{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T05:24:20Z","timestamp":1731043460435,"version":"3.28.0"},"reference-count":9,"publisher":"Texas Heart Institute Journal","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>Although the management of traumatic injuries to the thoracic aorta has shifted toward endovascular management, the historical standard of care is open reconstruction. Choosing to reoperate when faced with a complication from a prior open repair can be challenging; endovascular management can be a reasonable option in this situation. This report describes a 54-year-old man with a remote history of open surgery for a traumatic injury to the descending thoracic aorta who underwent endovascular aortic stent graft placement for coverage of extrathoracic graft extension with pseudoaneurysm formation and distal embolization. He returned a year later with a type IIIb endoleak with rupture into the posterolateral chest wall. A sec ond endovascular approach was used to successfully reline the graft and exclude the rupture.<\/jats:p>","DOI":"10.14503\/thij-22-7850","type":"journal-article","created":{"date-parts":[[2023,4,3]],"date-time":"2023-04-03T19:25:35Z","timestamp":1680549935000},"source":"Crossref","is-referenced-by-count":0,"title":["Two Endovascular Stent Graft Repairs Needed for an Extrathoracic Aortic Graft: Distant Complications After an Original Open Repair for a Gunshot Wound to the Chest"],"prefix":"10.14503","volume":"50","author":[{"given":"Kate","family":"Kiely","sequence":"first","affiliation":[{"name":"Sanger Heart & Vascular Institute, Atrium Health Carolinas Medical Center, Charlotte, North Carolina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Arko","sequence":"additional","affiliation":[{"name":"Sanger Heart & Vascular Institute, Atrium Health Carolinas Medical Center, Charlotte, North Carolina"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"1","key":"i1526-6702-50-2-e227850-b1","series-title":"J Vasc Surg.","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jvs.2010.08.027","article-title":"Endovascular repair of traumatic thoracic aortic injury: clinical practice guidelines of the Society for Vascular Surgery","volume":"53","year":"2011","unstructured":"Lee\n              WA,\n            \n            \n              Matsumura\n              JS,\n            \n            \n              Mitchell\n              RS,\n            \n          \n          .\n\t\t\t\t\tEndovascular repair of traumatic thoracic aortic injury: clinical practice guidelines of the Society for Vascular Surgery.\n\t\t\t\t\tJ Vasc Surg.2011;53(1):187\u2013192.\n\t\t\t\t\tdoi:10.1016\/j.jvs.2010.08.027"},{"issue":"1","key":"i1526-6702-50-2-e227850-b2","series-title":"Eur J Cardiothorac Surg.","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1093\/ejcts\/ezs107","article-title":"Thoracic endovascular aortic repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)","volume":"42","year":"2012","unstructured":"Grabenw\u00f6ger\n              M,\n            \n            \n              Alfonso\n              F,\n            \n            \n              Bachet\n              J,\n            \n            ;\n\t\t\t\t\t\tEuropean Association for Cardio-Thoracic Surgery (EACTS), European Society of Cardiology (ESC), European Association of Percutaneous Cardiovascular Interventions (EAPCI).\n          Thoracic endovascular aortic repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI).\n\t\t\t\t\tEur J Cardiothorac Surg.2012;42(1):17\u201324.\n\t\t\t\t\tdoi:10.1093\/ejcts\/ezs107"},{"issue":"25","key":"i1526-6702-50-2-e227850-b3","series-title":"Circulation.","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1161\/CIR.0b013e3181e4d033","article-title":"Surgical management of descending thoracic aortic disease: open and endovascular approaches: a scientific statement from the American Heart Association","volume":"121","year":"2010","unstructured":"Coady\n              MA,\n            \n            \n              Ikonomidis\n              JS,\n            \n            \n              Cheung\n              AT,\n            \n            ;\n\t\t\t\t\t\tAmerican Heart Association Council on Cardiovascular Surgery and Anesthesia and Council on Peripheral Vascular Disease.\n          Surgical management of descending thoracic aortic disease: open and endovascular approaches: a scientific statement from the American Heart Association.\n\t\t\t\t\tCirculation.2010;121(25):2780\u20132804.\n\t\t\t\t\tdoi:10.1161\/CIR.0b013e3181e4d033"},{"issue":"3","key":"i1526-6702-50-2-e227850-b4","series-title":"J Vasc Surg.","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1016\/j.jvs.2008.12.068","article-title":"Failure modes of thoracic endografts: prevention and management","volume":"49","year":"2009","unstructured":"Lee\n              WA.\n            \n          \n          Failure modes of thoracic endografts: prevention and management.\n\t\t\t\t\tJ Vasc Surg.2009;49(3):792\u2013799.\n\t\t\t\t\tdoi:10.1016\/j.jvs.2008.12.068"},{"issue":"4","key":"i1526-6702-50-2-e227850-b5","series-title":"J Vasc Surg.","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.jvs.2021.04.018","article-title":"A preliminary analysis of late structural failures of the Navion stent graft in the treatment of descending thoracic aortic aneurysms","volume":"74","year":"2021","unstructured":"Verzini\n              F,\n            \n            \n              Cieri\n              E,\n            \n            \n              Kahlberg\n              A,\n            \n          \n          .\n\t\t\t\t\tA preliminary analysis of late structural failures of the Navion stent graft in the treatment of descending thoracic aortic aneurysms.\n\t\t\t\t\tJ Vasc Surg.2021;74(4):1125\u20131134.e2doi:10.1016\/j.jvs.2021.04.018"},{"issue":"2","key":"i1526-6702-50-2-e227850-b6","series-title":"J Vasc Surg.","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/j.jvs.2021.01.047","article-title":"Clinical trial outcomes and thoracic aorta morphometry after one year with the Valiant Navion stent graft system","volume":"74","year":"2021","unstructured":"Verzini\n              F,\n            \n            \n              Desai\n              N,\n            \n            \n              Arko\n              FR\n              III,\n            \n          \n          .\n\t\t\t\t\tClinical trial outcomes and thoracic aorta morphometry after one year with the Valiant Navion stent graft system.\n\t\t\t\t\tJ Vasc Surg.2021;74(2):569\u2013578.e3doi:10.1016\/j.jvs.2021.01.047"},{"issue":"5","key":"i1526-6702-50-2-e227850-b7","series-title":"Ann Thorac Surg.","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.1016\/j.athoracsur.2021.05.054","article-title":"Five-year outcomes with conformable GORE TAG endoprosthesis used in traumatic aortic transections","volume":"113","year":"2022","unstructured":"Farber\n              MA,\n            \n            \n              Krishnasastry\n              KV,\n            \n            \n              Desai\n              N,\n            \n            \n              Starnes\n              BW,\n            \n            \n              Matsumura\n              JS,\n            \n            \n              Tohill\n              BC;\n            \n            TAG 08-02 Clinical Trial Investigators.\n          \n          Five-year outcomes with conformable GORE TAG endoprosthesis used in traumatic aortic transections.\n\t\t\t\t\tAnn Thorac Surg.2022;113(5):1536\u20131542.\n\t\t\t\t\tdoi:10.1016\/j.athoracsur.2021.05.054"},{"issue":"5","key":"i1526-6702-50-2-e227850-b8","series-title":"J Vasc Surg.","doi-asserted-by":"publisher","first-page":"1491","DOI":"10.1016\/j.jvs.2021.04.063","article-title":"Long-term outcomes of the conformable TAG thoracic endoprosthesis in a prospective multicenter trial","volume":"74","year":"2021","unstructured":"Jordan\n              WD,\n            \n            \n              Desai\n              N,\n            \n            \n              Letter\n              AJ,\n            \n            \n              Matsumura\n              JS.\n            \n          \n          Long-term outcomes of the conformable TAG thoracic endoprosthesis in a prospective multicenter trial.\n\t\t\t\t\tJ Vasc Surg.2021;74(5):1491\u20131498.\n\t\t\t\t\tdoi:10.1016\/j.jvs.2021.04.063"},{"issue":"3 suppl","key":"i1526-6702-50-2-e227850-b9","series-title":"J Thorac Cardiovasc Surg.","doi-asserted-by":"publisher","first-page":"S165","DOI":"10.1016\/j.jtcvs.2012.11.046","article-title":"Reintervention for endograft failures after thoracic endovascular aortic repair","volume":"145","year":"2013","unstructured":"Szeto\n              WY,\n            \n            \n              Desai\n              ND,\n            \n            \n              Moeller\n              P,\n            \n          \n          .\n\t\t\t\t\tReintervention for endograft failures after thoracic endovascular aortic repair.\n\t\t\t\t\tJ Thorac Cardiovasc Surg.2013;145(3 suppl):S165\u2013S170.\n\t\t\t\t\tdoi:10.1016\/j.jtcvs.2012.11.046"}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/50\/2\/article-e227850.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/thij\/article-pdf\/doi\/10.14503\/THIJ-22-7850\/3413900\/i1526-6702-50-2-e227850.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/50\/2\/article-e227850.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/50\/2\/article-e227850.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:33:20Z","timestamp":1730993600000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/50\/2\/article-e227850.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,1]]},"references-count":9,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.14503\/thij-22-7850","relation":{},"ISSN":["1526-6702","0730-2347"],"issn-type":[{"type":"electronic","value":"1526-6702"},{"type":"print","value":"0730-2347"}],"subject":[],"published":{"date-parts":[[2023,3,1]]}}}