{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T01:49:23Z","timestamp":1774662563408,"version":"3.50.1"},"reference-count":18,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[1999,6,1]],"date-time":"1999-06-01T00:00:00Z","timestamp":928195200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Chest"],"published-print":{"date-parts":[[1999,6]]},"DOI":"10.1378\/chest.115.6.1641","type":"journal-article","created":{"date-parts":[[2003,6,14]],"date-time":"2003-06-14T00:09:19Z","timestamp":1055549359000},"page":"1641-1645","source":"Crossref","is-referenced-by-count":18,"title":["Diagnosis of Nosocomial Pneumonia in Cancer Patients Undergoing Mechanical Ventilation"],"prefix":"10.1016","volume":"115","author":[{"given":"Michel","family":"Casetta","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Blot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sami","family":"Antoun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"Leclercq","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cyrille","family":"Tancr\u00e8de","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7oise","family":"Doyon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e9rard","family":"Nitenberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1378\/chest.115.6.1641_bib1","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1001\/jama.1996.03530350048033","article-title":"Nosocomial pneumonia and mortality among patients in intensive care units","volume":"275","author":"Fagon","year":"1996","journal-title":"JAMA"},{"key":"10.1378\/chest.115.6.1641_bib2","first-page":"1711","article-title":"Hospital-acquired pneumonia in adults: diagnosis, assessment of severity, initial antimicrobial therapy, and preventative strategies: a consensus statement","volume":"153","author":"American Thoracic Society","year":"1995","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1378\/chest.115.6.1641_bib3","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1136\/thx.50.11.1128","article-title":"Nosocomial pneumonia during mechanical ventilation: problems with diagnostic criteria","volume":"50","author":"Brun-Buisson","year":"1995","journal-title":"Thorax"},{"key":"10.1378\/chest.115.6.1641_bib4","first-page":"337","article-title":"A fiberoptic bronchoscopy technique to obtain uncontaminated lower airway secretions for bacterial culture","volume":"119","author":"Wimberley","year":"1979","journal-title":"Am Rev Respir Dis"},{"issue":"suppl 1","key":"10.1378\/chest.115.6.1641_bib5","doi-asserted-by":"crossref","first-page":"557s","DOI":"10.1378\/chest.102.5_Supplement_1.557S","article-title":"The standardization of bronchoscopic techniques for ventilator-associated pneumonia","volume":"102","author":"Meduri","year":"1992","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib6","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1378\/chest.104.5.1548","article-title":"Effects of consecutive protected specimen brushing and bronchoalveolar lavage on gas exchange and hemodynamics in ventilated patients","volume":"104","author":"Papazian","year":"1993","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib7","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1097\/00000542-198911000-00010","article-title":"A prospective study of protected bronchoalveolar lavage in the diagnosis of nosocomial pneumonia","volume":"71","author":"Rouby","year":"1989","journal-title":"Anesthesiology"},{"key":"10.1378\/chest.115.6.1641_bib8","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1378\/chest.108.1.203","article-title":"A comparison of bronchoscopic vs blind protected specimen brush sampling in patients with suspected ventilator-associated pneumonia","volume":"108","author":"Marik","year":"1995","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib9","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1164\/ajrccm\/143.5_Pt_1.1055","article-title":"Diagnosis of nosocomial pneumonia in mechanically ventilated patients: comparison of a plugged telescoping catheter with the protected specimen brush","volume":"143","author":"Pham","year":"1991","journal-title":"Am Rev Respir Dis"},{"key":"10.1378\/chest.115.6.1641_bib10","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1378\/chest.80.3.254","article-title":"Diagnosis of nosocomial bacterial pneumonia in acute, diffuse lung injury","volume":"80","author":"Andrews","year":"1981","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib11","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1164\/ajrccm\/139.4.877","article-title":"Prospective analysis of 52 episodes with use of a protected specimen brush and quantitative culture techniques","volume":"139","author":"Fagon","year":"1989","journal-title":"Am Rev Respir Dis"},{"key":"10.1378\/chest.115.6.1641_bib12","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1093\/infdis\/155.5.862","article-title":"Diagnosing bacterial respiratory infection by bronchoalveolar lavage","volume":"155","author":"Kahn","year":"1987","journal-title":"J Infect Dis"},{"key":"10.1378\/chest.115.6.1641_bib13","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1097\/00003246-198411000-00012","article-title":"A simplified acute physiology score for ICU patients","volume":"12","author":"Le Gall","year":"1984","journal-title":"Crit Care Med"},{"key":"10.1378\/chest.115.6.1641_bib14","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/S1164-6756(97)80067-9","article-title":"Technical evaluation of blind protected bronchial sampling using a plugged telescoping catheter in intensive care unit","volume":"6","author":"Girault","year":"1997","journal-title":"R\u00e9an Urg"},{"key":"10.1378\/chest.115.6.1641_bib15","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1378\/chest.108.6.1632","article-title":"Reappraisal of distal diagnostic testing in the diagnosis of ICU-acquired pneumonia","volume":"108","author":"Timsit","year":"1995","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib16","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1164\/ajrccm\/148.1.138","article-title":"Diagnostic efficiency of endotracheal aspirate with quantitative bacterial cultures in intubated patients with suspected pneumonia: comparison with the protected specimen brush","volume":"148","author":"Marquette","year":"1993","journal-title":"Am Rev Respir Dis"},{"key":"10.1378\/chest.115.6.1641_bib17","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1378\/chest.110.1.172","article-title":"Usefulness of airway visualization in the diagnosis of nosocomial pneumonia in ventilated patients","volume":"110","author":"Timsit","year":"1996","journal-title":"Chest"},{"key":"10.1378\/chest.115.6.1641_bib18","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1164\/ajrccm.150.2.8049849","article-title":"Invasive diagnostic testing is not needed routinely to manage suspected ventilator-associated pneumonia","volume":"150","author":"Niederman","year":"1994","journal-title":"Am J Respir Crit Care Med"}],"container-title":["Chest"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369215383021?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369215383021?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T19:58:12Z","timestamp":1553111892000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0012369215383021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,6]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1999,6]]}},"alternative-id":["S0012369215383021"],"URL":"https:\/\/doi.org\/10.1378\/chest.115.6.1641","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[1999,6]]}}}