{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T20:04:47Z","timestamp":1780085087377,"version":"3.54.0"},"reference-count":7,"publisher":"Texas Heart Institute Journal","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,12]]},"abstract":"<jats:p>Transcatheter device implantation has become an attractive alternative to surgery in the closure of atrial septal defects in selected patients. However, it can lead to early and late sequelae, some of them life threatening. For example, 79 days before her admission to our emergency department with sudden-onset respiratory distress and respiratory arrest (leading to cardiac tamponade and rupture), a 22-year-old woman had undergone percutaneous closure of an atrial septal defect. We describe the damage and its treatment.<\/jats:p>\n        <jats:p>Although the adverse effects of transcatheter device implantation are rare, physicians should know that these events can be life threatening. Further data are needed to prevent such sequelae and to design new devices. It is of utmost importance that patients and their family members be informed both of possible sequelae and of life-saving interventions to be administered at early diagnosis.<\/jats:p>","DOI":"10.14503\/thij-15-5635","type":"journal-article","created":{"date-parts":[[2016,12,16]],"date-time":"2016-12-16T23:13:42Z","timestamp":1481930022000},"page":"541-542","source":"Crossref","is-referenced-by-count":4,"title":["Late Cardiac Rupture after Amplatzer Septal Occluder Implantation"],"prefix":"10.14503","volume":"43","author":[{"given":"Ahmet","family":"Arnaz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasemin","family":"Turkekul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuf","family":"Yalcinbas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arda","family":"Saygili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tayyar","family":"Sarioglu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"5628","reference":[{"issue":"3","key":"i1526-6702-43-6-541-b1","series-title":"Tex Heart Inst J","first-page":"220","article-title":"Closure of atrial septal defects in children: surgery versus Amplatzer device implantation","volume":"31","year":"2004","unstructured":"Bialkowski\n              J\n            , KarwotB, SzkutnikM, BanaszakP, KusaJ, SkalskiJ.\n          Closure of atrial septal defects in children: surgery versus Amplatzer device implantation. Tex Heart Inst J2004;31(3):220\u20133."},{"issue":"4","key":"i1526-6702-43-6-541-b2","series-title":"Ann Thorac Surg","first-page":"1435","article-title":"Late cardiac perforation following transcatheter atrial septal defect closure","volume":"77","year":"2004","unstructured":"Preventza\n              O\n            , Sampath-KumarS, WasnickJ, GoldJP.\n          Late cardiac perforation following transcatheter atrial septal defect closure. Ann Thorac Surg2004;77(4):1435\u20137."},{"issue":"4","key":"i1526-6702-43-6-541-b3","series-title":"Catheter Cardiovasc Interv","first-page":"496","article-title":"Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk","volume":"63","year":"2004","unstructured":"Amin\n              Z\n            , HijaziZM, BassJL, CheathamJP, HellenbrandWE, KleinmanCS.\n          Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv2004;63(4):496\u2013502."},{"issue":"8","key":"i1526-6702-43-6-541-b4","series-title":"J Am Coll Cardiol","first-page":"1213","article-title":"Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder","volume":"45","year":"2005","unstructured":"Divekar\n              A\n            , GaamangweT, ShaikhN, RaabeM, DucasJ.\n          Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol2005;45(8):1213\u20138."},{"issue":"6","key":"i1526-6702-43-6-541-b5","series-title":"Eur J Cardiothorac Surg","first-page":"1285","article-title":"Surgery for complications of trans-catheter closure of atrial septal defects: a multi-institutional study from the European Congenital Heart Surgeons Association","volume":"37","year":"2010","unstructured":"Sarris\n              GE\n            , KirvassilisG, ZavaropoulosP, BelliE, BerggrenH, CarrelT, \n          et al. Surgery for complications of trans-catheter closure of atrial septal defects: a multi-institutional study from the European Congenital Heart Surgeons Association. Eur J Cardiothorac Surg2010;37(6):1285\u201390."},{"issue":"5","key":"i1526-6702-43-6-541-b6","series-title":"JACC Cardiovasc Interv","first-page":"433","article-title":"Transcatheter device closure of atrial septal defects: a safety review","volume":"6","year":"2013","unstructured":"Moore\n              J\n            , HegdeS, El-SaidH, BeekmanR3rd, BensonL, BergersenL, \n          et al. Transcatheter device closure of atrial septal defects: a safety review. JACC Cardiovasc Interv2013;6(5):433\u201342."},{"key":"i1526-6702-43-6-541-b7","article-title":"Rare serious erosion events associated with St. Jude Amplatzer Atrial Septal Occluder (ASO): FDA Safety Communication [Internet]","year":"2013","unstructured":"Rare serious erosion events associated with St. Jude Amplatzer Atrial Septal Occluder (ASO): FDA Safety Communication [Internet]. 2013. Available from: http:\/\/www.fda.gov\/medicaldevices\/safety\/alertsandnotices\/ucm371145.htm [2013 Oct 17; revised 2014 Oct 10]."}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/43\/6\/article-p541.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/thij\/article-pdf\/43\/6\/541\/1879078\/thij-15-5635.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/43\/6\/article-p541.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/43\/6\/article-p541.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:33:01Z","timestamp":1730993581000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/43\/6\/article-p541.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":7,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.14503\/thij-15-5635","relation":{},"ISSN":["0730-2347","1526-6702"],"issn-type":[{"value":"0730-2347","type":"print"},{"value":"1526-6702","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12]]}}}