{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T18:10:03Z","timestamp":1750788603003,"version":"3.41.0"},"reference-count":36,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T00:00:00Z","timestamp":1750723200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Institute of Health","award":["R03CA223052"],"award-info":[{"award-number":["R03CA223052"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec id=\"sec001\">\n<jats:title>Purpose<\/jats:title>\n<jats:p>Breast density (BD) is a significant risk factor for breast cancer, yet current assessment methods lack automation, quantification, and cross-platform consistency. This study aims to evaluate the reliability and cross-platform consistency of MagDensity, a novel magnetic resonance imaging (MRI)-based quantitative BD measure, across different imaging platforms.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec002\">\n<jats:title>Methods<\/jats:title>\n<jats:p>Ten healthy volunteers participated in this prospective study, undergoing fat-water MRI scans on three scanners: 3T Siemens Prisma, 3T Siemens Biograph mMR, and 1.5T GE Signa. Great effort was made to schedule all scans within a narrow three-hour window on the same day to minimize any potential intra- or inter-day variations, requiring substantial logistical coordination. BD was assessed using the MagDensity technique, which included combining magnitude and phase images, applying a fat-water separation technique, employing an automated whole-breast segmentation algorithm, and quantifying the volumetric water fraction. Agreement between measures across scanners was analyzed using mean differences, two-tailed t-tests, Pearson\u2019s correlation, and Bland-Altman analysis.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec003\">\n<jats:title>Results<\/jats:title>\n<jats:p>MagDensity measures obtained from the two 3T Siemens scanners demonstrated no statistically significant differences, with high correlation (Pearson\u2019s r\u2009&gt;\u20090.99) and negligible mean differences (&lt; 0.2%). Cross-platform comparison between the 3T Siemens and the 1.5T GE scanners showed larger mean differences (&lt; 4.2%). However, after applying linear calibration, these variations were reduced to within \u00b10.2%, with strong inter-scanner correlation maintained (Pearson\u2019s r\u2009&gt;\u20090.97).<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sec004\">\n<jats:title>Conclusion<\/jats:title>\n<jats:p>MagDensity showed strong intra-vendor consistency and promising cross-platform reliability after leave-one-out calibration. While full standardization remains a long-term goal, these findings provide clear evidence that scanner-related variability can be effectively mitigated through calibration. This technique offers a step further toward more consistent MRI-based BD quantification and may help enable broader clinical implementation.<\/jats:p>\n<\/jats:sec>","DOI":"10.1371\/journal.pone.0316076","type":"journal-article","created":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T17:29:44Z","timestamp":1750786184000},"page":"e0316076","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cross-field strength and multi-vendor reliability of MagDensity for MRI-based quantitative breast density analysis"],"prefix":"10.1371","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7846-2588","authenticated-orcid":true,"given":"Jia","family":"Ying","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Renee","family":"Cattell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6052-0663","authenticated-orcid":true,"given":"Chuan","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2025,6,24]]},"reference":[{"issue":"6","key":"pone.0316076.ref001","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1158\/1055-9965.EPI-06-0034","article-title":"Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis","volume":"15","author":"VA McCormack","year":"2006","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"issue":"6","key":"pone.0316076.ref002","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1186\/bcr2942","article-title":"Mammographic density and breast cancer risk: current understanding and future prospects","volume":"13","author":"NF Boyd","year":"2011","journal-title":"Breast Cancer Res"},{"issue":"1","key":"pone.0316076.ref003","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s13058-017-0887-5","article-title":"Combining quantitative and qualitative breast density measures to assess breast cancer risk","volume":"19","author":"K Kerlikowske","year":"2017","journal-title":"Breast Cancer Res"},{"issue":"28","key":"pone.0316076.ref004","doi-asserted-by":"crossref","first-page":"3137","DOI":"10.1200\/JCO.2015.60.8869","article-title":"Breast density and benign breast disease: risk assessment to identify women at high risk of breast cancer","volume":"33","author":"JA Tice","year":"2015","journal-title":"J Clin Oncol"},{"issue":"2","key":"pone.0316076.ref005","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1093\/jbi\/wbz006","article-title":"A case-control study to add volumetric or clinical mammographic density into the Tyrer-Cuzick breast cancer risk model","volume":"1","author":"AR Brentnall","year":"2019","journal-title":"J Breast Imaging"},{"issue":"5","key":"pone.0316076.ref006","doi-asserted-by":"crossref","first-page":"337","DOI":"10.7326\/0003-4819-148-5-200803040-00004","article-title":"Using clinical factors and mammographic breast density to estimate breast cancer risk: development and validation of a new predictive model","volume":"148","author":"JA Tice","year":"2008","journal-title":"Ann Intern Med"},{"issue":"8","key":"pone.0316076.ref007","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1038\/s41436-018-0406-9","article-title":"BOADICEA: a comprehensive breast cancer risk prediction model incorporating genetic and nongenetic risk factors","volume":"21","author":"A Lee","year":"2019","journal-title":"Genet Med"},{"key":"pone.0316076.ref008","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacr.2016.09.027","article-title":"Dense breast legislation in the United States: state of the states","volume":"13","author":"SF Dehkordy","year":"2016","journal-title":"J Am Coll Radiol"},{"issue":"4","key":"pone.0316076.ref009","first-page":"725","article-title":"Risk-based breast cancer screening: implications of breast density","volume":"101","author":"CI Lee","year":"2017","journal-title":"Med Clin"},{"issue":"6","key":"pone.0316076.ref010","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1158\/1055-9965.EPI-16-0882","article-title":"Longitudinal changes in volumetric breast density with tamoxifen and aromatase inhibitors","volume":"26","author":"NJ Engmann","year":"2017","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"issue":"4","key":"pone.0316076.ref011","doi-asserted-by":"crossref","DOI":"10.1093\/jncics\/pky071","article-title":"Adjuvant therapy and mammographic density changes in women with breast cancer","volume":"2","author":"L Eriksson","year":"2019","journal-title":"JNCI Cancer Spectr"},{"issue":"9","key":"pone.0316076.ref012","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1093\/jnci\/djr079","article-title":"Tamoxifen-induced reduction in mammographic density and breast cancer risk reduction: a nested case-control study","volume":"103","author":"J Cuzick","year":"2011","journal-title":"J Natl Cancer Inst"},{"issue":"7","key":"pone.0316076.ref013","doi-asserted-by":"crossref","first-page":"457","DOI":"10.7326\/M15-2934","article-title":"Variation in mammographic breast density assessments among radiologists in clinical practice: a multicenter observational study","volume":"165","author":"BL Sprague","year":"2016","journal-title":"Ann Intern Med"},{"key":"pone.0316076.ref014","article-title":"ACR BI-RADS\u00ae magnetic resonance imaging","volume-title":"ACR BI-RADS\u00ae Atlas, Breast Imaging Reporting and Data System","author":"E Morris","year":"2013"},{"issue":"7","key":"pone.0316076.ref015","doi-asserted-by":"crossref","first-page":"3579","DOI":"10.1002\/mp.12279","article-title":"Breast-density measurement using photon-counting spectral mammography","volume":"44","author":"H Johansson","year":"2017","journal-title":"Med Phys"},{"issue":"1","key":"pone.0316076.ref016","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1148\/radiol.2019190425","article-title":"Digital mammography versus breast tomosynthesis: impact of breast density on diagnostic performance in population-based screening","volume":"293","author":"BH \u00d8ster\u00e5s","year":"2019","journal-title":"Radiology"},{"issue":"4","key":"pone.0316076.ref017","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1002\/jmri.26041","article-title":"Reproducible automated breast density measure with no ionizing radiation using fat-water decomposition MRI","volume":"48","author":"J Ding","year":"2018","journal-title":"J Magn Reson Imaging"},{"issue":"20","key":"pone.0316076.ref018","doi-asserted-by":"crossref","first-page":"5660","DOI":"10.1158\/1078-0432.CCR-21-0732","article-title":"Sulindac, a nonselective NSAID, reduces breast density in postmenopausal women with breast cancer treated with aromatase inhibitors","volume":"27","author":"PA Thompson","year":"2021","journal-title":"Clin Cancer Res"},{"issue":"1","key":"pone.0316076.ref019","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/s10549-021-06355-9","article-title":"A randomized controlled trial of metformin in women with components of metabolic syndrome: intervention feasibility and effects on adiposity and breast density","volume":"190","author":"E Tapia","year":"2021","journal-title":"Breast Cancer Res Treat"},{"key":"pone.0316076.ref020","volume-title":"MR-derived breast density (MagDensity) enables reliable density measures across field strengths and vendors","author":"J Ying","year":"2023"},{"issue":"1","key":"pone.0316076.ref021","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00266-018-1243-6","article-title":"Menstrual cycle-related fluctuations in breast volume measured using three-dimensional imaging: implications for volumetric evaluation in breast augmentation","volume":"43","author":"C Wang","year":"2019","journal-title":"Aesthetic Plast Surg"},{"issue":"3","key":"pone.0316076.ref022","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1002\/jmri.20831","article-title":"Water-fat separation with IDEAL gradient-echo imaging","volume":"25","author":"SB Reeder","year":"2007","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"pone.0316076.ref023","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s42492-022-00121-4","article-title":"Two fully automated data-driven 3D whole-breast segmentation strategies in MRI for MR-based breast density using image registration and U-Net with a focus on reproducibility","volume":"5","author":"J Ying","year":"2022","journal-title":"Vis Comput Ind Biomed Art"},{"key":"pone.0316076.ref024","volume-title":"Registration-based whole breast segmentation enables highly reproducible quantitative MR-based breast density","author":"J Ying","year":"2021"},{"key":"pone.0316076.ref025","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.clinimag.2021.11.034","article-title":"Persistent inter-observer variability of breast density assessment using BI-RADS\u00ae 5th edition guidelines","volume":"83","author":"LH Portnow","year":"2022","journal-title":"Clin Imaging"},{"key":"pone.0316076.ref026","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/978-3-031-10898-3_5","article-title":"Mammographic density","volume-title":"Digital mammography: a holistic approach","author":"EF Harkness","year":"2022"},{"key":"pone.0316076.ref027","volume-title":"Understanding Quantra 2.0 user manual-man-02004 rev 002","author":"H Inc","year":"2012"},{"key":"pone.0316076.ref028","unstructured":"Highnam R, Brady SM, Yaffe MJ, Karssemeijer N, Harvey J. Robust breast composition measurement-Volpara TM. In: Digital Mammography: 10th International Workshop, IWDM 2010, Girona, Catalonia, Spain, June 16-18, 2010 Proceedings. 2010."},{"issue":"1","key":"pone.0316076.ref029","doi-asserted-by":"crossref","first-page":"18760","DOI":"10.1038\/s41598-023-45402-x","article-title":"Breast density analysis of digital breast tomosynthesis","volume":"13","author":"J Heine","year":"2023","journal-title":"Sci Rep"},{"issue":"12","key":"pone.0316076.ref030","article-title":"Agreement of mammographic measures of volumetric breast density to MRI","volume":"8","author":"J Wang","year":"2013","journal-title":"PLoS One"},{"issue":"1","key":"pone.0316076.ref031","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1118\/1.3271346","article-title":"Quantitative analysis of breast parenchymal patterns using 3D fibroglandular tissues segmented based on MRI","volume":"37","author":"K Nie","year":"2010","journal-title":"Med Phys"},{"issue":"7","key":"pone.0316076.ref032","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.crad.2017.02.014","article-title":"Breast fat volume measurement using wide-bore 3 T MRI: comparison of traditional mammographic density evaluation with MRI density measurements using automatic segmentation","volume":"72","author":"E Petridou","year":"2017","journal-title":"Clinical Radiol"},{"issue":"2","key":"pone.0316076.ref033","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/RLI.0000000000000102","article-title":"Introduction of an automated user\u2013independent quantitative volumetric magnetic resonance imaging breast density measurement system using the Dixon sequence: comparison with mammographic breast density assessment","volume":"50","author":"GJ Wengert","year":"2015","journal-title":"Invest Radiol"},{"issue":"6","key":"pone.0316076.ref034","doi-asserted-by":"crossref","DOI":"10.1002\/nbm.3705","article-title":"Accuracy of fully automated, quantitative, volumetric measurement of the amount of fibroglandular breast tissue using MRI: correlation with anthropomorphic breast phantoms","volume":"30","author":"GJ Wengert","year":"2017","journal-title":"NMR Biomed"},{"key":"pone.0316076.ref035","unstructured":"Man YD, Yu T. The epidemiologic factors associated with breast density: a review. 2022."},{"issue":"1","key":"pone.0316076.ref036","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/s13058-024-01890-x","article-title":"Reproductive factors and mammographic density within the International Consortium of Mammographic Density: a cross-sectional study","volume":"26","author":"J O\u2019Driscoll","year":"2024","journal-title":"Breast Cancer Res"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0316076","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T17:29:53Z","timestamp":1750786193000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0316076"}},"subtitle":[],"editor":[{"given":"Peter","family":"Lundberg","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2025,6,24]]},"references-count":36,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,6,24]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0316076","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,24]]}}}