{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T18:09:16Z","timestamp":1779300556634,"version":"3.51.4"},"reference-count":21,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:00:00Z","timestamp":1779235200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to investigate the relationship between high intraocular pressure (IOP) effect on axial length (AL) and postoperative refractive error after cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective study was conducted on cases that underwent cataract surgery for elevated IOP. AL was corrected based on the change in AL per 1 mmHg of IOP, and the predicted refractive error was evaluated at 3 months postoperatively. Preoperative and postoperative optical biometry was performed using the segmented refractive index method. Intraocular lens (IOL) power was calculated using both the SRK\/T and Barrett Universal II (BU II) formulas.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Optical biometry was obtained in 18 cases and 19 eyes before and after cataract surgery. A moderate correlation was observed between the change in IOP and AL (r\u2009=\u20090.687, P\u2009=\u20090.0012), with the change in AL per 1 mmHg of reduction in IOP calculated as 0.005 mm. The mean change in IOP was 38.87\u2009\u00b1\u200910.80 mmHg (P\u2009=\u20090.001), and the AL \\ significantly shortened by 0.18\u2009\u00b1\u20090.09 mm (P\u2009=\u20090.001). The mean postoperative refractive errors were 0.36\u2009\u00b1\u20090.59 D with the SRK\/T formula, 0.79\u2009\u00b1\u20090.58 D with the BU II formula, showing significantly more hyperopia (p\u2009=\u20090.001). After AL correction, the predicted refractive error was reduced to \u22120.08\u2009\u00b1\u20090.54 D (SRK\/T) and 0.27\u2009\u00b1\u20090.55 D (BU II).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In cataract surgery for eyes with elevated IOP, using corrected AL based on the anticipated IOP reduction appears to decrease the predicted refractive error. Additionally, it should be noted that the BU II formula may result in a hyperopic shift in refractive prediction error, even when using the adjusted AL.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0349117","type":"journal-article","created":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T17:35:25Z","timestamp":1779298525000},"page":"e0349117","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of axial length correction in high intraocular pressure eyes on intraocular lens power calculation"],"prefix":"10.1371","volume":"21","author":[{"given":"Yuri","family":"Kosaka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5016-0155","authenticated-orcid":true,"given":"Takashi","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2153-9956","authenticated-orcid":true,"given":"Akeno","family":"Tamaoki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Takagi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayako","family":"Sawaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsuyoshi","family":"Nogami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsushi","family":"Kaga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2026,5,20]]},"reference":[{"key":"pone.0349117.ref001","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10384-022-00970-9","article-title":"Glaucoma Guideline Preparation Committee, Japan Glaucoma Society. The Japan Glaucoma Society guidelines for glaucoma 5th edition","volume":"67","author":"Y Kiuchi","year":"2023","journal-title":"Jpn J Ophthalmol"},{"issue":"2","key":"pone.0349117.ref002","doi-asserted-by":"crossref","first-page":"660","DOI":"10.3390\/jcm12020660","article-title":"Safety and efficacy of rapid primary phacoemulsification on acute primary angle closure with and without preoperative IOP-lowering medication","volume":"12","author":"T Suzuki","year":"2023","journal-title":"J Clin Med"},{"issue":"7","key":"pone.0349117.ref003","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1097\/j.jcrs.0000000000001447","article-title":"Effects of reduction in intraocular pressure after trabeculotomy on axial length and intraocular lens selection","volume":"50","author":"S Kanda","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"pone.0349117.ref004","article-title":"Changes in Axial Length and Refractive Error After Noninvasive Normalization of Intraocular Pressure From Elevated Levels","volume":"163","author":"C-S Kim","year":"2016","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"pone.0349117.ref005","doi-asserted-by":"crossref","first-page":"13283","DOI":"10.1038\/s41598-023-40585-9","article-title":"Refractive outcomes after immediate primary phacoemulsification for acute primary angle closure","volume":"13","author":"T Suzuki","year":"2023","journal-title":"Sci Rep"},{"issue":"5","key":"pone.0349117.ref006","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1097\/j.jcrs.0000000000000149","article-title":"Change in optical axial length after cataract surgery: segmental method vs composite method","volume":"46","author":"S Goto","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"pone.0349117.ref007","article-title":"Comparison of accuracy and axial length acquisition success rate by three types of swept-source OCT-based biometers","author":"Y Kato","year":"2024","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0349117.ref008","doi-asserted-by":"crossref","first-page":"32","DOI":"10.4274\/tjo.galenos.2023.82453","article-title":"The Effects of Lens Extraction Surgery on Intraocular Pressure and Anterior Segment Parameters in Primary Angle-Closure Glaucoma","volume":"54","author":"S Bayraktar","year":"2024","journal-title":"Turk J Ophthalmol"},{"issue":"9","key":"pone.0349117.ref009","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1038\/eye.2013.127","article-title":"The biometric study in different stages of primary angle-closure glaucoma","volume":"27","author":"Y-Y Chen","year":"2013","journal-title":"Eye (Lond)"},{"issue":"3","key":"pone.0349117.ref010","doi-asserted-by":"crossref","first-page":"86","DOI":"10.5005\/jp-journals-10028-1230","article-title":"Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy","volume":"11","author":"T Mansoori","year":"2017","journal-title":"J Curr Glaucoma Pract"},{"issue":"1","key":"pone.0349117.ref011","first-page":"17","article-title":"Ocular biometry in angle closure","volume":"8","author":"MR Razeghinejad","year":"2013","journal-title":"J Ophthalmic Vis Res"},{"issue":"1","key":"pone.0349117.ref012","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1136\/bjo.2004.043950","article-title":"Changes in axial length following trabeculectomy and glaucoma drainage device surgery","volume":"89","author":"BA Francis","year":"2005","journal-title":"Br J Ophthalmol"},{"issue":"8","key":"pone.0349117.ref013","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1038\/eye.2013.116","article-title":"Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery","volume":"27","author":"N Kara","year":"2013","journal-title":"Eye (Lond)"},{"issue":"6","key":"pone.0349117.ref014","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1007\/s10384-012-0173-0","article-title":"Changes in choroidal thickness and optical axial length accompanying intraocular pressure increase","volume":"56","author":"M Hata","year":"2012","journal-title":"Jpn J Ophthalmol"},{"issue":"8","key":"pone.0349117.ref015","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1097\/IJG.0000000000001527","article-title":"Intraocular Pressure Reduction After Real-world Cataract Surgery","volume":"29","author":"I Leal","year":"2020","journal-title":"J Glaucoma"},{"issue":"11","key":"pone.0349117.ref016","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1097\/IJG.0000000000000530","article-title":"Changes in the Choroidal Thickness and Axial Length Upon Mannitol Infusion in Patients With Asymmetric Intraocular Pressure","volume":"25","author":"S \u00c7ali\u015fkan","year":"2016","journal-title":"J Glaucoma"},{"key":"pone.0349117.ref017","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.2147\/OPTH.S44884","article-title":"Changes in axial length and choroidal thickness after intraocular pressure reduction resulting from trabeculectomy","volume":"7","author":"S Usui","year":"2013","journal-title":"Clin Ophthalmol"},{"issue":"4","key":"pone.0349117.ref018","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1007\/s10792-013-9878-4","article-title":"Postoperative refractive error following cataract surgery after the first attack of acute primary angle closure","volume":"34","author":"T Nishide","year":"2014","journal-title":"Int Ophthalmol"},{"issue":"3","key":"pone.0349117.ref019","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1136\/bjophthalmol-2020-317822","article-title":"Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison","volume":"106","author":"D Hip\u00f3lito-Fernandes","year":"2022","journal-title":"Br J Ophthalmol"},{"issue":"2","key":"pone.0349117.ref020","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of Intraocular Lens Calculation Formulas","volume":"125","author":"RB Melles","year":"2018","journal-title":"Ophthalmology"},{"issue":"14","key":"pone.0349117.ref021","article-title":"The effects of peripheral anterior synechiae on refractive outcomes after cataract surgery in eyes with primary angle-closure disease","volume":"100","author":"T-E Lee","year":"2021","journal-title":"Medicine (Baltimore)"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0349117","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T17:35:30Z","timestamp":1779298530000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0349117"}},"subtitle":[],"editor":[{"given":"Nader Hussien Lotfy","family":"Bayoumi","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2026,5,20]]},"references-count":21,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5,20]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0349117","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,20]]}}}