{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T05:24:23Z","timestamp":1731043463330,"version":"3.28.0"},"reference-count":22,"publisher":"Texas Heart Institute Journal","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,9,1]]},"abstract":"<jats:p>The transcatheter aortic valve replacement procedure is used in patients with aortic stenosis. Transcatheter aortic valve replacement devices are quite versatile; thus, they are increasingly being used for nonaortic applications, such as tricuspid valve-in-valve implantation. This case series describes a transcatheter aortic valve replacement procedure in 4 patients with anatomic challenges (eg, aortic tortuosity, high valvular calcium burden, highly calcified bicuspid valve, low coronary artery takeoff, left main coronary artery occlusion, and large aortic annulus) and a fifth patient who had a failed tricuspid bioprosthesis and underwent a tricuspid valve-in-valve implantation with the Edwards SAPIEN 3 transcatheter heart valve (Edwards Lifesciences). All procedures required adjustments to the standard protocol, and each procedure was successful. The critical, technical adjustments in the deployment technique and preprocedural planning of the procedures are detailed to provide a road map for other cardiologists who encounter similar challenges.<\/jats:p>","DOI":"10.14503\/thij-21-7579","type":"journal-article","created":{"date-parts":[[2022,10,12]],"date-time":"2022-10-12T16:16:07Z","timestamp":1665591367000},"source":"Crossref","is-referenced-by-count":0,"title":["Use of the SAPIEN 3 Transcatheter Heart Valve in High-Risk Scenarios"],"prefix":"10.14503","volume":"49","author":[{"given":"Angelo","family":"Nascimbene","sequence":"first","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Courtney","family":"McAlister","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Yo","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stanislava","family":"Matejin","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mateja","family":"Jezovnik","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Igor D.","family":"Gregoric","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Biswajit","family":"Kar","sequence":"additional","affiliation":[{"name":"Department of Advanced Cardiopulmonary Therapies and Transplantation, Center for Advanced Heart Failure, University of Texas Health Science Center at Houston, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"4","key":"i1526-6702-49-5-e217579-b1","series-title":"J Cardiovasc Comput Tomogr.","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.jcct.2017.04.009","article-title":"Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: elucidating optimal threshold cutoffs","volume":"11","year":"2017","unstructured":"Bettinger\n              N,\n            \n            \n              Khalique\n              OK,\n            \n            \n              Krepp\n              JM,\n            \n          \n          .\n\t\t\t\t\tPractical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: elucidating optimal threshold cutoffs.\n\t\t\t\t\tJ Cardiovasc Comput Tomogr.2017;11(4):302\u2013308.\n\t\t\t\t\tdoi:10.1016\/j.jcct.2017.04.009"},{"issue":"13","key":"i1526-6702-49-5-e217579-b2","series-title":"J Am Coll Cardiol.","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1016\/j.jacc.2012.01.001","article-title":"2012 ACCF\/AATS\/SCAI\/STS expert consensus document on transcatheter aortic valve replacement","volume":"59","year":"2012","unstructured":"Holmes\n              DR\n              Jr,\n            \n            \n              Mack\n              MJ,\n            \n            \n              Kaul\n              S,\n            \n          \n          .\n\t\t\t\t\t2012 ACCF\/AATS\/SCAI\/STS expert consensus document on transcatheter aortic valve replacement.\n\t\t\t\t\tJ Am Coll Cardiol.2012;59(13):1200\u20131254.\n\t\t\t\t\tdoi:10.1016\/j.jacc.2012.01.001"},{"issue":"6","key":"i1526-6702-49-5-e217579-b3","series-title":"EuroIntervention.","doi-asserted-by":"publisher","first-page":"666","DOI":"10.4244\/eijv5i6a110","article-title":"Vascular complications of transfemoral aortic valve implantation with the Edwards SAPIEN prosthesis: incidence and impact on outcome","volume":"5","year":"2010","unstructured":"Ducrocq\n              G,\n            \n            \n              Francis\n              F,\n            \n            \n              Serfaty\n              JM,\n            \n          \n          .\n\t\t\t\t\tVascular complications of transfemoral aortic valve implantation with the Edwards SAPIEN prosthesis: incidence and impact on outcome.\n\t\t\t\t\tEuroIntervention.2010;5(6):666\u2013672.\n\t\t\t\t\tdoi:10.4244\/eijv5i6a110"},{"issue":"3","key":"i1526-6702-49-5-e217579-b4","series-title":"Int J Cardiol.","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.ijcard.2006.03.058","article-title":"Cardiac pacing in balloon aortic valvuloplasty","volume":"116","year":"2007","unstructured":"David\n              F,\n            \n            \n              Sanchez\n              A,\n            \n            \n              Yanez\n              L,\n            \n          \n          .\n\t\t\t\t\tCardiac pacing in balloon aortic valvuloplasty.\n\t\t\t\t\tInt J Cardiol.2007;116(3):327\u2013330.\n\t\t\t\t\tdoi:10.1016\/j.ijcard.2006.03.058"},{"issue":"4","key":"i1526-6702-49-5-e217579-b5","series-title":"Images Paediatr Cardiol.","first-page":"31","article-title":"How to achieve balloon stability in aortic valvuloplasty using rapid ventricular pacing","volume":"6","year":"2004","unstructured":"Mehta\n              C,\n            \n            \n              Shebani\n              S,\n            \n            \n              Grech\n              V,\n            \n            \n              Degiovanni\n              J.\n            \n          \n          How to achieve balloon stability in aortic valvuloplasty using rapid ventricular pacing.\n\t\t\t\t\tImages Paediatr Cardiol.2004;6(4):31\u201337."},{"issue":"5","key":"i1526-6702-49-5-e217579-b6","series-title":"Europace.","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1093\/europace\/euy316","article-title":"Risk factors for atrioventricular block after transcatheter aortic valve implantation: a single-centre analysis including assessment of aortic calcifications and follow-up","volume":"21","year":"2019","unstructured":"Pollari\n              F,\n            \n            \n              Grossmann\n              I,\n            \n            \n              Vogt\n              F,\n            \n          \n          .\n\t\t\t\t\tRisk factors for atrioventricular block after transcatheter aortic valve implantation: a single-centre analysis including assessment of aortic calcifications and follow-up.\n\t\t\t\t\tEuropace.2019;21(5):787\u2013795.\n\t\t\t\t\tdoi:10.1093\/europace\/euy316"},{"issue":"12","key":"i1526-6702-49-5-e217579-b7","series-title":"Eur Heart J Cardiovasc Imaging.","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1093\/ehjci\/jeu162","article-title":"A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation","volume":"15","year":"2014","unstructured":"Jilaihawi\n              H,\n            \n            \n              Makkar\n              RR,\n            \n            \n              Kashif\n              M,\n            \n          \n          .\n\t\t\t\t\tA revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.\n\t\t\t\t\tEur Heart J Cardiovasc Imaging.2014;15(12):1324\u20131332.\n\t\t\t\t\tdoi:10.1093\/ehjci\/jeu162"},{"issue":"6","key":"i1526-6702-49-5-e217579-b8","series-title":"Eur Heart J Cardiovasc Imaging.","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1093\/ehjci\/jex032","article-title":"Aortic root calcium burden and post-transcatheter aortic valve implantation paravalvular leak: can't live without it, can't live with it","volume":"18","year":"2017","unstructured":"Qian\n              Z,\n            \n            \n              Lancellotti\n              P,\n            \n            \n              Vannan\n              MA.\n            \n          \n          Aortic root calcium burden and post-transcatheter aortic valve implantation paravalvular leak: can't live without it, can't live with it.\n\t\t\t\t\tEur Heart J Cardiovasc Imaging.2017;18(6):654\u2013656.\n\t\t\t\t\tdoi:10.1093\/ehjci\/jex032"},{"issue":"8","key":"i1526-6702-49-5-e217579-b9","series-title":"JACC Cardiovasc Interv.","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1016\/j.jcin.2017.02.021","article-title":"Computed tomography-based oversizing degrees and incidence of paravalvular regurgitation of a new generation transcatheter heart valve","volume":"10","year":"2017","unstructured":"Blanke\n              P,\n            \n            \n              Pibarot\n              P,\n            \n            \n              Hahn\n              R,\n            \n          \n          .\n\t\t\t\t\tComputed tomography-based oversizing degrees and incidence of paravalvular regurgitation of a new generation transcatheter heart valve.\n\t\t\t\t\tJACC Cardiovasc Interv.2017;10(8):810\u2013820.\n\t\t\t\t\tdoi:10.1016\/j.jcin.2017.02.021"},{"issue":"3","key":"i1526-6702-49-5-e217579-b10","series-title":"Circulation.","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","article-title":"Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement","volume":"128","year":"2013","unstructured":"Barbanti\n              M,\n            \n            \n              Yang\n              TH,\n            \n            \n              Rodes Cabau\n              J,\n            \n            .\n\t\t\t\t\t\n          Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.\n\t\t\t\t\tCirculation.2013;128(3):244\u2013253.\n\t\t\t\t\tdoi:10.1161\/CIRCULATIONAHA.113.002947"},{"issue":"3","key":"i1526-6702-49-5-e217579-b11","series-title":"Heart Lung Circ.","doi-asserted-by":"publisher","first-page":"e11","DOI":"10.1016\/j.hlc.2017.08.025","article-title":"Transcatheter aortic valve implantation in patients with a large aortic annulus","volume":"27","year":"2018","unstructured":"Barr\n              P,\n            \n            \n              Ormiston\n              J,\n            \n            \n              Stewart\n              J,\n            \n            \n              Nand\n              P,\n            \n            \n              Ramanathan\n              T,\n            \n            \n              Webster\n              M.\n            \n          \n          Transcatheter aortic valve implantation in patients with a large aortic annulus.\n\t\t\t\t\tHeart Lung Circ.2018;27(3):e11\u2013e14.\n\t\t\t\t\tdoi:10.1016\/j.hlc.2017.08.025"},{"issue":"6","key":"i1526-6702-49-5-e217579-b12","series-title":"Catheter Cardiovasc Interv.","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1002\/ccd.27190","article-title":"Overexpansion of the 29 mm2 SAPIEN 3 transcatheter heart valve in patients with large aortic annuli (area > 683 mm2): a case series","volume":"91","year":"2018","unstructured":"Mathur\n              M,\n            \n            \n              McCabe\n              JM,\n            \n            \n              Aldea\n              G,\n            \n            \n              Pal\n              J,\n            \n            \n              Don\n              CW.\n            \n          \n          Overexpansion of the 29 mm2 SAPIEN 3 transcatheter heart valve in patients with large aortic annuli (area > 683 mm2): a case series.\n\t\t\t\t\tCatheter Cardiovasc Interv.2018;91(6):1149\u20131156.\n\t\t\t\t\tdoi:10.1002\/ccd.27190"},{"issue":"5","key":"i1526-6702-49-5-e217579-b13","series-title":"JACC Cardiovasc Interv.","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/j.jcin.2012.11.014","article-title":"Coronary obstruction following transcatheter aortic valve implantation: a systematic review","volume":"6","year":"2013","unstructured":"Ribeiro\n              HB,\n            \n            \n              Nombela-Franco\n              L,\n            \n            \n              Urena\n              M,\n            \n          \n          .\n\t\t\t\t\tCoronary obstruction following transcatheter aortic valve implantation: a systematic review.\n\t\t\t\t\tJACC Cardiovasc Interv.2013;6(5):452\u2013461.\n\t\t\t\t\tdoi:10.1016\/j.jcin.2012.11.014"},{"issue":"25","key":"i1526-6702-49-5-e217579-b14","series-title":"Circulation.","doi-asserted-by":"publisher","first-page":"e1159","DOI":"10.1161\/CIR.0000000000000503","article-title":"2017 AHA\/ACC focused update of the 2014 AHA\/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association task force on clinical practice guidelines","volume":"135","year":"2017","unstructured":"Nishimura\n              RA,\n            \n            \n              Otto\n              CM,\n            \n            \n              Bonow\n              RO,\n            \n          \n          .\n\t\t\t\t\t2017 AHA\/ACC focused update of the 2014 AHA\/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association task force on clinical practice guidelines.\n\t\t\t\t\tCirculation.2017;135(25):e1159\u2013e1195.\n\t\t\t\t\tdoi:10.1161\/CIR.0000000000000503"},{"issue":"3","key":"i1526-6702-49-5-e217579-b15","series-title":"Catheter Cardiovasc Interv.","first-page":"456","article-title":"Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter SAPIEN valve-in-valve placement","volume":"88","year":"2016","unstructured":"Brown\n              SC,\n            \n            \n              Cools\n              B,\n            \n            \n              Gewillig\n              M.\n            \n          \n          Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter SAPIEN valve-in-valve placement.\n\t\t\t\t\tCatheter Cardiovasc Interv.2016;88(3):456\u2013459."},{"issue":"7","key":"i1526-6702-49-5-e217579-b16","series-title":"Circ Cardiovasc Interv.","doi-asserted-by":"publisher","first-page":"e005216","DOI":"10.1161\/CIRCINTERVENTIONS.117.005216","article-title":"Bioprosthetic valve fracture improves the hemodynamic results of valve-in-valve transcatheter aortic valve replacement","volume":"10","year":"2017","unstructured":"Chhatriwalla\n              AK,\n            \n            \n              Allen\n              KB,\n            \n            \n              Saxon\n              JT,\n            \n          \n          .\n\t\t\t\t\tBioprosthetic valve fracture improves the hemodynamic results of valve-in-valve transcatheter aortic valve replacement.\n\t\t\t\t\tCirc Cardiovasc Interv.2017;10(7):e005216.\n\t\t\t\t\tdoi:10.1161\/CIRCINTERVENTIONS.117.005216"},{"issue":"16","key":"i1526-6702-49-5-e217579-b17","series-title":"Circulation.","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.1161\/CIRCULATIONAHA.115.019353","article-title":"Transcatheter tricuspid valve-in-valve implantation for the treatment of dysfunctional surgical bioprosthetic valves: an international, multicenter registry study","volume":"133","year":"2016","unstructured":"McElhinney\n              DB,\n            \n            \n              Cabalka\n              AK,\n            \n            \n              Aboulhosn\n              JA,\n            \n          \n          .\n\t\t\t\t\tTranscatheter tricuspid valve-in-valve implantation for the treatment of dysfunctional surgical bioprosthetic valves: an international, multicenter registry study.\n\t\t\t\t\tCirculation.2016;133(16):1582\u20131593.\n\t\t\t\t\tdoi:10.1161\/CIRCULATIONAHA.115.019353"},{"issue":"2","key":"i1526-6702-49-5-e217579-b18","series-title":"Am J Cardiol.","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.amjcard.2017.10.017","article-title":"Outcomes of transcatheter tricuspid valve-in-valve implantation in patients with Ebstein anomaly","volume":"121","year":"2018","unstructured":"Taggart\n              NW,\n            \n            \n              Cabalka\n              AK,\n            \n            \n              Eicken\n              A,\n            \n          \n          .\n\t\t\t\t\tOutcomes of transcatheter tricuspid valve-in-valve implantation in patients with Ebstein anomaly.\n\t\t\t\t\tAm J Cardiol.2018;121(2):262\u2013268.\n\t\t\t\t\tdoi:10.1016\/j.amjcard.2017.10.017"},{"issue":"1","key":"i1526-6702-49-5-e217579-b19","series-title":"J Cardiothorac Vasc Anesth.","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/1053-0770(91)90041-q","article-title":"Age and right ventricular function during cardiac surgery","volume":"6","year":"1992","unstructured":"Boldt\n              J,\n            \n            \n              Zickmann\n              B,\n            \n            \n              Thiel\n              A,\n            \n            \n              Dapper\n              F,\n            \n            \n              Hempelmann\n              G.\n            \n          \n          Age and right ventricular function during cardiac surgery.\n\t\t\t\t\tJ Cardiothorac Vasc Anesth.1992;6(1):29\u201332.\n\t\t\t\t\tdoi:10.1016\/1053-0770(91)90041-q"},{"issue":"5","key":"i1526-6702-49-5-e217579-b20","series-title":"Eur J Cardiothorac Surg.","doi-asserted-by":"publisher","first-page":"e127","DOI":"10.1093\/ejcts\/ezw048","article-title":"Surgical factors and complications affecting hospital outcome in redo mitral surgery: insights from a multicentre experience","volume":"49","year":"2016","unstructured":"Onorati\n              F,\n            \n            \n              Perrotti\n              A,\n            \n            \n              Reichart\n              D,\n            \n          \n          .\n\t\t\t\t\tSurgical factors and complications affecting hospital outcome in redo mitral surgery: insights from a multicentre experience.\n\t\t\t\t\tEur J Cardiothorac Surg.2016;49(5):e127\u2013e133.\n\t\t\t\t\tdoi:10.1093\/ejcts\/ezw048"},{"issue":"20","key":"i1526-6702-49-5-e217579-b21","series-title":"Circulation.","doi-asserted-by":"publisher","first-page":"2718","DOI":"10.1161\/CIRCULATIONAHA.108.842773","article-title":"The tricuspid valve: current perspective and evolving management of tricuspid regurgitation","volume":"119","year":"2009","unstructured":"Rogers\n              JH,\n            \n            \n              Bolling\n              SF.\n            \n          \n          The tricuspid valve: current perspective and evolving management of tricuspid regurgitation.\n\t\t\t\t\tCirculation.2009;119(20):2718\u20132725.\n\t\t\t\t\tdoi:10.1161\/CIRCULATIONAHA.108.842773"},{"issue":"21","key":"i1526-6702-49-5-e217579-b22","series-title":"JACC Cardiovasc Interv.","doi-asserted-by":"publisher","first-page":"2226","DOI":"10.1016\/j.jcin.2018.06.011","article-title":"Transcatheter tricuspid valve-in-valve replacement with subsequent bioprosthetic valve fracture to optimize hemodynamic function","volume":"11","year":"2018","unstructured":"Hensey\n              M,\n            \n            \n              Alenezi\n              AR,\n            \n            \n              Murdoch\n              DJ,\n            \n          \n          .\n\t\t\t\t\tTranscatheter tricuspid valve-in-valve replacement with subsequent bioprosthetic valve fracture to optimize hemodynamic function.\n\t\t\t\t\tJACC Cardiovasc Interv.2018;11(21):2226\u20132227.\n\t\t\t\t\tdoi:10.1016\/j.jcin.2018.06.011"}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/49\/5\/article-e217579.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/thij\/article-pdf\/doi\/10.14503\/THIJ-21-7579\/3415493\/i1526-6702-49-5-e217579.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/49\/5\/article-e217579.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/49\/5\/article-e217579.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:37:46Z","timestamp":1730993866000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/49\/5\/article-e217579.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,1]]},"references-count":22,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.14503\/thij-21-7579","relation":{},"ISSN":["1526-6702","0730-2347"],"issn-type":[{"type":"electronic","value":"1526-6702"},{"type":"print","value":"0730-2347"}],"subject":[],"published":{"date-parts":[[2022,9,1]]}}}