{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:22:08Z","timestamp":1791436928897,"version":"4.3.3"},"reference-count":39,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T00:00:00Z","timestamp":1717977600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>This study aimed to develop and analyze the accuracy of predictive formulae for postoperative anterior chamber depth, tilt, and decentration of low-added-segment refractive intraocular lenses. This single-center, retrospective, observational study included the right eyes of 96 patients (mean age: 72.43 \u00b1 6.58 years), who underwent a cataract surgery with implantation of a low-added segmented refractive intraocular lens at the Medical University Hospital between July 2019 and January 2021, and were followed up for more than 1 month postoperatively. The participants were divided into an estimation group to create a prediction formula and a validation group to verify the accuracy of the formula. Anterior segment optical coherence tomography (CASIA 2, Tomey Corporation, Japan) and swept-source optical coherence tomography biometry (IOL Master 700, Carl Zeiss Meditec AG) were used to measure the anterior ocular components. A predictive formula was devised for postoperative anterior chamber depth, intraocular lens tilt, and intraocular lens decentration (p &lt;0.01) in the estimation group. A significant positive correlation was observed between the estimated values calculated using the prediction formula and the measured values for postoperative anterior chamber depth (r = 0.792), amount of intraocular lens tilt (r = 0.610), direction of intraocular lens tilt (r = 0.668), and amount of intraocular lens decentration (r = 0.431) (p &lt; 0.01) in the validation group. In conclusion, our findings reveal that predicting the position of the low-added segmented refractive intraocular lens enables the prognosis of postoperative refractive values with a greater accuracy in determining the intraocular lens adaptation.<\/jats:p>","DOI":"10.1371\/journal.pone.0305076","type":"journal-article","created":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T17:31:44Z","timestamp":1718040704000},"page":"e0305076","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":3,"title":["Prediction of low-addition segmented refractive intraocular lens position and deviation using anterior-segment optical coherence tomography"],"prefix":"10.1371","volume":"19","author":[{"given":"Norihiro","family":"Mita","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Seki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eri","family":"Shibuya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7672-9947","authenticated-orcid":true,"given":"Tsuyoshi","family":"Mito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natsuko","family":"Hatsusaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6789-9311","authenticated-orcid":true,"given":"Eri","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6458-5330","authenticated-orcid":true,"given":"Hiroshi","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2024,6,10]]},"reference":[{"key":"pone.0305076.ref001","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/S0140-6736(52)92426-4","article-title":"Intra-ocular acrylic lenses after cataract extraction","volume":"1","author":"H. Ridley","year":"1952","journal-title":"Lancet"},{"key":"pone.0305076.ref002","doi-asserted-by":"crossref","first-page":"2687385","DOI":"10.1155\/2018\/2687385","article-title":"Biomaterial influence on intraocular lens performance: An overview","volume":"2018","author":"C. P\u00e9rez-Vives","year":"2018","journal-title":"J Ophthalmol"},{"key":"pone.0305076.ref003","doi-asserted-by":"crossref","first-page":"753","DOI":"10.2147\/OPTH.S133207","article-title":"Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820.","volume":"11","author":"G Labiris","year":"2017","journal-title":"Clin Ophthalmol."},{"key":"pone.0305076.ref004","doi-asserted-by":"crossref","first-page":"e0200197","DOI":"10.1371\/journal.pone.0200197","article-title":"Fractal-structured multifocal intraocular lens.","volume":"13","author":"L Rem\u00f3n","year":"2018","journal-title":"PLOS ONE"},{"key":"pone.0305076.ref005","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of intraocular lens calculation formulas","volume":"125","author":"RB Melles","year":"2018","journal-title":"Ophthalmology"},{"key":"pone.0305076.ref006","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation","volume":"34","author":"S. Norrby","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref007","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1016\/j.jcrs.2019.01.023","article-title":"Pilot evaluation of refractive prediction errors associated with a new method for ray-tracing-based intraocular lens power calculation.","volume":"45","author":"N Hirnschall","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref008","doi-asserted-by":"crossref","first-page":"6501","DOI":"10.1038\/s41598-020-63546-y","article-title":"Development of a new intraocular lens power calculation method based on lens position estimated with optical coherence tomography","volume":"10","author":"T Satou","year":"2020","journal-title":"Sci Rep"},{"key":"pone.0305076.ref009","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","article-title":"Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye.","volume":"45","author":"T Lawu","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref010","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.2147\/OPTH.S72053","article-title":"Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.","volume":"8","author":"T Fujikado","year":"2014","journal-title":"Clin Ophthalmol."},{"key":"pone.0305076.ref011","doi-asserted-by":"crossref","first-page":"e0232546","DOI":"10.1371\/journal.pone.0232546","article-title":"Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors.","volume":"15","author":"J P\u00e9rez-Gracia","year":"2020","journal-title":"PLOS ONE."},{"key":"pone.0305076.ref012","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/j.jcrs.2009.01.023","article-title":"Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations.","volume":"35","author":"M Baumeister","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref013","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.ajo.2005.04.026","article-title":"Ocular higher-order wavefront aberration caused by major tilting of intraocular lens","volume":"140","author":"T Oshika","year":"2005","journal-title":"Am J Ophthalmol"},{"key":"pone.0305076.ref014","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1016\/j.ophtha.2016.09.005","article-title":"Prediction of postoperative intraocular lens position with angle-to-angle depth using anterior segment optical coherence tomography","volume":"123","author":"S Goto","year":"2016","journal-title":"Ophthalmology"},{"key":"pone.0305076.ref015","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1159\/000065597","article-title":"Predicting postoperative anterior chamber depth in cataract patients using Scheimpflug slit photography","volume":"34","author":"H Sasaki","year":"2002","journal-title":"Ophthalmic Res"},{"key":"pone.0305076.ref016","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.ajo.2018.09.005","article-title":"Use of the crystalline lens equatorial plane as a new parameter for predicting postoperative intraocular lens position","volume":"198","author":"YS Yoo","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"pone.0305076.ref017","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jcrs.2017.01.026","article-title":"Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography.","volume":"43","author":"N Hirnschall","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref018","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1007\/s10792-017-0652-x","article-title":"Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.","volume":"38","author":"E Pedrotti","year":"2018","journal-title":"Int Ophthalmol."},{"key":"pone.0305076.ref019","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.jcrs.2017.01.024","article-title":"Bifocal nondiffractive intraocular lens for enhanced depth of focus in correcting presbyopia: Clinical evaluation.","volume":"43","author":"E Vounotrypidis","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref020","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1186\/s12886-020-01731-3","article-title":"Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of +\u20091.5 diopters.","volume":"20","author":"T Oshika","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"pone.0305076.ref021","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.jcrs.2010.08.043","article-title":"Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens.","volume":"37","author":"JL Ali\u00f3","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref022","doi-asserted-by":"crossref","first-page":"93","DOI":"10.3928\/1081597X-20111213-02","article-title":"Correlation of visual performance with quality of life and intraocular Aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.","volume":"28","author":"ML Ram\u00f3n","year":"2012","journal-title":"J Refract Surg"},{"key":"pone.0305076.ref023","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software \u201cEZR\u201d for medical statistics","volume":"48","author":"Y. Kanda","year":"2013","journal-title":"Bone Marrow Transplant"},{"key":"pone.0305076.ref024","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","article-title":"Development of the SRK\/T intraocular lens implant power calculation formula","volume":"16","author":"JA Retzlaff","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref025","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1016\/j.jcrs.2008.12.035","article-title":"Intraocular lens calculation in extreme myopia.","volume":"35","author":"W. Haigis","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref026","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.jcrs.2012.11.019","article-title":"Anterior chamber depth, intraocular lens position, and refractive outcomes after cataract surgery","volume":"39","author":"AL Engren","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref027","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1016\/j.jcrs.2004.02.072","article-title":"Influence of intraocular lens tilt and decentration on wavefront aberrations.","volume":"30","author":"F Taketani","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref028","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1136\/bjo.2006.099945","article-title":"Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration","volume":"91","author":"T Oshika","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"pone.0305076.ref029","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.jcrs.2018.10.045","article-title":"Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens.","volume":"45","author":"XM Liu","year":"2019","journal-title":"J Cataract Refract Surg"},{"issue":"Xv","key":"pone.0305076.ref030","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1097\/j.jcrs.0000000000000088","article-title":"Visual outcome and optical quality after implantation of zonal refractive multifocal and extended-range-of-vision IOLs: A prospective comparison.","volume":"46","author":"XH Song","year":"2020","journal-title":"J Cataract Refr Surg."},{"key":"pone.0305076.ref031","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1097\/OPX.0000000000000893","article-title":"The effects of age, refractive status, and luminance on pupil size.","volume":"93","author":"M Guillon","year":"2016","journal-title":"Optom Vis Sci"},{"key":"pone.0305076.ref032","doi-asserted-by":"crossref","first-page":"3274","DOI":"10.1364\/JOSAA.24.003274","article-title":"Mechanism of compensation of aberrations in the human eye","volume":"24","author":"J Tabernero","year":"2007","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"pone.0305076.ref033","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1016\/j.jcrs.2017.05.028","article-title":"Variability in angle kappa and its influence on higher-order aberrations in pseudophakic eyes.","volume":"43","author":"A Harrer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref034","first-page":"241","article-title":"Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.","volume":"10","author":"H Tchah","year":"2017","journal-title":"Int J Ophthalmol"},{"issue":"Suppl 1","key":"pone.0305076.ref035","doi-asserted-by":"crossref","first-page":"S102","DOI":"10.1097\/IJG.0000000000000925","article-title":"Exfoliation syndrome and cataract surgery","volume":"27","author":"AS Crandall","year":"2018","journal-title":"J Glaucoma"},{"key":"pone.0305076.ref036","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/j.jcrs.0000000000001069","article-title":"Cataract surgery in patients with underlying keratoconus: focused review","volume":"49","author":"R Gonzalez-Salinas","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"pone.0305076.ref037","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1080\/02713683.2020.1849727","article-title":"Share. Macular corneal dystrophy: An updated review","volume":"46","author":"S Singh","year":"2021","journal-title":"Curr Eye Res"},{"key":"pone.0305076.ref038","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1007\/s40123-022-00637-1","article-title":"Fuchs dystrophy and cataract: Diagnosis, evaluation and treatment.","volume":"12","author":"M Ali","year":"2023","journal-title":"Ophthalmol Ther"},{"key":"pone.0305076.ref039","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0002-9394(14)70169-2","article-title":"Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation","volume":"123","author":"K Hayashi","year":"1997","journal-title":"Am J Ophthalmol"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0305076","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T17:32:14Z","timestamp":1718040734000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0305076"}},"subtitle":[],"editor":[{"given":"Deepak","family":"Shukla","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2024,6,10]]},"references-count":39,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,6,10]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0305076","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,10]]}}}