{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T17:45:27Z","timestamp":1789062327799,"version":"build-2803163510"},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Rationale<\/jats:title>\n                    <jats:p>Technological advances have improved the ability of bronchoscopists to access peripheral pulmonary lesions for tissue sampling. Radial probe endobronchial ultrasound (EBUS) provides real-time feedback to guide biopsies of peripheral lesions, thereby potentially improving diagnostic yield over conventional bronchoscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>We assessed the overall diagnostic yield of peripheral bronchoscopy using radial probe EBUS for peripheral pulmonary lesions, as well as factors that might influence the diagnostic yield, such as radial ultrasound view, lesion size, and ability to locate the peripheral lesion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a retrospective review of peripheral bronchoscopy cases in which radial probe EBUS was utilized to diagnose peripheral pulmonary lesions at a tertiary care university hospital.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Measurements and Main Results<\/jats:title>\n                    <jats:p>Our study cohort comprised 496 patients who underwent bronchoscopies between January 2008 and December 2012 for the diagnosis of peripheral pulmonary lesions. Radial probe EBUS was used alone for diagnostic purposes in 467 patients. A diagnosis was made on that basis in 321 (69%) of 467 patients. A diagnosis was obtained for 83 of 144 (58%) of nodules 1\u20132 cm in diameter, 99 of 137 (72%) of nodules 2.1\u20133 cm, 54 of 70 (77%) of nodules 3.1\u20134 cm, 41 of 47 (87%) of nodules 4.1\u20135 cm, and 35 of 40 (88%) of nodules larger than 5.1 cm. Of all 467 nodules, 446 (96%) were successfully identified using radial probe EBUS. When the radial probe position was within the target lesion, the diagnostic yield was 84% compared with 48% when the probe was positioned adjacent to the lesion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Radial probe EBUS can be used to guide biopsy during peripheral bronchoscopy. This technique provides real-time ultrasound-based confirmation of target lesion localization prior to biopsy. Using radial probe EBUS, the vast majority of peripheral pulmonary nodules can be identified. Radial EBUS probe position relative to the target lesion significantly affects the diagnostic yield.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1513\/annalsats.201311-384oc","type":"journal-article","created":{"date-parts":[[2014,3,17]],"date-time":"2014-03-17T12:52:33Z","timestamp":1395060753000},"page":"578-582","source":"Crossref","is-referenced-by-count":142,"title":["Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional Experience"],"prefix":"10.1093","volume":"11","author":[{"given":"Alexander","family":"Chen","sequence":"first","affiliation":[{"name":"Division of Pulmonary and Critical Care, Washington University School of Medicine, St. Louis, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Praveen","family":"Chenna","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care, Washington University School of Medicine, St. Louis, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Loiselle","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care, Washington University School of Medicine, St. Louis, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Massoni","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care, Washington University School of Medicine, St. Louis, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Mayse","sequence":"additional","affiliation":[{"name":"Holaira, Inc., Minneapolis, Minnesota; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Misselhorn","sequence":"additional","affiliation":[{"name":"Department of Respiratory Care Services, Barnes-Jewish Hospital, St. Louis, Missouri"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2014,5,1]]},"reference":[{"key":"2026012303531035300_bib1","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1378\/chest.117.4.1049","article-title":"Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules","volume":"117","author":"Baaklini","year":"2000","journal-title":"Chest"},{"key":"2026012303531035300_bib2","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1164\/rccm.200603-344OC","article-title":"Electromagnetic navigation diagnostic bronchoscopy: a prospective study","volume":"174","author":"Gildea","year":"2006","journal-title":"Am J Respir Crit Care Med"},{"key":"2026012303531035300_bib3","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1378\/chest.06-3016","article-title":"Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions","volume":"131","author":"Eberhardt","year":"2007","journal-title":"Chest"},{"key":"2026012303531035300_bib4","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1111\/resp.12095","article-title":"Diagnostic yield of combined bronchoscopy and endobronchial ultrasonography, under LungPoint guidance for small peripheral pulmonary lesions","volume":"18","author":"Tamiya","year":"2013","journal-title":"Respirology"},{"key":"2026012303531035300_bib5","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1183\/09031936.04.00138603","article-title":"Endobronchial ultrasonography with guide-sheath for peripheral pulmonary lesions","volume":"24","author":"Kikuchi","year":"2004","journal-title":"Eur Respir J"},{"key":"2026012303531035300_bib6","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1378\/chest.07-0637","article-title":"Factors related to diagnostic yield of transbronchial biopsy using endobronchial ultrasonography with a guide sheath in small peripheral pulmonary lesions","volume":"132","author":"Yamada","year":"2007","journal-title":"Chest"},{"key":"2026012303531035300_bib7","doi-asserted-by":"crossref","first-page":"1788","DOI":"10.1378\/chest.06-2506","article-title":"Diagnostic value of endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions without X-ray fluoroscopy","volume":"131","author":"Yoshikawa","year":"2007","journal-title":"Chest"},{"key":"2026012303531035300_bib8","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1378\/chest.126.3.959","article-title":"Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically","volume":"126","author":"Kurimoto","year":"2004","journal-title":"Chest"},{"key":"2026012303531035300_bib9","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/JTO.0b013e3182417e60","article-title":"Randomized study of endobronchial ultrasound-guided transbronchial biopsy: thin bronchoscopic method versus guide sheath method","volume":"7","author":"Oki","year":"2012","journal-title":"J Thorac Oncol"},{"key":"2026012303531035300_bib10","author":"Chen","year":"2013"},{"key":"2026012303531035300_bib11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1164\/rccm.200612-1866OC","article-title":"Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial","volume":"176","author":"Eberhardt","year":"2007","journal-title":"Am J Respir Crit Care Med"},{"key":"2026012303531035300_bib12","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1183\/09031936.00075310","article-title":"Radial probe endobronchial ultrasound for the diagnosis of peripheral lung cancer: systematic review and meta-analysis","volume":"37","author":"Steinfort","year":"2011","journal-title":"Eur Respir J"},{"key":"2026012303531035300_bib13","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1183\/09031936.00166708","article-title":"Ultrasound-guided transbronchial biopsy of solitary pulmonary nodules less than 20 mm","volume":"34","author":"Eberhardt","year":"2009","journal-title":"Eur Respir J"},{"key":"2026012303531035300_bib14","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.crad.2007.09.003","article-title":"CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less","volume":"63","author":"Ng","year":"2008","journal-title":"Clin Radiol"},{"key":"2026012303531035300_bib15","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1148\/radiology.217.3.r00dc21685","article-title":"US-guided transthoracic cutting biopsy for peripheral thoracic lesions less than 3 cm in diameter","volume":"217","author":"Liao","year":"2000","journal-title":"Radiology"},{"key":"2026012303531035300_bib16","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2291020499","article-title":"CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate","volume":"229","author":"Geraghty","year":"2003","journal-title":"Radiology"}],"container-title":["Annals of the American Thoracic Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/annalsats\/article-pdf\/11\/4\/578\/66485070\/annalsats_11_4_578.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/annalsats\/article-pdf\/11\/4\/578\/66485070\/annalsats_11_4_578.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T08:53:27Z","timestamp":1769158407000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/annalsats\/article\/11\/4\/578\/8431977"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,1]]},"references-count":16,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2014,5,1]]},"published-print":{"date-parts":[[2014,5,1]]}},"URL":"https:\/\/doi.org\/10.1513\/annalsats.201311-384oc","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.718319735.793492568","asserted-by":"object"}]},"ISSN":["2329-6933","2325-6621"],"issn-type":[{"value":"2329-6933","type":"print"},{"value":"2325-6621","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2014,5]]},"published":{"date-parts":[[2014,5,1]]}}}