{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T23:54:25Z","timestamp":1791244465920,"version":"4.1.0"},"reference-count":22,"publisher":"Public Library of Science (PLoS)","issue":"9","license":[{"start":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:00:00Z","timestamp":1759104000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007210","name":"Varian Medical Systems","doi-asserted-by":"publisher","award":["2020016"],"award-info":[{"award-number":["2020016"]}],"id":[{"id":"10.13039\/100007210","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>The purpose of this study was to determine the residual patient positioning error of ocular proton treatment based on daily setup X-ray images and tantalum clips. The residual day-to-day patient positioning accuracy in a cohort of 60 patients and 240 fractions was determined in two steps. The 3D tantalum clips\u2019 positions in the orthogonal X-ray images just prior to aperture placement were registered with 3D clips\u2019 positions derived from the reference data from treatment planning. The aperture, placed before irradiation, reduced the field of view in axial images blocking clips partially or completely in most cases. The clips\u2019 positions after aperture placement in the lateral images were compared with the reference clips\u2019 positions. Partially visible clips in the axial image were registered to the clips in the axial image prior to aperture placement. The day-to-day deviations to aperture placement were corrected with the registration results for translations only. The residual day-to-day patient position variations just prior to irradiation were \u22120.06\u2009\u00b1\u20090.27\u2009mm (mean\u2009\u00b1\u20091SD) for the left-right direction, \u22120.01\u2009\u00b1\u20090.23\u2009mm for the anterior-posterior direction and \u22120.01\u2009\u00b1\u20090.19\u2009mm for the superior-inferior direction. This data was further investigated by differentiating for treated eye, gazing eye and the use of eyelid retractor. This yielded no significant differences. The residual patient positioning errors are small for patients treated at the dedicated eyeline, indicating that the patient positioning workflow using tantalum clips is highly accurate. The reported errors can be used for ocular proton margin calculations and for the evaluation of a clipless ocular proton therapy workflow.<\/jats:p>","DOI":"10.1371\/journal.pone.0333294","type":"journal-article","created":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T17:25:30Z","timestamp":1759166730000},"page":"e0333294","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy of day-to-day patient positioning in ocular proton therapy with a dedicated beamline"],"prefix":"10.1371","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-6630-3761","authenticated-orcid":true,"given":"Martijn","family":"Hol","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kees H.","family":"Spruijt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myra F.","family":"Rodrigues","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yvonne L. B.","family":"Klaver","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasper","family":"Kouwenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pauline A. C.","family":"Bakker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregorius P. M.","family":"Luyten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emine","family":"Kili\u00e7","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0479-5587","authenticated-orcid":true,"given":"Jan-Willem M.","family":"Beenakker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleftheria","family":"Astreinidou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Coen R. N.","family":"Rasch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2025,9,29]]},"reference":[{"key":"pone.0333294.ref001","unstructured":"IKNL. Nkr cijfers. Accessed 2023 July 19. https:\/\/iknl.nl\/nkr-cijfers"},{"key":"pone.0333294.ref002","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.ejca.2016.09.009","article-title":"Ruthenium-106 brachytherapy for choroidal melanoma without transpupillary thermotherapy: similar efficacy with improved visual outcome","volume":"68","author":"M Marinkovic","year":"2016","journal-title":"Eur J Cancer"},{"issue":"8","key":"pone.0333294.ref003","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1200\/JCO.2006.10.0131","article-title":"Proton therapy in clinical practice: current clinical evidence","volume":"25","author":"M Brada","year":"2007","journal-title":"J Clin Oncol"},{"issue":"3","key":"pone.0333294.ref004","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/j.ijrobp.2006.01.020","article-title":"Proton beam radiotherapy for uveal melanoma: results of Curie Institut-Orsay proton therapy center (ICPO)","volume":"65","author":"R Dendale","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"11","key":"pone.0333294.ref005","doi-asserted-by":"crossref","first-page":"4666","DOI":"10.1167\/iovs.06-0659","article-title":"Proton beam irradiation of uveal melanomas: the first 30 years. The Weisenfeld lecture","volume":"47","author":"ES Gragoudas","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"pone.0333294.ref006","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.radonc.2007.03.001","article-title":"Proton therapy - a systematic review of clinical effectiveness","volume":"83","author":"DR Olsen","year":"2007","journal-title":"Radiother Oncol"},{"issue":"8","key":"pone.0333294.ref007","doi-asserted-by":"crossref","first-page":"4506","DOI":"10.1002\/mp.15024","article-title":"Characterization of the HollandPTC proton therapy beamline dedicated to uveal melanoma treatment and an interinstitutional comparison","volume":"48","author":"E Fleury","year":"2021","journal-title":"Med Phys"},{"issue":"5","key":"pone.0333294.ref008","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1016\/j.ijrobp.2005.01.016","article-title":"Proton beam radiotherapy of choroidal melanoma: the Liverpool-Clatterbridge experience","volume":"62","author":"B Damato","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"pone.0333294.ref009","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.apradiso.2008.06.012","article-title":"Protontherapy of eye tumours in the UK: a review of treatment at Clatterbridge","volume":"67","author":"A Kacperek","year":"2009","journal-title":"Appl Radiat Isot"},{"issue":"4","key":"pone.0333294.ref010","doi-asserted-by":"crossref","first-page":"50","DOI":"10.21037\/cco.2016.07.06","article-title":"Proton therapy for the management of uveal melanoma and other ocular tumors","volume":"5","author":"KK Mishra","year":"2016","journal-title":"Chin Clin Oncol"},{"issue":"2","key":"pone.0333294.ref011","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.oret.2022.06.019","article-title":"Comparison of magnetic resonance imaging-based and conventional measurements for proton beam therapy of uveal melanoma","volume":"7","author":"MG Jaarsma-Coes","year":"2023","journal-title":"Ophthalmol Retina"},{"issue":"5","key":"pone.0333294.ref012","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.ijrobp.2024.06.017","article-title":"PTCOG ocular statement: expert summary of current practices and future developments in ocular proton therapy","volume":"120","author":"J Hrbacek","year":"2024","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"pone.0333294.ref013","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.ejmp.2019.02.020","article-title":"A platform for patient positioning and motion monitoring in ocular proton therapy with a non-dedicated beamline","volume":"59","author":"R Via","year":"2019","journal-title":"Phys Med"},{"key":"pone.0333294.ref014","doi-asserted-by":"crossref","first-page":"103358","DOI":"10.1016\/j.ejmp.2024.103358","article-title":"Uncertainties in ocular proton planning and their impact on required margins","volume":"121","author":"J Wulff","year":"2024","journal-title":"Phys Med"},{"issue":"1","key":"pone.0333294.ref015","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","article-title":"Errors and margins in radiotherapy","volume":"14","author":"M Van Herk","year":"2004","journal-title":"Semin Radiat Oncol"},{"issue":"1","key":"pone.0333294.ref016","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.ijrobp.2003.08.029","article-title":"A modified relocatable stereotactic frame for irradiation of eye melanoma: design and evaluation of treatment accuracy","volume":"58","author":"K Muller","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"pone.0333294.ref017","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/S0167-8140(01)00413-3","article-title":"A linac-based stereotactic irradiation technique of uveal melanoma","volume":"61","author":"K Dieckmann","year":"2001","journal-title":"Radiother Oncol"},{"issue":"3","key":"pone.0333294.ref018","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1002\/mp.14665","article-title":"Three-dimensional MRI-based treatment planning approach for non-invasive ocular proton therapy","volume":"48","author":"E Fleury","year":"2021","journal-title":"Med Phys"},{"issue":"3","key":"pone.0333294.ref019","doi-asserted-by":"crossref","first-page":"101149","DOI":"10.1016\/j.adro.2022.101149","article-title":"Inter-observer variability in MR-based target volume delineation of uveal melanoma","volume":"8","author":"MG Jaarsma-Coes","year":"2022","journal-title":"Adv Radiat Oncol"},{"key":"pone.0333294.ref020","doi-asserted-by":"crossref","first-page":"100598","DOI":"10.1016\/j.phro.2024.100598","article-title":"Geometrical accuracy of magnetic resonance imaging for ocular proton therapy planning","volume":"31","author":"L Klaassen","year":"2024","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"5","key":"pone.0333294.ref021","doi-asserted-by":"crossref","first-page":"2186","DOI":"10.1002\/mp.12841","article-title":"Noninvasive eye localization in ocular proton therapy through optical eye tracking: a proof of concept","volume":"45","author":"R Via","year":"2018","journal-title":"Med Phys"},{"issue":"5","key":"pone.0333294.ref022","doi-asserted-by":"crossref","first-page":"2237","DOI":"10.1002\/mp.14087","article-title":"Technical Note: benchmarking automated eye tracking and human detection for motion monitoring in ocular proton therapy","volume":"47","author":"R Via","year":"2020","journal-title":"Med Phys"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0333294","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T17:25:34Z","timestamp":1759166734000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0333294"}},"subtitle":[],"editor":[{"given":"Gayle E.","family":"Woloschak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2025,9,29]]},"references-count":22,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2025,9,29]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0333294","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,29]]}}}