3","key":"pone.0299692.ref004","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1515\/CCLM.2006.054","article-title":"Influence of hemolysis on routine clinical chemistry testing","volume":"44","author":"G Lippi","year":"2006","journal-title":"Clin Chem Lab Med"},{"issue":"6","key":"pone.0299692.ref005","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1515\/CCLM.2008.170","article-title":"Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories","volume":"46","author":"G Lippi","year":"2008","journal-title":"Clin Chem Lab Med"},{"issue":"5","key":"pone.0299692.ref006","doi-asserted-by":"crossref","first-page":"474","DOI":"10.4037\/ajcc2009686","article-title":"Obtaining blood samples from peripheral intravenous catheters: best practice?","volume":"18","author":"MA Halm","year":"2009","journal-title":"Am J Crit Care"},{"issue":"12","key":"pone.0299692.ref007","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.clinbiochem.2013.04.005","article-title":"Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters","volume":"46","author":"C Heiligers-Duckers","year":"2013","journal-title":"Clin Biochem"},{"issue":"2","key":"pone.0299692.ref008","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1309\/LM2XCV5SQML1ONTM","article-title":"Blood collection from intravenous lines: is one drawing site better than others?","volume":"45","author":"G Lippi","year":"2014","journal-title":"Lab Med"},{"key":"pone.0299692.ref009","article-title":"Hemolyzed Laboratory Specimens in the Emergency Department: An Underappreciated, but Frequent Problem","author":"R Calleja","year":"2023","journal-title":"J Emerg Nurs"},{"issue":"4","key":"pone.0299692.ref010","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1542\/peds.2012-1181","article-title":"Translational research in pediatrics II: blood collection, processing, shipping, and storage","volume":"131","author":"C Gillio-Meina","year":"2013","journal-title":"Pediatrics"},{"issue":"1","key":"pone.0299692.ref011","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1093\/labmed\/lmz026","article-title":"Residual Negative Pressure in Vacuum Blood-Collection Tube and Hemolysis in Pediatric Blood Specimens","volume":"51","author":"J Hu","year":"2020","journal-title":"Lab Med"},{"issue":"2","key":"pone.0299692.ref012","doi-asserted-by":"crossref","DOI":"10.5858\/arpa.2016-0400-OA","article-title":"Preanalytic factors associated with hemolysis in emergency department blood samples","volume":"142","author":"MP Phelan","year":"2018","journal-title":"Arch Pathol Lab Med"},{"issue":"2","key":"pone.0299692.ref013","first-page":"153","article-title":"Factors related to haemolysis in the extraction of blood samples","volume":"31","author":"MD Ag\u00f3s Romeo","year":"2008","journal-title":"An Sist Sanit Navar"},{"issue":"2","key":"pone.0299692.ref014","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/MEJ.0000000000000195","article-title":"Factors affecting blood sample haemolysis: a cross-sectional study","volume":"23","author":"EBG Barnard","year":"2016","journal-title":"Eur J Emerg Med"},{"issue":"1","key":"pone.0299692.ref015","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jen.2022.08.005","article-title":"A Single-Center Prospective Study of the Effects of Different Methods of Phlebotomy in the Emergency Department on Blood Sample Hemolysis Rates","volume":"49","author":"S Ersoy","year":"2023","journal-title":"J Emerg Nurs"},{"issue":"4","key":"pone.0299692.ref016","article-title":"Assessing pediatric trauma specimen integrity","volume":"23","author":"RA Bush","year":"2010","journal-title":"Clin Lab Sci"},{"issue":"1","key":"pone.0299692.ref017","doi-asserted-by":"crossref","first-page":"e179","DOI":"10.1542\/peds.2009-2920","article-title":"Blood Sampling Through Peripheral Venous Catheters Is Reliable for Selected Basic Analytes in Children","volume":"126","author":"S Berger-Achituv","year":"2010","journal-title":"Pediatrics"},{"issue":"SUPPL. 3","key":"pone.0299692.ref018","article-title":"Clinical implications of unmanaged needle-insertion pain and distress in children","volume":"122 Suppl 3","author":"RM Kennedy","year":"2008","journal-title":"Pediatrics"},{"issue":"SUPPL. 3","key":"pone.0299692.ref019","article-title":"Optimizing the management of peripheral venous access pain in children: evidence, impact, and implementation","volume":"122 Suppl 3","author":"WT Zempsky","year":"2008","journal-title":"Pediatrics"},{"issue":"1","key":"pone.0299692.ref020","doi-asserted-by":"crossref","DOI":"10.1186\/s12887-015-0438-0","article-title":"Comforting strategies and perceived barriers to pediatric pain management during IV line insertion procedure in Uganda\u2019s national referral hospital: A descriptive study","volume":"15","author":"G Katende","year":"2015","journal-title":"BMC Pediatr"},{"issue":"1","key":"pone.0299692.ref021","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1542\/peds.90.1.87","article-title":"The Occurrence of High Levels of Acute Behavioral Distress in Children and Adolescents Undergoing Routine Venipunctures","volume":"90","author":"GB Humphrey","year":"1992","journal-title":"Pediatrics"},{"issue":"1","key":"pone.0299692.ref022","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/0304-3959(90)91050-S","article-title":"A prospective survey of reactions to blood tests by children and adolescents","volume":"40","author":"C Fradet","year":"1990","journal-title":"Pain"},{"issue":"6","key":"pone.0299692.ref023","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1001\/archpedi.161.6.578","article-title":"Caregivers\u2019 responses to pain in their children in the emergency department","volume":"161","author":"RW Smith","year":"2007","journal-title":"Arch Pediatr Adolesc Med"},{"issue":"2","key":"pone.0299692.ref024","doi-asserted-by":"crossref","first-page":"32","DOI":"10.7748\/paed.22.2.32.s29","article-title":"Evaluating venepuncture practice on a general children\u2019s ward","volume":"22","author":"C Hands","year":"2010","journal-title":"Paediatr Nurs"},{"issue":"3","key":"pone.0299692.ref025","article-title":"Pediatrician-Reported Injury Prevention Anticipatory Guidance by Patient Age Group. Acad Pediatr","volume":"23","author":"WH Burr","year":"2023","journal-title":"Internet]"},{"issue":"2","key":"pone.0299692.ref026","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2022-059037","article-title":"Codetections of Other Respiratory Viruses Among Children Hospitalized With COVID-19","volume":"151","author":"NT Agathis","year":"2023","journal-title":"Pediatrics"},{"issue":"3","key":"pone.0299692.ref027","doi-asserted-by":"crossref","DOI":"10.1542\/peds.2017-2151","article-title":"Age limit of pediatrics","volume":"140","author":"AP Hardin","year":"2017","journal-title":"Pediatrics"},{"key":"pone.0299692.ref028","unstructured":"US Department of Health and Human Services. Development & Approval Process (Drugs). Forms & Submission Requirements. Pediatric Exclusivity Study Age Group [Internet]. [cited 2023 Jul 1]. https:\/\/www.fda.gov\/drugs\/data-standards-manual-monographs\/pediatric-exclusivity-study-age-group"},{"issue":"4","key":"pone.0299692.ref029","doi-asserted-by":"crossref","DOI":"10.1093\/jalm\/jfaa073","article-title":"Seeing Red: Blood Sample Hemolysis Is Associated with Prolonged Emergency Department Throughput","volume":"5","author":"MP Phelan","year":"2020","journal-title":"J Appl Lab Med"},{"issue":"1","key":"pone.0299692.ref030","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12912-022-00840-2","article-title":"Nurses\u2019 experiences of blood sample collection from children: a qualitative study from Swedish paediatric hospital care","volume":"21","author":"H Hjelmgren","year":"2022","journal-title":"BMC Nurs"},{"issue":"1S Suppl 1","key":"pone.0299692.ref031","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000396","article-title":"Infusion Therapy Standards of Practice, 8th Edition","volume":"44","author":"LA Gorski","year":"2021","journal-title":"Journal of Infusion Nursing"},{"issue":"3","key":"pone.0299692.ref032","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/PEC.0000000000001493","article-title":"Impact of Peripheral Venous Catheter Placement With Vein Visualization Device Support on Success Rate and Pain Levels in Pediatric Patients Aged 0 to 3 Years","volume":"37","author":"S Inal","year":"2021","journal-title":"Pediatr Emerg Care"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0299692","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,21]],"date-time":"2024-03-21T17:42:33Z","timestamp":1711042953000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0299692"}},"subtitle":[],"editor":[{"given":"Theresa Ukamaka","family":"Nwagha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2024,3,21]]},"references-count":32,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,3,21]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0299692","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,21]]}}}