{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T14:57:00Z","timestamp":1785164220463,"version":"3.55.0"},"reference-count":29,"publisher":"Public Library of Science (PLoS)","issue":"1","license":[{"start":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T00:00:00Z","timestamp":1767830400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To investigate changes in refractive and corneal astigmatism after Hydrus Microstent (Alcon Inc., Geneva, Switzerland) implantation during microinvasive glaucoma surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>One German medical center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Retrospective, non-randomized, observational cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Subjective refraction was obtained mandatorily and keratometry (Pentacam, OCULUS Optikger\u00e4te GmbH, Wetzlar, Germany) optionally preoperatively and after 3 months (D90). Refractive astigmatism was analyzed using three-dimensional (3D) power vectors, including the spherical equivalent,\n                      <jats:italic>M<\/jats:italic>\n                      , the Jackson cross-cylinder projections to the 0\u00b0 and 90\u00b0 meridian (\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0<\/jats:sub>\n                      ) and to the 45\u00b0 and 135\u00b0 meridian (\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45<\/jats:sub>\n                      ), and the blurring power vector\n                      <jats:italic>B<\/jats:italic>\n                      . Corneal anterior and posterior surface astigmatism was investigated using the vectorial parameters\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0<\/jats:sub>\n                      ,\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45<\/jats:sub>\n                      , and\n                      <jats:italic>B<\/jats:italic>\n                      . A 3D power vector time-course analysis of refractive astigmatism was performed using multivariate pairwise testing, and linear mixed-effects models, accounting for patient ID as a random effect, were used for the remaining analyses.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec005\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 90 ocular hypertension\/glaucoma eyes were included. Sixty eyes were implanted with a Hydrus Microstent and phacoemulsified, and 30 eyes underwent implantation as a stand-alone procedure. Univariate analysis of the refractive cylinder showed no variation over time in any cohort (Phacoemulsification: C\n                      <jats:sub>D0<\/jats:sub>\n                      \u2009=\u2009\u20131.3\u2009\u00b1\u20090.9 D vs. C\n                      <jats:sub>D90\u2009<\/jats:sub>\n                      =\u2009\u20131.2\u2009\u00b1\u20091.2 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.6; Stand-alone: C\n                      <jats:sub>D0<\/jats:sub>\n                      \u2009=\u2009\u20131.6\u2009\u00b1\u20091.3 D vs. C\n                      <jats:sub>D90<\/jats:sub>\n                      \u2009=\u2009\u20131.6\u2009\u00b1\u20091.2 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.9), and no relevant time\u2013by\u2013group interaction was observed. Multivariate astigmatism analysis (\n                      <jats:italic>M<\/jats:italic>\n                      ,\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0<\/jats:sub>\n                      ,\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45<\/jats:sub>\n                      ) indicated a significant change in the phacoemulsification cohort (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0003), in contrast to the stand-alone procedure cohort (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.5). In the phacoemulsification cohort,\n                      <jats:italic>B<\/jats:italic>\n                      significantly declined from 2.9\u2009\u00b1\u20092.8 D to 1.2\u2009\u00b1\u20091.0 D (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.0001) but remained stable in the stand-alone group (2.7\u2009\u00b1\u20093.5 D to 2.8\u2009\u00b1\u20093.4 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.07). Corneal astigmatism analysis, based on 55 eyes from 37 patients, showed that the magnitudes of the\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0<\/jats:sub>\n                      and\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45<\/jats:sub>\n                      vectors remained stable over time for both the anterior (D0:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0\u2009<\/jats:sub>\n                      =\u2009\u20130.12\u2009\u00b1\u20090.07 D, D90:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0\u2009<\/jats:sub>\n                      =\u2009\u20130.21\u2009\u00b1\u20090.07 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.12; D0:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45\u2009<\/jats:sub>\n                      =\u2009\u20130.05\u2009\u00b1\u20090.05 D, D90:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45\u2009<\/jats:sub>\n                      =\u2009\u20130.01\u2009\u00b1\u20090.05 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.5) and posterior surfaces (D0:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0\u2009<\/jats:sub>\n                      =\u20090.12\u2009\u00b1\u20090.01 D, D90:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>0\u2009<\/jats:sub>\n                      =\u20090.13\u2009\u00b1\u20090.01 D,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.3; D0:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45<\/jats:sub>\n                      \u2009=\u2009\u20130.01\u2009\u00b1\u20090.01 D, D90:\n                      <jats:italic>J<\/jats:italic>\n                      <jats:sub>45\u2009<\/jats:sub>\n                      =\u2009\u20130.01\u2009\u00b1\u20090.01 D;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.9), without significant effects of time, group, or their interaction.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec006\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The Hydrus Microstent is neutral in refractive astigmatism when used as a stand-alone procedure. In contrast, combined implantation with phacoemulsification can induce changes in refractive astigmatism. Keratometry analysis confirmed that both anterior and posterior corneal astigmatism remain stable, indicating that refractive changes are likely due to internal factors associated with lens exchange rather than the stent itself. Therefore, when implanted alone, the Hydrus Microstent is unlikely to compromise the results of prior refractive treatments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0340377","type":"journal-article","created":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T18:27:06Z","timestamp":1767896826000},"page":"e0340377","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":2,"title":["Short-term refractive and corneal astigmatism after canal-based microinvasive glaucoma surgery"],"prefix":"10.1371","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6746-3681","authenticated-orcid":true,"given":"Colya N.","family":"Englisch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0277-2525","authenticated-orcid":true,"given":"Karl T.","family":"Boden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9","family":"Messias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp K.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-0997-6151","authenticated-orcid":true,"given":"Andr\u00e9 M.","family":"Trouvain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9636-7346","authenticated-orcid":true,"given":"Peter","family":"Szurman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Langenbucher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3587-6382","authenticated-orcid":true,"given":"Philip","family":"Wakili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2026,1,8]]},"reference":[{"issue":"2","key":"pone.0340377.ref001","article-title":"Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: the Right to Sight: an analysis for the Global Burden of Disease Study","volume":"9","author":"GBD 2019 Blindness and Vision Impairment Collaborators, Vision Loss Expert Group of the Global Burden of Disease Study","year":"2021","journal-title":"Lancet Glob Health"},{"key":"pone.0340377.ref002","doi-asserted-by":"crossref","first-page":"16067","DOI":"10.1038\/nrdp.2016.67","article-title":"Primary open-angle glaucoma","volume":"2","author":"RN Weinreb","year":"2016","journal-title":"Nat Rev Dis Primers"},{"issue":"6","key":"pone.0340377.ref003","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1097\/APO.0000000000000646","article-title":"Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges","volume":"12","author":"PPM Chan","year":"2023","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"2","key":"pone.0340377.ref004","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1111\/ceo.14028","article-title":"The surgical management of glaucoma: A review","volume":"50","author":"R Lim","year":"2022","journal-title":"Clin Exp Ophthalmol"},{"issue":"5","key":"pone.0340377.ref005","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.survophthal.2020.09.005","article-title":"Microinvasive glaucoma surgery: A review of 3476 eyes","volume":"66","author":"P Nichani","year":"2021","journal-title":"Surv Ophthalmol"},{"key":"pone.0340377.ref006","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/bs.pmbts.2015.06.007","article-title":"Intraocular Pressure and the Mechanisms Involved in Resistance of the Aqueous Humor Flow in the Trabecular Meshwork Outflow Pathways","volume":"134","author":"ER Tamm","year":"2015","journal-title":"Prog Mol Biol Transl Sci"},{"issue":"3","key":"pone.0340377.ref007","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1167\/iovs.12-11373","article-title":"A novel 8-mm Schlemm\u2019s canal scaffold reduces outflow resistance in a human anterior segment perfusion model","volume":"54","author":"V Gulati","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"10","key":"pone.0340377.ref008","doi-asserted-by":"crossref","first-page":"6115","DOI":"10.1167\/iovs.12-9570","article-title":"A novel Schlemm\u2019s Canal scaffold increases outflow facility in a human anterior segment perfusion model","volume":"53","author":"LJ Camras","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"pone.0340377.ref009","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.ophtha.2019.04.034","article-title":"A Prospective Randomized Trial Comparing Hydrus and iStent Microinvasive Glaucoma Surgery Implants for Standalone Treatment of Open-Angle Glaucoma: The COMPARE Study","volume":"127","author":"IIK Ahmed","year":"2020","journal-title":"Ophthalmology"},{"issue":"1","key":"pone.0340377.ref010","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.ophtha.2018.05.012","article-title":"A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract: The HORIZON Study","volume":"126","author":"TW Samuelson","year":"2019","journal-title":"Ophthalmology"},{"key":"pone.0340377.ref011","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/j.exer.2016.01.008","article-title":"Variations in active outflow along the trabecular outflow pathway","volume":"146","author":"EDK Cha","year":"2016","journal-title":"Exp Eye Res"},{"issue":"7","key":"pone.0340377.ref012","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.jcrs.2017.04.039","article-title":"Evaluation of a Schlemm canal scaffold microstent combined with phacoemulsification in routine clinical practice: Two-year multicenter study","volume":"43","author":"AM Fea","year":"2017","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"pone.0340377.ref013","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.ophtha.2015.03.031","article-title":"A Randomized Trial of a Schlemm\u2019s Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma","volume":"122","author":"N Pfeiffer","year":"2015","journal-title":"Ophthalmology"},{"issue":"2","key":"pone.0340377.ref014","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1111\/ceo.12805","article-title":"Hydrus microstent compared to selective laser trabeculoplasty in primary open angle glaucoma: one year results","volume":"45","author":"AM Fea","year":"2017","journal-title":"Clin Exp Ophthalmol"},{"issue":"6","key":"pone.0340377.ref015","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1097\/IJG.0000000000000012","article-title":"A Novel Schlemm\u2019s Canal Scaffold: Histologic Observations","volume":"24","author":"I Grierson","year":"2015","journal-title":"J Glaucoma"},{"key":"pone.0340377.ref016","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.exer.2013.12.011","article-title":"Effects of a Schlemm canal scaffold on collector channel ostia in human anterior segments","volume":"119","author":"MA Johnstone","year":"2014","journal-title":"Exp Eye Res"},{"issue":"1","key":"pone.0340377.ref017","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S0886-3350(00)00797-5","article-title":"Power vector analysis of the optical outcome of refractive surgery","volume":"27","author":"LN Thibos","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"pone.0340377.ref018","doi-asserted-by":"crossref","first-page":"2113","DOI":"10.2147\/OPTH.S152612","article-title":"Comparison of surgically induced astigmatism following different glaucoma operations","volume":"11","author":"M Tanito","year":"2017","journal-title":"Clin Ophthalmol"},{"issue":"5","key":"pone.0340377.ref019","doi-asserted-by":"crossref","DOI":"10.1111\/aos.15042","article-title":"Comparison of subconjunctival microinvasive glaucoma surgery and trabeculectomy","volume":"100","author":"FM Wagner","year":"2022","journal-title":"Acta Ophthalmol"},{"issue":"9","key":"pone.0340377.ref020","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1097\/j.jcrs.0000000000001470","article-title":"Long-term astigmatism after intraocular pressure sensor implantation and nonpenetrating glaucoma surgery: EYEMATE-SC trial","volume":"50","author":"CN Englisch","year":"2024","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0340377.ref021","doi-asserted-by":"crossref","DOI":"10.1097\/IJG.0b013e31829f9c31","article-title":"Time course of induced astigmatism after canaloplasty","volume":"23","author":"MC Moelle","year":"2014","journal-title":"J Glaucoma"},{"issue":"3","key":"pone.0340377.ref022","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.ophtha.2022.09.021","article-title":"EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure","volume":"130","author":"P Szurman","year":"2023","journal-title":"Ophthalmology"},{"issue":"4","key":"pone.0340377.ref023","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1136\/bjophthalmol-2021-320023","article-title":"Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial","volume":"107","author":"P Szurman","year":"2023","journal-title":"Br J Ophthalmol"},{"key":"pone.0340377.ref024","article-title":"Intraocular Pressure Fluctuations Recorded by a Telemetric Sensor after Nonpenetrating Glaucoma Surgery in Primary Open-Angle Glaucoma","author":"CN Englisch","year":"2025","journal-title":"Ophthalmol Glaucoma"},{"issue":"6","key":"pone.0340377.ref025","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.jcrs.2003.11.034","article-title":"Surgically induced astigmatism after superotemporal and superonasal clear corneal incisions in phacoemulsification","volume":"30","author":"SS Ermi\u015f","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"pone.0340377.ref026","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/S0886-3350(13)80532-9","article-title":"Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes","volume":"21","author":"T Kohnen","year":"1995","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0340377.ref027","first-page":"68","article-title":"Clinical evaluation of surgery-induced astigmatism in cataract surgery using 2.2 mm or 1.8 mm clear corneal micro-incisions","volume":"10","author":"J Yang","year":"2017","journal-title":"Int J Ophthalmol"},{"issue":"3","key":"pone.0340377.ref028","first-page":"399","article-title":"A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery","volume":"9","author":"Y-B Yu","year":"2016","journal-title":"Int J Ophthalmol"},{"issue":"4","key":"pone.0340377.ref029","doi-asserted-by":"crossref","first-page":"244","DOI":"10.3928\/1081597X-20150319-04","article-title":"Surgically induced astigmatism assessment: comparison between three corneal measuring devices","volume":"31","author":"S Ofir","year":"2015","journal-title":"J Refract Surg"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0340377","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T18:27:10Z","timestamp":1767896830000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0340377"}},"subtitle":[],"editor":[{"given":"Nader Hussien Lotfy","family":"Bayoumi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,1,8]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1,8]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0340377","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,8]]}}}