{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T11:26:08Z","timestamp":1751541968480,"version":"3.40.5"},"reference-count":13,"publisher":"Public Library of Science (PLoS)","issue":"3","license":[{"start":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T00:00:00Z","timestamp":1710460800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Intermaxillary fixation (IMF) or maxillo-mandibular fixation (MMF) is a fundamental process in stabilizing the maxilla and mandible through dental maximum intercuspation (MIP) during the management of trauma, orthognathic surgery, and reconstruction. Despite the availability of several techniques in achieving adequate maxillo-mandibular fixation, concerns have been raised regarding the sufficiency of using only latex elastics to counter displacing forces during reduction and fixation. To address this, an in vitro study was conducted to compare the efficacy of three maxillo-mandibular fixation methods: wire, elastics, and a combination of both. Custom-made models simulating dental arches were used, and a vertical separation of up to 1 mm was applied at a loading rate of 1 mm\/minute using an Instron 5566 Universal Testing Machine. Tensile loads were recorded at 0.5 and 1 mm vertical separation, with each process repeated 10 times in each sample group. The average peak tensile load was then calculated. Statistical analysis using one-way ANOVA at a significance level of p&lt;0.05 revealed significant differences between all three subject groups. The outcomes of this in vitro study suggest that the combination technique (using both wire and elastics) outperformed the individual methods in achieving robust maxillo-mandibular fixation. This positions the combination technique as the most effective among the evaluated fixation methods.<\/jats:p>","DOI":"10.1371\/journal.pone.0300481","type":"journal-article","created":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T17:45:20Z","timestamp":1710524720000},"page":"e0300481","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":1,"title":["An in vitro study in separating tensile loads during maxillo-mandibular fixation using wire and\/or elastics"],"prefix":"10.1371","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8810-4992","authenticated-orcid":true,"given":"Sudeep","family":"Pawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3693-7447","authenticated-orcid":true,"given":"Surakit","family":"Visuttiwattanakorn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2024,3,15]]},"reference":[{"issue":"2","key":"pone.0300481.ref001","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1055\/s-0030-1254376","article-title":"The use of MMF screws: Surgical technique, indications, contraindications, and common problems in review of the literature","volume":"3","author":"C-P Cornelius","year":"2010","journal-title":"Craniomaxillofacial Trauma & Reconstruction"},{"issue":"4","key":"pone.0300481.ref002","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/0266-4356(93)90150-U","article-title":"The use of orthodontic chain elastic for temporary intermaxillary fixation","volume":"31","author":"AT Smith","year":"1993","journal-title":"British Journal of Oral and Maxillofacial Surgery"},{"issue":"12","key":"pone.0300481.ref003","doi-asserted-by":"crossref","DOI":"10.4172\/2161-1122.1000467","article-title":"Use of mandibulo-maxillary fixation screws for the treatment of maxillofacial fractures","volume":"7","author":"S Manjrekar","year":"2017","journal-title":"Dentistry"},{"issue":"1","key":"pone.0300481.ref004","doi-asserted-by":"crossref","first-page":"25","DOI":"10.4103\/2231-0746.186129","article-title":"Intermaxillary fixation screws versus Erich arch bars in mandibular fractures: A comparative study and review of literature","volume":"6","author":"A Qureshi","year":"2016","journal-title":"Annals of Maxillofacial Surgery"},{"issue":"4","key":"pone.0300481.ref005","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1097\/00006534-197410000-00022","article-title":"Intermaxillary fixation with orthodontic brackets bonded to teeth","volume":"54","author":"R Minami","year":"1974","journal-title":"Plastic and Reconstructive Surgery"},{"issue":"4","key":"pone.0300481.ref006","doi-asserted-by":"crossref","first-page":"146","DOI":"10.4103\/2155-8213.140592","article-title":"Force relaxation of 3\/16 inch heavy orthodontic latex elastics used in maxillofacial trauma in simulated jaw fracture situation","volume":"5","author":"S Khajehahmadi","year":"2014","journal-title":"Dental Hypotheses"},{"issue":"2","key":"pone.0300481.ref007","article-title":"Role of orthodontic elastics in the oral & maxillofacial surgical procedures","volume":"8","author":"R Kanitkar","year":"2020","journal-title":"Journal of Advanced Medical and Dental Sciences Research"},{"key":"pone.0300481.ref008","article-title":"Improving accuracy of the intermediate splint in substantial intermaxillary sagittal discrepancies using an extra anterior anchorage point: Technical note","author":"F Hern\u00e1ndez-Alfaro","year":"2021","journal-title":"Medicina Oral Patolog\u00eda Oral y Cirugia Bucal"},{"issue":"4","key":"pone.0300481.ref009","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/j.coms.2017.07.008","article-title":"Controversies in orthognathic surgery","volume":"29","author":"DE Perez","year":"2017","journal-title":"Oral and Maxillofacial Surgery Clinics of North America"},{"issue":"1","key":"pone.0300481.ref010","doi-asserted-by":"crossref","first-page":"35","DOI":"10.5334\/aogh.2698","article-title":"Global prevalence and device related causes of needle stick injuries among health care workers: A systematic review and meta-analysis","volume":"86","author":"S Bouya","year":"2020","journal-title":"Annals of Global Health"},{"issue":"3","key":"pone.0300481.ref011","first-page":"230","article-title":"Maximum Opening and Closing Forces Exerted by Diverse Skeletal Types","volume":"41","author":"Erkut Yilridum","year":"1971","journal-title":"Angle Orthod"},{"issue":"1","key":"pone.0300481.ref012","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1111\/ocr.12215","article-title":"Estimation of jaw-opening forces in adults","volume":"21","author":"PA Brunton","year":"2017","journal-title":"Orthodontics & Craniofacial Research"},{"issue":"1","key":"pone.0300481.ref013","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1080\/10803548.2004.11076594","article-title":"Isometric pull-push strengths in workspace: 1","volume":"10","author":"B Das","year":"2004","journal-title":"Strength Profiles. International Journal of Occupational Safety and Ergonomics"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0300481","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T17:45:43Z","timestamp":1710524743000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0300481"}},"subtitle":[],"editor":[{"given":"Sompop","family":"Bencharit","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2024,3,15]]},"references-count":13,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,3,15]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0300481","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2024,3,15]]}}}