{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T05:24:21Z","timestamp":1731043461816,"version":"3.28.0"},"reference-count":10,"publisher":"Texas Heart Institute Journal","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:p>Determining the optimal length of artificial chordae tendineae and then effectively securing them is a major challenge in mitral valve repair. Our technique for measuring and stabilizing neochordae involves tying a polypropylene suture loop onto the annuloplasty ring. We used this method in 4 patients who had moderate-to-severe mitral regurgitation from degenerative posterior leaflet (P2) prolapse and flail chordae. Results of intraoperative saline tests and postoperative transesophageal echocardiography revealed only mild insufficiency. One month postoperatively, echocardiograms showed trivial regurgitation in all 4 patients. We think that this simple, precise method for adjusting and stabilizing artificial chordae will be advantageous in mitral valve repair.<\/jats:p>","DOI":"10.14503\/thij-18-6913","type":"journal-article","created":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T23:57:52Z","timestamp":1601510272000},"page":"207-209","source":"Crossref","is-referenced-by-count":0,"title":["Optimizing P2 Neochordal Length and Stability in Mitral Valve Repair With Use of a Polypropylene Loop"],"prefix":"10.14503","volume":"47","author":[{"given":"Anil","family":"Ozen","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Training and Research Hospital, 06230 Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ertekin Utku","family":"Unal","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Training and Research Hospital, 06230 Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hamdi Mehmet","family":"Ozbek","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Training and Research Hospital, 06230 Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gorkem","family":"Yigit","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Training and Research Hospital, 06230 Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hakki Zafer","family":"Iscan","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Turkiye Yuksek Ihtisas Training and Research Hospital, 06230 Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"23","key":"i1526-6702-47-3-207-b1","series-title":"Circulation","first-page":"e521","article-title":"2014 AHA\/ACC Guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines [published errata appear in Circulation 2014;129(23):e651 and Circulation 2014;130(13):e120]","volume":"129","year":"2014","unstructured":"Nishimura\n              RA,\n            \n            \n              Otto\n              CM,\n            \n            \n              Bonow\n              RO,\n            \n            \n              Carabello\n              BA,\n            \n            \n              Erwin\n              JP\n              3rd\n            ,\n\t\t\t\t\t\tGuytonRA,\n          et al.\n          2014 AHA\/ACC Guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines [published errata appear in Circulation 2014;129(23):e651 and Circulation 2014;130(13):e120].\n\t\t\t\t\tCirculation2014;129(23):e521\u2013e643."},{"key":"i1526-6702-47-3-207-b2","series-title":"Comput Cardiol","first-page":"273","article-title":"Adjustment of artificial chordae to the mitral valve with advanced tactile technique","volume":"35","year":"2008","unstructured":"Braun\n              EU,\n            \n            \n              Voss\n              B,\n            \n            \n              Mayer\n              H,\n            \n            \n              Knoll\n              A,\n            \n            \n              Bauernschmitt\n              R,\n            \n            \n              Lange\n              R.\n            \n          \n          Adjustment of artificial chordae to the mitral valve with advanced tactile technique.\n\t\t\t\t\tComput Cardiol2008;35:273\u20134."},{"issue":"3","key":"i1526-6702-47-3-207-b3","series-title":"J Card Surg","first-page":"204","article-title":"A simple method to obtain the correct length of the artificial chordae in complex chordal replacement","volume":"23","year":"2008","unstructured":"Calafiore\n              AM,\n            \n            \n              Scandura\n              S,\n            \n            \n              Iaco\n              AL,\n            \n            \n              Contini\n              M,\n            \n            \n              Di Mauro\n              M,\n            \n            \n              Bivona\n              A,\n            \n          \n          et al.\n          A simple method to obtain the correct length of the artificial chordae in complex chordal replacement.\n\t\t\t\t\tJ Card Surg2008;23(3):204\u20136."},{"issue":"6","key":"i1526-6702-47-3-207-b4","series-title":"Ann Thorac Surg","first-page":"2127","article-title":"Pre-measured artificial chordae for mitral valve repair","volume":"84","year":"2007","unstructured":"Gillinov\n              AM,\n            \n            \n              Banbury\n              MK.\n            \n          \n          Pre-measured artificial chordae for mitral valve repair.\n\t\t\t\t\tAnn Thorac Surg2007;84(6):2127\u20139."},{"issue":"5","key":"i1526-6702-47-3-207-b5","series-title":"Ann Thorac Surg","first-page":"1902","article-title":"Simple, safe and easy technique to ensure the correct length of artificial chordae in mitral valve repair","volume":"83","year":"2007","unstructured":"Fattouch\n              K,\n            \n            \n              Bianco\n              G,\n            \n            \n              Sbraga\n              F,\n            \n            \n              Sampognaro\n              R,\n            \n            \n              Ruvolo\n              G.\n            \n          \n          Simple, safe and easy technique to ensure the correct length of artificial chordae in mitral valve repair.\n\t\t\t\t\tAnn Thorac Surg2007;83(5):1902\u20133."},{"issue":"3","key":"i1526-6702-47-3-207-b6","series-title":"Ann Thorac Surg","first-page":"1064","article-title":"A new device for ensuring the correct length of artificial chordae in mitral valvuloplasty","volume":"79","year":"2005","unstructured":"Matsui\n              Y,\n            \n            \n              Fukada\n              Y,\n            \n            \n              Naito\n              Y,\n            \n            \n              Sasaki\n              S,\n            \n            \n              Yasuda\n              K.\n            \n          \n          A new device for ensuring the correct length of artificial chordae in mitral valvuloplasty.\n\t\t\t\t\tAnn Thorac Surg2005;79(3):1064\u20135."},{"issue":"1","key":"i1526-6702-47-3-207-b7","series-title":"Ann Thorac Surg","first-page":"237","article-title":"Simple method for determining proper length of artificial chordae in mitral valve repair","volume":"57","year":"1994","unstructured":"Kasegawa\n              H,\n            \n            \n              Kamata\n              S,\n            \n            \n              Hirata\n              S,\n            \n            \n              Kobayashi\n              N,\n            \n            \n              Mannouji\n              E,\n            \n            \n              Ida\n              T,\n            \n            \n              Kawase\n              M.\n            \n          \n          Simple method for determining proper length of artificial chordae in mitral valve repair.\n\t\t\t\t\tAnn Thorac Surg1994;57(1):237\u20139."},{"issue":"6","key":"i1526-6702-47-3-207-b8","series-title":"Ann Thorac Surg","first-page":"2166","article-title":"Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops","volume":"70","year":"2000","unstructured":"von Oppell\n              UO,\n            \n            \n              Mohr\n              FW.\n            \n          \n          Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops.\n\t\t\t\t\tAnn Thorac Surg2000;70(6):2166\u20138."},{"issue":"3","key":"i1526-6702-47-3-207-b9","series-title":"Ann Thorac Surg","first-page":"1132","article-title":"Measured tube technique for ensuring the correct length of slippery artificial chordae in mitral valvuloplasty","volume":"92","year":"2011","unstructured":"Matsui\n              Y,\n            \n            \n              Kubota\n              S,\n            \n            \n              Sugiki\n              H,\n            \n            \n              Wakasa\n              S,\n            \n            \n              Ooka\n              T,\n            \n            \n              Tachibana\n              T,\n            \n            \n              Sasaki\n              S.\n            \n          \n          Measured tube technique for ensuring the correct length of slippery artificial chordae in mitral valvuloplasty.\n\t\t\t\t\tAnn Thorac Surg2011;92(3):1132\u20134."},{"issue":"4","key":"i1526-6702-47-3-207-b10","series-title":"Ann Thorac Surg","first-page":"e183","article-title":"How to adjust neochordae length accurately in degenerative mitral regurgitation","volume":"105","year":"2018","unstructured":"Rodriguez-Roda\n              J,\n            \n            \n              Miguelena\n              J,\n            \n            \n              Lopez\n              J,\n            \n            \n              Martin\n              M,\n            \n            \n              Munoz\n              R.\n            \n          \n          How to adjust neochordae length accurately in degenerative mitral regurgitation.\n\t\t\t\t\tAnn Thorac Surg2018;105(4):e183\u20134."}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/47\/3\/article-p207.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/thij\/article-pdf\/47\/3\/207\/2816312\/i1526-6702-47-3-207.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/47\/3\/article-p207.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/47\/3\/article-p207.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:34:12Z","timestamp":1730993652000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/47\/3\/article-p207.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":10,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.14503\/thij-18-6913","relation":{},"ISSN":["0730-2347"],"issn-type":[{"type":"print","value":"0730-2347"}],"subject":[],"published":{"date-parts":[[2020,6]]}}}