{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T21:15:18Z","timestamp":1788470118854,"version":"build-2803163510"},"reference-count":34,"publisher":"Veterinary World","license":[{"start":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T00:00:00Z","timestamp":1744070400000},"content-version":"vor","delay-in-days":7,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T00:00:00Z","timestamp":1744070400000},"content-version":"tdm","delay-in-days":7,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100022271","name":"Faculty of Veterinary Medicine, Kasetsart University","doi-asserted-by":"publisher","award":["ID vetTVP 2021-12"],"award-info":[{"award-number":["ID vetTVP 2021-12"]}],"id":[{"id":"10.13039\/501100022271","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet World"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:p>Background and Aim: Canine femoral fractures are prevalent in veterinary medicine, necessitating effective fixation methods to ensure stability and promote healing. Conventional bone plate fixation methods, including non-locking and locking plates, have inherent limitations, such as periosteal damage and mechanical failure. This study aims to evaluate the biomechanical performance of three fixation methods \u2013 non-locking bone plates, locking bone plates, and a novel double-rod clamp internal fixation system \u2013 using finite element analysis (FEA).\n\nMaterials and Methods: A computed tomography-based canine femur model was created to simulate a midshaft commin-uted fracture with a 20 mm gap. Three fixation configurations were modeled: A non-locking bone plate, a locking bone plate, and a double-rod clamp system. FEA was performed to assess implant stress and proximal fragment displacement under physiological axial loading. Mesh refinement and multiple loading conditions were incorporated to enhance computational accuracy.\n\nResults: The non-locking bone plate exhibited the highest implant stress (1160.22 MPa), surpassing the material yield strength and indicating a risk of mechanical failure. The double-rod clamp system demonstrated lower stress (628.34 MPa), whereas the locking bone plate had the lowest stress (446.63 MPa). Proximal fragment displacement was highest in the non-locking bone plate (2.37 mm), followed by the double-rod clamp system (0.99 mm), with the locking bone plate exhibiting the least displacement (0.34 mm), suggesting superior stability.\n\nConclusion: The double-rod clamp system emerged as a promising alternative, offering a balance between stability and stress distribution while minimizing periosteal damage. While the locking bone plate provided the greatest stability, the double-rod clamp fixation demonstrated favorable mechanical properties and could serve as a cost-effective and minimally invasive alternative in veterinary orthopedics.\n\nKeywords: bone plate, canine, clamp, femoral fracture, finite element analysis.<\/jats:p>","DOI":"10.14202\/vetworld.2025.773-781","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T10:21:58Z","timestamp":1744107718000},"page":"773-781","update-policy":"https:\/\/doi.org\/10.14202\/vetworld.2022.policies","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical comparison of the non-locking bone plate, locking bone plate, and double-rod clamp internal fixation in a canine femoral model"],"prefix":"10.14202","author":[{"given":"Rutjathorn","family":"Maneewan","sequence":"first","affiliation":[{"name":"Kasetsart University Veterinary Teaching Hospital, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, 10900, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1386-5885","authenticated-orcid":false,"given":"Nattapon","family":"Chantarapanich","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering Sriracha, Kasetsart University, Sriracha Campus, Laem Chabang, 20230, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuma","family":"Morimoto","sequence":"additional","affiliation":[{"name":"Department of Aerospace Engineering, Kochi University of Technology, Kami, 782-8502, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3120-6111","authenticated-orcid":false,"given":"Chaiyakorn","family":"Thitiyanaporn","sequence":"additional","affiliation":[{"name":"Department of Companion Animal Clinical Sciences, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, 10900, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"5308","published-online":{"date-parts":[[2025,4,8]]},"reference":[{"key":"ref0","doi-asserted-by":"publisher","unstructured":"Aikawa, T., Fujita, Y., Yoshiki, K., Shibata, M., Hara, Y. and Takahashi, T. (2018) Clinical outcomes and complications after open reduction and internal fixation utilizing conventional plates in 65 distal radial and ulnar fractures of miniature- and toy-breed dogs. Vet. Comp. Orthop. Traumatol., 31(3): 214\u2013217.","DOI":"10.1055\/s-0038-1639485"},{"key":"ref1","unstructured":"Bidari, K., Kumar, V., Sharma, A., Patel, A. and Singh, R. (2023) Incidence of long bone fractures in dogs: A retrospective study (2016-2021). Pharma Innov. J., 12(6): 531\u2013534."},{"key":"ref2","unstructured":"Sompaisarnsilp, S., Temwichitr, J. and Thitiyanaporn, C. (2018) Causes and classification of long bone fractures in growing and adult dogs from orthopedic surgery unit: A retrospective study (2009-2018). J. Agric. Res. Extension, 35(2): 408\u2013415."},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"Beale, B. (2004) Orthopedic clinical techniques femur fracture repair. Clin. Tech. Small Anim. Pract., 19(3): 134\u2013150.","DOI":"10.1053\/j.ctsap.2004.09.006"},{"key":"ref4","doi-asserted-by":"publisher","unstructured":"Bernarde, A., Diop, A., Maurel, N. and Viguier, E. (2001) An in vitro biomechanical study of bone plate and interlocking nail in a canine diaphyseal femoral fracture model. Vet. Surg., 30(5): 397\u2013408.","DOI":"10.1053\/jvet.2001.25863"},{"key":"ref5","doi-asserted-by":"publisher","unstructured":"Stoffel, K., Dieter, U., Stachowiak, G., G\u00e4chter, A. and Kuster, M.S. (2003) Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? Injury, 34(Suppl 2): B11\u2013B19.","DOI":"10.1016\/j.injury.2003.09.021"},{"key":"ref6","doi-asserted-by":"publisher","unstructured":"Matres-Lorenzo, L., Diop, A., Maurel, N., Boucton, M., Bernard, F. and Bernad\u00e9, A. (2016) Biomechanical comparison of locking compression plate and limited contact dynamic compression plate combined with an intramedullary rod in a canine femoral fracture-gap model. Vet. Surg., 45(3): 319\u2013326.","DOI":"10.1111\/vsu.12451"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"Goh, C.S., Santoni, B.G., Puttlitz, C.M. and Palmer, R.H. (2009) Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora. Am. J. Vet. Res., 70(1): 23\u201329.","DOI":"10.2460\/ajvr.70.1.23"},{"key":"ref8","doi-asserted-by":"publisher","unstructured":"Provaggi, E., Capelli C., Rahmani, B., Burriesci, G. and Kalaskar, D.M. (2019) 3D printing assisted finite element analysis for optimising the manufacturing parameters of a lumbar fusion cage. Mater. Des., 163: 107540.","DOI":"10.1016\/j.matdes.2018.107540"},{"key":"ref9","doi-asserted-by":"publisher","unstructured":"Laurent, C.P., B\u00f6hme, B., Verwaerde, J., Papeleux, L., Ponthot, J. and Balligand, M. (2020) Effect of orthopedic implants on canine long bone compression stiffness: A combined experimental and computational approach. Proc. Inst. Mech. Eng. H., 234(3): 255\u2013264.","DOI":"10.1177\/0954411919882603"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"Nikkhoo, M., Hassani, K., Golpaygani A.T. and Karimi, A. (2020) Biomechanical role of posterior cruciate ligament in total knee arthroplasty: A finite element analysis. Comput. Methods Programs Biomed., 183: 105109.","DOI":"10.1016\/j.cmpb.2019.105109"},{"key":"ref11","doi-asserted-by":"publisher","unstructured":"Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J., Pujol, S., Bauer, C., Jennings, D., Fennessy F., Sonka, M., Buatti, J., Alyward, S., Miller, J.V., Pieper, S. and Kikinis, R. (2012) 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn. Reson. Imaging, 30(9): 1323\u20131341.","DOI":"10.1016\/j.mri.2012.05.001"},{"key":"ref12","doi-asserted-by":"publisher","unstructured":"Field, E.J., Parsons, K., Etches, J.A., Hamilton, K. and Burton, N.J. (2016) Effect of monocortical and bicortical screw numbers on the properties of a locking plate-intramedullary rod configuration. An in vitro study on a canine femoral fracture gap model. Vet. Comp. Orthop. Traumatol., 29(6): 459\u2013465.","DOI":"10.3415\/vcot-16-03-0040"},{"key":"ref13","doi-asserted-by":"crossref","unstructured":"Bel, J.C. (2019) Pitfalls and limits of locking plates. Orthop. Traumatol. Surg. Res., 105(1s): S103\u2013S109.","DOI":"10.1016\/j.otsr.2018.04.031"},{"key":"ref14","doi-asserted-by":"publisher","unstructured":"T\u00f6rnkvist, H., Hearn,T.C. and Schatzker, J. (1996) The strength of plate fixation in relation to the number and spacing of bone screws. J. Orthop. Trauma, 10(3): 204\u2013208.","DOI":"10.1097\/00005131-199604000-00009"},{"key":"ref15","doi-asserted-by":"publisher","unstructured":"Zhou, K. and Yang, H. (2022) Effects of bone-plate material on the predicted stresses in the tibial shaft comminuted fractures: A finite element analysis. J. Invest. Surg., 35(1): 132\u2013140.","DOI":"10.1080\/08941939.2020.1836290"},{"key":"ref16","doi-asserted-by":"publisher","unstructured":"Moi, T.S.M., Minto, B.W., Macedo, A.P., Lucena, D.V.F., Malta, C.A.S. and Dias, L.G.G.G. (2022) Preliminary study on a novel dedicated plate for iliac fractures in dogs. PLoS One, 17(8): e0269313.","DOI":"10.1371\/journal.pone.0269313"},{"key":"ref17","doi-asserted-by":"publisher","unstructured":"Lopez-Campos, J., Segade, A., Casarejos, E., Fern\u00e1ndez, J.R., Vil\u00e1n, J.A. and Izquierdo, P. (2018) Finite element study of a threaded fastening: The case of surgical screws in bone. Symmetry, 10(8): 335.","DOI":"10.3390\/sym10080335"},{"key":"ref18","doi-asserted-by":"publisher","unstructured":"Pitjamit, S., Nakkiew, W., Thongkorn, K., Thanakulwattana, W. and Thunsiri, K. (2020) Finite element analysis of traditional and new fixation techniques of the 3D-printed composite interlocking nail in canine femoral shaft fractures. Appl. Sci., 10(10): 3424.","DOI":"10.3390\/app10103424"},{"key":"ref19","doi-asserted-by":"publisher","unstructured":"Shahar, R., Banks-Sills, L. and Eliasy, R. (2003) Stress and strain distribution in the intact canine femur: Finite element analysis. Med. Eng. Phys., 25(5): 387\u2013395.","DOI":"10.1016\/s1350-4533(03)00002-x"},{"key":"ref20","doi-asserted-by":"publisher","unstructured":"Zahn, K., Frei, R., Wunderle, D., Linke, B., Schwieger, K., Guerguiev, B., Pohler, O. and Matis, U. (2008) Mechanical properties of 18 different AO bone plates and the clamp-rod internal fixation system tested on a gap model construct. Vet. Comp. Orthop. Traumatol., 21(3): 185\u2013194.","DOI":"10.1055\/s-0037-1617359"},{"key":"ref21","doi-asserted-by":"publisher","unstructured":"Muroi, N., Ochi, H., Shimada, M., Asou, Y. and Hara, Y. (2021) Effects of long-term plate fixation with different fixation modes on the radial cortical bone in dogs. PLoS One, 16(2): e0247410.","DOI":"10.1371\/journal.pone.0247410"},{"key":"ref22","doi-asserted-by":"publisher","unstructured":"Kaczmarek, J., Bartkowiak, T., Schuenemann, R., Paczos, P., Gapinski, B., Bogisch, S. and Unger, M. (2020) Mechanical performance of a polyaxial locking plate and the influence of screw angulation in a fracture gap model. Vet. Comp. Orthop. Traumatol., 33(1): 36\u201344.","DOI":"10.1055\/s-0039-1698415"},{"key":"ref23","unstructured":"Brunnberg, L., Horst, C., Gagel, A., Weiler, A. and Raschke, M. (1998) Osteosynthesis with the no contact plate (NCP)-A new biological implant system. Kleintierpraxis, 43: 579\u2013591."},{"key":"ref24","doi-asserted-by":"publisher","unstructured":"Beirami, S., Nikkhoo, M., Hassani, K. and Karimi, A. (2021) A comparative finite element simulation of locking compression plate materials for tibial fracture treatment. Comput. Methods Biomech. Biomed. Eng., 24(10): 1064\u20131072.","DOI":"10.1080\/10255842.2020.1867114"},{"key":"ref25","doi-asserted-by":"publisher","unstructured":"Chao, P., Conrad, B.P., Lewis, D.D., Horodyski, M. and Pozzi, A. (2013) Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate. BMC Vet. Res., 9: 125.","DOI":"10.1186\/1746-6148-9-125"},{"key":"ref26","doi-asserted-by":"publisher","unstructured":"Vallefuoco, R., Pommellet H.L., Savin, A., Decambron, A., Manassero, M., Viateau, V., Gauthier, O. and Fayolle, P. (2016) Complications of appendicular fracture repair in cats and small dogs using locking compression plates. Vet. Comp. Orthop. Traumatol., 29(1): 46\u201352.","DOI":"10.3415\/vcot-14-09-0146"},{"key":"ref27","doi-asserted-by":"publisher","unstructured":"Schorler, H., Capanni, F., Gaashan, M., Wendlandt, R., J\u00fcrgens, C. and Schulz, A.P. (2017) Bone plates for osteosynthesis-a systematic review of test methods and parameters for biomechanical testing. Biomed. Eng.-Biomed. Tech., 62(3): 235\u2013243.","DOI":"10.1515\/bmt-2015-0219"},{"key":"ref28","doi-asserted-by":"publisher","unstructured":"Wang, J., Zhang, X., Li, S., Yin, B., Liu, G., Cheng, X. and Zhang, Y. (2020) Plating System design determines mechanical environment in long bone mid-shaft fractures: A finite element analysis. J. Invest. Surg., 33(8): 699\u2013708.","DOI":"10.1080\/08941939.2019.1567875"},{"key":"ref29","doi-asserted-by":"publisher","unstructured":"\u015een, \u0130. and Sa\u011flam, M. (2021) Treatment outcomes of using paraosseous clamp and cerclage stabilisation technique in long bone fractures of cats: A retrospective study. Ankara Univ. Vet. Fak. Derg., 68: 47\u201352.","DOI":"10.33988\/auvfd.695818"},{"key":"ref30","doi-asserted-by":"publisher","unstructured":"Miller, A. (2024) Mechanical testing of sliding on pivot-locking clamp (SOP-LC) fracture repair system in four-point bending and torsion. Vet. Comp. Orthop. Traumatol., 37(4): 163\u2013172.","DOI":"10.1055\/s-0043-1778682"},{"key":"ref31","doi-asserted-by":"publisher","unstructured":"Zahn, K. and Matis, U. (2004) The clamp rod internal fixator - application and results in 120 small animal fracture patients. Vet. Comp. Orthop. Traumatol., 17: 110\u2013120.","DOI":"10.1055\/s-0038-1632808"},{"key":"ref32","doi-asserted-by":"publisher","unstructured":"Demner, D., Garcia, T.C., Serdy, M.G., Hayashi, K., Nir, B.A. and Stover, S.M. (2014) Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture. Vet. Comp. Orthop. Traumatol., 27(6): 422\u2013429.","DOI":"10.3415\/vcot-14-03-0040"},{"key":"ref33","unstructured":"Aumarm, W., Maneepong, G., Khothawornwong, N., Traywarunyoo, P. and Chareonlap, W. (2012) Comparative study of paracortical fixation, intramedullary pin and bone plate fixaiton for treating the femoral fracture in dogs. J. Thai Vet. Pract., 24: 15\u201322."}],"container-title":["Veterinary World"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/veterinaryworld.org\/Vol.18\/April-2025\/3.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T10:23:15Z","timestamp":1744107795000},"score":1,"resource":{"primary":{"URL":"https:\/\/veterinaryworld.org\/Vol.18\/April-2025\/3.php"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":34,"URL":"https:\/\/doi.org\/10.14202\/vetworld.2025.773-781","relation":{},"ISSN":["2231-0916","0972-8988"],"issn-type":[{"value":"2231-0916","type":"electronic"},{"value":"0972-8988","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-12-4","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-3-3","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-4-7","order":2,"name":"published_online","label":"Published Online","group":{"name":"publication_history","label":"Publication History"}}]}}