{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T09:14:26Z","timestamp":1766222066711,"version":"3.48.0"},"reference-count":25,"publisher":"Walter de Gruyter GmbH","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,11,24]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study proposes a distribution line fault detection and location technology based on waveform comparison, aiming to improve fault detection accuracy and shorten analysis time. This technology collects current data at multiple measurement points on the line and transmits the data to the central system for feature extraction and waveform analysis. When a fault occurs, the correlation coefficient between waveforms is used as a similarity criterion for comparison, to determine the fault and locate it automatically. By establishing a simulation model of the distribution network, single-phase grounding, three-phase grounding, and short-circuit faults are simulated. Experimental results show that under complex working conditions, this technology has a low false alarm rate and high positioning accuracy. Especially in the simulation of conventional distribution networks, when the grounding resistance is low, the waveform correlation coefficient is high, and the fault point can be accurately located; in distributed power distribution networks, this technology can effectively detect and find a variety of faults.<\/jats:p>","DOI":"10.1515\/jisys-2024-0348","type":"journal-article","created":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T17:24:12Z","timestamp":1764005052000},"source":"Crossref","is-referenced-by-count":0,"title":["Power line fault detection based on waveform comparison offline location technology"],"prefix":"10.1515","volume":"34","author":[{"given":"Shengzhu","family":"Li","sequence":"first","affiliation":[{"name":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"}]},{"given":"Yulin","family":"Ge","sequence":"additional","affiliation":[{"name":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"}]},{"given":"Zhipeng","family":"Wang","sequence":"additional","affiliation":[{"name":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"}]},{"given":"Zejian","family":"Yun","sequence":"additional","affiliation":[{"name":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"}]},{"given":"Jianze","family":"Liu","sequence":"additional","affiliation":[{"name":"Beijing Dan Hua Hao Bo Power Science and Technology Co., Ltd , Beijing , 100085 , China"}]}],"member":"374","published-online":{"date-parts":[[2025,11,24]]},"reference":[{"key":"2025122009032182638_j_jisys-2024-0348_ref_001","unstructured":"Zhining Lv. Overview of common fault analysis and detection methods for transmission lines. Autom Instrum. 2020;(1):161\u20134. 10.14016\/j.cnki.1001-9227.2020.01.161."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_002","doi-asserted-by":"crossref","unstructured":"Mukherjee A, Kundu PK, Das A. Transmission line faults in power system and the different algorithms for identification, classification, and localization: a brief review of methods. J Inst Eng (India): Ser B. 2021;102(4):1\u201323. 10.1007\/s40031-020-00530-0.","DOI":"10.1007\/s40031-020-00530-0"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_003","doi-asserted-by":"crossref","unstructured":"Liang YL, Li KJ, Ma Z, Lee WJ. Typical fault causes recognition of single-phase-to-ground fault for overhead lines in nonsolidly earthed distribution networks. IEEE Trans Ind Appl. 2020;56(6):6298\u2013306. 10.1109\/TIA.2020.3020526.","DOI":"10.1109\/TIA.2020.3020526"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_004","doi-asserted-by":"crossref","unstructured":"Cong Z, Liu Y, Fang J, Wang P, Guo L, Jiang X. Root-cause identification of single line-to-ground fault in urban small current grounding systems based on correlation dimension and average resistance. IEEE Trans Power Delivery. 2019;35(4):1834\u201343. 10.1109\/TPWRD.2019.2955185.","DOI":"10.1109\/TPWRD.2019.2955185"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_005","doi-asserted-by":"crossref","unstructured":"Gangolu S, Raja P, Selvan MP, Kirthiga Murali V. An effective algorithm for fault discrimination and estimation of fault location in transmission lines. IET Gener Transm Distrib. 2019;13(13):2789\u201398. 10.1049\/iet-gtd.2018.5815.","DOI":"10.1049\/iet-gtd.2018.5815"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_006","doi-asserted-by":"crossref","unstructured":"Panahi H, Zamani R, Sanaye-Pasand M, Mehrjerdi H. Advances in transmission network fault location in modern power systems: review, outlook and future works. IEEE Access. 2021;9:158599\u2013615. 10.1109\/ACCESS.2021.3129838.","DOI":"10.1109\/ACCESS.2021.3129838"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_007","doi-asserted-by":"crossref","unstructured":"Ehsan A, Yang Q. State-of-the-art techniques for modeling of uncertainties in active distribution network planning: A review. Appl Energy. 2019;239:1509\u201323. 10.1016\/j.apenergy.2019.01.211.","DOI":"10.1016\/j.apenergy.2019.01.211"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_008","doi-asserted-by":"crossref","unstructured":"Ali SS, Choi BJ. State-of-the-art artificial intelligence techniques for distributed smart grids: A review. Electronics. 2020;9(6):1030. 10.3390\/electronics9061030.","DOI":"10.3390\/electronics9061030"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_009","doi-asserted-by":"crossref","unstructured":"Wong SY, Choe CWC, Goh HH, Low YW, Cheah DYS, Pang C. Power transmission line fault detection and diagnosis based on artificial intelligence approach and its development in UAV: A review. Arab J Sci Eng. 2021;46(10):9305\u201331. 10.1007\/s13369-021-05522-w.","DOI":"10.1007\/s13369-021-05522-w"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_010","doi-asserted-by":"crossref","unstructured":"Wang S, Dehghanian P. On the use of artificial intelligence for high impedance fault detection and electrical safety. IEEE Trans Ind Appl. 2020;56(6):7208\u201316. 10.1109\/TIA.2020.3017698.","DOI":"10.1109\/TIA.2020.3017698"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_011","doi-asserted-by":"crossref","unstructured":"Ngo MK, Mai MVC, Huynh QC, Nguyen TTH. Performance comparison of impedance-based fault location methods for the transmission line. Int J Electr Electron Eng Telecommun. 2022;11(3):234\u201341. 10.18178\/ijeetc.11.3.234-241.","DOI":"10.18178\/ijeetc.11.3.234-241"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_012","doi-asserted-by":"crossref","unstructured":"Teimourzadeh H, Moradzadeh A, Shoaran M, Mohammadi-Ivatloo B, Razzaghi R. High impedance single-phase faults diagnosis in transmission lines via deep reinforcement learning of transfer functions. IEEE Access. 2021;9:15796\u2013809. 10.1109\/ACCESS.2021.3051411.","DOI":"10.1109\/ACCESS.2021.3051411"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_013","doi-asserted-by":"crossref","unstructured":"Cui Q, El-Arroudi K, Weng Y. A feature selection method for high impedance fault detection. IEEE Trans Power Delivery. 2019;34(3):1203\u201315. 10.1109\/TPWRD.2019.2901634.","DOI":"10.1109\/TPWRD.2019.2901634"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_014","doi-asserted-by":"crossref","unstructured":"Aftab MA, Hussain SMS, Ali I, Ustun TS. Dynamic protection of power systems with high penetration of renewables: A review of the traveling wave-based fault location techniques. Int J Electr Power Energy Syst. 2020;114:105410. 10.1016\/j.ijepes.2019.105410.","DOI":"10.1016\/j.ijepes.2019.105410"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_015","doi-asserted-by":"crossref","unstructured":"Xie L, Luo L, Li Y, Zhang Y, Cao Y. A traveling wave-based fault location method employing VMD-TEO for distribution network. IEEE Trans Power Delivery. 2019;35(4):1987\u201398. 10.1109\/TPWRD.2019.2959188.","DOI":"10.1109\/TPWRD.2019.2959188"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_016","doi-asserted-by":"crossref","unstructured":"Zhang C, Song G, Wang T, Yang L. Single-ended traveling wave fault location method in DC transmission line based on wavefront information. IEEE Trans Power Delivery. 2019;34(5):2028\u201338. 10.1109\/TPWRD.2019.2922654.","DOI":"10.1109\/TPWRD.2019.2922654"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_017","unstructured":"Wei WEI, Ciwei GAO, Meng SONG. Power line fault detection and classification system based on HHO-SVM. Integr Smart Energy. 2023;45(3):1\u20138. 10.3969\/j.issn.2097-0706.2023.03.001."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_018","doi-asserted-by":"crossref","unstructured":"Fahim SR, Sarker SK, Muyeen SM, Das SK, Kamwa I. A deep learning based intelligent approach in detection and classification of transmission line faults. Int J Electr Power Energy Syst. 2021;133:107102. 10.1016\/j.ijepes.2021.107102.","DOI":"10.1016\/j.ijepes.2021.107102"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_019","unstructured":"Yan S, Zhang WY, Li HZ, Wang L. Research on fast diagnosis methods for transmission line faults based on artificial intelligence. Power Syst Prot Control. 2019;47(19):94\u20139. 10.19783\/j.cnki.pspc.181527."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_020","unstructured":"Al-Shaikhli T, Ahmad B, Al-Taweel MH. The implementations and applications of Ampere\u2019s law to the theory of electromagnetic fields. Int J Adv Sci Technol. 2019;28(8):515\u201325."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_021","doi-asserted-by":"crossref","unstructured":"Crescentini M, Syeda SF, Gibiino GP. Hall-effect current sensors: Principles of operation and implementation techniques. IEEE Sens J. 2021;22(11):10137\u201351. 10.1109\/JSEN.2021.3119766.","DOI":"10.1109\/JSEN.2021.3119766"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_022","unstructured":"Wenjuan Z, Feige Z. Design of current detection system based on Hall sensor. Neijiang Technol. 2019;(3):56\u20137."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_023","doi-asserted-by":"crossref","unstructured":"Abdelkader R, Cherif BDE, Bendiabdellah A, Kaddour A. An open-circuit faults diagnosis approach for three-phase inverters based on an improved variational mode decomposition, correlation coefficients, and statistical indicators. IEEE Trans Instrum Meas. 2022;71:1\u20139. 10.1109\/TIM.2022.3149339.","DOI":"10.1109\/TIM.2022.3149339"},{"key":"2025122009032182638_j_jisys-2024-0348_ref_024","unstructured":"Seeram E. An overview of correlational research. Radiol Technol. 2019;91(2):176\u20139."},{"key":"2025122009032182638_j_jisys-2024-0348_ref_025","doi-asserted-by":"crossref","unstructured":"Li R, Wang W, Chen Z, Jiang J, Zhang W. A review of optimal planning active distribution system: Models, methods, and future researches. Energies. 2017;10(11):1715. 10.3390\/en10111715.","DOI":"10.3390\/en10111715"}],"container-title":["Journal of Intelligent Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/jisys-2024-0348\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/jisys-2024-0348\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T09:09:52Z","timestamp":1766221792000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/jisys-2024-0348\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,1]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,3,7]]},"published-print":{"date-parts":[[2025,3,7]]}},"alternative-id":["10.1515\/jisys-2024-0348"],"URL":"https:\/\/doi.org\/10.1515\/jisys-2024-0348","relation":{},"ISSN":["2191-026X"],"issn-type":[{"type":"electronic","value":"2191-026X"}],"subject":[],"published":{"date-parts":[[2025,1,1]]},"article-number":"20240348"}}