{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T18:29:10Z","timestamp":1775586550635,"version":"3.50.1"},"reference-count":28,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T00:00:00Z","timestamp":1775520000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007830","name":"Kitasato University","doi-asserted-by":"publisher","award":["1070111602"],"award-info":[{"award-number":["1070111602"]}],"id":[{"id":"10.13039\/501100007830","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>To achieve positive refractive power, implantable collamer lenses (ICLs) for hyperopia increase central thickness, which in turn raises the risk of pupil blockage and lens contact in eyes with shallow anterior chambers. Additionally, incorporating a central hole raises concerns about stray light and halo formation due to increased thickness. This study used optical simulation to evaluate the imaging performance of hyperopic ICLs, highlighting the Fresnel structure\u2019s potential to reduce thickness while maintaining imaging performance. Optical simulations were performed using Ansys Zemax OpticStudio 2024 R2 (Ansys, Inc.). An ICL with +10.00 D correction was designed for the Liou &amp; Brennan model eye. The vault was set to 0.50\u2009mm, and the central hole diameter was set to 0.36\u2009mm. Fresnel ICLs (Fr. ICLs) with step heights ranging from 25 to 100 \u00b5m were compared with the reference ICL (Ref. ICL). Modulation transfer function (MTF) analyses were performed at internal artificial pupil diameters of 3.00\u2009mm and 4.50\u2009mm, both with and without holes. By reducing the central thickness from 0.80\u2009mm to 0.40\u2009mm, the Fr. ICL for hyperopia showed higher MTF values than the Ref. ICL at both pupil diameters. The difference was particularly significant at 4.50\u2009mm. A slight MTF decrease due to the central hole was observed at 3.00\u2009mm internal artificial pupil diameter. A step height of 50 \u00b5m or more suppressed contrast reduction at high spatial frequencies. Although further research is needed in illumination optics and clinical studies, ray-tracing simulations have demonstrated that the designed hyperopia-correcting Fr. ICL can reduce central thickness while maintaining or improving optical performance, making it a promising candidate for clinical application.<\/jats:p>","DOI":"10.1371\/journal.pone.0345116","type":"journal-article","created":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T17:39:23Z","timestamp":1775583563000},"page":"e0345116","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis"],"prefix":"10.1371","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5833-5602","authenticated-orcid":true,"given":"Kimiya","family":"Shimizu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3759-0775","authenticated-orcid":true,"given":"Takushi","family":"Kawamorita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2026,4,7]]},"reference":[{"key":"pone.0345116.ref001","doi-asserted-by":"crossref","first-page":"69","DOI":"10.2147\/OPTH.S440578","article-title":"A Comprehensive retrospective analysis of EVO\/EVO+ implantable collamer lens: evaluating refractive outcomes in the largest single center study of ICL patients in the United States","volume":"18","author":"C Albo","year":"2024","journal-title":"Clin Ophthalmol"},{"key":"pone.0345116.ref002","doi-asserted-by":"crossref","DOI":"10.3389\/fmed.2021.799078","article-title":"Eight-year outcomes of implantation of posterior chamber phakic intraocular lens with a central port for moderate to high ametropia","volume":"8","author":"K Kamiya","year":"2021","journal-title":"Front Med"},{"issue":"14","key":"pone.0345116.ref003","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000003270","article-title":"Long-term comparison of posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation for moderate to high myopia and myopic astigmatism: consort-compliant article","volume":"95","author":"K Shimizu","year":"2016","journal-title":"Medicine (Baltimore)"},{"issue":"7","key":"pone.0345116.ref004","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1007\/s00417-010-1602-8","article-title":"Modulation transfer function of intraocular collamer lens with a central artificial hole","volume":"249","author":"H Uozato","year":"2011","journal-title":"Graefe\u2019s Arch Clin Exp Ophthalmol = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie"},{"issue":"4","key":"pone.0345116.ref005","doi-asserted-by":"crossref","first-page":"437","DOI":"10.4103\/0301-4738.119423","article-title":"Optical quality of hyperopic and myopic phakic intraocular lenses","volume":"62","author":"C P\u00e9rez-Vives","year":"2014","journal-title":"Indian J Ophthalmol"},{"issue":"9","key":"pone.0345116.ref006","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/j.jcrs.2007.05.030","article-title":"Posterior chamber phakic intraocular lens (ICL) for hyperopia: ten-year follow-up","volume":"33","author":"PM Pesando","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"pone.0345116.ref007","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.jcrs.2008.10.039","article-title":"Phakic intraocular lens for the correction of hyperopia","volume":"35","author":"A Koivula","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0345116.ref008","doi-asserted-by":"crossref","first-page":"59","DOI":"10.4103\/ojo.ojo_295_22","article-title":"The prevalence of functional amblyopia and its related risk factors in preschool children in North-Eastern Iran","volume":"17","author":"A Hamidi","year":"2024","journal-title":"Oman J Ophthalmol"},{"issue":"3","key":"pone.0345116.ref009","doi-asserted-by":"crossref","first-page":"804","DOI":"10.4103\/IJO.IJO_2567_22","article-title":"A clinical trial on phakic intraocular lens for the treatment of refractive amblyopia in children and adolescents","volume":"71","author":"AK Morya","year":"2023","journal-title":"Indian J Ophthalmol"},{"issue":"1","key":"pone.0345116.ref010","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s40123-013-0013-4","article-title":"The role of phakic intraocular lens implants in treatment of high-refractive errors and amblyopia in children","volume":"2","author":"S Moran","year":"2013","journal-title":"Ophthalmol Ther"},{"issue":"5","key":"pone.0345116.ref011","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1007\/s40123-022-00540-9","article-title":"Digital eye strain- a comprehensive review","volume":"11","author":"K Kaur","year":"2022","journal-title":"Ophthalmol Ther"},{"issue":"3","key":"pone.0345116.ref012","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajo.2012.04.001","article-title":"Intraindividual comparison of visual performance after posterior chamber phakic intraocular lens with and without a central hole implantation for moderate to high myopia","volume":"154","author":"K Shimizu","year":"2012","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"pone.0345116.ref013","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1038\/eye.2016.279","article-title":"Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics","volume":"31","author":"T Kawamorita","year":"2017","journal-title":"Eye (Lond)"},{"issue":"4","key":"pone.0345116.ref014","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1007\/s00417-016-3304-3","article-title":"Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics","volume":"254","author":"T Kawamorita","year":"2016","journal-title":"Graefe\u2019s Arch Clin Exp Ophthalmol"},{"issue":"11","key":"pone.0345116.ref015","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1001\/jamaophthalmol.2022.3667","article-title":"Visual outcomes and optical quality of accommodative, multifocal, extended depth-of-focus, and monofocal intraocular lenses in presbyopia-correcting cataract surgery: a systematic review and Bayesian network meta-analysis","volume":"140","author":"J-Y Cho","year":"2022","journal-title":"JAMA Ophthalmol"},{"key":"pone.0345116.ref016","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.2147\/OPTH.S271858","article-title":"Performance and Safety of the Extended Depth of Focus Implantable Collamer(\u00ae) Lens (EDOF ICL) in Phakic Subjects with Presbyopia","volume":"14","author":"M Packer","year":"2020","journal-title":"Clin Ophthalmol (Auckland, NZ)"},{"issue":"1","key":"pone.0345116.ref017","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1364\/BOE.544647","article-title":"Design concepts for advanced-technology intraocular lenses [Invited]","volume":"16","author":"MJ Simpson","year":"2024","journal-title":"Biomed Opt Express"},{"issue":"5","key":"pone.0345116.ref018","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1007\/s00417-007-0759-2","article-title":"Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole","volume":"246","author":"T Shiratani","year":"2008","journal-title":"Graefe\u2019s Arch Clin Exp Ophthalmol"},{"issue":"8","key":"pone.0345116.ref019","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1364\/JOSAA.14.001684","article-title":"Anatomically accurate, finite model eye for optical modeling","volume":"14","author":"HL Liou","year":"1997","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"pone.0345116.ref020","unstructured":"International Organization for Standardization, ISO 11979-2:2024 Ophthalmic implants \u2014 Intraocular lenses Part 2: Optical properties and test methods (2024). [cited 2026 Feb 3] https:\/\/www.iso.org\/standard\/86607.html"},{"issue":"26","key":"pone.0345116.ref021","doi-asserted-by":"crossref","first-page":"6595","DOI":"10.1364\/AO.46.006595","article-title":"Model eyes for evaluation of intraocular lenses","volume":"46","author":"S Norrby","year":"2007","journal-title":"Appl Opt"},{"issue":"5","key":"pone.0345116.ref022","doi-asserted-by":"crossref","first-page":"378","DOI":"10.3928\/1081597X-20100212-01","article-title":"Effect of pupil size on visual acuity in a laboratory model of pseudophakic monovision","volume":"26","author":"T Kawamorita","year":"2010","journal-title":"J Refract Surg"},{"issue":"10","key":"pone.0345116.ref023","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1016\/j.ophtha.2021.03.013","article-title":"Multifocal and Accommodating Intraocular Lenses for the Treatment of Presbyopia: A Report by the American Academy of Ophthalmology","volume":"128","author":"JM Schallhorn","year":"2021","journal-title":"Ophthalmology"},{"issue":"16","key":"pone.0345116.ref024","doi-asserted-by":"crossref","first-page":"2831","DOI":"10.1364\/AO.25.002831","article-title":"A \u201ctuned\u201d Fresnel lens","volume":"25","author":"G Vannucci","year":"1986","journal-title":"Appl Opt"},{"key":"pone.0345116.ref025","article-title":"Aniseikonia","volume-title":"StatPearls","author":"TJ Stokkermans","year":"2025"},{"issue":"9","key":"pone.0345116.ref026","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1097\/OPX.0000000000000893","article-title":"The effects of age, refractive status, and luminance on pupil size","volume":"93","author":"M Guillon","year":"2016","journal-title":"Optom Vis Sci"},{"key":"pone.0345116.ref027","first-page":"9520512","article-title":"Distribution of pupil size and associated factors: results from the population-based Gutenberg Health Study","volume":"2022","author":"M Kiel","year":"2022","journal-title":"J Ophthalmol"},{"issue":"6","key":"pone.0345116.ref028","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0066846","article-title":"Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument","volume":"8","author":"K Kamiya","year":"2013","journal-title":"PLoS One"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0345116","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T17:39:28Z","timestamp":1775583568000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0345116"}},"subtitle":[],"editor":[{"given":"Amit Kumar","family":"Goyal","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2026,4,7]]},"references-count":28,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4,7]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0345116","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,7]]}}}