{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T18:03:26Z","timestamp":1784570606878,"version":"3.55.0"},"reference-count":83,"publisher":"Public Library of Science (PLoS)","issue":"7","license":[{"start":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T00:00:00Z","timestamp":1784505600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      We performed a prospective study to assess the repeatability and reproducibility of the novel Brillouin Optical Scanning System (BOSS\n                      <jats:sup>\u00ae<\/jats:sup>\n                      ) in measuring the biomechanical properties of the cornea and crystalline lens in vivo, to determine device utility in a clinical setting.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Adult study participants underwent standard ophthalmic exams to confirm eligibility. At two separate visits to the clinic, monocular lens scans and corneal scans (one point and seven points, respectively) were performed three times on each of three BOSS devices, operated by different technicians. The measured Brillouin parameters per person included the lens stiffness and the stiffnesses (e.g., \u201cMean\u201d, \u201cMinimum\u201d) across the seven corneal points. Results were combined across participants to calculate the coefficients of variation (CVs) for repeatability (within each device) and reproducibility (across devices), along with the repeatability and reproducibility limits (2.8 times the respective standard deviations).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Eleven of the 33 participants (ages 24\u201372 years; 15 females) had keratoconus (5 with prior crosslinking, 3 without crosslinking, and 3 post-keratoplasty); the other 22 participants were visually normal. There were no adverse events. The average lens stiffness was 3.33\u2009\u00b1\u20090.052 GPa (mean\u2009\u00b1\u2009SD), with an overall repeatability CV of 1.6%, with values ranging from 3.35\u2009\u00b1\u20090.037 GPa with a CV of 1.1% to 3.30\u2009\u00b1\u20090.071 with a CV of 2.1% across the separate devices. The mean corneal stiffness was 2.83\u2009\u00b1\u20090.031 GPa, with an overall repeatability CV of 1.1%, ranging from 2.85\u2009\u00b1\u20090.015 with a CV of 0.5% to 2.81\u2009\u00b1\u20090.036 with a CV of 1.3% across devices. The reproducibility CVs were 2.1% and 1.6% for lenses and corneal Means, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The study results demonstrated consistent stiffness values for both lenses and corneas within and between the three BOSS devices tested. The study shows that this device could be a useful new biomechanics-measuring tool for applications in ophthalmology.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0353667","type":"journal-article","created":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T17:25:07Z","timestamp":1784568307000},"page":"e0353667","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Repeatability and reproducibility of a clinical device for Brillouin microscopy to measure the biomechanics of the anterior segment of the eye: In vivo tests"],"prefix":"10.1371","volume":"21","author":[{"given":"Hannah Pearl","family":"Glucksman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lawrence","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis Alberto","family":"Carvalho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-9205-270X","authenticated-orcid":true,"given":"Claire Shelley","family":"Barnes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2026,7,20]]},"reference":[{"key":"pone.0353667.ref001","doi-asserted-by":"crossref","first-page":"100140","DOI":"10.1016\/j.medntd.2022.100140","article-title":"Corneal and scleral biomechanics in ophthalmic diseases: An updated review","volume":"15","author":"Y Wang","year":"2022","journal-title":"Med Nov Technol Devices"},{"issue":"12","key":"pone.0353667.ref002","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.4103\/ijo.IJO_2146_20","article-title":"A review of corneal biomechanics: Mechanisms for measurement and the implications for refractive surgery","volume":"68","author":"A Wilson","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"pone.0353667.ref003","doi-asserted-by":"crossref","first-page":"103600","DOI":"10.1016\/j.jmbbm.2019.103600","article-title":"Biomechanical properties of the lens capsule: A review","volume":"103","author":"KS Avetisov","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"pone.0353667.ref004","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.preteyeres.2018.11.004","article-title":"Biomechanics of the human lens and accommodative system: Functional relevance to physiological states","volume":"71","author":"K Wang","year":"2019","journal-title":"Prog Retin Eye Res"},{"issue":"1","key":"pone.0353667.ref005","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s10792-024-03057-1","article-title":"Corneal biomechanics and diagnostics: a review","volume":"44","author":"MA Komninou","year":"2024","journal-title":"Int Ophthalmol"},{"issue":"3","key":"pone.0353667.ref006","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/IIO.0000000000000172","article-title":"Biomechanical diagnostics of the cornea","volume":"57","author":"VS De Stefano","year":"2017","journal-title":"Int Ophthalmol Clin"},{"issue":"1","key":"pone.0353667.ref007","doi-asserted-by":"crossref","first-page":"7467","DOI":"10.1038\/s41598-019-43811-5","article-title":"Spatially-resolved Brillouin spectroscopy reveals biomechanical abnormalities in mild to advanced keratoconus in vivo","volume":"9","author":"P Shao","year":"2019","journal-title":"Sci Rep"},{"issue":"6","key":"pone.0353667.ref008","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jcrs.2018.12.015","article-title":"Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer","volume":"45","author":"R Herber","year":"2019","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"pone.0353667.ref009","doi-asserted-by":"crossref","first-page":"016005","DOI":"10.1117\/1.3526701","article-title":"Method for optical coherence elastography of the cornea","volume":"16","author":"MR Ford","year":"2011","journal-title":"J Biomed Opt"},{"issue":"1","key":"pone.0353667.ref010","doi-asserted-by":"crossref","first-page":"6321","DOI":"10.1038\/s41598-019-42789-4","article-title":"Line-Field Optical Coherence Tomography as a tool for In vitro characterization of corneal biomechanics under physiological pressures","volume":"9","author":"A Kazaili","year":"2019","journal-title":"Sci Rep"},{"key":"pone.0353667.ref011","doi-asserted-by":"crossref","first-page":"107904","DOI":"10.1016\/j.exer.2019.107904","article-title":"Biomechanical contribution of the sclera to dynamic corneal response in air-puff induced deformation in human donor eyes","volume":"191","author":"BA Nguyen","year":"2020","journal-title":"Exp Eye Res"},{"issue":"8","key":"pone.0353667.ref012","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0104904","article-title":"Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation","volume":"9","author":"S Kling","year":"2014","journal-title":"PLoS One"},{"issue":"3","key":"pone.0353667.ref013","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1364\/BOE.3.000473","article-title":"Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas","volume":"3","author":"C Dorronsoro","year":"2012","journal-title":"Biomed Opt Express"},{"issue":"3","key":"pone.0353667.ref014","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1167\/tvst.14.3.22","article-title":"Regional biomechanical weakening in keratoconus corneas detected by in vivo high-frequency ultrasound elastography","volume":"14","author":"S Kwok","year":"2025","journal-title":"Transl Vis Sci Technol"},{"issue":"5","key":"pone.0353667.ref015","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1111\/j.1755-3768.1991.tb04857.x","article-title":"A clinical comparison of optical and ultrasonic pachometry","volume":"69","author":"J Nissen","year":"1991","journal-title":"Acta Ophthalmol (Copenh)"},{"issue":"1","key":"pone.0353667.ref016","doi-asserted-by":"crossref","first-page":"4","DOI":"10.4103\/2008-322X.156084","article-title":"Measurement of central corneal thickness using ultrasound pachymetry and Orbscan II in normal eyes","volume":"10","author":"MM Sadoughi","year":"2015","journal-title":"J Ophthalmic Vis Res"},{"key":"pone.0353667.ref017","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1038\/nphoton.2007.250","article-title":"Confocal Brillouin microscopy for three-dimensional mechanical imaging","volume":"2","author":"G Scarcelli","year":"2007","journal-title":"Nat Photonics"},{"issue":"1402","key":"pone.0353667.ref018","first-page":"341","article-title":"Brillouin scattering in systems of biological significance","volume":"293","author":"J Randall","year":"1979","journal-title":"Philos Transact A Math Phys Eng Sci"},{"issue":"5755","key":"pone.0353667.ref019","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1038\/284489a0","article-title":"Brillouin scattering, density and elastic properties of the lens and cornea of the eye","volume":"284","author":"JM Vaughan","year":"1980","journal-title":"Nature"},{"issue":"1197","key":"pone.0353667.ref020","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1098\/rspb.1982.0021","article-title":"The measurement and interpretation of Brillouin scattering in the lens of the eye","volume":"214","author":"J Randall","year":"1982","journal-title":"Proc R Soc Lond B Biol Sci"},{"issue":"1","key":"pone.0353667.ref021","doi-asserted-by":"crossref","first-page":"1354","DOI":"10.1038\/s41467-022-29038-5","article-title":"Measuring mechanical anisotropy of the cornea with Brillouin microscopy","volume":"13","author":"AM Eltony","year":"2022","journal-title":"Nat Commun"},{"issue":"8","key":"pone.0353667.ref022","doi-asserted-by":"crossref","first-page":"9197","DOI":"10.1364\/OE.20.009197","article-title":"In vivo Brillouin optical microscopy of the human eye","volume":"20","author":"G Scarcelli","year":"2012","journal-title":"Opt Express"},{"issue":"4","key":"pone.0353667.ref023","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1097\/ICU.0000000000000489","article-title":"Brillouin microscopy: assessing ocular tissue biomechanics","volume":"29","author":"SH Yun","year":"2018","journal-title":"Curr Opin Ophthalmol"},{"issue":"6","key":"pone.0353667.ref024","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1016\/j.bpj.2011.08.008","article-title":"In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy","volume":"101","author":"G Scarcelli","year":"2011","journal-title":"Biophys J"},{"issue":"1","key":"pone.0353667.ref025","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1167\/iovs.11-8281","article-title":"Brillouin optical microscopy for corneal biomechanics","volume":"53","author":"G Scarcelli","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"7","key":"pone.0353667.ref026","doi-asserted-by":"crossref","first-page":"3020","DOI":"10.1167\/iovs.18-24228","article-title":"Effects of corneal hydration on Brillouin microscopy in vivo","volume":"59","author":"P Shao","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"7","key":"pone.0353667.ref027","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1167\/tvst.9.7.26","article-title":"Detecting mechanical anisotropy of the cornea using Brillouin microscopy","volume":"9","author":"JN Webb","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"pone.0353667.ref028","year":"2012"},{"issue":"33","key":"pone.0353667.ref029","doi-asserted-by":"crossref","first-page":"6704","DOI":"10.1364\/AO.42.006704","article-title":"Measurement of the bulk viscosity of liquid by Brillouin scattering","volume":"42","author":"J Xu","year":"2003","journal-title":"Appl Opt"},{"issue":"3","key":"pone.0353667.ref030","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1088\/0034-4885\/45\/3\/002","article-title":"Brillouin scattering in condensed matter","volume":"45","author":"J Dil","year":"1982","journal-title":"Rep Prog Phys"},{"issue":"17","key":"pone.0353667.ref031","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1051\/anphys\/192209170088","article-title":"Diffusion de la lumi\u00e8re et des rayons X par un corps transparent homog\u00e8ne","volume":"9","author":"L Brillouin","year":"1922","journal-title":"Ann Phys (NY)"},{"issue":"8","key":"pone.0353667.ref032","first-page":"3389","article-title":"Verification of Brillouin scanning results with a novel device","volume":"66","author":"H Glucksman","year":"2025","journal-title":"InvestOphthalmol Vis Sci"},{"issue":"8","key":"pone.0353667.ref033","first-page":"3439","article-title":"Repeatability and reproducibility of anterior segment stiffness measurements with a novel Brillouin scanning device","volume":"64","author":"H Glucksman","year":"2023","journal-title":"InvestOphthalmol Vis Sci"},{"issue":"1","key":"pone.0353667.ref034","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.jcrs.2014.04.038","article-title":"Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: repeatability, reproducibility, and agreement","volume":"41","author":"Q Wang","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"pone.0353667.ref035","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1097\/OPX.0000000000000566","article-title":"Reliability and reproducibility of a handheld videorefractor","volume":"92","author":"KC Ogbuehi","year":"2015","journal-title":"Optom Vis Sci"},{"issue":"2","key":"pone.0353667.ref036","article-title":"Repeatability and reproducibility of a double-pass optical quality analysis device","volume":"10","author":"C-C Xu","year":"2015","journal-title":"PLoS One"},{"issue":"11","key":"pone.0353667.ref037","doi-asserted-by":"crossref","first-page":"1619","DOI":"10.1016\/j.jcrs.2019.07.002","article-title":"Repeatability and reproducibility of optical biometry implemented in a new optical coherence tomographer and comparison with a optical low-coherence reflectometer","volume":"45","author":"P Kanclerz","year":"2019","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"pone.0353667.ref038","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1080\/17434440.2022.2075725","article-title":"Repeatability and reproducibility of the Galilei G6 and its agreement with the Pentacam\u00ae AXL in optical biometry and corneal tomography","volume":"19","author":"M Moshirfar","year":"2022","journal-title":"Expert Rev Med Devices"},{"issue":"1","key":"pone.0353667.ref039","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1038\/s41598-020-79674-4","article-title":"Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices","volume":"11","author":"D Schiano-Lomoriello","year":"2021","journal-title":"Sci Rep"},{"issue":"1","key":"pone.0353667.ref040","doi-asserted-by":"crossref","first-page":"14440","DOI":"10.1038\/s41598-020-71192-7","article-title":"Repeatability, reproducibility, and comparison of ocular biometry using a new optical coherence tomography-based system and another device","volume":"10","author":"A Wyl\u0119ga\u0142a","year":"2020","journal-title":"Sci Rep"},{"issue":"1","key":"pone.0353667.ref041","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s40662-023-00343-4","article-title":"Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer","volume":"10","author":"A Dom\u00ednguez-Vicent","year":"2023","journal-title":"Eye Vis"},{"issue":"4","key":"pone.0353667.ref042","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1167\/iovs.66.4.6","article-title":"In vivo Brillouin analysis of lens nucleus and cortex in adult myopic eyes and their correlation with accommodation","volume":"66","author":"L Chang","year":"2025","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"pone.0353667.ref043","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/s12886-026-04617-y","article-title":"Quantitative assessment of the biomechanical properties of healthy human myopic corneas using Brillouin spectroscopy","volume":"26","author":"J Jeong","year":"2026","journal-title":"BMC Ophthalmol"},{"issue":"8","key":"pone.0353667.ref044","first-page":"4972","article-title":"Comparing the biomechanics of the crystalline lens, with aging, in humans and in ex vivo porcine eyes","volume":"64","author":"CS Barnes","year":"2023","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"pone.0353667.ref045","first-page":"359","article-title":"Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study","volume":"10","author":"RF Rashid","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"pone.0353667.ref046","article-title":"Applanation tonometry","volume-title":"StatPearls","author":"M Zeppieri","year":"2023"},{"issue":"4","key":"pone.0353667.ref047","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.joco.2016.04.004","article-title":"Comparison of the visual acuity after photorefractive keratectomy using Early Treatment Diabetic Retinopathy Study Chart and E-chart","volume":"28","author":"S Ghorbanhosseini","year":"2016","journal-title":"J Curr Ophthalmol"},{"issue":"2","key":"pone.0353667.ref048","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/S0002-9394(02)01529-5","article-title":"The VF-14 index of visual function in recipients of a corneal graft: a 2-year follow-up study","volume":"134","author":"H Boisjoly","year":"2002","journal-title":"Am J Ophthalmol"},{"issue":"12","key":"pone.0353667.ref049","doi-asserted-by":"crossref","first-page":"2114","DOI":"10.3390\/medicina59122114","article-title":"Optical coherence tomography (OCT): A brief look at the uses and technological evolution of ophthalmology","volume":"59","author":"M Zeppieri","year":"2023","journal-title":"Medicina (B Aires)"},{"issue":"3","key":"pone.0353667.ref050","first-page":"177","article-title":"Pentacam\u00ae corneal tomography for screening of refractive surgery candidates: a review of the literature, Part I","volume":"8","author":"MN Motlagh","year":"2019","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"key":"pone.0353667.ref051","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-030-54863-6_3","article-title":"Pentacam.","author":"M Mohammadpour","year":"2021","journal-title":"Diagnostics in ocular imaging. Cham, Switzerland: Springer"},{"key":"pone.0353667.ref052","unstructured":"International Organization for Standardization (ISO). Accuracy (trueness and precision) of measurement methods and results \u2014 Part 6: Use in practice of accuracy values. Geneva, Switzerland: International Organization for Standardization (ISO). 1994."},{"key":"pone.0353667.ref053","unstructured":"International Electrotechnical Commission. IEC 60601-1: Edition 3.2 (2020). Medical electrical equipment\u2014Part 1: General requirements for basic safety and essential performance. Geneva, Switzerland: International Electrotechnical Commission. 2005."},{"key":"pone.0353667.ref054","doi-asserted-by":"crossref","unstructured":"ANSI Z136.1-2014, American National Standard for the Safe Use of Lasers. Orlando, FL: Laser Institute of America (LIA). 2014.","DOI":"10.1364\/FIO.2014.FW1F.2"},{"issue":"6","key":"pone.0353667.ref055","doi-asserted-by":"crossref","first-page":"510","DOI":"10.3341\/kjo.2023.0092","article-title":"Repeatability and agreement of chord mu between Scheimpflug tomography and swept-source optical coherence tomography","volume":"37","author":"NH Kim","year":"2023","journal-title":"Korean J Ophthalmol"},{"issue":"2","key":"pone.0353667.ref056","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1080\/03078698.1994.9674078","article-title":"Some comments on the repeatability of measurements","volume":"15","author":"DGC Harper","year":"1994","journal-title":"Ring Migr"},{"issue":"13","key":"pone.0353667.ref057","doi-asserted-by":"crossref","first-page":"5093","DOI":"10.1167\/iovs.16-20143","article-title":"In vivo Brillouin analysis of the aging crystalline lens","volume":"57","author":"S Besner","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"12","key":"pone.0353667.ref058","doi-asserted-by":"crossref","first-page":"6196","DOI":"10.1364\/BOE.472053","article-title":"Motion-tracking Brillouin microscopy for in-vivo corneal biomechanics mapping","volume":"13","author":"H Zhang","year":"2022","journal-title":"Biomed Opt Express"},{"issue":"4","key":"pone.0353667.ref059","doi-asserted-by":"crossref","first-page":"288","DOI":"10.4103\/ijo.IJO_729_16","article-title":"Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes","volume":"65","author":"M Kumar","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"pone.0353667.ref060","doi-asserted-by":"crossref","first-page":"370592","DOI":"10.1155\/2013\/370592","article-title":"Repeatability and reproducibility of measurements using a NT-530P noncontact tono\/pachymeter and correlation of central corneal thickness with intraocular pressure","volume":"2013","author":"F Fujimura","year":"2013","journal-title":"Biomed Res Int"},{"key":"pone.0353667.ref061","doi-asserted-by":"crossref","first-page":"1516395","DOI":"10.1155\/2017\/1516395","article-title":"Comparison of repeatability and agreement between swept-source optical biometry and dual-Scheimpflug topography","volume":"2017","author":"S Jung","year":"2017","journal-title":"J Ophthalmol"},{"issue":"1","key":"pone.0353667.ref062","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1186\/s12886-018-0976-y","article-title":"Optical coherence tomography angiography of the macula and optic nerve head: microvascular density and test-retest repeatability in normal subjects","volume":"18","author":"CW Lim","year":"2018","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"pone.0353667.ref063","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1111\/opo.12219","article-title":"Repeatability of a novel corneal indentation device for corneal biomechanical measurement","volume":"35","author":"AKC Lam","year":"2015","journal-title":"Ophthalmic Physiol Optics"},{"issue":"11","key":"pone.0353667.ref064","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1136\/bjo.2007.118901","article-title":"Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography","volume":"91","author":"H Li","year":"2007","journal-title":"Br J Ophthalmol"},{"issue":"3","key":"pone.0353667.ref065","doi-asserted-by":"crossref","first-page":"129","DOI":"10.4103\/0301-4738.109384","article-title":"Test retest variability of TonoPen AVIA","volume":"61","author":"S Bhartiya","year":"2013","journal-title":"Indian J Ophthalmol"},{"issue":"1","key":"pone.0353667.ref066","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/s10792-024-03309-0","article-title":"Corneal densitometry measurements comparison between anterior segment OCT and scheimpflug imaging","volume":"44","author":"E Lupardi","year":"2024","journal-title":"Int Ophthalmol"},{"issue":"6","key":"pone.0353667.ref067","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1016\/j.ophtha.2007.08.023","article-title":"Reproducibility of pattern electroretinogram in glaucoma patients with a range of severity of disease with the new glaucoma paradigm","volume":"115","author":"M-J Fredette","year":"2008","journal-title":"Ophthalmology"},{"issue":"1","key":"pone.0353667.ref068","article-title":"Long-term repeatability of optical coherence tomography angiography parameters in healthy eyes","volume":"98","author":"M-W Lee","year":"2020","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"pone.0353667.ref069","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1167\/tvst.13.1.25","article-title":"Biometry-based technique for determining the anterior scleral thickness: validation using optical coherence tomography landmarks","volume":"13","author":"SK Gupta","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"pone.0353667.ref070","doi-asserted-by":"crossref","first-page":"8515742","DOI":"10.1155\/2017\/8515742","article-title":"Repeatability and reproducibility of intraocular pressure and dynamic corneal response parameters assessed by the Corvis ST","volume":"2017","author":"BT Lopes","year":"2017","journal-title":"J Ophthalmol"},{"issue":"4","key":"pone.0353667.ref071","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0230589","article-title":"Reproducibility, and repeatability of corneal topography measured by Revo NX, Galilei G6 and Casia 2 in normal eyes","volume":"15","author":"A Wyl\u0119ga\u0142a","year":"2020","journal-title":"PLoS One"},{"issue":"10","key":"pone.0353667.ref072","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0206045","article-title":"Repeatability, reproducibility and agreement of foveal avascular zone measurements using three different optical coherence tomography angiography devices","volume":"13","author":"N Mihailovic","year":"2018","journal-title":"PLoS One"},{"issue":"1","key":"pone.0353667.ref073","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1038\/s41598-020-57926-7","article-title":"Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus","volume":"10","author":"D Schiano-Lomoriello","year":"2020","journal-title":"Sci Rep"},{"issue":"8","key":"pone.0353667.ref074","doi-asserted-by":"crossref","DOI":"10.3928\/1081597X-20240701-02","article-title":"The KERATO Biomechanics Study 1: a comparative evaluation using Brillouin microscopy and dynamic Scheimpflug imaging","volume":"40","author":"R Vinciguerra","year":"2024","journal-title":"J Refract Surg"},{"issue":"5","key":"pone.0353667.ref075","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.exer.2008.02.006","article-title":"Biomechanical properties of human and porcine corneas","volume":"86","author":"A Elsheikh","year":"2008","journal-title":"Exp Eye Res"},{"issue":"4","key":"pone.0353667.ref076","doi-asserted-by":"crossref","first-page":"30","DOI":"10.31083\/j.fbs1404030","article-title":"Measurement of the elastic modulus of cornea, sclera and limbus: the importance of the corneal-limbus-ccleral biomechanical unit","volume":"14","author":"FH Silver","year":"2022","journal-title":"Front Biosci (Schol Ed)"},{"issue":"12","key":"pone.0353667.ref077","doi-asserted-by":"crossref","first-page":"124511","DOI":"10.1117\/1.JBO.30.12.124511","article-title":"Clinical multimodal Brillouin microscopy-optical coherence elastography system for lens biomechanics","volume":"30","author":"J Schumacher","year":"2025","journal-title":"J Biomed Opt"},{"issue":"12","key":"pone.0353667.ref078","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0338302","article-title":"High-resolution biomechanical mapping of SMILE and SMILE with CXL using Brillouin microscopy: Insights into localized corneal stiffness preservation","volume":"20","author":"J Jeong","year":"2025","journal-title":"PLoS One"},{"issue":"10","key":"pone.0353667.ref079","doi-asserted-by":"crossref","first-page":"3243","DOI":"10.1007\/s00417-024-06510-0","article-title":"A Brillouin microscopy analysis of the crystalline lenses of Chinese adults with myopia","volume":"262","author":"Y Ma","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"6","key":"pone.0353667.ref080","doi-asserted-by":"crossref","DOI":"10.3928\/1081597X-20250506-01","article-title":"KERATO Biomechanics Study 2: a comparative evaluation before and after corneal cross-linking using Brillouin microscopy and dynamic Scheimpflugimaging","volume":"41","author":"R Vinciguerra","year":"2025","journal-title":"J Refract Surg"},{"issue":"6","key":"pone.0353667.ref081","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3390\/bioengineering12060634","article-title":"Application of the Brillouin Optical Scanning System in the regional corneal biomechanical evaluation of keratoconus and its correlation with Corvis ST parameters","volume":"12","author":"Q Jiang","year":"2025","journal-title":"Bioengineering (Basel)"},{"issue":"4","key":"pone.0353667.ref082","doi-asserted-by":"crossref","first-page":"100579","DOI":"10.1016\/j.optom.2025.100579","article-title":"Comparison of corneal biomechanics in post-smile, post-LASEK, and normal eyes with Brillouin microscopy","volume":"18","author":"Y Yu","year":"2025","journal-title":"J Optom"},{"key":"pone.0353667.ref083","doi-asserted-by":"crossref","first-page":"4001","DOI":"10.2147\/OPTH.S555070","article-title":"Brillouin metrics of the crystalline lens comparison between low-medium myopia and high myopia","volume":"19","author":"Y Bao","year":"2025","journal-title":"Clin Ophthalmol"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0353667","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T17:25:19Z","timestamp":1784568319000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0353667"}},"subtitle":[],"editor":[{"given":"Yu-Chi","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,7,20]]},"references-count":83,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7,20]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0353667","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,20]]}}}