{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T16:10:09Z","timestamp":1730995809084,"version":"3.28.0"},"reference-count":12,"publisher":"Texas Heart Institute Journal","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>Transcatheter aortic valve replacement is quickly becoming the standard of care for patients with severe aortic stenosis thanks to its minimally invasive nature and favorable outcomes. Recently, left ventricular pacing has been proposed as a safer alternative to traditional right heart pacing, which could simplify the transcatheter aortic valve replacement procedure overall, although procedural complications may still occur. This report describes a rare case of left ventricular pacing wire\u2013induced acute severe mitral valve regurgitation during transcatheter aortic valve replacement.<\/jats:p>","DOI":"10.14503\/thij-23-8215","type":"journal-article","created":{"date-parts":[[2024,4,29]],"date-time":"2024-04-29T06:15:50Z","timestamp":1714371350000},"source":"Crossref","is-referenced-by-count":0,"title":["Acute Mitral Valve Regurgitation Caused by Left Ventricular Pacing Wire During Transcatheter Aortic Valve Replacement"],"prefix":"10.14503","volume":"51","author":[{"given":"Byeng-Ju","family":"Son","sequence":"first","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ung","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong-Ho","family":"Nam","sequence":"additional","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kang-Un","family":"Choi","sequence":"additional","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong-Il","family":"Park","sequence":"additional","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang-Won","family":"Son","sequence":"additional","affiliation":[{"name":"Division of Cardiology, College of Medicine, Yeungnam University Medical Center, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"17","key":"i1526-6702-51-1-e238215-b1","series-title":"N Engl J Med","first-page":"1597","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.","volume":"363","author":"Leon\n              MB","year":"2010","unstructured":"Leon\n              MB\n            , SmithCR, MackM, et al.\n          Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.\n          N Engl J Med. 2010;363(17):1597-1607. doi:10.1056\/NEJMoa1008232"},{"issue":"2","key":"i1526-6702-51-1-e238215-b2","series-title":"Catheter Cardiovasc Interv","first-page":"330","article-title":"Comparison of local versus general anesthesia in patients undergoing transcatheter aortic valve replacement: a meta-analysis.","volume":"91","author":"Villablanca\n              PA","year":"2018","unstructured":"Villablanca\n              PA\n            , MohananeyD, NikolicK, et al.\n          Comparison of local versus general anesthesia in patients undergoing transcatheter aortic valve replacement: a meta-analysis.\n          Catheter Cardiovasc Interv. 2018;91(2):330-342. doi:10.1002\/ccd.27207"},{"key":"i1526-6702-51-1-e238215-b3","series-title":"Int J Cardiol","first-page":"46","article-title":"Comparison of left ventricular with right ventricular rapid pacing on tamponade during TAVI.","volume":"360","author":"Savvoulidis\n              P","year":"2022","unstructured":"Savvoulidis\n              P\n            , MecheryA, LawtonE, et al.\n          Comparison of left ventricular with right ventricular rapid pacing on tamponade during TAVI.\n          Int J Cardiol. 2022;360:46-52. doi:10.1016\/j.ijcard.2022.05.035"},{"issue":"6","key":"i1526-6702-51-1-e238215-b4","series-title":"Structural Heart","first-page":"478","article-title":"Routine left ventricular pacing for patients undergoing transcatheter aortic valve replacement.","volume":"3","author":"Scarsini\n              R","year":"2019","unstructured":"Scarsini\n              R\n            , KotroniasRA, De MariaGL, et al.\n          Routine left ventricular pacing for patients undergoing transcatheter aortic valve replacement.\n          Structural Heart. 2019;3(6):478-482. doi:10.1080\/24748706.2019.1649771"},{"issue":"3","key":"i1526-6702-51-1-e238215-b5","series-title":"JACC Cardiovasc Imaging","first-page":"288","article-title":"Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement.","volume":"8","author":"Hahn\n              RT","year":"2015","unstructured":"Hahn\n              RT\n            , KodaliS, TuzcuEM, et al.\n          Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement.\n          JACC Cardiovasc Imaging. 2015;8(3):288-318. doi:10.1016\/j.jcmg.2014.12.013"},{"issue":"9","key":"i1526-6702-51-1-e238215-b6","series-title":"JACC Cardiovasc Interv","first-page":"811","article-title":"Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.","volume":"2","author":"Masson\n              JB","year":"2009","unstructured":"Masson\n              JB\n            , KovacJ, SchulerG, et al.\n          Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.\n          JACC Cardiovasc Interv. 2009;2(9):811-820. doi:10.1016\/j.jcin.2009.07.005"},{"issue":"4","key":"i1526-6702-51-1-e238215-b7","series-title":"Circ Cardiovasc Interv","first-page":"602","article-title":"Clinical outcomes and safety of transfemoral aortic valve implantation under general versus local anesthesia: subanalysis of the French Aortic National CoreValve and Edwards 2 registry.","volume":"7","author":"Oguri\n              A","year":"2014","unstructured":"Oguri\n              A\n            , YamamotoM, MouilletG, et al.\n          Clinical outcomes and safety of transfemoral aortic valve implantation under general versus local anesthesia: subanalysis of the French Aortic National CoreValve and Edwards 2 registry.\n          Circ Cardiovasc Interv. 2014;7(4):602-610. doi:10.1161\/CIRCINTERVENTIONS.113.000403"},{"issue":"11","key":"i1526-6702-51-1-e238215-b8","series-title":"Am J Cardiol","first-page":"1712","article-title":"Local versus general anesthesia in transcatheter aortic valve replacement.","volume":"118","author":"Jabbar\n              A","year":"2016","unstructured":"Jabbar\n              A\n            , KhuranaA, MohammedA, DasR, ZamanA, EdwardsR.\n          Local versus general anesthesia in transcatheter aortic valve replacement.\n          Am J Cardiol. 2016;118(11):1712-1716. doi:10.1016\/j.amjcard.2016.08.051"},{"issue":"11","key":"i1526-6702-51-1-e238215-b9","series-title":"J Invasive Cardiol","first-page":"603","article-title":"Mitral regurgitation during transcatheter aortic valve implantation: the same complication with a different mechanism.","volume":"26","author":"L\u00f3pez-Aguilera\n              J","year":"2014","unstructured":"L\u00f3pez-Aguilera\n              J\n            , Mesa-RubioD, Ruiz-OrtizM, et al.\n          Mitral regurgitation during transcatheter aortic valve implantation: the same complication with a different mechanism.\n          J Invasive Cardiol. 2014;26(11):603-608."},{"issue":"3","key":"i1526-6702-51-1-e238215-b10","series-title":"Echocardiography","first-page":"353","article-title":"Echocardiographic parameters predicting acute hemodynamically significant mitral regurgitation during transfemoral transcatheter aortic valve replacement.","volume":"35","author":"Ito\n              A","year":"2018","unstructured":"Ito\n              A\n            , IwataS, MizutaniK, et al.\n          Echocardiographic parameters predicting acute hemodynamically significant mitral regurgitation during transfemoral transcatheter aortic valve replacement.\n          Echocardiography. 2018;35(3):353-360. doi:10.1111\/echo.13792"},{"issue":"4","key":"i1526-6702-51-1-e238215-b11","series-title":"Catheter Cardiovasc Interv","first-page":"783","article-title":"Rapid pacing using the 0.035-in. retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty.","volume":"89","author":"SmithR","year":"2017","unstructured":"Hilling-SmithR, CockburnJ, DooleyM, et al.\n          Rapid pacing using the 0.035-in. retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty.\n          Catheter Cardiovasc Interv. 2017;89(4):783-786. doi:10.1002\/ccd.26720"},{"issue":"1","key":"i1526-6702-51-1-e238215-b12","series-title":"J Cardiothorac Vasc Anesth","first-page":"229","article-title":"CASE 1-2016 problem-solving in transcatheter aortic valve replacement: cardiovascular collapse, myocardial stunning, and mitral regurgitation.","volume":"30","author":"Fabbro\n              M","year":"2016","unstructured":"Fabbro\n              M\n            , GoldhammerJ, AugoustidesJG, et al.\n          CASE 1-2016 problem-solving in transcatheter aortic valve replacement: cardiovascular collapse, myocardial stunning, and mitral regurgitation.\n          J Cardiothorac Vasc Anesth. 2016;30(1):229-236. doi:10.1053\/j.jvca.2015.03.015"}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/51\/1\/article-e238215.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/thij\/article-pdf\/doi\/10.14503\/THIJ-23-8215\/3411039\/i1526-6702-51-1-e238215.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/51\/1\/article-e238215.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/51\/1\/article-e238215.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:38:48Z","timestamp":1730993928000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/51\/1\/article-e238215.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":12,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.14503\/thij-23-8215","relation":{},"ISSN":["1526-6702","0730-2347"],"issn-type":[{"type":"electronic","value":"1526-6702"},{"type":"print","value":"0730-2347"}],"subject":[],"published":{"date-parts":[[2024]]}}}