{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:02:56Z","timestamp":1787022176251,"version":"build-2736575974"},"reference-count":28,"publisher":"Public Library of Science (PLoS)","issue":"6","license":[{"start":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T00:00:00Z","timestamp":1750896000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"FWO","award":["18B3222N"],"award-info":[{"award-number":["18B3222N"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Robot-assisted cochlear implantation surgery (RACIS) involves the drilling of a keyhole access to the inner ear for cochlear implant placement to treat patients with severe-to-profound sensorineural hearing loss. RACIS with the HEARO-procedure does not require the drilling of a mastoidectomy and posterior tympanotomy to pass through the facial recess. Instead, it directly drills through it guarding a safe distance from both the facial nerve and chorda tympani. Cochlear implantation surgery involves a well described risk for facial nerve injury when passing through the facial recess. Neuromonitoring as a safety protocol gained great importance in conventional CI surgery and is proving its benefits in RACIS. RACIS in the HEARO-procedure involves a customized facial nerve monitoring (FNM) device that was designed and tested in an animal model study. Here, this device was retrospectively assessed in the largest series of patients undergoing the HEARO-procedure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>The safety protocol in the HEARO-procedure involves FNM and intra-operative cone-beam CT (CBCT) imaging with a 0.1\u2009mm spatial resolution. The customized FNM device was employed, using both active mono- and bipolar stimulation to estimate the distance to the facial nerve in RACIS. Linear regression was used to determine if the minimum stimulation thresholds (FNM) could significantly predict the intra-operative distance (CBCT) between the drilled trajectory and the facial nerve. Logistic regression was used to calculate if FNM can distinguish distances smaller and greater than 0.4\u2009mm to the facial nerve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The minimum stimulation thresholds significantly predicted the distances between the drilling trajectory and the facial nerve for both the monopolar (p = 0.001) and bipolar 3 (p = 0.008) stimulation configuration. Both the monopolar (\u03b2 = -0.189, S.E. = 0.063, p = 0.003) and bipolar 3 (\u03b2 = -0.187, S.E. = 0.080, p = 0.019) stimulation configuration are negative and significant predictors of the probability of the distance being smaller than 0.4\u2009mm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>FNM will alert the surgeon when the drilling trajectory comes closer than 0.4\u2009mm to the facial nerve in RACIS. A linear relationship was observed between the minimum stimulation thresholds and the intra-operative distance towards the facial nerve.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0326614","type":"journal-article","created":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T13:28:17Z","timestamp":1750944497000},"page":"e0326614","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":4,"title":["Retrospective evaluation of Facial nerve monitoring to prevent nerve damage during robotic drilling in the largest series of patients undergoing the HEARO-procedure"],"prefix":"10.1371","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5141-4292","authenticated-orcid":true,"given":"Jaouad","family":"Abari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Matulic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo","family":"Galeazzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masoud Zoka","family":"Assadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Van de Heyning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0416-4005","authenticated-orcid":true,"given":"Vedat","family":"Topsakal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2025,6,26]]},"reference":[{"key":"pone.0326614.ref001","author":"WHO","year":"2021"},{"key":"pone.0326614.ref002","article-title":"The World Report on Hearing, what does it mean for me and how can it improve access to hearing devices?","author":"P D\u2019Haese","year":"2023","journal-title":"Ear Nose Throat J"},{"issue":"7","key":"pone.0326614.ref003","doi-asserted-by":"crossref","first-page":"077201","DOI":"10.1121\/10.0012825","article-title":"Celebrating the one millionth cochlear implant","volume":"2","author":"F-G Zeng","year":"2022","journal-title":"JASA Express Lett"},{"issue":"3","key":"pone.0326614.ref004","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1001\/jamaoto.2013.1744","article-title":"Cochlear implantation in adults: a systematic review and meta-analysis","volume":"139","author":"JM Gaylor","year":"2013","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"issue":"3","key":"pone.0326614.ref005","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1017\/S0022215100086977","article-title":"The surgery for multiple-electrode cochlear implantations","volume":"93","author":"GM Clark","year":"1979","journal-title":"J Laryngol Otol"},{"issue":"1","key":"pone.0326614.ref006","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S0030-6665(20)33020-6","article-title":"Posterior tympanotomy: experiences and surgical details","volume":"5","author":"C Jansen","year":"1972","journal-title":"Otolaryngol Clin North Am"},{"issue":"12","key":"pone.0326614.ref007","doi-asserted-by":"crossref","first-page":"4199","DOI":"10.1007\/s00405-016-4124-0","article-title":"Facial palsy following cochlear implantation","volume":"273","author":"F Alzhrani","year":"2016","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"4","key":"pone.0326614.ref008","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1002\/lary.23316","article-title":"The prevalence and clinical course of facial nerve paresis following cochlear implant surgery","volume":"123","author":"JJ Thom","year":"2013","journal-title":"Laryngoscope"},{"issue":"4","key":"pone.0326614.ref009","doi-asserted-by":"crossref","DOI":"10.1126\/scirobotics.aal4916","article-title":"Instrument flight to the inner ear","volume":"2","author":"S Weber","year":"2017","journal-title":"Sci Robot"},{"issue":"1","key":"pone.0326614.ref010","doi-asserted-by":"crossref","first-page":"3340","DOI":"10.1038\/s41598-020-58648-6","article-title":"Prediction of the Cochlear Implant Electrode Insertion Depth: Clinical Applicability of two Analytical Cochlear Models","volume":"10","author":"G Mertens","year":"2020","journal-title":"Sci Rep"},{"issue":"5","key":"pone.0326614.ref011","doi-asserted-by":"crossref","first-page":"104360","DOI":"10.1016\/j.amjoto.2024.104360","article-title":"Entirely robotic cochlear implant surgery","volume":"45","author":"J Abari","year":"2024","journal-title":"Am J Otolaryngol"},{"issue":"4","key":"pone.0326614.ref012","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1080\/00016489.2017.1278573","article-title":"Robotic cochlear implantation: surgical procedure and first clinical experience","volume":"137","author":"M Caversaccio","year":"2017","journal-title":"Acta Otolaryngol"},{"issue":"8","key":"pone.0326614.ref013","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0220543","article-title":"Robotic middle ear access for cochlear implantation: First in man","volume":"14","author":"M Caversaccio","year":"2019","journal-title":"PLoS One"},{"issue":"1","key":"pone.0326614.ref014","first-page":"138","article-title":"Next-generation Robotics in Otology: The HEARO Procedure","volume":"36","author":"AM Tekin","year":"2025","journal-title":"J Craniofac Surg"},{"key":"pone.0326614.ref015","doi-asserted-by":"crossref","DOI":"10.3389\/fneur.2022.804507","article-title":"First study in men evaluating a surgical robotic tool providing autonomous inner ear access for cochlear implantation","volume":"13","author":"V Topsakal","year":"2022","journal-title":"Frontiers in Neurology"},{"key":"pone.0326614.ref016","doi-asserted-by":"crossref","first-page":"596498","DOI":"10.1155\/2014\/596498","article-title":"Semiautomatic cochleostomy target and insertion trajectory planning for minimally invasive cochlear implantation","volume":"2014","author":"W Wimmer","year":"2014","journal-title":"Biomed Res Int"},{"issue":"7","key":"pone.0326614.ref017","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1097\/MAO.0b013e31829561b6","article-title":"In vitro accuracy evaluation of image-guided robot system for direct cochlear access","volume":"34","author":"B Bell","year":"2013","journal-title":"Otol Neurotol"},{"issue":"5","key":"pone.0326614.ref018","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1001\/archotol.1988.01860170064020","article-title":"Surgical dimensions of the facial recess in adults and children","volume":"114","author":"SA Bielamowicz","year":"1988","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"pone.0326614.ref019","doi-asserted-by":"crossref","DOI":"10.3389\/fsurg.2019.00058","article-title":"Prospective validation of facial nerve monitoring to prevent nerve damage during robotic drilling","volume":"6","author":"J Ans\u00f3","year":"2019","journal-title":"Frontiers in Surgery"},{"issue":"3","key":"pone.0326614.ref020","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/MAO.0000000000000187","article-title":"Feasibility of using EMG for early detection of the facial nerve during robotic direct cochlear access","volume":"35","author":"J Ans\u00f3","year":"2014","journal-title":"Otol Neurotol"},{"issue":"10","key":"pone.0326614.ref021","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.1007\/s10439-018-2094-7","article-title":"Neuromonitoring during robotic cochlear implantation: initial clinical experience","volume":"46","author":"J Ans\u00f3","year":"2018","journal-title":"Annals of Biomedical Engineering"},{"issue":"5","key":"pone.0326614.ref022","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1038\/s42256-021-00349-4","article-title":"A human in the loop in surgery automation","volume":"3","author":"E Fosch-Villaronga","year":"2021","journal-title":"Nat Mach Intell"},{"issue":"3","key":"pone.0326614.ref023","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1007\/s12369-022-00875-0","article-title":"The Role of Humans in Surgery Automation","volume":"15","author":"E Fosch-Villaronga","year":"2022","journal-title":"Int J of Soc Robotics"},{"issue":"6","key":"pone.0326614.ref024","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1002\/ca.20218","article-title":"Morphometric study of the external and middle ear anatomy in sheep: a possible model for ear experiments","volume":"19","author":"VAA Seibel","year":"2006","journal-title":"Clin Anat"},{"issue":"1","key":"pone.0326614.ref025","doi-asserted-by":"crossref","first-page":"28426","DOI":"10.1038\/s41598-024-79722-3","article-title":"Defining the ideal trajectory into the inner ear in image-guided cochlear implant surgery","volume":"14","author":"J Abari","year":"2024","journal-title":"Sci Rep"},{"issue":"5","key":"pone.0326614.ref026","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1007\/s10439-015-1450-0","article-title":"Temperature Prediction Model for Bone Drilling Based on Density Distribution and In Vivo Experiments for Minimally Invasive Robotic Cochlear Implantation","volume":"44","author":"A Feldmann","year":"2016","journal-title":"Ann Biomed Eng"},{"issue":"8","key":"pone.0326614.ref027","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1002\/lary.24520","article-title":"Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation","volume":"124","author":"RF Labadie","year":"2014","journal-title":"Laryngoscope"},{"issue":"12","key":"pone.0326614.ref028","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.medengphy.2016.10.001","article-title":"Reducing temperature elevation of robotic bone drilling","volume":"38","author":"A Feldmann","year":"2016","journal-title":"Med Eng Phys"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0326614","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T13:28:24Z","timestamp":1750944504000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0326614"}},"subtitle":[],"editor":[{"given":"Annalisa","family":"Pace","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2025,6,26]]},"references-count":28,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,6,26]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0326614","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,26]]}}}