{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:09:07Z","timestamp":1740146947663,"version":"3.37.3"},"reference-count":43,"publisher":"Public Library of Science (PLoS)","issue":"7","license":[{"start":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T00:00:00Z","timestamp":1721347200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005632","name":"Narodowe Centrum Bada\u0144 i Rozwoju","doi-asserted-by":"publisher","award":["LIDER\/15\/0061\/L-9\/17\/NCBR\/2018"],"award-info":[{"award-number":["LIDER\/15\/0061\/L-9\/17\/NCBR\/2018"]}],"id":[{"id":"10.13039\/501100005632","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004421","name":"Politechnika Warszawska","doi-asserted-by":"publisher","award":["Fotech2"],"award-info":[{"award-number":["Fotech2"]}],"id":[{"id":"10.13039\/501100004421","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"abstract":"<jats:p>Nowadays many patients are choosing EDOF or multifocal lenses for replacement of natural lens in cataract surgery. This can result in issues such as presence of dysphotopsias, namely halo and glare. In this work, we propose a new perimetry method to describe dysphotopsias in far-field region in a presence of bright, point-like light source. We constructed a custom device and designed measurement procedure for quantitative measurement of dysphotopias in the center of visual field and used it to examine patients with mild cataracts or implanted IOLs. Our approach may help in establishing an objective method to study and compare dysphotopsias.<\/jats:p>","DOI":"10.1371\/journal.pone.0306331","type":"journal-article","created":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T17:23:05Z","timestamp":1721409785000},"page":"e0306331","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Use of the perceptual point-spread function to assess dysphotopsias"],"prefix":"10.1371","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0138-1613","authenticated-orcid":true,"given":"Krzysztof","family":"Petelczyc","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Bolek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2789-0931","authenticated-orcid":true,"given":"Karol","family":"Kakarenko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8493-7762","authenticated-orcid":true,"given":"Karolina","family":"Krix-Jachym","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrzej","family":"Ko\u0142odziejczyk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0429-6649","authenticated-orcid":true,"given":"Marek","family":"R\u0119kas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2024,7,19]]},"reference":[{"issue":"2","key":"pone.0306331.ref001","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1177\/03611981211037891","article-title":"Identifying patterns of key factors in sun glare- related traffic crashes","volume":"2676","author":"S Das","year":"2022","journal-title":"Transp. Res. Rec"},{"issue":"11","key":"pone.0306331.ref002","doi-asserted-by":"crossref","first-page":"e195","DOI":"10.1016\/j.ophtha.2020.08.009","article-title":"Pseudophakic dysphotopsia: review of incidence, cause, and treatment of positive and negative dysphotopsia","volume":"128","author":"S Masket","year":"2021","journal-title":"Ophthalmology"},{"issue":"1","key":"pone.0306331.ref003","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/ICU.0000000000000447","article-title":"Dysphotopsia: a multifaceted optic phenomenon","volume":"29","author":"J Hu","year":"2018","journal-title":"Curr. Opin Ophthalmol"},{"issue":"6","key":"pone.0306331.ref004","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/S0886-3350(00)00427-2","article-title":"Dysphotopsia in phakic and pseudophakic patients: incidence and relation to intraocular lens type","volume":"26","author":"R Tester","year":"2000","journal-title":"J. Cataract Refract. Surg"},{"issue":"10","key":"pone.0306331.ref005","doi-asserted-by":"crossref","first-page":"1878","DOI":"10.1016\/S0161-6420(99)90396-2","article-title":"Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation","volume":"106","author":"HB Dick","year":"1999","journal-title":"Ophthalmology"},{"issue":"1","key":"pone.0306331.ref006","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1080\/02713683.2017.1379541","article-title":"Patient-perceived and laboratory-measured halos associated with diffractive bifocal and trifocal intraocular lenses","volume":"43","author":"F Alba-Bueno","year":"2018","journal-title":"Curr. Eye Res"},{"issue":"5","key":"pone.0306331.ref007","doi-asserted-by":"crossref","first-page":"2902","DOI":"10.1364\/BOE.424715","article-title":"Visual performance after the deterioration of retinal image quality: induced forward scattering using Bangerter foils and fog filters","volume":"12","author":"JJ Castro-Torres","year":"2021","journal-title":"Biomed. Opt. Express"},{"issue":"3","key":"pone.0306331.ref008","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000000061","article-title":"Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results","volume":"46","author":"R Mencucci","year":"2020","journal-title":"J. Cataract Refract. Surg"},{"issue":"7","key":"pone.0306331.ref009","doi-asserted-by":"crossref","first-page":"434","DOI":"10.3928\/1081597X-20190618-01","article-title":"Visual outcomes and patient satisfaction for trifocal, extended depth of focus and monofocal intraocular lenses","volume":"35","author":"L Rodov","year":"2019","journal-title":"J. Refract. Surg"},{"issue":"4","key":"pone.0306331.ref010","first-page":"339","article-title":"Multifocal intraocular lenses and extended depth of focus intraocular lenses","volume":"6","author":"DH Breyer","year":"2017","journal-title":"Asia Pac. J. Ophthalmol. (Phila)"},{"issue":"1","key":"pone.0306331.ref011","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1364\/BOE.11.000040","article-title":"Model of the light sword intraocular lens: in-vitro comparative studies","volume":"11","author":"K Petelczyc","year":"2020","journal-title":"Biomed. Opt. Express"},{"issue":"2","key":"pone.0306331.ref012","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s10792-019-01186-6","article-title":"Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses","volume":"40","author":"C Palomino-Bautista","year":"2020","journal-title":"Int. Ophthalmol"},{"issue":"6","key":"pone.0306331.ref013","doi-asserted-by":"crossref","first-page":"3967","DOI":"10.1167\/iovs.15-16600","article-title":"Halo and through-focus performance of four diffractive multifocal intraocular lenses","volume":"56","author":"F Vega","year":"2015","journal-title":"Invest. Ophthalmol. Vis. Sci"},{"key":"pone.0306331.ref014","doi-asserted-by":"crossref","first-page":"385","DOI":"10.2147\/OPTH.S152201","article-title":"Comparison of two laboratory-based systems for evaluation of halos in intraocular lenses","volume":"12","author":"D Carson","year":"2018","journal-title":"Clin. Ophthalmol"},{"issue":"12","key":"pone.0306331.ref015","doi-asserted-by":"crossref","first-page":"3123","DOI":"10.1364\/JOSAA.11.003123","article-title":"Double-pass and interferometric measures of the optical quality of the eye","volume":"11","author":"DR Williams","year":"1994","journal-title":"JOSA A"},{"issue":"9","key":"pone.0306331.ref016","doi-asserted-by":"crossref","first-page":"3036","DOI":"10.1364\/BOE.5.003036","article-title":"Compact optical integration instrument to measure intraocular straylight","volume":"5","author":"H Ginis","year":"2014","journal-title":"Biomed. Opt. Ex"},{"issue":"4","key":"pone.0306331.ref017","doi-asserted-by":"crossref","first-page":"228","DOI":"10.3928\/1081597X-20180125-01","article-title":"Visual performance of a new extended depth-of-focus intraocular lens compared to a distance-dominant diffractive multifocal intraocular lens","volume":"34","author":"G Savini","year":"2018","journal-title":"J. Refract. Surg"},{"issue":"2","key":"pone.0306331.ref018","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1109\/TVCG.2020.3029413","article-title":"A design space of vision science methods for visualization research","volume":"27","author":"MA Elliott","year":"2021","journal-title":"IEEE Trans. Vis. Comput. Graph"},{"key":"pone.0306331.ref019","doi-asserted-by":"crossref","first-page":"910620","DOI":"10.3389\/fnhum.2022.910620","article-title":"Does intraocular straylight predict night driving visual performance? Correlations between straylight levels and contrast sensitivity, halo size, and hazard recognition distance with and without glare","volume":"16","author":"J Ungewiss","year":"2022","journal-title":"Front. Hum. Neurosci"},{"issue":"9","key":"pone.0306331.ref020","doi-asserted-by":"crossref","first-page":"618","DOI":"10.3928\/1081597X-20130819-03","article-title":"Normal values for the size of a halo produced by a glare source","volume":"29","author":"MC Puell","year":"2013","journal-title":"J. Refract. Surg"},{"issue":"10","key":"pone.0306331.ref021","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1016\/j.jcrs.2015.10.047","article-title":"Capacity of straylight and disk halo size to diagnose cataract","volume":"41","author":"C Palomo-\u00c1lvarez","year":"2015","journal-title":"J. Cataract. Refract. Surg"},{"issue":"1","key":"pone.0306331.ref022","doi-asserted-by":"crossref","first-page":"E8","DOI":"10.1097\/OPX.0b013e3182004c3b","article-title":"A history of perimetry and visual field testing","volume":"88","author":"CA Johnson","year":"2011","journal-title":"Optom. Vis. Sci"},{"key":"pone.0306331.ref023","unstructured":"Hoya Surgical Optics, \u201ciSert Specs Sheet\u201d, https:\/\/www.hoyasurgicaloptics.com\/isert\/iol."},{"key":"pone.0306331.ref024","unstructured":"MyAlconProfessionals, \u201cAcrySof\u00ae IQ Monofocal and AcrySof\u00ae IQ Toric IOLs,\u201d https:\/\/www.myalcon.com\/uk\/professional\/cataract-surgery\/iols\/acrysof-iq-monofocal\/."},{"key":"pone.0306331.ref025","unstructured":"Rayner, \u201cExtending range without compromise\u201d, https:\/\/rayner.com\/en\/iol\/rayone-emv\/."},{"key":"pone.0306331.ref026","unstructured":"MyAlconProfessionals, \u201cAcrySof IQ Vivity\u00ae IOL,\u201d https:\/\/www.myalcon.com\/international\/professional\/cataract-surgery\/iols\/vivity\/."},{"key":"pone.0306331.ref027","unstructured":"TECNIS Symfony\u00ae Extended Range of Vision IOL, Product Leaflet Z311215 Rev. 01."},{"issue":"1","key":"pone.0306331.ref028","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1073\/pnas.38.1.80","article-title":"Spectral sensitivity of the cones in the dark adapted human eye","volume":"38","author":"Y. Hsia","year":"1952","journal-title":"Proc Natl Acad Sci U S A"},{"key":"pone.0306331.ref029","article-title":"Psychophysics","author":"FAA Kingdom","year":"2010","journal-title":"A Practical Introduction (Elsevier Ltd."},{"issue":"4","key":"pone.0306331.ref030","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1037\/h0039821","article-title":"The derivation of subjective scales from just noticeable differences","volume":"65","author":"RD Luce","year":"1958","journal-title":"Psychol. Rev"},{"issue":"16","key":"pone.0306331.ref031","doi-asserted-by":"crossref","first-page":"2729","DOI":"10.1016\/S0042-6989(98)00285-5","article-title":"Bayesian adaptive estimation of psychometric slope and threshold","volume":"39","author":"LL Kontsevich","year":"1999","journal-title":"Vision Res"},{"issue":"11","key":"pone.0306331.ref032","doi-asserted-by":"crossref","first-page":"e164","DOI":"10.1016\/j.ophtha.2020.09.026","article-title":"Multifocal and extended depth-of-focus intraocular lenses in 2020","volume":"128","author":"R Rampat","year":"2021","journal-title":"Ophthalmology"},{"issue":"7","key":"pone.0306331.ref033","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1080\/02713683.2023.2192446","article-title":"The Effects of Blue-Light Filtering Intraocular Implants on Glare Geometry","volume":"48","author":"B. R. Hammond","year":"2023","journal-title":"Curr. Eye Res"},{"issue":"1","key":"pone.0306331.ref034","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.jcrs.2010.07.034","article-title":"Reduced effect of glare disability on driving performance in patients with blue light\u2013filtering intraocular lenses","volume":"37","author":"R. Gray","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0306331.ref035","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1016\/j.jcrs.2011.11.047","article-title":"Effects of a blue light\u2013filtering intraocular lens on driving safety in glare conditions","volume":"38","author":"R. Gray","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"pone.0306331.ref036","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1140\/epjp\/s13360-022-03045-3","article-title":"Suitability of blue light filters for eye care","volume":"137","author":"D. Baeza-Moyano","year":"2022","journal-title":"Eur. Phys. J. Plus"},{"key":"pone.0306331.ref037","doi-asserted-by":"crossref","first-page":"110577","DOI":"10.1016\/j.biopha.2020.110577","article-title":"Mechanisms of blue light-induced eye hazard and protective measures: a review","volume":"130","author":"X. I. N. L. I. Ouyang","year":"2020","journal-title":"Biomed Pharmacother"},{"issue":"6","key":"pone.0306331.ref038","doi-asserted-by":"crossref","first-page":"559","DOI":"10.3390\/medicina57060559","article-title":"Effect of blue light filtering intraocular lenses on visual perception","volume":"57","author":"I. Popov","year":"2021","journal-title":"Medicina"},{"key":"pone.0306331.ref039","doi-asserted-by":"crossref","first-page":"203","DOI":"10.3389\/fncel.2018.00203","article-title":"The roles of rods, cones, and melanopsin in photoresponses of M4 intrinsically photosensitive retinal ganglion cells (ipRGCs) and optokinetic visual behavior","volume":"12","author":"M. M. Schroeder","year":"2018","journal-title":"Front. Cell. Neurosci."},{"issue":"3","key":"pone.0306331.ref040","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1167\/12.3.20","article-title":"The wide-angle point spread function of the human eye reconstructed by a new optical method","volume":"12","author":"H Ginis","year":"2012","journal-title":"J. Vis"},{"issue":"2","key":"pone.0306331.ref041","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1167\/15.2.26","article-title":"Computing human optical point spread functions","volume":"15","author":"AB Watson","year":"2015","journal-title":"J. Vis"},{"key":"pone.0306331.ref042","doi-asserted-by":"crossref","unstructured":"van den Berg TJTP. The (lack of) relation between straylight and visual acuity. Two domains of the point\u2010spread\u2010function. Ophthalmic Physiol Opt. 2017;37(3):333\u2013341. doi: 10.1111\/opo.12368","DOI":"10.1111\/opo.12368"},{"issue":"11","key":"pone.0306331.ref043","doi-asserted-by":"crossref","first-page":"2417","DOI":"10.1016\/j.jcrs.2015.04.030","article-title":"Disk halo size measured in individuals with monofocal versus diffractive multifocal intraocular lenses","volume":"41","author":"MC Puell","year":"2015","journal-title":"J. Cataract. Refract. Surg"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0306331","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T17:23:35Z","timestamp":1721409815000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0306331"}},"subtitle":[],"editor":[{"given":"Manuel","family":"Spitschan","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2024,7,19]]},"references-count":43,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,7,19]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0306331","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2024,7,19]]}}}