{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T01:39:59Z","timestamp":1791855599549,"version":"4.3.4"},"reference-count":63,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2005,2,1]],"date-time":"2005-02-01T00:00:00Z","timestamp":1107216000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2005,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Background: This case conference reviews laboratory methods for assessing oxygenation status: arterial blood gases, pulse oximetry, and CO-oximetry. Caveats of these measurements are discussed in the context of two methemoglobinemia cases.<\/jats:p><jats:p>Cases: Case 1 is a woman who presented with increased shortness of breath, productive cough, chest pain, nausea, fever, and cyanosis. CO-oximetry indicated a carboxyhemoglobin (COHb) fraction of 24.9%. She was unresponsive to O2 therapy, and no source of carbon monoxide could be noted. Case 2 is a man who presented with syncope, chest tightness, and signs of cyanosis. His arterial blood was dark brown, and CO-oximetry showed a methemoglobin (MetHb) fraction of 23%.<\/jats:p><jats:p>Issues: Oxygen saturation (So2) can be measured by three approaches that are often used interchangeably, although the measured systems are quite different. Pulse oximetry is a noninvasive, spectrophotometric method to determine arterial oxygen saturation (SaO2). CO-oximetry is a more complex and reliable method that measures the concentration of hemoglobin derivatives in the blood from which various quantities such as hemoglobin derivative fractions, total hemoglobin, and saturation are calculated. Blood gas instruments calculate the estimated O2 saturation from empirical equations using pH and Po2 values. In most patients, the results from these methods will be virtually identical, but in cases of increased dyshemoglobin fractions, including methemoglobinemia, it is crucial that the distinctions and limitations of these methods be understood.<\/jats:p><jats:p>Conclusions: So2 calculated from pH and Po2 should be interpreted with caution as the algorithms used assume normal O2 affinity, normal 2,3-diphosphoglycerate concentrations, and no dyshemoglobins or hemoglobinopathies. CO-oximeter reports should include the dyshemoglobin fractions in addition to the oxyhemoglobin fraction. In cases of increased MetHb fraction, pulse oximeter values trend toward 85%, underestimating the actual oxygen saturation. Hemoglobin M variants may yield normal MetHb and increased COHb or sulfhemoglobin fractions measured by CO-oximetry.<\/jats:p>","DOI":"10.1373\/clinchem.2004.035154","type":"journal-article","created":{"date-parts":[[2004,10,29]],"date-time":"2004-10-29T00:25:54Z","timestamp":1099009554000},"page":"434-444","source":"Crossref","is-referenced-by-count":168,"title":["Laboratory Assessment of Oxygenation in Methemoglobinemia"],"prefix":"10.1093","volume":"51","author":[{"given":"Shannon","family":"Haymond","sequence":"first","affiliation":[{"name":"Department of Pathology and Immunology, Washington University School of Medicine, 660 South Euclid Ave., St. Louis, MO 63110"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Cariappa","sequence":"first","affiliation":[{"name":"Department of Pathology and Immunology, Washington University School of Medicine, 660 South Euclid Ave., St. Louis, MO 63110"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles S","family":"Eby","sequence":"first","affiliation":[{"name":"Department of Pathology and Immunology, Washington University School of Medicine, 660 South Euclid Ave., St. Louis, MO 63110"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitchell G","family":"Scott","sequence":"first","affiliation":[{"name":"Department of Pathology and Immunology, Washington University School of Medicine, 660 South Euclid Ave., St. Louis, MO 63110"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2005,2,1]]},"reference":[{"key":"2020022800534753800_R1","unstructured":"Fairbanks VF, Klee GG. Biochemical aspects of hematology. Burtis CA Ashwood ER eds. Tietz textbook of clinical chemistry, 3rd ed1999:1642-1710 WB Saunders Philadelphia. ."},{"key":"2020022800534753800_R2","unstructured":". National Committee for Clinical Laboratory Standards. Definitions of quantities and conventions related to blood pH and gas analysis; approved standard C12-5 [Report]1994 NCCLS Wayne, PA. ."},{"key":"2020022800534753800_R3","unstructured":". National Committee for Clinical Laboratory Standards. Fractional oxygen content and saturation, and related quantities in blood: terminology, measurement, and reporting; approved guideline C25-A [Report]1997 NCCLS Wayne, PA. ."},{"key":"2020022800534753800_R4","unstructured":"Scott MG, Heusel JW, LeGrys VA, Sigaard-Anderson O. Electrolytes and blood gases [blood gases and pH]. Burtis CA Ashwood ER eds. Tietz textbook of clinical chemistry, 3rd ed1999:1072-1088 WB Saunders Philadelphia. ."},{"key":"2020022800534753800_R5","doi-asserted-by":"crossref","unstructured":"Sinex JE. Pulse oximetry: principles and limitations. Am J Emerg Med1999;17:59-67.","DOI":"10.1016\/S0735-6757(99)90019-0"},{"key":"2020022800534753800_R6","doi-asserted-by":"crossref","unstructured":"Hampson NB. Pulse oximetry in severe carbon monoxide poisoning. Chest1998;114:1036-1041.","DOI":"10.1378\/chest.114.4.1036"},{"key":"2020022800534753800_R7","doi-asserted-by":"crossref","unstructured":"Pologe JA. Pulse oximetry: technical aspects of machine design. Tremper KK Barker SJ eds. International anesthesiology clinics: advances in oxygen monitoring1987:137-153 Little, Brown Boston. .","DOI":"10.1097\/00004311-198702530-00009"},{"key":"2020022800534753800_R8","doi-asserted-by":"crossref","unstructured":"Barker SJ, Tremper KK. The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous Po2. Anesthesiology1987;66:677-679.","DOI":"10.1097\/00000542-198705000-00014"},{"key":"2020022800534753800_R9","doi-asserted-by":"crossref","unstructured":"Wright RO. Pulse oximetry gap in carbon monoxide poisoning. Ann Emerg Med1998;31:525-526.","DOI":"10.1016\/S0196-0644(98)70268-9"},{"key":"2020022800534753800_R10","doi-asserted-by":"crossref","unstructured":"Bozeman WP, Myers RA, Barish RA. Confirmation of the pulse oximetry gap in carbon monoxide poisoning. Ann Emerg Med1997;30:608-611.","DOI":"10.1016\/S0196-0644(97)70077-5"},{"key":"2020022800534753800_R11","doi-asserted-by":"crossref","unstructured":"Bozeman WP. Pulse oximetry gap in carbon monoxide poisoning. Ann Emerg Med1998;31:656.","DOI":"10.1016\/S0196-0644(98)70223-9"},{"key":"2020022800534753800_R12","doi-asserted-by":"crossref","unstructured":"Buckley RG, Aks SE, Eshom JL, Rydman R, Schaider J, Shayne P. The pulse oximetry gap in carbon monoxide intoxication. Ann Emerg Med1994;24:252-255.","DOI":"10.1016\/S0196-0644(94)70137-7"},{"key":"2020022800534753800_R13","doi-asserted-by":"crossref","unstructured":"Barker SJ, Tremper KK, Hyatt J. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology1989;70:112-117.","DOI":"10.1097\/00000542-198901000-00021"},{"key":"2020022800534753800_R14","doi-asserted-by":"crossref","unstructured":"Konig MW, Dolinski SY. A 74-year-old woman with desaturation following surgery. Co-oximetry is the first step in making the diagnosis of dyshemoglobinemia. Chest2003;123:613-616.","DOI":"10.1378\/chest.123.2.613"},{"key":"2020022800534753800_R15","doi-asserted-by":"crossref","unstructured":"Gold NA, Bithoney WG. Methemoglobinemia due to ingestion of at most three pills of pyridium in a 2-year-old: case report and review. J Emerg Med2003;25:143-148.","DOI":"10.1016\/S0736-4679(03)00162-8"},{"key":"2020022800534753800_R16","doi-asserted-by":"crossref","unstructured":"Aepfelbacher FC, Breen P, Manning WJ. Methemoglobinemia and topical pharyngeal anesthesia. N Engl J Med2003;348:85-86.","DOI":"10.1056\/NEJM200301023480122"},{"key":"2020022800534753800_R17","doi-asserted-by":"crossref","unstructured":"White CD, Weiss LD. Varying presentations of methemoglobinemia: two cases. J Emerg Med1991;9(Suppl 1):45-49.","DOI":"10.1016\/0736-4679(91)90587-6"},{"key":"2020022800534753800_R18","doi-asserted-by":"crossref","unstructured":"Zijlstra WG, Buursma A, Meeuwsen-van der Roest WP. Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. Clin Chem1991;37:1633-1638.","DOI":"10.1093\/clinchem\/37.9.1633"},{"key":"2020022800534753800_R19","doi-asserted-by":"crossref","unstructured":"Rausch-Madison S, Mohsenifar Z. Methodologic problems encountered with cooximetry in methemoglobinemia. Am J Med Sci1997;314:203-206.","DOI":"10.1097\/00000441-199709000-00010"},{"key":"2020022800534753800_R20","doi-asserted-by":"crossref","unstructured":"Anderson ST, Hajduczek J, Barker SJ. Benzocaine-induced methemoglobinemia in an adult: accuracy of pulse oximetry with methemoglobinemia. Anesth Analg1988;67:1099-1101.","DOI":"10.1213\/00000539-198867110-00015"},{"key":"2020022800534753800_R21","doi-asserted-by":"crossref","unstructured":"Brunelle JA, Degtiarov AM, Moran RF, Race LA. Simultaneous measurement of total hemoglobin and its derivatives in blood using CO-oximeters: analytical principles; their application in selecting analytical wavelengths and reference methods; a comparison of the results of the choices made [Review]. Scand J Clin Lab Invest Suppl1996;224:47-69.","DOI":"10.3109\/00365519609088624"},{"key":"2020022800534753800_R22","unstructured":"Holbek CC. New developments in the measurement of CO-oximetry. Anesth Analg2002;94:S89-S92."},{"key":"2020022800534753800_R23","unstructured":"Salyer JW, Chatburn RL, Dolcini DM. Measures vs calculated oxygen saturation in a population of pediatric intensive care patients. Respir Care1989;34:342-348."},{"key":"2020022800534753800_R24","unstructured":"Price D. Methemoglobinemia. Goldfrank L Flomenbaum N Lewin N Howland M Hoffman R Nelson eds. Goldfrank\u2019s toxicologic emergencies, 7th ed2002:1438-1449 McGraw-Hill New York. ."},{"key":"2020022800534753800_R25","doi-asserted-by":"crossref","unstructured":"Wright RO, Lewander WJ, Woolf AD. Methemoglobinemia: etiology, pharmacology, and clinical management. Ann Emerg Med1999;34:646-656.","DOI":"10.1016\/S0196-0644(99)70167-8"},{"key":"2020022800534753800_R26","unstructured":"Jaffe ER, Hultquist DE. Cytochrome b5 reductase deficiency and enzymopenic hereditary methemoglobinemia. Scriver CR Beaudet AL Sly WS Valle D eds. The metabolic and molecular bases of inherited disease, 7th ed1995:2267-2280 McGraw-Hill New York. ."},{"key":"2020022800534753800_R27","doi-asserted-by":"crossref","unstructured":"Hsieh HS, Jaffe ER. The metabolism of methemoglobin in human erythrocytes. Surgenor DM eds. The red blood cell, 2nd ed1974:799-824 Academic Press New York. .","DOI":"10.1016\/B978-0-12-677202-9.50011-3"},{"key":"2020022800534753800_R28","doi-asserted-by":"crossref","unstructured":"Scott EM, Duncan IW, Ekstrand V. The reduced pyridine nucleotide dehydrogenases of human erythrocytes. J Biol Chem1965;240:481-485.","DOI":"10.1016\/S0021-9258(18)97676-3"},{"key":"2020022800534753800_R29","doi-asserted-by":"crossref","unstructured":"Olsen ML, McEvoy GK. Methemoglobinemia induced by topical anesthetics. Am J Hosp Pharm1981;38:89-93.","DOI":"10.1093\/ajhp\/38.1.89"},{"key":"2020022800534753800_R30","doi-asserted-by":"crossref","unstructured":"Horne MK, Waterman MR, Simon LM, Garriott JC, Foerster EH. Methemoglobinemia from sniffing butyl nitrite. Ann Intern Med1979;91:417-418.","DOI":"10.7326\/0003-4819-91-3-417"},{"key":"2020022800534753800_R31","doi-asserted-by":"crossref","unstructured":"Clifton J, II, Leikin JB. Methylene blue. Am J Ther2003;10:289-291.","DOI":"10.1097\/00045391-200307000-00009"},{"key":"2020022800534753800_R32","doi-asserted-by":"crossref","unstructured":"Modarai B, Kapadia YK, Kerins M, Terris J. Methylene blue: a treatment for severe methaemoglobinaemia secondary to misuse of amyl nitrite. Emerg Med J2002;19:270-271.","DOI":"10.1136\/emj.19.3.270"},{"key":"2020022800534753800_R33","unstructured":"Howland MA. Methylene blue. Goldfrank L Flomenbaum N Lewin N Howland M Hoffman R Nelson eds. Goldfrank\u2019s toxicologic emergencies, 7th ed2002:1450-1452 McGraw-Hill New York. ."},{"key":"2020022800534753800_R34","doi-asserted-by":"crossref","unstructured":"Coleman MD, Coleman NA. Drug-induced methaemoglobinaemia. Treatment issues [Review]. Drug Saf1996;14:394-405.","DOI":"10.2165\/00002018-199614060-00005"},{"key":"2020022800534753800_R35","doi-asserted-by":"crossref","unstructured":"Bolyai JZ, Smith RP, Gray CT. Ascorbic acid and chemically induced methemoglobinemias. Toxicol Appl Pharmacol1972;21:176-185.","DOI":"10.1016\/0041-008X(72)90060-9"},{"key":"2020022800534753800_R36","doi-asserted-by":"crossref","unstructured":"Stambach T, Haire K, Soni N, Booth J. Saturday night blue\u2014a case of near fatal poisoning from the abuse of amyl nitrite. J Accid Emerg Med1997;14:339-340.","DOI":"10.1136\/emj.14.5.339"},{"key":"2020022800534753800_R37","doi-asserted-by":"crossref","unstructured":"Machabert R, Testud F, Descotes J. Methemoglobinemia due to amyl nitrite inhalation: a case report. Hum Exp Toxicol1994;13:313-314.","DOI":"10.1177\/096032719401300505"},{"key":"2020022800534753800_R38","doi-asserted-by":"crossref","unstructured":"Ward KE, McCarthy MW. Dapsone-induced methemoglobinemia. Ann Pharmacother1998;32:549-553.","DOI":"10.1345\/aph.17003"},{"key":"2020022800534753800_R39","doi-asserted-by":"crossref","unstructured":"Chawla R, Kundra P, Bhattacharya A. Asymptomatic methaemoglobinaemia and its implications. Acta Anaesthesiol Scand1998;42:736-738.","DOI":"10.1111\/j.1399-6576.1998.tb05311.x"},{"key":"2020022800534753800_R40","doi-asserted-by":"crossref","unstructured":"Falkenhahn M, Kannan S, O\u2019Kane M. Unexplained acute severe methaemoglobinaemia in a young adult. Br J Anaesth2001;86:278-280.","DOI":"10.1093\/bja\/86.2.278"},{"key":"2020022800534753800_R41","doi-asserted-by":"crossref","unstructured":"Mandrell BN, McCormick JN. Dapsone-induced methemoglobinemia in pediatric oncology patients: case examples. J Pediatr Oncol Nurs2001;18:224-228.","DOI":"10.1053\/jpon.2007.26876"},{"key":"2020022800534753800_R42","unstructured":"Lewis S, Clark P. Diagnostic confusion caused by dapsone-induced methaemoglobinaemia. Br J Anaesth2001;87:802-803."},{"key":"2020022800534753800_R43","doi-asserted-by":"crossref","unstructured":"Rodriguez LF, Smolik LM, Zbehlik AJ. Benzocaine-induced methemoglobinemia: report of a severe reaction and review of the literature. Ann Pharmacother1994;28:643-649.","DOI":"10.1177\/106002809402800515"},{"key":"2020022800534753800_R44","doi-asserted-by":"crossref","unstructured":"Maher P. Methemoglobinemia: an unusual complication of topical anesthesia. Gastroenterol Nurs1998;21:173-175.","DOI":"10.1097\/00001610-199807000-00004"},{"key":"2020022800534753800_R45","doi-asserted-by":"crossref","unstructured":"Khan NA, Kruse JA. Methemoglobinemia induced by topical anesthesia: a case report and review. Am J Med Sci1999;318:415-418.","DOI":"10.1016\/S0002-9629(15)40667-6"},{"key":"2020022800534753800_R46","doi-asserted-by":"crossref","unstructured":"Lee JS, Mendez PA, Douglass HO, Jr. Unexpected cyanosis in the surgical patient. Surg Endosc2000;14:595.","DOI":"10.1007\/s004640020083"},{"key":"2020022800534753800_R47","doi-asserted-by":"crossref","unstructured":"Udeh C, Bittikofer J, Sum-Ping ST. Severe methemoglobinemia on reexposure to benzocaine. J Clin Anesth2001;13:128-130.","DOI":"10.1016\/S0952-8180(01)00222-7"},{"key":"2020022800534753800_R48","doi-asserted-by":"crossref","unstructured":"Ramsakal A, Lezama JL, Adelman HM. A potentially fatal effect of topical anesthesia. Hosp Pract (Off Ed)2001;36:13-14.","DOI":"10.1080\/21548331.2001.11444115"},{"key":"2020022800534753800_R49","doi-asserted-by":"crossref","unstructured":"Abdallah HY, Shah SA. Methemoglobinemia induced by topical benzocaine: a warning for the endoscopist. Endoscopy2002;34:730-734.","DOI":"10.1055\/s-2002-33450"},{"key":"2020022800534753800_R50","doi-asserted-by":"crossref","unstructured":"Robinson P. Benzocaine-induced methemoglobinemia. Nursing2003;33(3):88.","DOI":"10.1097\/00152193-200303000-00059"},{"key":"2020022800534753800_R51","doi-asserted-by":"crossref","unstructured":"Carlson G, Negri E, McGrew A, Plaisier B. Two cases of methemoglobinemia from the use of topical anesthetics. J Emerg Nurs2003;29:106-108.","DOI":"10.1067\/men.2003.57"},{"key":"2020022800534753800_R52","doi-asserted-by":"crossref","unstructured":"Vidyarthi V, Manda R, Ahmed A, Khosla S, Lubell DL. Severe methemoglobinemia after transesophageal echocardiography. Am J Ther2003;10:225-227.","DOI":"10.1097\/00045391-200305000-00010"},{"key":"2020022800534753800_R53","unstructured":"Wintrobe MM, Lee GR. Lee GR eds. Wintrobe\u2019s clinical hematology1999:1046-1055 Williams & Wilkins Baltimore. ."},{"key":"2020022800534753800_R54","unstructured":"Feig SA. Methemoglobinemia. Nathan DG Oski FA eds. Hematology of infancy and childhood1981:654-686 WB Saunders Philadelphia. ."},{"key":"2020022800534753800_R55","doi-asserted-by":"crossref","unstructured":"Lukens JN. Landmark perspective: the legacy of well-water methemoglobinemia. JAMA1987;257:2793-2795.","DOI":"10.1001\/jama.257.20.2793"},{"key":"2020022800534753800_R56","doi-asserted-by":"crossref","unstructured":"Dolan MA, Luban NL. Methemoglobinemia in two children: disparate etiology and treatment. Pediatr Emerg Care1987;3:171-175.","DOI":"10.1097\/00006565-198709000-00011"},{"key":"2020022800534753800_R57","unstructured":"Knobeloch L, Proctor M. Eight blue babies. WMJ2001;100:43-47."},{"key":"2020022800534753800_R58","doi-asserted-by":"crossref","unstructured":"Percy MJ, Gillespie MJ, Savage G, Hughes AE, McMullin MF, Lappin TR. Familial idiopathic methemoglobinemia revisited: original cases reveal 2 novel mutations in NADH-cytochrome b5 reductase. Blood2002;100:3447-3449.","DOI":"10.1182\/blood-2002-05-1405"},{"key":"2020022800534753800_R59","doi-asserted-by":"crossref","unstructured":"Li AM, Wong W, Chan MH, Ma KC, Law LK, van Zwieten R, et al. Normal pulse oximeter reading in a cyanotic infant. J Paediatr Child Health2001;37:94-95.","DOI":"10.1046\/j.1440-1754.2001.00614.x"},{"key":"2020022800534753800_R60","doi-asserted-by":"crossref","unstructured":"Da-Silva SS, Sajan IS, Underwood JP, III. Congenital methemoglobinemia: a rare cause of cyanosis in the newborn\u2014a case report. Pediatrics2003;112:e158-e161.","DOI":"10.1542\/peds.112.2.e158"},{"key":"2020022800534753800_R61","doi-asserted-by":"crossref","unstructured":"Hurford WE, Kratz A. Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Case 23-2004. A 50-year-old woman with low oxygen saturation. N Engl J Med2004;351:380-387.","DOI":"10.1056\/NEJMcpc049013"},{"key":"2020022800534753800_R62","unstructured":"Beutler E. Methemoglobinemia and other causes of cyanosis. Beutler E Lictman MA Caller BS Kipps TJ eds. Williams hematology, 5th ed1995:654-663 McGraw-Hill New York. ."},{"key":"2020022800534753800_R63","unstructured":"Kim HC, Adachi K, Schwartz E. Separation of hemoglobins. Beutler E Lictman MA Caller BS Kipps TJ eds. Williams Hematology, 5th ed1995:L35-L42 McGraw-Hill New York. ."}],"container-title":["Clinical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/clinchem\/article-pdf\/51\/2\/434\/32681879\/clinchem0434.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/clinchem\/article-pdf\/51\/2\/434\/32681879\/clinchem0434.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,27]],"date-time":"2021-06-27T02:22:01Z","timestamp":1624760521000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/clinchem\/article\/51\/2\/434\/5629640"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,2,1]]},"references-count":63,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2005,2,1]]},"published-print":{"date-parts":[[2005,2,1]]}},"URL":"https:\/\/doi.org\/10.1373\/clinchem.2004.035154","relation":{},"ISSN":["0009-9147","1530-8561"],"issn-type":[{"value":"0009-9147","type":"print"},{"value":"1530-8561","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2005,2,1]]},"published":{"date-parts":[[2005,2,1]]}}}