{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T12:31:29Z","timestamp":1765888289170,"version":"3.28.0"},"reference-count":22,"publisher":"Texas Heart Institute Journal","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:p>We evaluated whether an irrigated contact force\u2013sensing catheter would improve the safety and effectiveness of radiofrequency ablation of premature ventricular contractions originating from the right ventricular outflow tract.<\/jats:p>\n        <jats:p>We retrospectively reviewed the charts of patients with symptomatic premature ventricular contractions who underwent ablation with a contact force\u2013sensing catheter (56 patients, S<jats:sc>mart<\/jats:sc>T<jats:sc>ouch<\/jats:sc>) or conventional catheter (59 patients, T<jats:sc>hermo<\/jats:sc>C<jats:sc>ool<\/jats:sc>) at our hospital from August 2013 through December 2015. During a mean follow-up of 16 \u00b1 5 months, 3 patients in the conventional group had recurrences, compared with none in the contact force group. Complications occurred only in the conventional group (one steam pop; 2 ablations suspended because of significantly increasing impedance). In the contact force group, the median contact force during ablation was 10 g (interquartile range, 7\u201314 g). Times for overall procedure (36.9 \u00b1 5 min), fluoroscopy (86.3 \u00b1 22.7 s), and ablation (60.3 \u00b1 21.4 s) were significantly shorter in the contact force group than in the conventional group (46.2 \u00b1 6.2 min, 107.7 \u00b1 30 s, and 88.7 \u00b1 32.3 s, respectively; <jats:italic>P<\/jats:italic> &lt;0.001). In the contact force group, cases with a force-time integral &lt;560 gram-seconds (g-s) had significantly longer procedure and fluoroscopy times (both <jats:italic>P<\/jats:italic> &lt;0.001) than did those with a force-time integral \u2265560 g-s.<\/jats:p>\n        <jats:p>These findings suggest that ablation of premature ventricular contractions originating from the right ventricular outflow tract with an irrigated contact force\u2013sensing catheter instead of a conventional catheter shortens overall procedure, fluoroscopy, and ablation times without increasing risk of recurrence or complications.<\/jats:p>","DOI":"10.14503\/thij-17-6441","type":"journal-article","created":{"date-parts":[[2020,2,21]],"date-time":"2020-02-21T19:49:05Z","timestamp":1582314545000},"page":"3-9","source":"Crossref","is-referenced-by-count":8,"title":["Benefit of Contact Force\u2013Guided Catheter Ablation for Treating Premature Ventricular Contractions"],"prefix":"10.14503","volume":"47","author":[{"given":"Ziming","family":"Zhao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaowei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lianjun","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yutao","family":"Xi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xianjie","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanzong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunlong","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaomeng","family":"Yin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"6","key":"i1526-6702-47-1-3-b1","series-title":"J Cardiovasc Electrophysiol","first-page":"509","article-title":"Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact pressure and duration of energy delivery","volume":"2","year":"1991","unstructured":"Haines\n              DE.\n            \n          \n          Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol1991;2(6):509\u201315."},{"issue":"5","key":"i1526-6702-47-1-3-b2","series-title":"Circ Arrhythm Electrophysiol","article-title":"Recent advances in lesion formation for catheter ablation of atrial fibrillation","volume":"9","year":"2016","unstructured":"Barnett\n              AS\n            , BahnsonTD, PicciniJP.\n          Recent advances in lesion formation for catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol2016;9(5):e003299."},{"issue":"5","key":"i1526-6702-47-1-3-b3","series-title":"Circ Arrhythm Electrophysiol","first-page":"354","article-title":"Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus","volume":"1","year":"2008","unstructured":"Yokoyama\n              K\n            , NakagawaH, ShahDC, LambertH, LeoG, AebyN, \n          et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol2008;1(5):354\u201362."},{"issue":"9","key":"i1526-6702-47-1-3-b4","series-title":"J Cardiovasc Electrophysiol","first-page":"1038","article-title":"Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model","volume":"21","year":"2010","unstructured":"Shah\n              DC\n            , LambertH, NakagawaH, LangenkampA, AebyN, LeoG.\n          Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol2010;21(9):1038\u201343."},{"issue":"7","key":"i1526-6702-47-1-3-b5","series-title":"J Cardiovasc Electrophysiol","first-page":"806","article-title":"Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter","volume":"21","year":"2010","unstructured":"Thiagalingam\n              A\n            , D'AvilaA, FoleyL, GuerreroJL, LambertH, LeoG, \n          et al. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol2010;21(7):806\u201311."},{"issue":"10","key":"i1526-6702-47-1-3-b6","series-title":"Heart Rhythm","first-page":"1411","article-title":"Steam pops during irrigated radiofrequency ablation: feasibility of impedance monitoring for prevention","volume":"5","year":"2008","unstructured":"Seiler\n              J\n            , Roberts-ThomsonKC, RaymondJM, VestJ, DelacretazE, StevensonWG.\n          Steam pops during irrigated radiofrequency ablation: feasibility of impedance monitoring for prevention. Heart Rhythm2008;5(10):1411\u20136."},{"issue":"2","key":"i1526-6702-47-1-3-b7","series-title":"Heart Rhythm","first-page":"194","article-title":"Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters","volume":"11","year":"2014","unstructured":"Reichlin\n              T\n            , KnechtS, LaneC, KuhneM, NofE, ChopraN, \n          et al. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters. Heart Rhythm2014;11(2):194\u2013201."},{"issue":"1","key":"i1526-6702-47-1-3-b8","series-title":"Heart Rhythm","first-page":"18","article-title":"A novel radiofrequency ablation catheter using contact force sensing: Toccata study","volume":"9","year":"2012","unstructured":"Kuck\n              KH\n            , ReddyVY, SchmidtB, NataleA, NeuzilP, SaoudiN, \n          et al. A novel radiofrequency ablation catheter using contact force sensing: Toccata study. Heart Rhythm2012;9(1):18\u201323."},{"issue":"6","key":"i1526-6702-47-1-3-b9","series-title":"Circ Arrhythm Electrophysiol","first-page":"1342","article-title":"Contact force in atrial fibrillation: role of atrial rhythm and ventricular contractions: Co-Force Atrial Fibrillation Study","volume":"8","year":"2015","unstructured":"Sarkozy\n              A\n            , ShahD, SaenenJ, SieiraJ, PhlipsT, BorisW, \n          et al. Contact force in atrial fibrillation: role of atrial rhythm and ventricular contractions: Co-Force Atrial Fibrillation Study. Circ Arrhythm Electrophysiol2015;8(6):1342\u201350."},{"issue":"9","key":"i1526-6702-47-1-3-b10","series-title":"J Cardiovasc Electrophysiol","first-page":"994","article-title":"Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: a systematic review and meta-analysis","volume":"28","year":"2017","unstructured":"Lin\n              H\n            , ChenYH, HouJW, LuZY, XiangY, LiYG.\n          Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: a systematic review and meta-analysis. J Cardiovasc Electrophysiol2017;28(9):994\u20131005."},{"issue":"10","key":"i1526-6702-47-1-3-b11","series-title":"Neth Heart J","first-page":"460","article-title":"Catheter ablation of right ventricular outflow tract tachycardia using contact force guidance","volume":"22","year":"2014","unstructured":"Valk\n              SD\n            , de GrootNM, JordaensL.\n          Catheter ablation of right ventricular outflow tract tachycardia using contact force guidance. Neth Heart J2014;22(10):460\u20132."},{"key":"i1526-6702-47-1-3-b12","series-title":"Int J Cardiol","first-page":"441","article-title":"A prospective study on safety of catheter ablation procedures: contact force guided ablation could reduce the risk of cardiac perforation","volume":"179","year":"2015","unstructured":"Akca\n              F\n            , JanseP, TheunsDA, Szili-TorokT.\n          A prospective study on safety of catheter ablation procedures: contact force guided ablation could reduce the risk of cardiac perforation. Int J Cardiol2015;179:441\u20138."},{"issue":"6","key":"i1526-6702-47-1-3-b13","series-title":"Expert Rev Cardiovasc Ther","first-page":"749","article-title":"Contact force sensing during atrial fibrillation ablation: clinical experience and effects on outcomes","volume":"14","year":"2016","unstructured":"Liang\n              JJ\n            , SantangeliP.\n          Contact force sensing during atrial fibrillation ablation: clinical experience and effects on outcomes. Expert Rev Cardiovasc Ther2016;14(6):749\u201359."},{"issue":"Suppl 1","key":"i1526-6702-47-1-3-b14","series-title":"J Cardiovasc Electrophysiol","first-page":"S5","article-title":"A comparison of remote magnetic irrigated tip ablation versus manual catheter irrigated tip catheter ablation with and without force sensing feedback","volume":"27","year":"2016","unstructured":"Weiss\n              JP\n            , MayHT, BairTL, CrandallBG, CutlerMJ, DayJD, \n          et al. A comparison of remote magnetic irrigated tip ablation versus manual catheter irrigated tip catheter ablation with and without force sensing feedback. J Cardiovasc Electrophysiol2016;27Suppl 1:S5\u2013S10."},{"issue":"7","key":"i1526-6702-47-1-3-b15","series-title":"J Cardiovasc Electrophysiol","first-page":"762","article-title":"Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: a multicenter registry","volume":"28","year":"2017","unstructured":"Stabile\n              G\n            , Di DonnaP, SchillaciV, Di MonacoA, IulianoA, CaponiD, \n          et al. Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: a multicenter registry. J Cardiovasc Electrophysiol2017;28(7):762\u20137."},{"issue":"11","key":"i1526-6702-47-1-3-b16","series-title":"Heart Rhythm","first-page":"1789","article-title":"The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study","volume":"9","year":"2012","unstructured":"Reddy\n              VY\n            , ShahD, KautznerJ, SchmidtB, SaoudiN, HerreraC, \n          et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm2012;9(11):1789\u201395."},{"issue":"1","key":"i1526-6702-47-1-3-b17","series-title":"J Interv Card Electrophysiol","first-page":"9","article-title":"Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm","volume":"8","year":"2003","unstructured":"Sanchez\n              JE\n            , KayGN, BenserME, HallJA, WalcottGP, SmithWM, IdekerRE.\n          Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm. J Interv Card Electrophysiol2003;8(1):9\u201317."},{"issue":"12","key":"i1526-6702-47-1-3-b18","series-title":"Pacing Clin Electrophysiol","first-page":"1282","article-title":"Different patterns of the fall of impedance as the result of heating during ostial pulmonary vein ablation: implications for power titration","volume":"28","year":"2005","unstructured":"Reithmann\n              C\n            , RempT, HoffmannE, MatisT, WakiliR, SteinbeckG.\n          Different patterns of the fall of impedance as the result of heating during ostial pulmonary vein ablation: implications for power titration. Pacing Clin Electrophysiol2005;28(12):1282\u201391."},{"issue":"9","key":"i1526-6702-47-1-3-b19","series-title":"Heart Rhythm","first-page":"1291","article-title":"Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface","volume":"7","year":"2010","unstructured":"Otomo\n              K\n            , UnoK, FujiwaraH, IsobeM, IesakaY.\n          Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface. Heart Rhythm2010;7(9):1291\u2013300."},{"issue":"1","key":"i1526-6702-47-1-3-b20","series-title":"Circ Arrhythm Electrophysiol","first-page":"63","article-title":"Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis","volume":"7","year":"2014","unstructured":"Ullah\n              W\n            , HunterRJ, BakerV, DhinojaMB, SportonS, EarleyMJ, SchillingRJ.\n          Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis. Circ Arrhythm Electrophysiol2014;7(1):63\u20138."},{"issue":"4","key":"i1526-6702-47-1-3-b21","series-title":"Circ Arrhythm Electrophysiol","article-title":"Novel measure of local impedance predicts catheter-tissue contact and lesion formation","volume":"11","year":"2018","unstructured":"Sulkin\n              MS\n            , LaughnerJI, HilbertS, KapaS, KosiukJ, YounanP, \n          et al. Novel measure of local impedance predicts catheter-tissue contact and lesion formation. Circ Arrhythm Electrophysiol2018;11(4):e005831."},{"issue":"2","key":"i1526-6702-47-1-3-b22","series-title":"Clin Res Cardiol","first-page":"97","article-title":"Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation","volume":"103","year":"2014","unstructured":"Wakili\n              R\n            , ClaussS, SchmidtV, UlbrichM, HahnefeldA, SchusslerF, \n          et al. Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation. Clin Res Cardiol2014;103(2):97\u2013106."}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/47\/1\/article-p3.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/thij\/article-pdf\/47\/1\/3\/2445474\/thij-17-6441.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/47\/1\/article-p3.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/47\/1\/article-p3.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:35:58Z","timestamp":1730993758000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/47\/1\/article-p3.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":22,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.14503\/thij-17-6441","relation":{},"ISSN":["0730-2347","1526-6702"],"issn-type":[{"type":"print","value":"0730-2347"},{"type":"electronic","value":"1526-6702"}],"subject":[],"published":{"date-parts":[[2020,2]]}}}