{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T14:34:54Z","timestamp":1776436494497,"version":"3.51.2"},"reference-count":52,"publisher":"Public Library of Science (PLoS)","issue":"11","license":[{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100018717","name":"Karamano\u00c4\u0178lu Mehmetbey \u00c3\u0153niversitesi","doi-asserted-by":"publisher","award":["14-M-24"],"award-info":[{"award-number":["14-M-24"]}],"id":[{"id":"10.13039\/501100018717","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018717","name":"Karamano\u00c4\u0178lu Mehmetbey \u00c3\u0153niversitesi","doi-asserted-by":"publisher","award":["51-M-24"],"award-info":[{"award-number":["51-M-24"]}],"id":[{"id":"10.13039\/501100018717","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>Kinect is a markerless, portable, and affordable motion analysis tool used in clinical, rehabilitation, and sports settings. This study aimed to assess upper limb (shoulder and elbow) and cervical joint angles in elite female weightlifters using Azure Kinect and a digital goniometer, and to evaluate the Kinect\u2019s validity and reliability. Joint angles were measured in elite female weightlifters (n\u2009=\u200921) using both a digital goniometer and Azure Kinect, with three repetitions per movement under standardized conditions (within a stabilization cage). Mean values were used for analysis. Statistical analysis included descriptive metrics and non-parametric tests. Tool comparisons were conducted using the Wilcoxon signed-rank test, Spearman\u2019s correlation coefficient, and Bland\u2013Altman plots. Reliability was evaluated through the Intraclass Correlation Coefficient (ICC), Coefficient of Variation (CV), and Coefficient of Repeatability (CR), with statistical significance set at p\u2009&lt;\u20090.05. Most joint angle measurements showed no statistically significant differences between the digital goniometer and Azure Kinect (p\u2009&gt;\u20090.05), although small discrepancies appeared in some movements. High correlation coefficients (r\u2009=\u20090.82\u20130.99) and strong agreement based on Intraclass Correlation Coefficient (ICC\u2009=\u20090.97\u20130.99) were observed. Bland\u2013Altman analysis revealed minimal systematic bias and narrow confidence intervals. Comparable values in Coefficient of Variation (CV) and Coefficient of Repeatability (CR) indicated high stability and repeatability for both tools. Overall, results support Azure Kinect as a valid and reliable alternative to traditional digital goniometry for assessing cervical and upper extremity joint range of motion.<\/jats:p>","DOI":"10.1371\/journal.pone.0334890","type":"journal-article","created":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T18:27:36Z","timestamp":1763749656000},"page":"e0334890","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":1,"title":["Azure Kinect for joint range of motion analysis: A validity and reliability evaluation in elite female weightlifters"],"prefix":"10.1371","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9905-2908","authenticated-orcid":true,"given":"Serkan","family":"\u00d6r\u00fcc\u00fc","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2338-6546","authenticated-orcid":true,"given":"Kenan","family":"Erda\u011f\u0131","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B\u00fclent","family":"I\u015f\u0131k","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8781-3877","authenticated-orcid":true,"given":"Erkan","family":"\u00d6zbay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1198-2447","authenticated-orcid":true,"given":"Usame \u00d6mer","family":"Osmano\u011flu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2025,11,21]]},"reference":[{"issue":"6","key":"pone.0334890.ref001","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.math.2014.05.009","article-title":"Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians","volume":"19","author":"S Milanese","year":"2014","journal-title":"Man Ther"},{"issue":"12","key":"pone.0334890.ref002","doi-asserted-by":"crossref","first-page":"1867","DOI":"10.1093\/ptj\/67.12.1867","article-title":"Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity","volume":"67","author":"RL Gajdosik","year":"1987","journal-title":"Phys Ther"},{"issue":"2","key":"pone.0334890.ref003","doi-asserted-by":"crossref","first-page":"107","DOI":"10.3109\/09593989809057153","article-title":"Inter-tester comparison between visual estimation and goniometric measurement of ankle dorsiflexion","volume":"14","author":"P Croxford","year":"1998","journal-title":"Physiother Theory Pract"},{"issue":"5","key":"pone.0334890.ref004","article-title":"Reliability and Validity of a Smartphone-Based Inclinometer Application Measuring Shoulder Internal Rotation","volume":"7","author":"T Lau","year":"2020","journal-title":"J Phys Fitness Med Treat Sport"},{"issue":"2","key":"pone.0334890.ref005","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2340\/165019771986184749","article-title":"Radiographic verification of knee goniometry","volume":"18","author":"CS Enwemeka","year":"1986","journal-title":"Scand J Rehabil Med"},{"issue":"4","key":"pone.0334890.ref006","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S0004-9514(14)60274-9","article-title":"Reliability of five methods for assessing shoulder range of motion","volume":"47","author":"K Hayes","year":"2001","journal-title":"Aust J Physiother"},{"issue":"5","key":"pone.0334890.ref007","article-title":"Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review","volume":"14","author":"JWL Keogh","year":"2019","journal-title":"PLoS One"},{"issue":"1","key":"pone.0334890.ref008","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1177\/036354659001800110","article-title":"Variability and reliability of joint measurements","volume":"18","author":"AM Bovens","year":"1990","journal-title":"Am J Sports Med"},{"issue":"9","key":"pone.0334890.ref009","doi-asserted-by":"crossref","first-page":"2644","DOI":"10.1589\/jpts.28.2644","article-title":"The effect of proficiency level on measurement error of range of motion","volume":"28","author":"K Akizuki","year":"2016","journal-title":"J Phys Ther Sci"},{"issue":"1","key":"pone.0334890.ref010","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s40798-018-0167-7","article-title":"Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review","volume":"4","author":"CP Walmsley","year":"2018","journal-title":"Sports Med Open"},{"issue":"3","key":"pone.0334890.ref011","first-page":"98","article-title":"Evaluating change in clinical status: reliability and measures of agreement for the assessment of glenohumeral range of motion","volume":"5","author":"SW Muir","year":"2010","journal-title":"N Am J Sports Phys Ther"},{"issue":"1","key":"pone.0334890.ref012","article-title":"Intra and inter examiner reliability and measurement error of goniometer and digital inclinometer use","volume":"18","author":"CM dos Santos","year":"2012","journal-title":"Revista Brasileira de Medicina do Esporte"},{"issue":"1","key":"pone.0334890.ref013","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jse.2011.06.018","article-title":"Validation of a photography-based goniometry method for measuring joint range of motion","volume":"21","author":"D Blonna","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"issue":"21","key":"pone.0334890.ref014","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0b013e3182a0dbc5","article-title":"Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion: repeatability and reliability compared with an electrogoniometer","volume":"38","author":"M Tojima","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"issue":"24","key":"pone.0334890.ref015","doi-asserted-by":"crossref","first-page":"7238","DOI":"10.3390\/s20247238","article-title":"The Reliability and Validity of Wearable Inertial Sensors Coupled with the Microsoft Kinect to Measure Shoulder Range-of-Motion","volume":"20","author":"P Beshara","year":"2020","journal-title":"Sensors (Basel)"},{"issue":"6","key":"pone.0334890.ref016","article-title":"Measurement of Shoulder Range of Motion in Patients with Adhesive Capsulitis Using a Kinect","volume":"10","author":"SH Lee","year":"2015","journal-title":"PLoS One"},{"key":"pone.0334890.ref017","first-page":"202","article-title":"Quantitative evaluation of the Microsoft KinectTM for use in an upper extremity virtual rehabilitation environment.","author":"ME Nixon","year":"2013","journal-title":"International Conference on Virtual Rehabilitation (ICVR)"},{"key":"pone.0334890.ref018","first-page":"190","article-title":"Development and preliminary validation of an interactive remote physical therapy system","volume":"2015","author":"AK Mishra","year":"2015","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"4","key":"pone.0334890.ref019","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.physio.2015.02.002","article-title":"Validity and reliability of Kinect skeleton for measuring shoulder joint angles: a feasibility study","volume":"101","author":"ME Huber","year":"2015","journal-title":"Physiotherapy"},{"key":"pone.0334890.ref020","first-page":"4605","article-title":"Accurate upper body rehabilitation system using kinect","volume":"2016","author":"S Sinha","year":"2016","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"1","key":"pone.0334890.ref021","article-title":"A Novel Automatic Tracking Method of Moving Image Sequence Marker Points Uses Kinect and Wireless Network Technology","volume":"2022","author":"G Chen","year":"2022","journal-title":"Wireless Commun Mobile Comput"},{"key":"pone.0334890.ref022","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.medengphy.2019.10.017","article-title":"Reliability and validity analyzes of Kinect V2 based measurement system for shoulder motions","volume":"76","author":"B \u00c7ubuk\u00e7u","year":"2020","journal-title":"Med Eng Phys"},{"issue":"1","key":"pone.0334890.ref023","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0279697","article-title":"Accuracy and repeatability of the Microsoft Azure Kinect for clinical measurement of motor function","volume":"18","author":"J Bertram","year":"2023","journal-title":"PLoS One"},{"issue":"1","key":"pone.0334890.ref024","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1515\/cdbme-2015-0045","article-title":"Kinect based physiotherapy system for home use","volume":"1","author":"D Haas","year":"2015","journal-title":"Curr Direct Biomed Eng"},{"key":"pone.0334890.ref025","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2022\/1101002","article-title":"Algorithm for Swimmers\u2019 Starting Posture Correction Based on Kinect","volume":"2022","author":"Z Chang","year":"2022","journal-title":"Math Problems Eng"},{"key":"pone.0334890.ref026","first-page":"1","author":"A Chatzitofis","year":"2013","journal-title":"Three-dimensional monitoring of weightlifting for computer assisted training. In: Proceedings of the Virtual Reality International Conference: Laval Virtual (VRIC\u201913)"},{"key":"pone.0334890.ref027","volume-title":"Measurement of Joint Motion: A Guide to Goniometry","author":"CC Norkin","year":"1998","edition":"3"},{"key":"pone.0334890.ref028","volume-title":"Kinesiology: Scientific Basis of Human Motion","author":"K Luttgens","year":"1997","edition":"9"},{"issue":"1","key":"pone.0334890.ref029","doi-asserted-by":"crossref","first-page":"15811","DOI":"10.1038\/s41598-024-66798-0","article-title":"Performance of Microsoft Azure Kinect DK as a tool for estimating human body segment lengths","volume":"14","author":"S-A Wang","year":"2024","journal-title":"Sci Rep"},{"key":"pone.0334890.ref030","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-319-61554-7","volume-title":"Automated electronic filter design: With emphasis on distributed filters","author":"A Banerjee","year":"2018","edition":"2"},{"key":"pone.0334890.ref031","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4614-4547-0_33","article-title":"Sensors and their signal conditioning for dynamic acceleration, force, pressure, and sound applications.","volume-title":"Handbook of Experimental Structural Dynamics","author":"G Foss","year":"2022"},{"key":"pone.0334890.ref032","doi-asserted-by":"crossref","first-page":"81097","DOI":"10.1109\/ACCESS.2021.3085515","article-title":"Optimal Approximation of Fractional-Order Butterworth Filter Based on Weighted Sum of Classical Butterworth Filters","volume":"9","author":"S Mahata","year":"2021","journal-title":"IEEE Access"},{"key":"pone.0334890.ref033","first-page":"27","article-title":"Analog Filters.","volume-title":"Signals and Systems","author":"KD Rao","year":"2018"},{"issue":"1","key":"pone.0334890.ref034","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s00034-022-02113-4","article-title":"Two-Dimensional Z-space Filtering Using Pulse-Transfer Function","volume":"42","author":"C Ciulla","year":"2022","journal-title":"Circuits Syst Signal Process"},{"key":"pone.0334890.ref035","first-page":"19","article-title":"Natural Interaction in Medical Training.","author":"A Del Bimbo","year":"2017","journal-title":"Human\u2013Computer Interaction Series. Tools and Applications. Cham: Springer International Publishing"},{"issue":"1","key":"pone.0334890.ref036","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s12916-021-02223-x","article-title":"Impact of a school-based health intervention program on body composition among South African primary schoolchildren: results from the KaziAfya cluster-randomized controlled trial","volume":"20","author":"KZ Long","year":"2022","journal-title":"BMC Med"},{"key":"pone.0334890.ref037","article-title":"Anthropometry and sports performance.","volume-title":"Anthropometrica: A textbook of body measurement for sports and health courses","author":"K Norton","year":"1996"},{"issue":"18","key":"pone.0334890.ref038","doi-asserted-by":"crossref","first-page":"5104","DOI":"10.3390\/s20185104","article-title":"Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study","volume":"20","author":"JA Albert","year":"2020","journal-title":"Sensors (Basel)"},{"key":"pone.0334890.ref039","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.future.2021.04.003","article-title":"Kinect-based integrated physiotherapy mentor application for shoulder damage","volume":"122","author":"B \u00c7ubuk\u00e7u","year":"2021","journal-title":"Future Generat Comput Syst"},{"issue":"1","key":"pone.0334890.ref040","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s13673-020-00256-4","article-title":"Multiple Kinect based system to monitor and analyze key performance indicators of physical training","volume":"10","author":"K Ryselis","year":"2020","journal-title":"Hum Cent Comput Inf Sci"},{"issue":"10","key":"pone.0334890.ref041","doi-asserted-by":"crossref","first-page":"3798","DOI":"10.3390\/s22103798","article-title":"Evaluating Automatic Body Orientation Detection for Indoor Location from Skeleton Tracking Data to Detect Socially Occupied Spaces Using the Kinect v2, Azure Kinect and Zed 2i","volume":"22","author":"VAL Sosa-Le\u00f3n","year":"2022","journal-title":"Sensors (Basel)"},{"issue":"13","key":"pone.0334890.ref042","doi-asserted-by":"crossref","first-page":"6013","DOI":"10.3390\/s23136013","article-title":"Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study","volume":"23","author":"M Palmieri","year":"2023","journal-title":"Sensors (Basel)"},{"issue":"7","key":"pone.0334890.ref043","doi-asserted-by":"crossref","first-page":"12444","DOI":"10.1109\/JSEN.2025.3541821","article-title":"SitPose: Real-Time Detection of Sitting Posture and Sedentary Behavior Using Ensemble Learning With Depth Sensor","volume":"25","author":"H Jin","year":"2025","journal-title":"IEEE Sensors J"},{"issue":"2","key":"pone.0334890.ref044","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"TK Koo","year":"2016","journal-title":"J Chiropr Med"},{"issue":"3","key":"pone.0334890.ref045","first-page":"307","article-title":"Measurement in Medicine: The Analysis of Method Comparison Studies","volume":"32","author":"DG Altman","year":"1983","journal-title":"J Roy Statist Soc Series D"},{"issue":"24","key":"pone.0334890.ref046","doi-asserted-by":"crossref","first-page":"7073","DOI":"10.3390\/s20247073","article-title":"The Validity and Reliability of the Microsoft Kinect for Measuring Trunk Compensation during Reaching","volume":"20","author":"MH Foreman","year":"2020","journal-title":"Sensors (Basel)"},{"key":"pone.0334890.ref047","article-title":"Development of basic taekwondo training system application based on real time motion capture using Microsoft Kinect.","author":"NA Sani","year":"2015","journal-title":"Information Systems International Conference (ISICO)"},{"issue":"7","key":"pone.0334890.ref048","doi-asserted-by":"crossref","first-page":"2735","DOI":"10.3390\/s22072735","article-title":"Validity and Reliability of Kinect v2 for Quantifying Upper Body Kinematics during Seated Reaching","volume":"22","author":"G Faity","year":"2022","journal-title":"Sensors (Basel)"},{"issue":"7","key":"pone.0334890.ref049","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1080\/09593985.2017.1422206","article-title":"Shoulder and elbow range of motion for the performance of activities of daily living: A systematic review","volume":"34","author":"AM Oosterwijk","year":"2018","journal-title":"Physiother Theory Pract"},{"key":"pone.0334890.ref050","first-page":"6","author":"S Gauthier","year":"2014","journal-title":"Human movement quantification using Kinect for in-home physical exercise monitoring. In: 2014 IEEE International Conference on Computational Intelligence and Virtual Environments for Measurement Systems and Applications (CIVEMSA)"},{"key":"pone.0334890.ref051","author":"ECO Syarif","year":"2020","journal-title":"Kinect-based application system design for pencak silat movement using support vector machines (SVMs). In: Proceedings of the International Conference on Industrial Engineering and Operations Management"},{"issue":"10","key":"pone.0334890.ref052","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1016\/j.jse.2022.04.007","article-title":"Reliability and agreement of Azure Kinect and Kinect v2 depth sensors in the shoulder joint range of motion estimation","volume":"31","author":"U \u00d6zsoy","year":"2022","journal-title":"J Shoulder Elbow Surg"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0334890","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T18:27:46Z","timestamp":1763749666000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0334890"}},"subtitle":[],"editor":[{"given":"Jyotindra","family":"Narayan","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2025,11,21]]},"references-count":52,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11,21]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0334890","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,21]]}}}