{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T16:35:42Z","timestamp":1792600542952,"version":"4.5.0"},"reference-count":32,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T00:00:00Z","timestamp":1747872000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>Traditional methods for evaluating postoperative human motion in orthopedics suffer from high equipment costs, time-consuming detection processes, and can only provide static two-dimensional image information. To improve the efficiency and accuracy of postoperative human motion assessment in orthopedics, this study proposes an improved algorithm on the basis of kinematic constraints and inertial measurement units for postoperative human motion assessment in orthopedics. Compared with other methods, the average error and standard deviation of measuring human joint range of motion after orthopedic surgery based on inertial measurement units were the smallest. The average error and standard deviation of measuring human wrist joint range of motion were 1.23\u00b0 and 1.63\u00b0, respectively. The efficiency and accuracy of measuring human joint range of motion after orthopedic surgery based on inertial measurement units were the highest. The efficiency and accuracy were 4s and 98%, respectively. The accuracy of calculating the human joint Angle after orthopedic surgery based on kinematic constraints is also better than other traditional algorithms. The method has high accuracy and applicability, which can effectively improve the monitoring efficiency of postoperative human motion assessment in orthopedics, reduce the error of postoperative human motion assessment in orthopedics, and effectively support personalized management and intervention, further providing reference for the optimization of postoperative human motion assessment in orthopedics.<\/jats:p>","DOI":"10.1371\/journal.pone.0323821","type":"journal-article","created":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T17:41:49Z","timestamp":1747935709000},"page":"e0323821","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":2,"title":["Postoperative human motion evaluation in orthopedics based on kinematic constraints and improved IMU-generated data processing algorithm"],"prefix":"10.1371","volume":"20","author":[{"given":"Linzhi","family":"Xie","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9013-8860","authenticated-orcid":true,"given":"Zhengnan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2025,5,22]]},"reference":[{"issue":"3","key":"pone.0323821.ref001","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/s12282-022-01347-z","article-title":"Impact of exercise interventions on physical fitness in breast cancer patients and survivors: a systematic review","volume":"29","author":"S Ficarra","year":"2022","journal-title":"Breast Cancer"},{"issue":"6","key":"pone.0323821.ref002","doi-asserted-by":"crossref","first-page":"2922","DOI":"10.1007\/s00415-021-10935-6","article-title":"Fitness, physical activity, and exercise in multiple sclerosis: a systematic review on current evidence for interactions with disease activity and progression","volume":"269","author":"S Proschinger","year":"2022","journal-title":"J Neurol"},{"issue":"2","key":"pone.0323821.ref003","doi-asserted-by":"crossref","first-page":"98","DOI":"10.47852\/bonviewAIA3202441","article-title":"Evaluation of deep learning CNN model for recognition of Devanagari digit","volume":"1","author":"K Bhosle","year":"2023","journal-title":"AIA"},{"issue":"1","key":"pone.0323821.ref004","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s11916-023-01192-5","article-title":"Effectiveness of virtual reality-based rehabilitation interventions in improving postoperative outcomes for orthopedic surgery patients","volume":"28","author":"M Ehioghae","year":"2024","journal-title":"Curr Pain Headache Rep"},{"issue":"10","key":"pone.0323821.ref005","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1080\/14763141.2021.1945136","article-title":"Validity, reliability and accuracy of inertial measurement units (IMUs) to measure angles: application in swimming","volume":"23","author":"B Guignard","year":"2024","journal-title":"Sports Biomech"},{"issue":"3","key":"pone.0323821.ref006","doi-asserted-by":"crossref","first-page":"2693","DOI":"10.1109\/JSEN.2022.3229475","article-title":"An optimal fusion method of multiple inertial measurement units based on measurement noise variance estimation","volume":"23","author":"H Huang","year":"2023","journal-title":"IEEE Sensors J"},{"issue":"1","key":"pone.0323821.ref007","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1080\/10749357.2023.2197278","article-title":"Upper limb assessment with inertial measurement units according to the international classification of functioning in stroke: a systematic review and correlation meta-analysis","volume":"31","author":"A Martino Cinnera","year":"2024","journal-title":"Top Stroke Rehabil"},{"issue":"6","key":"pone.0323821.ref008","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1109\/MCS.2022.3209059","article-title":"Inertial measurement unit error modeling tutorial: Inertial navigation system state estimation with real-time sensor calibration","volume":"42","author":"JA Farrell","year":"2022","journal-title":"IEEE Control Syst"},{"issue":"2","key":"pone.0323821.ref009","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1007\/s10462-021-09979-x","article-title":"Pattern identification of different human joints for different human walking styles using inertial measurement unit (IMU) sensor","volume":"55","author":"VB Semwal","year":"2021","journal-title":"Artif Intell Rev"},{"issue":"20","key":"pone.0323821.ref010","doi-asserted-by":"crossref","first-page":"19688","DOI":"10.1109\/JSEN.2022.3203346","article-title":"Estimating relative angles using two inertial measurement units without magnetometers","volume":"22","author":"SY Song","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"17","key":"pone.0323821.ref011","doi-asserted-by":"crossref","first-page":"16952","DOI":"10.1109\/JSEN.2022.3175823","article-title":"Gait pattern identification and phase estimation in continuous multilocomotion mode based on inertial measurement units","volume":"22","author":"X Zhang","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"4","key":"pone.0323821.ref012","doi-asserted-by":"crossref","first-page":"4107","DOI":"10.1109\/JSEN.2022.3233653","article-title":"A flexible sensor and MIMU-based multisensor wearable system for human motion analysis","volume":"23","author":"Y Gu","year":"2023","journal-title":"IEEE Sensors J"},{"key":"pone.0323821.ref013","doi-asserted-by":"crossref","first-page":"107761","DOI":"10.1016\/j.cmpb.2023.107761","article-title":"Accurately and effectively predict the ACL force: Utilizing biomechanical landing pattern before and after-fatigue","volume":"241","author":"D Xu","year":"2023","journal-title":"Computer Methods and Programs in Biomedicine"},{"issue":"20","key":"pone.0323821.ref014","doi-asserted-by":"crossref","first-page":"19191","DOI":"10.1109\/JSEN.2022.3197182","article-title":"Microstructured flexible pressure sensor based on nanofibrous films for human motions and physiological detection","volume":"22","author":"X Chen","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"15","key":"pone.0323821.ref015","doi-asserted-by":"crossref","first-page":"14929","DOI":"10.1109\/JSEN.2022.3188115","article-title":"A novel stretchable and flexible sensor using graphite-added optical waveguide for human motion detection","volume":"22","author":"X Huang","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"8","key":"pone.0323821.ref016","doi-asserted-by":"crossref","first-page":"8713","DOI":"10.1109\/TII.2022.3221208","article-title":"SDFA: Structure-aware discriminative feature aggregation for efficient human fall detection in video","volume":"19","author":"S Zahan","year":"2023","journal-title":"IEEE Trans Ind Inf"},{"issue":"10","key":"pone.0323821.ref017","doi-asserted-by":"crossref","first-page":"7160","DOI":"10.1109\/TCSVT.2022.3178430","article-title":"Self-updatable database system based on human motion assessment framework","volume":"32","author":"K Lee","year":"2022","journal-title":"IEEE Trans Circuits Syst Video Technol"},{"issue":"7","key":"pone.0323821.ref018","doi-asserted-by":"crossref","first-page":"6910","DOI":"10.1109\/JSEN.2022.3153398","article-title":"Residual neural network and long short-term memory-based algorithm for estimating the motion trajectory of inertial measurement units","volume":"22","author":"B-S Lin","year":"2022","journal-title":"IEEE Sensors J"},{"key":"pone.0323821.ref019","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.gaitpost.2023.10.019","article-title":"A new method proposed for realizing human gait pattern recognition: Inspirations for the application of sports and clinical gait analysis","volume":"107","author":"D Xu","year":"2024","journal-title":"Gait Posture"},{"issue":"17","key":"pone.0323821.ref020","doi-asserted-by":"crossref","first-page":"17162","DOI":"10.1109\/JSEN.2022.3190503","article-title":"A novel compensatory motion detection method using multiple signals and machine learning","volume":"22","author":"P Xu","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"3","key":"pone.0323821.ref021","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1007\/s40279-022-01804-x","article-title":"Resistance training induces improvements in range of motion: A systematic review and meta-analysis","volume":"53","author":"S Alizadeh","year":"2023","journal-title":"Sports Med"},{"issue":"7","key":"pone.0323821.ref022","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1007\/s00421-022-04927-1","article-title":"A comparison of a single bout of stretching or foam rolling on range of motion in healthy adults","volume":"122","author":"A Konrad","year":"2022","journal-title":"Eur J Appl Physiol"},{"issue":"5","key":"pone.0323821.ref023","doi-asserted-by":"crossref","first-page":"4983","DOI":"10.1109\/JSEN.2023.3234929","article-title":"Kinematics analysis of arms in synchronized canoeing with wearable inertial measurement unit","volume":"23","author":"L Liu","year":"2023","journal-title":"IEEE Sensors J"},{"issue":"2","key":"pone.0323821.ref024","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1080\/24733938.2021.1910333","article-title":"Quantifying technical actions in professional soccer using foot-mounted inertial measurement units","volume":"6","author":"J Marris","year":"2022","journal-title":"Sci Med Footb"},{"issue":"1","key":"pone.0323821.ref025","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1108\/AEAT-12-2020-0308","article-title":"Review and selection of commercially available IMU for a short time inertial navigation","volume":"94","author":"K Borodacz","year":"2021","journal-title":"AEAT"},{"issue":"17","key":"pone.0323821.ref026","doi-asserted-by":"crossref","first-page":"17194","DOI":"10.1109\/JSEN.2022.3192552","article-title":"Impact of the earth rotation compensation on MEMS-IMU preintegration of factor graph optimization","volume":"22","author":"H Tang","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"1","key":"pone.0323821.ref027","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s10514-022-10067-4","article-title":"A novel framework for generalizing dynamic movement primitives under kinematic constraints","volume":"47","author":"A Sidiropoulos","year":"2022","journal-title":"Auton Robot"},{"issue":"3","key":"pone.0323821.ref028","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1049\/cit2.12125","article-title":"Recursive recurrent neural network: A novel model for manipulator control with different levels of physical constraints","volume":"8","author":"Z Li","year":"2022","journal-title":"CAAI Trans on Intel Tech"},{"issue":"4","key":"pone.0323821.ref029","doi-asserted-by":"crossref","first-page":"4595","DOI":"10.1007\/s12652-023-04582-0","article-title":"Wavelet transform and vector machines as emerging tools for computational medicine","volume":"14","author":"V Gupta","year":"2023","journal-title":"J Ambient Intell Human Comput"},{"issue":"8","key":"pone.0323821.ref030","doi-asserted-by":"crossref","first-page":"5856","DOI":"10.1016\/j.jksuci.2021.07.012","article-title":"A Hybrid robust watermarking system based on discrete cosine transform, discrete wavelet transform, and singular value decomposition","volume":"34","author":"M Begum","year":"2022","journal-title":"J King Saud Univ Comp Info Sci"},{"issue":"12","key":"pone.0323821.ref031","doi-asserted-by":"crossref","first-page":"5885","DOI":"10.1007\/s00167-023-07644-0","article-title":"Artificial intelligence-based analyses of varus leg alignment and after high tibial osteotomy show high accuracy and reproducibility","volume":"31","author":"C Stotter","year":"2023","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"pone.0323821.ref032","doi-asserted-by":"crossref","first-page":"4729","DOI":"10.1109\/JSEN.2023.3237130","article-title":"Parametric and noise effects on magnetic sensing system for monitoring human-joint motion of lower extremity in sagittal plane","volume":"23","author":"G Hu","year":"2023","journal-title":"IEEE Sensors J"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0323821","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T17:42:01Z","timestamp":1747935721000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0323821"}},"subtitle":[],"editor":[{"given":"Yaodong","family":"Gu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2025,5,22]]},"references-count":32,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,5,22]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0323821","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,22]]}}}