{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T12:45:47Z","timestamp":1777985147912,"version":"3.51.4"},"reference-count":19,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[1999,9,1]],"date-time":"1999-09-01T00:00:00Z","timestamp":936144000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,2,3]],"date-time":"2017-02-03T00:00:00Z","timestamp":1486080000000},"content-version":"vor","delay-in-days":6365,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","journal.chestnet.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Chest"],"published-print":{"date-parts":[[1999,9]]},"DOI":"10.1378\/chest.116.3.660","type":"journal-article","created":{"date-parts":[[2003,6,14]],"date-time":"2003-06-14T00:09:19Z","timestamp":1055549359000},"page":"660-666","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"title":["Cardiogenic Oscillations on the Airflow Signal During Continuous Positive Airway Pressure as a Marker of Central Apnea"],"prefix":"10.1016","volume":"116","author":[{"given":"Indu","family":"Ayappa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert G.","family":"Norman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David M.","family":"Rapoport","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1378\/chest.116.3.660_bib1","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1183\/09031936.93.04060660","article-title":"Occurrence of breathing disorders during CPAP administration in obstructive sleep apnoea syndrome","volume":"4","author":"Marrone","year":"1991","journal-title":"Eur Respir J"},{"key":"10.1378\/chest.116.3.660_bib2","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1164\/ajrccm.154.3.8810613","article-title":"Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome","volume":"154","author":"Teschler","year":"1996","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1378\/chest.116.3.660_bib3","doi-asserted-by":"crossref","first-page":"588","DOI":"10.7326\/0003-4819-127-8_Part_1-199710150-00002","article-title":"Efficacy of automatic continuous positive airway pressure therapy that uses an estimated required pressure in the treatment of the obstructive sleep apnea syndrome","volume":"127","author":"Series","year":"1997","journal-title":"Ann Intern Med"},{"key":"10.1378\/chest.116.3.660_bib4","doi-asserted-by":"crossref","first-page":"S131","DOI":"10.1093\/sleep\/19.suppl_9.S131","article-title":"Nasal continuous positive pressure treatment: current realities and future","volume":"19","author":"Berthon-Jones","year":"1996","journal-title":"Sleep"},{"key":"10.1378\/chest.116.3.660_bib5","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/S0954-6111(98)90399-7","article-title":"Appearance of central apnoea in a patient treated by auto-CPAP for obstructive sleep apnoea","volume":"92","author":"Boudewyns","year":"1998","journal-title":"Respir Med"},{"key":"10.1378\/chest.116.3.660_bib6","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1378\/chest.90.2.165","article-title":"Reversal of central sleep apnea using nasal CPAP","volume":"90","author":"Issa","year":"1996","journal-title":"Chest"},{"key":"10.1378\/chest.116.3.660_bib7","first-page":"384","article-title":"Pulsatile gas flow in bronchi caused by the heart beat","volume":"58","author":"West","year":"1961","journal-title":"J Appl Physiol"},{"key":"10.1378\/chest.116.3.660_bib8","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1152\/jappl.1998.84.2.661","article-title":"Cardiogenic oscillation during single-breath tests performed in microgravity","volume":"84","author":"Lauzon","year":"1998","journal-title":"J Appl Physiol"},{"key":"10.1378\/chest.116.3.660_bib9","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/0034-5687(94)00082-B","article-title":"Determination of DLCO and cardiac output from expired gas slopes with cardiogenic oscillations","volume":"99","author":"Brenner","year":"1995","journal-title":"Respir Physiol"},{"key":"10.1378\/chest.116.3.660_bib10","series-title":"Principles and practice of sleep medicine","first-page":"984","article-title":"Monitoring respiratory and cardiac function","author":"Kryger","year":"1994"},{"key":"10.1378\/chest.116.3.660_bib11","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1093\/sleep\/18.8.651","article-title":"The assessment of upper airway patency during apnea using cardiogenic oscillations in the airflow signal","volume":"18","author":"Morrell","year":"1995","journal-title":"Sleep"},{"key":"10.1378\/chest.116.3.660_bib12","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1164\/ajrccm.154.5.8912777","article-title":"Use of a magnified cardiac waveform oscillation to diagnose infant apnea: a theoretical and clinical evaluation","volume":"154","author":"Lemke","year":"1996","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1378\/chest.116.3.660_bib13","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1164\/ajrccm.157.2.9612125","article-title":"Evidence of a critical period of airway instability during central apneas in preterm infants","volume":"57","author":"Lemke","year":"1998","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1378\/chest.116.3.660_bib14","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1136\/adc.55.1.22","article-title":"Upper airway obstruction and apnea in preterm babies","volume":"55","author":"Milner","year":"1990","journal-title":"Arch Dis Child"},{"key":"10.1378\/chest.116.3.660_bib15","series-title":"Atlas of sleep medicine","author":"Shepard","year":"1991"},{"key":"10.1378\/chest.116.3.660_bib16","series-title":"A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects","article-title":"Rechtschaffen","year":"1968"},{"key":"10.1378\/chest.116.3.660_bib17","first-page":"59","article-title":"Chest wall motion in sleep apnea","volume":"130","author":"Staats","year":"1984","journal-title":"Am Rev Respir Dis"},{"key":"10.1378\/chest.116.3.660_bib18","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1378\/chest.86.6.839","article-title":"Nasal CPAP effect on patterns of sleep apnea","volume":"86","author":"Sanders","year":"1984","journal-title":"Chest"},{"key":"10.1378\/chest.116.3.660_bib19","first-page":"83","article-title":"Endoscopic observations of the pharyngeal airway during treatment of obstructive sleep apnea with nasal continuous positive pressure: a pneumatic splint","volume":"144","author":"Popper","year":"1986","journal-title":"West J Med"}],"container-title":["Chest"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369216352825?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369216352825?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T04:33:31Z","timestamp":1671770011000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0012369216352825"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,9]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1999,9]]}},"alternative-id":["S0012369216352825"],"URL":"https:\/\/doi.org\/10.1378\/chest.116.3.660","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[1999,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cardiogenic Oscillations on the Airflow Signal During Continuous Positive Airway Pressure as a Marker of Central Apnea","name":"articletitle","label":"Article Title"},{"value":"Chest","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1378\/chest.116.3.660","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 1999 The American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}