{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T16:10:03Z","timestamp":1730995803869,"version":"3.28.0"},"reference-count":11,"publisher":"Texas Heart Institute Journal","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.<\/jats:p>","DOI":"10.14503\/thij-23-8268","type":"journal-article","created":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T15:57:25Z","timestamp":1712073445000},"source":"Crossref","is-referenced-by-count":0,"title":["Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation"],"prefix":"10.14503","volume":"51","author":[{"given":"Salim N.","family":"Najjar","sequence":"first","affiliation":[{"name":"Department of Medicine, Baylor College of Medicine, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael A.","family":"Bruno","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Pediatric Cardiology, Baylor College of Medicine, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wilson W.","family":"Lam","sequence":"additional","affiliation":[{"name":"Department of Medicine, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Pediatrics, Division of Pediatric Cardiology, Baylor College of Medicine, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5628","reference":[{"issue":"37","key":"b1","series-title":"Eur Heart J","first-page":"2510","article-title":"Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study","volume":"36","author":"Ritter\n              P","year":"2015","unstructured":"Ritter\n              P\n            , DurayGZ, SteinwenderC, et al; Micra Transcatheter Pacing Study Group. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study. Eur Heart J. 2015;36(37):2510-2519. doi:10.1093\/eurheartj\/ehv214"},{"issue":"5","key":"b2","series-title":"Europace","first-page":"740","article-title":"European experience with a first totally leadless cardiac resynchronization therapy pacemaker system","volume":"23","author":"Carabelli\n              A","year":"2021","unstructured":"Carabelli\n              A\n            , JabeurM, JaconP, et al.\n          European experience with a first totally leadless cardiac resynchronization therapy pacemaker system. Europace. 2021;23(5):740-747. doi:10.1093\/europace\/euaa342"},{"issue":"2","key":"b3","series-title":"J Cardiovasc Electrophysiol","first-page":"477","article-title":"Incidence of pacing-induced cardiomyopathy in pacemaker-dependent patients is lower with leadless pacemakers compared to transvenous pacemakers","volume":"32","author":"Sanchez\n              R","year":"2021","unstructured":"Sanchez\n              R\n            , NadkarniA, BuckB, et al.\n          Incidence of pacing-induced cardiomyopathy in pacemaker-dependent patients is lower with leadless pacemakers compared to transvenous pacemakers. J Cardiovasc Electrophysiol. 2021;32(2):477-483. doi:10.1111\/jce.14814"},{"issue":"4","key":"b4","series-title":"Heart Rhythm","first-page":"492","article-title":"Right bundle branch pacing: criteria, characteristics, and outcomes","volume":"20","author":"Jastrz\u0119bski","year":"2023","unstructured":"Jastrz\u0119bski\n              M\n            , Kie\u0142basaG, MoskalP, et al.\n          Right bundle branch pacing: criteria, characteristics, and outcomes. Heart Rhythm. 2023;20(4):492-500. doi:10.1016\/j.hrthm.2023.01.017"},{"issue":"6","key":"b5","series-title":"Circ Arrhythm Electrophysiol","article-title":"Differentiating right- and left-sided outflow tract ventricular arrhythmias: classical ECG signatures and prediction algorithms","volume":"12","author":"Anderson\n              RD","year":"2019","unstructured":"Anderson\n              RD\n            , KumarS, ParameswaranR, et al.\n          Differentiating right- and left-sided outflow tract ventricular arrhythmias: classical ECG signatures and prediction algorithms. Circ Arrhythm Electrophysiol. 2019;12(6):e007392. doi:10.1161\/CIRCEP.119.007392"},{"key":"b6","series-title":"Front Physiol","first-page":"898866","article-title":"Leadless left bundle branch area pacing in cardiac resynchronisation therapy: advances, challenges and future directions","volume":"13","author":"Wijesuriya\n              N","year":"2022","unstructured":"Wijesuriya\n              N\n            , ElliottMK, MehtaV, et al.\n          Leadless left bundle branch area pacing in cardiac resynchronisation therapy: advances, challenges and future directions. Front Physiol. 2022;13:898866. doi:10.3389\/fphys.2022.898866"},{"issue":"5","key":"b7","series-title":"HeartRhythm Case Rep","first-page":"180","article-title":"Premature ventricular contraction\u2013induced polymorphic ventricular tachycardia after leadless pacemaker implantation: a unique adverse effect of leadless pacing","volume":"4","author":"Amin\n              AK","year":"2018","unstructured":"Amin\n              AK\n            , BillakantySR, ChopraN, et al.\n          Premature ventricular contraction\u2013induced polymorphic ventricular tachycardia after leadless pacemaker implantation: a unique adverse effect of leadless pacing. HeartRhythm Case Rep. 2018;4(5):180-183. doi:10.1016\/j.hrcr.2018.01.006"},{"issue":"1","key":"b8","series-title":"Cardiol Ther","first-page":"21","article-title":"Leadless cardiac pacing: new horizons","volume":"12","author":"Malaczynska-Rajpold\n              K","year":"2023","unstructured":"Malaczynska-Rajpold\n              K\n            , ElliotM, WijesuriyaN, et al.\n          Leadless cardiac pacing: new horizons. Cardiol Ther. 2023;12(1):21-33. doi:10.1007\/s40119-022-00288-0"},{"issue":"11","key":"b9","series-title":"Eur Heart J Case Rep","first-page":"ytab379","article-title":"Technical feasibility of leadless left bundle branch area pacing for cardiac resynchronization: a case series","volume":"5","author":"Elliott\n              MK","year":"2021","unstructured":"Elliott\n              MK\n            , JaconP, SidhuBS, et al.\n          Technical feasibility of leadless left bundle branch area pacing for cardiac resynchronization: a case series. Eur Heart J Case Rep. 2021;5(11):ytab379. doi:10.1093\/ehjcr\/ytab379"},{"issue":"11","key":"b10","series-title":"Heart Rhythm","first-page":"2265","article-title":"Thrombus formation at the tip of a leadless pacemaker causing multiple unnecessary repositioning","volume":"13","author":"Arias\n              MA","year":"2016","unstructured":"Arias\n              MA\n            , RubioMA, de MiguelR, Pach\u00f3nM. Thrombus formation at the tip of a leadless pacemaker causing multiple unnecessary repositioning. Heart Rhythm. 2016;13(11):2265. doi:10.1016\/j.hrthm.2016.07.006"},{"key":"b11","series-title":"Translation Research Anat","first-page":"100232","article-title":"Anatomical variations and clinical significance of atrioventricular bundle of His: a concise literature review","volume":"30","author":"Balawender\n              K","year":"2023","unstructured":"Balawender\n              K\n            , K\u0142osowiczM, InglotJ, et al.\n          Anatomical variations and clinical significance of atrioventricular bundle of His: a concise literature review. Translation Research Anat. 2023;30:100232. doi:10.1016\/j.tria.2023.100232"}],"container-title":["Texas Heart Institute Journal"],"original-title":[],"link":[{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/51\/1\/article-e238268.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/thij\/article-pdf\/doi\/10.14503\/THIJ-23-8268\/3411070\/i1526-6702-51-1-e238268.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/51\/1\/article-e238268.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thij.kglmeridian.com\/downloadpdf\/journals\/thij\/51\/1\/article-e238268.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T15:38:49Z","timestamp":1730993929000},"score":1,"resource":{"primary":{"URL":"https:\/\/thij.kglmeridian.com\/view\/journals\/thij\/51\/1\/article-e238268.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":11,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.14503\/thij-23-8268","relation":{},"ISSN":["1526-6702","0730-2347"],"issn-type":[{"type":"electronic","value":"1526-6702"},{"type":"print","value":"0730-2347"}],"subject":[],"published":{"date-parts":[[2024]]}}}