{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T18:50:44Z","timestamp":1791312644715,"version":"4.3.1"},"reference-count":41,"publisher":"Public Library of Science (PLoS)","issue":"10","license":[{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005632","name":"Narodowe Centrum Bada\u0144 i Rozwoju","doi-asserted-by":"publisher","award":["Rzeczy s\u0105 dla ludzi\/0004\/2020"],"award-info":[{"award-number":["Rzeczy s\u0105 dla ludzi\/0004\/2020"]}],"id":[{"id":"10.13039\/501100005632","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS One"],"abstract":"<jats:p>\n                    Manual wheelchair users may have reduced physical activity and total energy expenditure, while wearable devices may not adequately capture external mechanical demand during wheelchair propulsion. This pilot study examined whether wheel-level mechanical power combined with heart rate could estimate mass-specific oxygen uptake (V\u0307O2\/kg) during manual wheelchair propulsion. Ten long-term manual wheelchair users aged 29\u201338 years completed 3-min trials under three progressively loaded conditions on a wheelchair ergometer. Wheel velocity and braking torque were measured, mechanical power was calculated from trial-mean torque and angular velocity, and metabolic variables were assessed using a wearable respiratory gas analyzer. A two-predictor linear regression model was developed, with participant-clustered standard errors and leave-one-participant-out cross-validation (LOPO-CV) for internal evaluation. V\u0307O2\/kg increased across conditions despite lower velocity under the highest load. The final model was V\u0307O\n                    <jats:sub>2<\/jats:sub>\n                    \/kg\u2009=\u20095.5738\u2009+\u20090.2444P\u2009+\u20090.03587HR. Mechanical power (95% CI: 0.1330\u20130.3558) and heart rate (95% CI: 0.01342\u20130.05833) were significant positive predictors. The model explained 72.2% of the variance (\n                    <jats:inline-formula id=\"pone.0359323.e001\">\n                      <jats:alternatives>\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" id=\"pone.0359323.e001g\" mimetype=\"image\" position=\"anchor\" xlink:href=\"info:doi\/10.1371\/journal.pone.0359323.e001\" xlink:type=\"simple\"\/>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" display=\"inline\" id=\"M1\">\n                          <mml:mrow>\n                            <mml:msup>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mi>R<\/mml:mi>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mtext>2<\/mml:mtext>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                            <\/mml:msup>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    = 0.722; adjusted\n                    <jats:inline-formula id=\"pone.0359323.e002\">\n                      <jats:alternatives>\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" id=\"pone.0359323.e002g\" mimetype=\"image\" position=\"anchor\" xlink:href=\"info:doi\/10.1371\/journal.pone.0359323.e002\" xlink:type=\"simple\"\/>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" display=\"inline\" id=\"M2\">\n                          <mml:mrow>\n                            <mml:msup>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mi>R<\/mml:mi>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mtext>2<\/mml:mtext>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                            <\/mml:msup>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    = 0.701). LOPO-CV yielded an RMSE of 1.128 mL O\n                    <jats:sub>2<\/jats:sub>\n                    \u00b7kg\n                    <jats:sup>\u22121<\/jats:sup>\n                    \u00b7min\n                    <jats:sup>\u22121<\/jats:sup>\n                    , an MAE of 0.917 mL O\n                    <jats:sub>2<\/jats:sub>\n                    \u00b7kg\n                    <jats:sup>\u22121<\/jats:sup>\n                    \u00b7min\n                    <jats:sup>\u22121<\/jats:sup>\n                    , and\n                    <jats:inline-formula id=\"pone.0359323.e003\">\n                      <jats:alternatives>\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" id=\"pone.0359323.e003g\" mimetype=\"image\" position=\"anchor\" xlink:href=\"info:doi\/10.1371\/journal.pone.0359323.e003\" xlink:type=\"simple\"\/>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" display=\"inline\" id=\"M3\">\n                          <mml:mrow>\n                            <mml:msup>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mi>R<\/mml:mi>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                              <mml:mrow>\n                                <mml:mrow>\n                                  <mml:mtext>2<\/mml:mtext>\n                                <\/mml:mrow>\n                              <\/mml:mrow>\n                            <\/mml:msup>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    = 0.575. Repeated-measures Bland\u2013Altman analysis of LOPO-CV predictions showed a mean bias of \u22120.156 mL O\n                    <jats:sub>2<\/jats:sub>\n                    \u00b7kg\n                    <jats:sup>\u22121<\/jats:sup>\n                    \u00b7min\n                    <jats:sup>\u22121<\/jats:sup>\n                    (95% CI: \u22120.6259 to 0.2022), with limits of agreement from \u22122.389 (95% CI: \u22123.1667 to \u22121.7711) to 2.077 mL O\n                    <jats:sub>2<\/jats:sub>\n                    \u00b7kg\n                    <jats:sup>\u22121<\/jats:sup>\n                    \u00b7min\n                    <jats:sup>\u22121<\/jats:sup>\n                    (95% CI: 1.6096 to 2.6636). Mechanical power and heart rate may provide complementary information for estimating metabolic demand during manual wheelchair propulsion. However, the model was developed in a small exploratory sample, was only internally evaluated, and requires external validation before practical application.\n                  <\/jats:p>","DOI":"10.1371\/journal.pone.0359323","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T17:53:52Z","timestamp":1791309232000},"page":"e0359323","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["A preliminary model for estimating mass-specific oxygen uptake during manual wheelchair propulsion from mechanical power and heart rate"],"prefix":"10.1371","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3456-3824","authenticated-orcid":true,"given":"Mateusz","family":"Kukla","sequence":"first","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Machine Design"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0954-2012","authenticated-orcid":true,"given":"Micha\u0142","family":"Ko\u0144czak","sequence":"additional","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Machine Design"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maciej","family":"Berdychowski","sequence":"additional","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Machine Design"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominik","family":"Rybarczyk","sequence":"additional","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Mechanical Technology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0808-298X","authenticated-orcid":true,"given":"Bartosz","family":"Wieczorek","sequence":"additional","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Machine Design"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u0141ukasz","family":"Wargu\u0142a","sequence":"additional","affiliation":[{"name":"Poznan University of Technology","place":["Pozna\u0144, Poland"],"department":["Institute of Machine Design"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2026,10,6]]},"reference":[{"key":"pone.0359323.ref001","article-title":"Persons with disabilities as an unrecognized health disparity population","author":"GL Krahn","year":"2015","journal-title":"Am J Public Health"},{"issue":"2","key":"pone.0359323.ref002","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0191556","article-title":"Accuracy and precision of consumer-level activity monitors for stroke detection during wheelchair propulsion and arm ergometry","volume":"13","author":"J Kressler","year":"2018","journal-title":"PLoS One"},{"issue":"6","key":"pone.0359323.ref003","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1007\/s12541-021-00482-5","article-title":"Development of an energy expenditure estimation formula associated with the wheelchair activity of disabled people with a spinal cord injury","volume":"22","author":"JS Kang","year":"2021","journal-title":"Int J Precis Eng Manuf"},{"issue":"7","key":"pone.0359323.ref004","doi-asserted-by":"crossref","DOI":"10.1016\/j.apmr.2016.02.016","article-title":"Estimation of energy expenditure for wheelchair users using a physical activity monitoring system","volume":"97","author":"SV Hiremath","year":"2016","journal-title":"Arch Phys Med Rehabil"},{"issue":"5","key":"pone.0359323.ref005","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1017\/S0007114521003822","article-title":"Energy expenditure and nutrient intake after spinal cord injury: A comprehensive review and practical recommendations","volume":"128","author":"GJ Farkas","year":"2022","journal-title":"Br J Nutr"},{"key":"pone.0359323.ref006","doi-asserted-by":"crossref","first-page":"478","DOI":"10.3389\/fneur.2018.00478","article-title":"Estimation of energy expenditure in wheelchair-bound spinal cord injured individuals using inertial measurement units","volume":"9","author":"WL Popp","year":"2018","journal-title":"Front Neurol"},{"issue":"1","key":"pone.0359323.ref007","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/JES.0b013e31823b8b82","article-title":"Effects of disability-associated low energy expenditure deconditioning syndrome","volume":"40","author":"JH Rimmer","year":"2012","journal-title":"Exerc Sport Sci Rev"},{"issue":"11","key":"pone.0359323.ref008","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1038\/sc.2011.63","article-title":"The development of evidence-informed physical activity guidelines for adults with spinal cord injury","volume":"49","author":"KAM Ginis","year":"2011","journal-title":"Spinal Cord"},{"issue":"1","key":"pone.0359323.ref009","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jada.2010.10.008","article-title":"Self-monitoring in weight loss: A systematic review of the literature","volume":"111","author":"LE Burke","year":"2011","journal-title":"J Am Diet Assoc"},{"issue":"8","key":"pone.0359323.ref010","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1002\/oby.21536","article-title":"Impact of newer self-monitoring technology and brief phone-based intervention on weight loss: A randomized pilot study","volume":"24","author":"KM Ross","year":"2016","journal-title":"Obesity"},{"issue":"1","key":"pone.0359323.ref011","doi-asserted-by":"crossref","first-page":"92","DOI":"10.46292\/sci20-00030","article-title":"Energy expenditure following spinal cord injury: A delicate balance","volume":"27","author":"GJ Farkas","year":"2021","journal-title":"Top Spinal Cord Inj Rehabil"},{"issue":"8","key":"pone.0359323.ref012","doi-asserted-by":"crossref","first-page":"681","DOI":"10.2165\/11531960-000000000-00000","article-title":"Energy expenditure and metabolism during exercise in persons with a spinal cord injury","volume":"40","author":"M Price","year":"2010","journal-title":"Sports Med"},{"issue":"6","key":"pone.0359323.ref013","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1093\/ajcn\/68.6.1223","article-title":"Lower daily energy expenditure as measured by a respiratory chamber in subjects with spinal cord injury compared with control subjects","volume":"68","author":"MB Monroe","year":"1998","journal-title":"Am J Clin Nutr"},{"key":"pone.0359323.ref014","doi-asserted-by":"crossref","unstructured":"Hiremath SV, Ding D. Regression equations for RT3 activity monitors to estimate energy expenditure in manual wheelchair users. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society; 2011. p. 7348\u201351. https:\/\/doi.org\/10.1109\/IEMBS.2011.6091714","DOI":"10.1109\/IEMBS.2011.6091714"},{"issue":"1","key":"pone.0359323.ref015","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1179\/107902610X12911165975142","article-title":"Evaluation of activity monitors in manual wheelchair users with paraplegia","volume":"34","author":"SV Hiremath","year":"2011","journal-title":"J Spinal Cord Med"},{"key":"pone.0359323.ref016","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1109\/TNSRE.2025.3537333","article-title":"Data-driven techniques for estimating energy expenditure in wheelchair users","volume":"33","author":"R Doshmanziari","year":"2025","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"6","key":"pone.0359323.ref017","first-page":"635","article-title":"Energy expenditure in chronic spinal cord injury","volume":"7","author":"AC Buchholz","year":"2004","journal-title":"Curr Opin Clin Nutr Metab Care"},{"issue":"4","key":"pone.0359323.ref018","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1007\/s12541-012-0079-2","article-title":"Prediction of energy consumption according to physical activity intensity in daily life using accelerometer","volume":"13","author":"D-W Kang","year":"2012","journal-title":"Int J Precis Eng Manuf"},{"issue":"2","key":"pone.0359323.ref019","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1080\/17461391.2021.2023656","article-title":"Wrist-worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense","volume":"23","author":"G Hajj-Boutros","year":"2023","journal-title":"Eur J Sport Sci"},{"issue":"6","key":"pone.0359323.ref020","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1136\/bjsports-2018-099643","article-title":"How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies","volume":"54","author":"R O\u2019Driscoll","year":"2020","journal-title":"Br J Sports Med"},{"issue":"2","key":"pone.0359323.ref021","first-page":"139","article-title":"Wheelchair-mounted accelerometers for measurement of physical activity","volume":"7","author":"SC Gendle","year":"2012","journal-title":"Disabil Rehabil: Assist Technol"},{"key":"pone.0359323.ref022","doi-asserted-by":"crossref","DOI":"10.1080\/10400435.2022.2075488","article-title":"Technologies measuring manual wheelchair propulsion metrics: A scoping review","volume":"37","author":"H MacDuff","year":"2025","journal-title":"Assist Technol"},{"issue":"13","key":"pone.0359323.ref023","doi-asserted-by":"crossref","first-page":"7447","DOI":"10.3390\/app13137447","article-title":"Considerations for the design of a wheelchair dynamometer concerning a dedicated braking system","volume":"13","author":"M Ko\u0144czak","year":"2023","journal-title":"Appl Sci"},{"issue":"4","key":"pone.0359323.ref024","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.apmr.2007.09.035","article-title":"Cardiovascular and metabolic responses during functional electric stimulation cycling at different cadences","volume":"89","author":"C Fornusek","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"issue":"8","key":"pone.0359323.ref025","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.apmr.2007.05.011","article-title":"Energy cost of the case Western reserve standing neuroprosthesis","volume":"88","author":"GP Forrest","year":"2007","journal-title":"Arch Phys Med Rehabil"},{"issue":"3","key":"pone.0359323.ref026","first-page":"290","article-title":"Assessing physical activity during wheelchair pushing: Validity of a portable accelerometer","volume":"16","author":"RA Washburn","year":"1999","journal-title":"Adapt Phys Act Q"},{"key":"pone.0359323.ref027","volume-title":"Wheelchair propulsion metabolic cost and variability: A methodological investigation","author":"TE Nightingale","year":"2015"},{"issue":"1","key":"pone.0359323.ref028","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1109\/86.296343","article-title":"Frequency content of whole body gait kinematic data","volume":"2","author":"C Angeloni","year":"1994","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"3","key":"pone.0359323.ref029","first-page":"323","article-title":"Filter frequency selection for manual wheelchair biomechanics","volume":"39","author":"RA Cooper","year":"2002","journal-title":"J Rehabil Res Dev"},{"issue":"1","key":"pone.0359323.ref030","doi-asserted-by":"crossref","DOI":"10.1136\/bmjsem-2015-000008","article-title":"Predicting physical activity energy expenditure in wheelchair users with a multisensor device","volume":"1","author":"TE Nightingale","year":"2015","journal-title":"BMJ Open Sport Exerc Med"},{"issue":"5","key":"pone.0359323.ref031","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0126086","article-title":"Influence of accelerometer type and placement on physical activity energy expenditure prediction in manual wheelchair users","volume":"10","author":"TE Nightingale","year":"2015","journal-title":"PLoS One"},{"issue":"9","key":"pone.0359323.ref032","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1249\/MSS.0000000000000291","article-title":"Predicting physical activity energy expenditure in manual wheelchair users","volume":"46","author":"TE Nightingale","year":"2014","journal-title":"Med Sci Sports Exerc"},{"key":"pone.0359323.ref033","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1038\/sc.2014.70","article-title":"Preliminary study for the assessment of physical activity using a triaxial accelerometer with a gyro sensor on the upper limbs of subjects with paraplegia driving a wheelchair on a treadmill","volume":"52","author":"K Kiuchi","year":"2014","journal-title":"Spinal Cord"},{"issue":"3","key":"pone.0359323.ref034","first-page":"430","article-title":"Energy expenditure: Components and evaluation methods","volume":"26","author":"AC Pinheiro Volp","year":"2011","journal-title":"Nutr Hosp"},{"key":"pone.0359323.ref035","volume-title":"Physical activity assessment in wheelchair users","author":"SA Conger","year":"2011"},{"issue":"4","key":"pone.0359323.ref036","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1682\/JRRD.2006.02.0017","article-title":"Assessing mobility characteristics and activity levels of manual wheelchair users","volume":"44","author":"ML Tolerico","year":"2007","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"pone.0359323.ref037","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1038\/sc.2010.126","article-title":"Development and validation of a physical activity monitor for use on a wheelchair","volume":"49","author":"EH Coulter","year":"2011","journal-title":"Spinal Cord"},{"issue":"2","key":"pone.0359323.ref038","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1080\/10400435.2015.1095810","article-title":"A novel mobile-cloud system for capturing and analyzing wheelchair maneuvering data: A pilot study","volume":"28","author":"J Fu","year":"2016","journal-title":"Assist Technol"},{"issue":"8","key":"pone.0359323.ref039","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1055\/a-1088-5629","article-title":"Validity of caloric expenditure measured from a wheelchair user smartwatch","volume":"41","author":"D Moreno","year":"2020","journal-title":"Int J Sports Med"},{"issue":"13","key":"pone.0359323.ref040","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1136\/bjsports-2014-093540","article-title":"Predicting energy expenditure through hand rim propulsion power output in individuals who use wheelchairs","volume":"48","author":"SA Conger","year":"2014","journal-title":"Br J Sports Med"},{"issue":"2","key":"pone.0359323.ref041","doi-asserted-by":"crossref","first-page":"7","DOI":"10.51371\/issn.1840-2976.2024.18.2.2","article-title":"IMU- and TENS-based work and power calculation methods in hip flexion resistance training","volume":"18","author":"D Fryc","year":"2024","journal-title":"Acta Kinesiol"}],"container-title":["PLOS One"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0359323","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T17:54:00Z","timestamp":1791309240000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0359323"}},"subtitle":[],"editor":[{"given":"Raul","family":"Bartolomeu","sequence":"first","affiliation":[{"name":"Polytechnic University of Guarda","place":["PORTUGAL"]}],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,10,6]]},"references-count":41,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,10,6]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0359323","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,6]]}}}