{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T18:19:58Z","timestamp":1787854798785,"version":"build-2784847793"},"reference-count":35,"publisher":"Public Library of Science (PLoS)","issue":"8","license":[{"start":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T00:00:00Z","timestamp":1787788800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Ajman University\u2013UAE"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:sec id=\"sec001\">\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>This in vitro study evaluated the extent accuracy of canal shaping to apical constriction (AC) with electronic apex locator (EAL)-integrated endodontic motors using micro-computed tomography (MicroCT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec002\">\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Sixty single-canalled teeth were decoronated, scanned using microCT, and distributed into three groups: Rooter Universal, Tri Auto ZX II, and control group (n\u2009=\u200920 each). The working length (WL) was determined simultaneously during canal shaping using the auto-reverse function set at the 0.5 mark in the RU and TA groups. In the control group, the WL was measured before the shaping using Root ZX (J. Morita, Tokyo, Japan). In the three groups, canals were shaped using ProTaper Gold files (Dentsply Sirona, Ballaigues, Switzerland) until the preset mark was reached in the two experimental groups and to the measured WL in the control group. Afterwards, post-shaping microCT scans were taken. Scan superimposition was conducted to assess the absolute distance between the final shaping endpoint and AC. Negative and positive data were recorded when the measurements were found short or beyond the AC, respectively. Analysis of variance (ANOVA) and post-hoc Tukey tests were used to analyze the distance. The chi-square test was applied to analyze the accuracy of the measurements with respect to the AC. The significance level was set at 5%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec003\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>No over-shaping beyond the apical foramen was found in any sample, and all systems showed similar accuracy when a tolerance of 0.5 mm was set ((V\u2009=\u20090.263, P\u2009=\u20090.126). However, the shaping extent to AC was closer in the control group than the RU (P\u2009=\u20090.001) and TA (P\u2009&lt;\u20090.001), while RU and TA were similar (P\u2009=\u20090.588).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sec004\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The accuracy of WL determination was not affected by the tested EAL. However, the standalone EAL was more reliable at maintaining AC integrity.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1371\/journal.pone.0355939","type":"journal-article","created":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T17:32:48Z","timestamp":1787851968000},"page":"e0355939","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Micro-CT evaluation of canal shaping extent with apex locator\u2013integrated endodontic motors: An in vitro study"],"prefix":"10.1371","volume":"21","author":[{"given":"Zainab","family":"Shirazi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9726-7884","authenticated-orcid":true,"given":"Anas","family":"Al-Jadaa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dalya","family":"Sharaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulrahman Mohammed","family":"Saleh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9504-2921","authenticated-orcid":true,"given":"Ahmed","family":"Jamleh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2026,8,27]]},"reference":[{"issue":"7","key":"pone.0355939.ref001","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1111\/j.1365-2591.2011.01872.x","article-title":"A prospective study of the factors affecting outcomes of nonsurgical root canal treatment: part 1: periapical health","volume":"44","author":"Y-L Ng","year":"2011","journal-title":"Int Endod J"},{"key":"pone.0355939.ref002","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.jdent.2017.06.005","article-title":"Ex vivo investigation on the postoperative integrity of the apical constriction after the sole use of electronic working length determination","volume":"64","author":"M Wolgin","year":"2017","journal-title":"J Dent"},{"key":"pone.0355939.ref003","volume-title":"Glossary of Endodontic Terms","author":"American Association of Endodontists","year":"2012","edition":"7"},{"issue":"8","key":"pone.0355939.ref004","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.joen.2013.12.002","article-title":"Apical constriction: location and dimensions in molars-a micro-computed tomography study","volume":"40","author":"A ElAyouti","year":"2014","journal-title":"J Endod"},{"key":"pone.0355939.ref005","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1111\/j.1365-2591.2006.01180.x","article-title":"Quality guidelines for endodontic treatment: consensus report of the European Society of Endodontology","volume":"39","author":"Endodontology European Society of","year":"2006","journal-title":"Int Endod J"},{"issue":"7","key":"pone.0355939.ref006","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1111\/j.1365-2591.2004.00835.x","article-title":"Electronic apex locators","volume":"37","author":"MPJ Gordon","year":"2004","journal-title":"Int Endod J"},{"key":"pone.0355939.ref007","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/aej.12703","article-title":"Working length variation during multiple-visit endodontic treatment: an observational study","author":"M Alovisi","year":"2023","journal-title":"Aust Endod J"},{"issue":"2","key":"pone.0355939.ref008","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1007\/s00784-021-04103-3","article-title":"Evaluation of foramen locating accuracy of an endodontic motor integrated with electronic foramen employing optimal glide path kinematics","volume":"26","author":"RA Bernardes","year":"2022","journal-title":"Clin Oral Investig"},{"issue":"3","key":"pone.0355939.ref009","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1007\/s10266-024-01039-4","article-title":"Integrated electronic apex locators for determining working length: a systematic review of in-vitro studies","volume":"113","author":"GRM La Rosa","year":"2025","journal-title":"Odontology"},{"issue":"3","key":"pone.0355939.ref010","first-page":"437","article-title":"Accuracy of working length measurement with endo motor having built-in apex locator and comparison with periapical radiographs","volume":"70","author":"SYA Abidi","year":"2020","journal-title":"J Pak Med Assoc"},{"issue":"3","key":"pone.0355939.ref011","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.tripleo.2008.11.010","article-title":"Accuracy of electronic apex locater-controlled handpieces","volume":"107","author":"J Barthelemy","year":"2009","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"pone.0355939.ref012","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/j.joen.2022.06.003","article-title":"Micro-CT study of the in vivo accuracy of a wireless electronic apex locator","volume":"48","author":"G De-Deus","year":"2022","journal-title":"J Endod"},{"key":"pone.0355939.ref013","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.joen.2016.04.024","article-title":"The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision","volume":"42","author":"L Piasecki","year":"2016","journal-title":"J Endod"},{"issue":"7","key":"pone.0355939.ref014","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1111\/iej.12670","article-title":"Validity of longitudinal sections for determining the apical constriction","volume":"50","author":"S Schell","year":"2017","journal-title":"Int Endod J"},{"issue":"17","key":"pone.0355939.ref015","doi-asserted-by":"crossref","first-page":"5199","DOI":"10.3390\/jcm13175199","article-title":"Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation","volume":"13","author":"RM Barakat","year":"2024","journal-title":"J Clin Med"},{"issue":"8","key":"pone.0355939.ref016","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1097\/00004770-200308000-00002","article-title":"An in vivo comparison of two frequency-based electronic apex locators","volume":"29","author":"AR Welk","year":"2003","journal-title":"J Endod"},{"issue":"5","key":"pone.0355939.ref017","doi-asserted-by":"crossref","first-page":"458","DOI":"10.4103\/0972-0707.117506","article-title":"An in vitro stereomicroscopic comparative evaluation of a combination of apex locator and endodontic motor with an integrated endodontic motor","volume":"16","author":"C Swarupa","year":"2013","journal-title":"J Conserv Dent"},{"issue":"5","key":"pone.0355939.ref018","doi-asserted-by":"crossref","first-page":"399","DOI":"10.5005\/jp-journals-10015-1860","article-title":"Evaluation of the Efficacy of Different Systems in Determination of Root Canal Working Length: A Comparative Study","volume":"12","author":"A Reddy","year":"2021","journal-title":"World Journal of Dentistry"},{"issue":"3","key":"pone.0355939.ref019","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S1079-2104(98)90016-6","article-title":"Apical extent of rotary canal instrumentation with an apex-locating handpiece in vitro","volume":"85","author":"D Campbell","year":"1998","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"7","key":"pone.0355939.ref020","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.joen.2009.04.025","article-title":"An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files","volume":"35","author":"C Siu","year":"2009","journal-title":"J Endod"},{"issue":"5","key":"pone.0355939.ref021","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1016\/j.joen.2013.09.002","article-title":"Accuracy and reliability of working length determination by Gold Reciproc Motor in reciprocating movement","volume":"40","author":"R Wigler","year":"2014","journal-title":"J Endod"},{"issue":"1","key":"pone.0355939.ref022","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1186\/s12903-017-0425-y","article-title":"The accuracy of the auto-stop function of different endodontic devices in detecting the apical constriction","volume":"17","author":"DW Christofzik","year":"2017","journal-title":"BMC Oral Health"},{"issue":"1","key":"pone.0355939.ref023","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1067\/moe.2003.99","article-title":"Clinical evaluation of the measuring accuracy of ROOT ZX in primary teeth","volume":"95","author":"AM Kielbassa","year":"2003","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"5","key":"pone.0355939.ref024","doi-asserted-by":"crossref","first-page":"544","DOI":"10.14219\/jada.archive.1955.0099","article-title":"Microscopic investigation of root apexes","volume":"50","author":"Y KUTTLER","year":"1955","journal-title":"J Am Dent Assoc"},{"issue":"2","key":"pone.0355939.ref025","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/iej.12814","article-title":"Evaluation of the accuracy of nine electronic apex locators by using Micro-CT","volume":"51","author":"T Connert","year":"2018","journal-title":"Int Endod J"},{"issue":"2","key":"pone.0355939.ref026","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/00004770-200202000-00017","article-title":"The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length","volume":"28","author":"A ElAyouti","year":"2002","journal-title":"J Endod"},{"issue":"3","key":"pone.0355939.ref027","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1111\/iej.12140","article-title":"Accuracy of working length measurement: electronic apex locator versus cone-beam computed tomography","volume":"47","author":"C Lucena","year":"2014","journal-title":"Int Endod J"},{"issue":"9","key":"pone.0355939.ref028","doi-asserted-by":"crossref","first-page":"5239","DOI":"10.1007\/s00784-021-03831-w","article-title":"The influence of periapical lesions on the repeatability of two electronic apex locators in vivo","volume":"25","author":"CG Adorno","year":"2021","journal-title":"Clin Oral Investig"},{"issue":"2","key":"pone.0355939.ref029","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/j.1365-2591.2006.01199.x","article-title":"In vivo comparison of working length determination with two electronic apex locators","volume":"40","author":"KT Wrbas","year":"2007","journal-title":"Int Endod J"},{"issue":"8","key":"pone.0355939.ref030","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1111\/iej.12057","article-title":"In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants","volume":"46","author":"F Duran-Sindreu","year":"2013","journal-title":"Int Endod J"},{"issue":"8","key":"pone.0355939.ref031","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.jdent.2004.11.017","article-title":"Accuracy of electronic apex locators in comparison to actual length--an in vivo study","volume":"33","author":"C Haffner","year":"2005","journal-title":"J Dent"},{"issue":"4","key":"pone.0355939.ref032","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1111\/j.1365-2591.2008.01535.x","article-title":"Combination of apex locator and endodontic motor for continuous length control during root canal treatment","volume":"42","author":"MJ Altenburger","year":"2009","journal-title":"Int Endod J"},{"issue":"5","key":"pone.0355939.ref033","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1590\/0103-6440201300099","article-title":"Efficacy of electronic foramen locators in controlling root canal working length during rotary instrumentation","volume":"26","author":"LA Parente","year":"2015","journal-title":"Braz Dent J"},{"issue":"4","key":"pone.0355939.ref034","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1055\/s-0044-1782214","article-title":"Influence of different apical foramen morphologies on the accuracy of four electronic foramen locators","volume":"18","author":"RD Furlan","year":"2024","journal-title":"Eur J Dent"},{"issue":"5","key":"pone.0355939.ref035","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0176724","article-title":"Radiologic assessment of quality of root canal fillings and periapical status in an Austrian subpopulation - An observational study","volume":"12","author":"AM Kielbassa","year":"2017","journal-title":"PLoS One"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0355939","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T17:32:54Z","timestamp":1787851974000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0355939"}},"subtitle":[],"editor":[{"given":"Andrej M","family":"Kielbassa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,8,27]]},"references-count":35,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8,27]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0355939","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,27]]}}}