{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T11:44:55Z","timestamp":1769168695508,"version":"3.49.0"},"reference-count":35,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T00:00:00Z","timestamp":1747267200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>We compared the visual performance of a monofocal intraocular lens (IOL) (ZCB00) and a rotationally asymmetric refractive IOL with +1.5 diopters near addition (Lentis Comfort LS-313 MF15) by investigating the ten-week postoperative parameters of both eyes of cataract patients who underwent bilateral implantation with one of the two IOLs within three months between 2011 and 2019. A total of 1352 eyes of 676 patients were enrolled; the ZCB00 group comprised 904 eyes of 452 patients (72.3\u2009\u00b1\u20096.8 years; females\/males, 268\/184), and the LS-313 MF15 group included 448 eyes of 224 patients (73.6\u2009\u00b1\u20097.0 years; females\/males, 125\/99). Comparisons were made with a linear mixed-effects model, strictly adjusting for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter to ensure statistical validity. The corrected distance visual acuity was significantly better, and most of the higher-order aberrations were significantly smaller in the ZCB00 group (p\u2009&lt;\u20090.00068, Wald test). Contrast sensitivity with glare (6.3\u2009degrees) and spectacle independence (near) were significantly better in the LS-313 MF15 group (p\u2009&lt;\u20090.00068, Wald test).<\/jats:p>","DOI":"10.1371\/journal.pone.0323625","type":"journal-article","created":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T17:42:45Z","timestamp":1747330965000},"page":"e0323625","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of visual performance between monofocal and rotationally asymmetric refractive intraocular lenses"],"prefix":"10.1371","volume":"20","author":[{"given":"Masaki","family":"Miyoshi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1948-7408","authenticated-orcid":true,"given":"Hirotaka","family":"Tanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Shojo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomofusa","family":"Yamauchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kosuke","family":"Takase","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hitoshi","family":"Tabuchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2025,5,15]]},"reference":[{"issue":"3","key":"pone.0323625.ref001","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.ajo.2007.05.036","article-title":"Visual performance of patients with bilateral vs combination Crystalens, ReZoom, and ReSTOR intraocular lens implants","volume":"144","author":"JS Pepose","year":"2007","journal-title":"Am J Ophthalmol"},{"issue":"6","key":"pone.0323625.ref002","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.jcrs.2007.02.037","article-title":"Functional outcomes after implantation of Tecnis ZM900 and Array SA40 multifocal intraocular lenses","volume":"33","author":"U Mester","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"pone.0323625.ref003","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.ajo.2009.10.022","article-title":"Evaluation of the aspheric tecnis multifocal intraocular lens: one-year results from the first cohort of the food and drug administration clinical trial","volume":"149","author":"M Packer","year":"2010","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"pone.0323625.ref004","first-page":"257","article-title":"Visual function with bilateral implantation of monofocal and multifocal intraocular lenses: a prospective, randomized, controlled clinical trial","volume":"24","author":"A Mart\u00ednez Palmer","year":"2008","journal-title":"J Refract Surg"},{"issue":"9","key":"pone.0323625.ref005","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/S0161-6420(03)00722-X","article-title":"Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review","volume":"110","author":"M Leyland","year":"2003","journal-title":"Ophthalmology"},{"issue":"6","key":"pone.0323625.ref006","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.jcrs.2009.01.031","article-title":"Dissatisfaction after multifocal intraocular lens implantation","volume":"35","author":"MA Woodward","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"pone.0323625.ref007","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/S0886-3350(02)01648-6","article-title":"Distance and near contrast sensitivity function after multifocal intraocular lens implantation","volume":"29","author":"R Mont\u00e9s-Mic\u00f3","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"pone.0323625.ref008","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1136\/bjo.85.7.816","article-title":"Halo size under distance and near conditions in refractive multifocal intraocular lenses","volume":"85","author":"S Pieh","year":"2001","journal-title":"Br J Ophthalmol"},{"issue":"7","key":"pone.0323625.ref009","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/S0161-6420(99)00704-6","article-title":"A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens","volume":"106","author":"RF Steinert","year":"1999","journal-title":"Ophthalmology"},{"key":"pone.0323625.ref010","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.jcrs.2017.01.024","article-title":"Bifocal nondiffractive intraocular lens for enhanced depth of focus in correcting presbyopia: clinical evaluation","volume":"43","author":"E Vounotrypidis","year":"2017","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0323625.ref011","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1272\/jnms.JNMS.2021_88-504","article-title":"Clinical Outcome of Lentis Comfort Intraocular Lens Implantation","volume":"88","author":"D Nakajima","year":"2021","journal-title":"J Nippon Med Sch"},{"key":"pone.0323625.ref012","doi-asserted-by":"crossref","first-page":"37","DOI":"10.17116\/oftalma2017133137-41","article-title":"Clinical results of aphakia correction with multifocal intraocular lenses","volume":"133","author":"GV Voronin","year":"2017","journal-title":"Vestn Oftalmol"},{"issue":"1","key":"pone.0323625.ref013","doi-asserted-by":"crossref","first-page":"13117","DOI":"10.1038\/s41598-019-49524-z","article-title":"One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition","volume":"9","author":"T Oshika","year":"2019","journal-title":"Sci Rep"},{"issue":"2","key":"pone.0323625.ref014","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jcrs.2006.10.035","article-title":"Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision","volume":"33","author":"A Denoyer","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0323625.ref015","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1016\/j.jcrs.2003.10.022","article-title":"Improved functional vision with a modified prolate intraocular lens","volume":"30","author":"M Packer","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"pone.0323625.ref016","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.jcrs.2004.08.049","article-title":"Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study","volume":"31","author":"R Bellucci","year":"2005","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0323625.ref017","doi-asserted-by":"crossref","first-page":"15490","DOI":"10.1038\/s41598-020-72473-x","article-title":"Comparison of visual performance between monofocal and multifocal intraocular lenses of the same material and basic design","volume":"10","author":"H Tanabe","year":"2020","journal-title":"Sci Rep"},{"issue":"1","key":"pone.0323625.ref018","doi-asserted-by":"crossref","first-page":"19394","DOI":"10.1038\/s41598-022-24123-7","article-title":"Comparative visual performance of diffractive bifocal and rotationally asymmetric refractive intraocular lenses","volume":"12","author":"H Tanabe","year":"2022","journal-title":"Sci Rep"},{"issue":"7","key":"pone.0323625.ref019","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0288602","article-title":"Comparison of visual performance between bifocal and extended-depth-of-focus intraocular lenses","volume":"18","author":"H Tabuchi","year":"2023","journal-title":"PLoS One"},{"issue":"1","key":"pone.0323625.ref020","doi-asserted-by":"crossref","first-page":"5292","DOI":"10.1038\/s41598-024-55926-5","article-title":"Comparison of visual performance between diffractive bifocal and diffractive trifocal intraocular lenses","volume":"14","author":"J Kawamura","year":"2024","journal-title":"Sci Rep"},{"key":"pone.0323625.ref021","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1186\/1477-7525-3-65","article-title":"Psychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version","volume":"3","author":"Y Suzukamo","year":"2005","journal-title":"Health Qual Life Outcomes"},{"key":"pone.0323625.ref022","volume-title":"R: a language and environment for statistical computing","author":"R Core Team","year":"2019"},{"issue":"5","key":"pone.0323625.ref023","doi-asserted-by":"crossref","first-page":"492","DOI":"10.3928\/1081-597X-20070501-13","article-title":"Takagi Glare Tester CGT-1000 for contrast sensitivity and glare testing in normal individuals and cataract patients","volume":"23","author":"K Pesudovs","year":"2007","journal-title":"J Refract Surg"},{"issue":"6","key":"pone.0323625.ref024","first-page":"331","article-title":"A new device for measuring contrast sensitivity with and without glare","volume":"78","author":"C S\u00e1nchez-Ramos","year":"2003","journal-title":"Arch Soc Esp Oftalmol"},{"issue":"4","key":"pone.0323625.ref025","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/OPX.0000000000001495","article-title":"On the Chromatic Dispersion of Hydrophobic and Hydrophilic Intraocular Lenses","volume":"97","author":"T Eppig","year":"2020","journal-title":"Optom Vis Sci"},{"key":"pone.0323625.ref026","volume-title":"Fundamentals of visual optics","author":"H Uosato","year":"1990"},{"issue":"8","key":"pone.0323625.ref027","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1001\/archopht.119.8.1154","article-title":"Effect of chromatic aberration on contrast sensitivity in pseudophakic eyes","volume":"119","author":"K Negishi","year":"2001","journal-title":"Arch Ophthalmol"},{"issue":"9","key":"pone.0323625.ref028","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1136\/bjo.2007.118745","article-title":"The effect of chromatic dispersion on pseudophakic optical performance","volume":"91","author":"H Zhao","year":"2007","journal-title":"Br J Ophthalmol"},{"issue":"2","key":"pone.0323625.ref029","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1001\/archopht.116.2.227","article-title":"Identifying the content area for the 51-item National Eye Institute Visual Function Questionnaire: results from focus groups with visually impaired persons","volume":"116","author":"CM Mangione","year":"1998","journal-title":"Arch Ophthalmol"},{"key":"pone.0323625.ref030","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archopht.119.7.1050","article-title":"Development of the 25-item national eye institute visual function questionnaire","volume":"119","author":"CM Mangione","year":"2001","journal-title":"Arch Ophthalmol"},{"issue":"1","key":"pone.0323625.ref031","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1038\/s41598-017-19113-z","article-title":"Visual field loss and vision-related quality of life in the Italian Primary Open Angle Glaucoma Study","volume":"8","author":"E Rulli","year":"2018","journal-title":"Sci Rep"},{"issue":"1","key":"pone.0323625.ref032","doi-asserted-by":"crossref","first-page":"6735","DOI":"10.1038\/s41598-019-43203-9","article-title":"Vision-related quality of life and symptom perception change over time in newly-diagnosed primary open angle glaucoma patients","volume":"9","author":"I Riva","year":"2019","journal-title":"Sci Rep"},{"issue":"1","key":"pone.0323625.ref033","article-title":"Patient-reported outcome measures in the management of neovascular age-related macular degeneration: a 1-year prospective study","volume":"4","author":"E Jelin","year":"2019","journal-title":"BMJ Open Ophthalmol"},{"issue":"6","key":"pone.0323625.ref034","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s10384-019-00687-2","article-title":"Vision-related quality of life in Japanese patients with wet age-related macular degeneration treated with intravitreal aflibercept in a real-world setting","volume":"63","author":"F Gomi","year":"2019","journal-title":"Jpn J Ophthalmol"},{"key":"pone.0323625.ref035","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.survophthal.2018.08.003","article-title":"Methods for the study of near, intermediate vision, and accommodation: an overview of subjective and objective approaches","volume":"64","author":"V Vargas","year":"2019","journal-title":"Surv Ophthalmol"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0323625","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T17:42:54Z","timestamp":1747330974000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0323625"}},"subtitle":[],"editor":[{"given":"Timo","family":"Eppig","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2025,5,15]]},"references-count":35,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,5,15]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0323625","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,15]]}}}