{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T15:52:18Z","timestamp":1770997938825,"version":"3.50.1"},"reference-count":31,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2006,4,1]],"date-time":"2006-04-01T00:00:00Z","timestamp":1143849600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2006,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Background: We sought to develop a technique with the potential to partly replace current methods of analysis based on blood draws. To achieve this goal, we developed an in vivo microextraction technique that is faster than conventional methods, interferes minimally with the investigated system, minimizes errors associated with sample preparation, and limits exposure to hazardous biological samples.<\/jats:p>\n               <jats:p>Methods: Solid-phase microextraction devices based on hydrophilic polypyrrole and polyethylene glycol coatings were used for direct extraction of drugs from the flowing blood of beagle dogs, over a period of 8 h. The drugs extracted on the probes were subsequently quantified by liquid chromatography coupled to tandem mass spectrometry. Two calibration strategies\u2014external and standard on the fiber\u2014were used to correlate the amount extracted with the in vivo concentration.<\/jats:p>\n               <jats:p>Results: Diazepam and its metabolites were successfully monitored over the course of a pharmacokinetic study, repeated 3 times on 3 beagles. The fast microextraction technique was validated by comparison with conventional plasma analysis, and a correlation factor of 0.99 was obtained. In addition to total concentrations, the method was useful for determining free drug concentrations.<\/jats:p>\n               <jats:p>Conclusions: The proposed technique has several advantages and is suitable for fast clinical analyses. This approach could be used not only for drugs, but for any other endogenous or exogenous compounds.<\/jats:p>","DOI":"10.1373\/clinchem.2005.064758","type":"journal-article","created":{"date-parts":[[2006,2,24]],"date-time":"2006-02-24T01:59:09Z","timestamp":1140746349000},"page":"708-715","source":"Crossref","is-referenced-by-count":102,"title":["Fast In Vivo Microextraction: A New Tool for Clinical Analysis"],"prefix":"10.1093","volume":"52","author":[{"given":"Florin Marcel","family":"Musteata","sequence":"first","affiliation":[{"name":"Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mihaela L","family":"Musteata","sequence":"first","affiliation":[{"name":"Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janusz","family":"Pawliszyn","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2006,4,1]]},"reference":[{"key":"2020022801315161700_R1","doi-asserted-by":"crossref","unstructured":"Walt DR. Chemistry: miniature analytical methods for medical diagnostics. Science2005;308:217-219.","DOI":"10.1126\/science.1108161"},{"key":"2020022801315161700_R2","doi-asserted-by":"crossref","unstructured":"Tseng W-C, Sun Y-C, Lee C-F, Yang M-H, Huang Y-L. Continuous in vivo monitoring of blood diffusible calcium using on-line microdialysis sampling coupled with flame atomic absorption spectrometry. Anal Sci2005;21:225-229.","DOI":"10.2116\/analsci.21.225"},{"key":"2020022801315161700_R3","doi-asserted-by":"crossref","unstructured":"Brunner M, Schmiedberger A, Schmid R, Jager D, Piegler E, Eichler HG, et al. Direct assessment of peripheral pharmacokinetics in humans: comparison between cantharides blister fluid sampling, in vivo microdialysis and saliva sampling. Br J Clin Pharmacol1998;46:425-431.","DOI":"10.1046\/j.1365-2125.1998.00805.x"},{"key":"2020022801315161700_R4","doi-asserted-by":"crossref","unstructured":"Benfeldt E, Serup J, Menne T. Microdialysis vs. suction blister technique for in vivo sampling of pharmacokinetics in the human dermis. Acta Derm Venereol1999;79:338-342.","DOI":"10.1080\/000155599750010210"},{"key":"2020022801315161700_R5","doi-asserted-by":"crossref","unstructured":"Dostalova I, Pacak K, Nedvidkova J. Application of in vivo microdialysis to measure leptin concentrations in adipose tissue. Int J Biol Macromol2003;32:205-208.","DOI":"10.1016\/S0141-8130(03)00055-2"},{"key":"2020022801315161700_R6","doi-asserted-by":"crossref","unstructured":"Kennedy RT, Thompson JE, Vickroy TW. In vivo monitoring of amino acids by direct sampling of brain extracellular fluid at ultralow flow rates and capillary electrophoresis. J Neurosci Methods2002;114:39-49.","DOI":"10.1016\/S0165-0270(01)00506-4"},{"key":"2020022801315161700_R7","doi-asserted-by":"crossref","unstructured":"Leegsma-Vogt G, Janle E, Ash SR, Venema K, Korf J. Utilization of in vivo ultrafiltration in biomedical research and clinical applications. Life Sci2003;73:2005-2018.","DOI":"10.1016\/S0024-3205(03)00569-1"},{"key":"2020022801315161700_R8","doi-asserted-by":"crossref","unstructured":"Fogt EJ. Continuous ex vivo and in vivo monitoring with chemical sensors. Clin Chem1990;36:1573-1580.","DOI":"10.1093\/clinchem\/36.8.1573"},{"key":"2020022801315161700_R9","doi-asserted-by":"crossref","unstructured":"Robinson DL, Venton BJ, Heien MLAV, Wightman RM. Detecting subsecond dopamine release with fast-scan cyclic voltammetry in vivo. Clin Chem2003;49:1763-1773.","DOI":"10.1373\/49.10.1763"},{"key":"2020022801315161700_R10","doi-asserted-by":"crossref","unstructured":"Jianrong C, Yuqing M, Nongyue H, Xiaohua W, Sijiao L. Nanotechnology and biosensors. Biotechnol Adv2004;22:505-518.","DOI":"10.1016\/j.biotechadv.2004.03.004"},{"key":"2020022801315161700_R11","doi-asserted-by":"crossref","unstructured":"Jia G, Wang H, Yan L, Wang X, Pei R, Yan T, et al. Cytotoxicity of carbon nanomaterials: single-wall nanotube, multi-wall nanotube, and fullerene. Environ Sci Technol2005;39:1378-1383.","DOI":"10.1021\/es048729l"},{"key":"2020022801315161700_R12","unstructured":"Shvedova AA, Murray AR, Johnson VJ, Gorelik O, Arepalli S, Hubbs A, et al. Comparative toxicity of nanomaterials in vitro and in vivo. [Abstract]Proceedings of the 229th American Chemical Society National Meeting, San Diego, CA, March 13\u201317, 20052005 American Chemical Society Washington, DC. ."},{"key":"2020022801315161700_R13","doi-asserted-by":"crossref","unstructured":"Sieg A, Guy RH, Delgado-Charro MB. Noninvasive glucose monitoring by reverse iontophoresis in vivo: application of the internal standard concept. Clin Chem2004;50:1383-1390.","DOI":"10.1373\/clinchem.2004.032862"},{"key":"2020022801315161700_R14","doi-asserted-by":"crossref","unstructured":"Leboulanger B, Aubry J-M, Bondolfi G, Guy RH, Delgado-Charro MB. Lithium monitoring by reverse iontophoresis in vivo. Clin Chem2004;50:2091-2100.","DOI":"10.1373\/clinchem.2004.034249"},{"key":"2020022801315161700_R15","doi-asserted-by":"crossref","unstructured":"Li GL, Van Steeg TJ, Putter H, Van Der Spek J, Pavel S, Danhof M, et al. Cutaneous side-effects of transdermal iontophoresis with and without surfactant pretreatment: a single-blinded, randomized controlled trial. Br J Dermatol2005;153:404-412.","DOI":"10.1111\/j.1365-2133.2005.06741.x"},{"key":"2020022801315161700_R16","doi-asserted-by":"crossref","unstructured":"Pawliszyn J. New developments and applications of solvent-free sampling and sample preparation technologies for the investigation of living systems. Aust J Chem2003;56:155-158.","DOI":"10.1071\/CH02188"},{"key":"2020022801315161700_R17","doi-asserted-by":"crossref","unstructured":"Lord HL, Grant RP, Walles M, Incledon B, Fahie B, Pawliszyn JB. Development and evaluation of a solid-phase microextraction probe for in vivo pharmacokinetic studies. Anal Chem2003;75:5103-5115.","DOI":"10.1021\/ac0343230"},{"key":"2020022801315161700_R18","unstructured":"Pawliszyn J eds. Sampling and sample preparation for field and laboratory: fundamentals and new directions in sample preparation. Comprehensive analytical chemistry2002;Vol. 37:1131pp Elsevier Science BV Amsterdam. ."},{"key":"2020022801315161700_R19","doi-asserted-by":"crossref","unstructured":"Chen Y, Pawliszyn J. Kinetics and the on-site application of standards in a solid-phase microextraction fiber. Anal Chem2004;76:5807-5815.","DOI":"10.1021\/ac0495081"},{"key":"2020022801315161700_R20","unstructured":"Hsu Y-L, Rose S, Furton KG. The determination of the free fraction of protein bound drugs using valproic acid in clinical samples by solid phase microextraction (SPME) GC\/MS. [Abstract]Proceedings of the 223rd American Chemical Society National Meeting, April 7\u201311, 20022002 American Chemical Society Orlando, FL. Washington, DC. ."},{"key":"2020022801315161700_R21","doi-asserted-by":"crossref","unstructured":"Krogh M, Johansen K, Tonnesen F, Rasmussen KE. Solid-phase microextraction for the determination of the free concentration of valproic acid in human plasma by capillary gas chromatography. J Chromatogr B Biomed Appl1995;673:299-305.","DOI":"10.1016\/0378-4347(95)00273-8"},{"key":"2020022801315161700_R22","doi-asserted-by":"crossref","unstructured":"Musteata FM, Pawliszyn J. Study of ligand-receptor binding using SPME: investigation of receptor, free, and total ligand concentrations. J Proteome Res2005;4:789-800.","DOI":"10.1021\/pr049768z"},{"key":"2020022801315161700_R23","doi-asserted-by":"crossref","unstructured":"Musteata FM, Pawliszyn J. Assay of stability, free and total concentration of chlorhexidine in saliva by solid phase microextraction. J Pharm Biomed Anal2005;37:1015-1024.","DOI":"10.1016\/j.jpba.2004.09.055"},{"key":"2020022801315161700_R24","doi-asserted-by":"crossref","unstructured":"Haase V, Beck F. Electrodeposition of N-substituted polypyrroles on iron and the CIPL strategy. Electrochim Acta1994;39:1195-1205.","DOI":"10.1016\/0013-4686(94)E0037-Z"},{"key":"2020022801315161700_R25","doi-asserted-by":"crossref","unstructured":"Iroh JO, Su W. Corrosion performance of polypyrrole coating applied to low carbon steel by an electrochemical process. Electrochim Acta2000;46:15-24.","DOI":"10.1016\/S0013-4686(00)00519-3"},{"key":"2020022801315161700_R26","doi-asserted-by":"crossref","unstructured":"De Giglio E, Guascito MR, Sabbatini L, Zambonin G. Electropolymerization of pyrrole on titanium substrates for the future development of new biocompatible surfaces. Biomaterials2001;22:2609-2616.","DOI":"10.1016\/S0142-9612(00)00449-X"},{"key":"2020022801315161700_R27","doi-asserted-by":"crossref","unstructured":"Sharma S, Desai TA. Nanostructured antifouling poly(ethylene glycol) films for silicon-based microsystems. J Nanosci Nanotechnol2005;5:235-243.","DOI":"10.1166\/jnn.2005.030"},{"key":"2020022801315161700_R28","unstructured":"Lord HL. Development of SPME probes for in-vivo applications2005 University of Waterloo Waterloo, Ontario, Canada. [PhD dissertation]."},{"key":"2020022801315161700_R29","unstructured":"Pawliszyn J. Solid-phase microextraction: theory and practice1997:275pp Wiley-VCH New York. ."},{"key":"2020022801315161700_R30","doi-asserted-by":"crossref","unstructured":"Jones AW, Larsson H. Distribution of diazepam and nordiazepam between plasma and whole blood and the influence of hematocrit. Ther Drug Monit2004;26:380-385.","DOI":"10.1097\/00007691-200408000-00007"},{"key":"2020022801315161700_R31","unstructured":"Loescher W, Frey HH. Pharmacokinetics of diazepam in the dog. Arch Int Pharmacol Ther1981;254:180-195."}],"container-title":["Clinical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/clinchem\/article-pdf\/52\/4\/708\/32687031\/clinchem0708.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/clinchem\/article-pdf\/52\/4\/708\/32687031\/clinchem0708.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,28]],"date-time":"2020-02-28T06:34:02Z","timestamp":1582871642000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/clinchem\/article\/52\/4\/708\/5626968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,4,1]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2006,4,1]]},"published-print":{"date-parts":[[2006,4,1]]}},"URL":"https:\/\/doi.org\/10.1373\/clinchem.2005.064758","relation":{},"ISSN":["0009-9147","1530-8561"],"issn-type":[{"value":"0009-9147","type":"print"},{"value":"1530-8561","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2006,4,1]]},"published":{"date-parts":[[2006,4,1]]}}}