{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T18:47:38Z","timestamp":1775155658863,"version":"3.50.1"},"reference-count":33,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:00:00Z","timestamp":1775088000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Beijing Municipal Science and Technology Plan Project","award":["Z241100007724002"],"award-info":[{"award-number":["Z241100007724002"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>Spinal cord stimulation (SCS) is widely used to treat various types of pain. Directional leads, which exhibit directional focusing properties, have been applied in deep brain stimulation. Their targeting capability holds potential for further enhancing clinical SCS protocols. However, the actual stimulation effects of directional leads remain unclear and require further investigation. This study employed a computational modelling approach to develop SCS simulation models and a multi-compartment cable model of sensory fibers. These models were used to simulate the stimulation effects of directional leads in the human spinal cord. According to the reciprocity theorem, the evoked compound action potential (ECAP) generated by activated nerve fibers at recording contacts was calculated. Compared to traditional percutaneous leads, directional leads produced higher electric field strength and activating function in the spinal cord under the same current intensity, thereby activating a greater number of nerve fibers. Furthermore, increasing the angle between contacts further enhanced the advantages of directional leads. When the directional lead was rotated, the stimulation direction deviated from directly facing the spinal cord, resulting in a decreased number of activated nerve fibers. Under identical stimulation conditions, ECAP amplitudes recorded at different directional contacts showed variation; however, these differences remained within 6%. This study demonstrated the directional focusing advantage of directional leads and compared ECAP outcomes under varying conditions. The findings provide a solid theoretical foundation for the clinical application of directional leads.<\/jats:p>","DOI":"10.1371\/journal.pone.0345287","type":"journal-article","created":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T17:46:57Z","timestamp":1775152017000},"page":"e0345287","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Directional leads applied to spinal cord stimulation: A computational modelling study"],"prefix":"10.1371","volume":"21","author":[{"given":"Zhen","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nianshuang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Penghao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changzhe","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolin","family":"Huo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6445-2271","authenticated-orcid":true,"given":"Guanghao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2026,4,2]]},"reference":[{"issue":"2","key":"pone.0345287.ref001","doi-asserted-by":"crossref","first-page":"185","DOI":"10.3390\/bioengineering10020185","article-title":"Advances in Spinal Cord Stimulation","volume":"10","author":"CM Lam","year":"2023","journal-title":"Bioengineering"},{"key":"pone.0345287.ref002","doi-asserted-by":"crossref","first-page":"651","DOI":"10.2147\/JPR.S37589","article-title":"Spinal cord stimulation for neuropathic pain: current perspectives","volume":"7","author":"T Wolter","year":"2014","journal-title":"J Pain Res"},{"key":"pone.0345287.ref003","first-page":"5607898","article-title":"Spinal Cord Stimulation and Treatment of Peripheral or Central Neuropathic Pain: Mechanisms and Clinical Application","volume":"2021","author":"L Sun","year":"2021","journal-title":"Neural Plast"},{"issue":"3699","key":"pone.0345287.ref004","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1126\/science.150.3699.971","article-title":"Pain mechanisms: a new theory","volume":"150","author":"R Melzack","year":"1965","journal-title":"Science"},{"issue":"1","key":"pone.0345287.ref005","article-title":"Spinal cord stimulation in chronic neuropathic pain: mechanisms of action, new locations, new paradigms","author":"EA Joosten","year":"2020","journal-title":"Pain"},{"issue":"1","key":"pone.0345287.ref006","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1227\/neu.0000000000002654","article-title":"History and Future of Spinal Cord Stimulation","volume":"94","author":"R Ali","year":"2024","journal-title":"Neurosurgery"},{"issue":"5","key":"pone.0345287.ref007","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1111\/papr.12644","article-title":"Utilization of Leads After Permanent Implant in Spinal Cord Stimulator Systems","volume":"18","author":"RA Sanders","year":"2018","journal-title":"Pain Pract"},{"key":"pone.0345287.ref008","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1111\/j.1525-1403.2011.00407.x","article-title":"Improving Patient Experience with Spinal Cord Stimulation: Implications of Position-Related Changes in Neurostimulation","volume":"17","author":"E Ross","year":"2014","journal-title":"Neuromodulation: Technology at the Neural Interface"},{"issue":"2","key":"pone.0345287.ref009","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1111\/j.1525-1403.2005.00224.x","article-title":"Technical performance of percutaneous leads for spinal cord stimulation: a modeling study","volume":"8","author":"L Manola","year":"2005","journal-title":"Neuromodulation"},{"key":"pone.0345287.ref010","doi-asserted-by":"crossref","first-page":"825178","DOI":"10.3389\/fneur.2022.825178","article-title":"Past, present, and future of deep brain stimulation: hardware, software, imaging, physiology and novel approaches","volume":"13","author":"J Frey","year":"2022","journal-title":"Front Neurol"},{"issue":"1","key":"pone.0345287.ref011","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1111\/ner.12968","article-title":"Evoked Compound Action Potentials Reveal Spinal Cord Dorsal Column Neuroanatomy","volume":"23","author":"JL Parker","year":"2020","journal-title":"Neuromodulation"},{"issue":"1","key":"pone.0345287.ref012","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/ner.13480","article-title":"Electrically Evoked Compound Action Potentials in Spinal Cord Stimulation: Implications for Preclinical Research Models","volume":"25","author":"BE Dietz","year":"2022","journal-title":"Neuromodulation"},{"issue":"6","key":"pone.0345287.ref013","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1111\/papr.13008","article-title":"ECAP-Controlled Closed-Loop Spinal Cord Stimulation Efficacy and Opioid Reduction Over 24-Months: Final Results of the Prospective, Multicenter, Open-Label Avalon Study","volume":"21","author":"C Brooker","year":"2021","journal-title":"Pain Pract"},{"issue":"2","key":"pone.0345287.ref014","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/S1474-4422(19)30414-4","article-title":"Long-term safety and efficacy of closed-loop spinal cord stimulation to treat chronic back and leg pain (Evoke): a double-blind, randomised, controlled trial","volume":"19","author":"N Mekhail","year":"2020","journal-title":"Lancet Neurol"},{"issue":"1","key":"pone.0345287.ref015","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/ner.12965","article-title":"Evoked Potentials Recorded From the Spinal Cord During Neurostimulation for Pain: A Computational Modeling Study","volume":"23","author":"CJ Anaya","year":"2020","journal-title":"Neuromodulation"},{"issue":"3","key":"pone.0345287.ref016","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1111\/ner.12909","article-title":"Computational Study of the Effect of Electrode Polarity on Neural Activation Related to Paresthesia Coverage in Spinal Cord Stimulation Therapy","volume":"22","author":"JL Dur\u00e1","year":"2019","journal-title":"Neuromodulation"},{"key":"pone.0345287.ref017","first-page":"6555","article-title":"A model of evoked potentials in spinal cord stimulation","volume":"2013","author":"JH Laird","year":"2013","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"2","key":"pone.0345287.ref018","doi-asserted-by":"crossref","DOI":"10.1088\/1741-2552\/adbfbe","article-title":"Feature extraction and prediction of spinal cord stimulation evoked compound action potentials in humans","volume":"22","author":"S K\u00f6nig","year":"2025","journal-title":"J Neural Eng"},{"issue":"5","key":"pone.0345287.ref019","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1016\/j.neurom.2022.03.007","article-title":"Spatiotemporal Distribution of Electrically Evoked Spinal Compound Action Potentials During Spinal Cord Stimulation","volume":"26","author":"JS Calvert","year":"2023","journal-title":"Neuromodulation"},{"issue":"1","key":"pone.0345287.ref020","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s42234-023-00106-5","article-title":"Characterization and applications of evoked responses during epidural electrical stimulation","volume":"9","author":"N Verma","year":"2023","journal-title":"Bioelectron Med"},{"issue":"4","key":"pone.0345287.ref021","article-title":"Evoked compound action potentials during spinal cord stimulation: effects of posture and pulse width on signal features and neural activation within the spinal cord","volume":"20","author":"MK Brucker-Hahn","year":"2023","journal-title":"J Neural Eng"},{"issue":"11","key":"pone.0345287.ref022","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1097\/00007632-199606010-00001","article-title":"Morphologic features of the normal human cadaveric spinal cord","volume":"21","author":"T Kameyama","year":"1996","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"pone.0345287.ref023","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0000000000000125","article-title":"Morphometrics of the entire human spinal cord and spinal canal measured from in vivo high-resolution anatomical magnetic resonance imaging","volume":"39","author":"L Fradet","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"pone.0345287.ref024","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.jbiomech.2005.11.014","article-title":"Biomechanics of vertebral level, geometry, and transcortical tumors in the metastatic spine","volume":"40","author":"CE Tschirhart","year":"2007","journal-title":"J Biomech"},{"issue":"3","key":"pone.0345287.ref025","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1111\/j.1469-7580.2011.01397.x","article-title":"Morphometric analysis of the relationships between intervertebral disc and vertebral body heights: an anatomical and radiographic study of the human thoracic spine","volume":"219","author":"ME Kunkel","year":"2011","journal-title":"J Anat"},{"issue":"3","key":"pone.0345287.ref026","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.pain.2011.11.023","article-title":"Compound action potentials recorded in the human spinal cord during neurostimulation for pain relief","volume":"153","author":"JL Parker","year":"2012","journal-title":"Pain"},{"issue":"1","key":"pone.0345287.ref027","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/BF02368219","article-title":"Electrical properties of implant encapsulation tissue","volume":"22","author":"WM Grill","year":"1994","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"pone.0345287.ref028","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1152\/jn.00353.2001","article-title":"Modeling the excitability of mammalian nerve fibers: influence of afterpotentials on the recovery cycle","volume":"87","author":"CC McIntyre","year":"2002","journal-title":"J Neurophysiol"},{"key":"pone.0345287.ref029","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1093\/brain\/awf111","article-title":"Morphometry of human superficial dorsal and dorsolateral column fibres: significance to spinal cord stimulation","volume":"125","author":"HKP Feirabend","year":"2002","journal-title":"Brain"},{"issue":"1","key":"pone.0345287.ref030","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s10827-018-0689-5","article-title":"A model of motor and sensory axon activation in the median nerve using surface electrical stimulation","volume":"45","author":"JL Gaines","year":"2018","journal-title":"J Comput Neurosci"},{"key":"pone.0345287.ref031","article-title":"BlueRecording: A pipeline for the efficient calculation of extracellular recordings in large-scale neural circuit models","author":"JJ Tharayil","year":"2024","journal-title":"bioRxiv"},{"issue":"7","key":"pone.0345287.ref032","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1109\/10.32099","article-title":"Analysis of models for extracellular fiber stimulation","volume":"36","author":"F Rattay","year":"1989","journal-title":"IEEE Trans Biomed Eng"},{"issue":"12","key":"pone.0345287.ref033","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0114938","article-title":"Evaluation of intradural stimulation efficiency and selectivity in a computational model of spinal cord stimulation","volume":"9","author":"B Howell","year":"2014","journal-title":"PLoS One"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0345287","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T17:47:02Z","timestamp":1775152022000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0345287"}},"subtitle":[],"editor":[{"given":"Haipeng","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2026,4,2]]},"references-count":33,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4,2]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0345287","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,2]]}}}