{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T22:58:22Z","timestamp":1780095502557,"version":"3.54.0"},"reference-count":56,"publisher":"Walter de Gruyter GmbH","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p>It is important to thoroughly remove the thrombus within the course of aspiration thrombectomy; otherwise, it may lead to further embolization. The performance of the aspiration thrombectomy device with a generic geometry is studied through the computational approach. In order to model the thrombus aspiration, a real left coronary artery is chosen while thrombi with various sizes are located at the bifurcation area of the coronary artery and, depending on the size of the thrombus, it is stretched toward the side branches. The thrombus occupies the artery resembling the blood current obstruction in the coronary vessel similar to the situation that leads to heart attack. It is concluded that the aspiration ability of the thrombectomy device is not linked to the thrombus size; it is rather linked to the aspiration pressure and thrombus age (organized versus fresh thrombus). However, the aspiration time period correlates to the thrombus size. The minimum applicable aspiration pressure is also investigated in this study.<\/jats:p>","DOI":"10.1515\/bmt-2014-0013","type":"journal-article","created":{"date-parts":[[2015,9,10]],"date-time":"2015-09-10T10:13:34Z","timestamp":1441880014000},"page":"337-344","source":"Crossref","is-referenced-by-count":4,"title":["Performance of a thrombectomy device for aspiration of thrombus with various sizes based on a computational fluid dynamic modeling"],"prefix":"10.1515","volume":"61","author":[{"given":"Sajjad","family":"Soleimani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriele","family":"Dubini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giancarlo","family":"Pennati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","reference":[{"key":"ref461","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1056\/NEJMoa0804626","article-title":"Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease","volume":"360","year":"2009","journal-title":"N Engl J Med"},{"key":"ref101","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.jstrokecerebrovasdis.2008.11.011","article-title":"The \u201cGP\u201d mechanical thrombectomy device","volume":"18","year":"2009","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"ref91","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1148\/radiology.211.2.r99ma06433","article-title":"In vitro effectiveness study of three hydrodynamic thrombectomy devices","volume":"211","year":"1999","journal-title":"Radiology"},{"key":"ref381","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.jstrokecerebrovasdis.2008.11.011","article-title":"The \u201cGP\u201d mechanical thrombectomy device","volume":"18","year":"2009","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"ref191","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1093\/eurheartj\/ehi138","article-title":"Guidelines for percutaneous coronary interventions: the task force for percutaneous coronary interventions of the European society of cardiology","volume":"26","year":"2005","journal-title":"Eur Heart J"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"241","DOI":"10.3233\/BIR-1991-283-415","article-title":"Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel, Part 1: steady flows","volume":"28","year":"1991","journal-title":"Biorheology"},{"key":"ref161","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1002\/ccd.20184","article-title":"Improved performance of a new thrombus aspiracatheter: outcomes from in vitro experiments and case presentation","volume":"63","year":"2004","journal-title":"Catheter Cardio Inte"},{"key":"ref531","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.jcin.2011.03.009","article-title":"Clinical and angiographic predictors and prognostic value of failed thrombus aspiration in primary percutaneous coronary intervention","volume":"4","year":"2011","journal-title":"Cardiovasc Intervent"},{"key":"ref401","year":"2011","journal-title":"Applicability of the GP device to the circle of Willis arteries by using a mathematical model"},{"key":"ref441","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1002\/ccd.20184","article-title":"Improved performance of a new thrombus aspiracatheter: outcomes from in vitro experiments and case presentation","volume":"63","year":"2004","journal-title":"Catheter Cardio Inte"},{"key":"ref501","year":"2013","journal-title":"Coronary thrombus removal by means of aspiration catheter: a numerical and experimental fluid dynamic study (dissertation)"},{"key":"ref81","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1148\/radiol.2363041287","article-title":"Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing","volume":"236","year":"2005","journal-title":"Radiology"},{"key":"ref211","first-page":"254","volume-title":"Medical devices design in cardiovascular applications","year":"2013"},{"key":"ref421","year":"2010","journal-title":"Modelling and simulation of a thrombectomy probe applied to the middle cerebral artery by using the bond graph technique"},{"key":"ref491","first-page":"254","volume-title":"Medical devices design in cardiovascular applications","year":"2013"},{"key":"ref301","doi-asserted-by":"crossref","first-page":"241","DOI":"10.3233\/BIR-1991-283-415","article-title":"Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel, Part 1: steady flows","volume":"28","year":"1991","journal-title":"Biorheology"},{"key":"ref411","year":"2011","journal-title":"Analysis and design of a thrombectomy device by using simulation techniques"},{"key":"ref311","first-page":"229","article-title":"Use of thrombectomy devices in primary percutaneous coronary intervention: a systematic review and meta-analysis","volume":"163","year":"2011","journal-title":"Int J Cardiol"},{"key":"ref471","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1093\/eurheartj\/ehi138","article-title":"Guidelines for percutaneous coronary interventions: the task force for percutaneous coronary interventions of the European society of cardiology","volume":"26","year":"2005","journal-title":"Eur Heart J"},{"key":"ref391","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/j.1525-1594.2009.00770.x","article-title":"Numerical simulation of thrombus aspiration in two realistic models of catheter tips","volume":"34","year":"2010","journal-title":"Artif Organs"},{"key":"ref221","year":"2013","journal-title":"Coronary thrombus removal by means of aspiration catheter: a numerical and experimental fluid dynamic study (dissertation)"},{"key":"ref351","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.jbiomech.2003.09.016","article-title":"Non-Newtonian blood flow in human right coronary arteries: steady state simulations","volume":"37","year":"2004","journal-title":"J Biomech"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ejvs.2003.12.014","article-title":"Thrombectomy for acute internal carotid thrombosis: five thrombectomy devices compared","volume":"27","year":"2004","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref551","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1056\/NEJM199911043411901","article-title":"Long-term benefit of primary angioplasty as compared with thrombolytic therapy for acute myocardial infarction","volume":"341","year":"1999","journal-title":"N Engl J Med"},{"key":"ref151","first-page":"381","article-title":"An investigation into the performance of a new mechanical thrombectomy device using bond graph modeling: application to the extraction of blood thrombus in the middle cerebral artery","volume":"89","year":"2012","journal-title":"Simul Trans Soc Model Simul Int"},{"key":"ref541","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1161\/STROKEAHA.110.602102","article-title":"Visualization of thrombus lysis in a rat embolic stroke model: application to comparative lytic efficacy","volume":"42","year":"2011","journal-title":"Stroke"},{"key":"ref511","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1056\/NEJMoa0706416","article-title":"Thrombus aspiration during primary percutaneous coronary intervention","volume":"358","year":"2008","journal-title":"N Engl J Med"},{"key":"ref431","first-page":"381","article-title":"An investigation into the performance of a new mechanical thrombectomy device using bond graph modeling: application to the extraction of blood thrombus in the middle cerebral artery","volume":"89","year":"2012","journal-title":"Simul Trans Soc Model Simul Int"},{"key":"ref171","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.jacc.2008.05.051","article-title":"A meta-analysis of 17 randomized trials of a percutaneous coronary intervention-based strategy in patients with stable coronary artery disease","volume":"52","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"ref181","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1056\/NEJMoa0804626","article-title":"Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease","volume":"360","year":"2009","journal-title":"N Engl J Med"},{"key":"ref31","first-page":"229","article-title":"Use of thrombectomy devices in primary percutaneous coronary intervention: a systematic review and meta-analysis","volume":"163","year":"2011","journal-title":"Int J Cardiol"},{"key":"ref71","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.jbiomech.2003.09.016","article-title":"Non-Newtonian blood flow in human right coronary arteries: steady state simulations","volume":"37","year":"2004","journal-title":"J Biomech"},{"key":"ref121","year":"2011","journal-title":"Applicability of the GP device to the circle of Willis arteries by using a mathematical model"},{"key":"ref231","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1056\/NEJMoa0706416","article-title":"Thrombus aspiration during primary percutaneous coronary intervention","volume":"358","year":"2008","journal-title":"N Engl J Med"},{"key":"ref241","volume-title":"Thrombus formation in aneurysms: an experimental study, division of cardiovascular biomechanics","year":"2008"},{"key":"ref361","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1148\/radiol.2363041287","article-title":"Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing","volume":"236","year":"2005","journal-title":"Radiology"},{"key":"ref111","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/j.1525-1594.2009.00770.x","article-title":"Numerical simulation of thrombus aspiration in two realistic models of catheter tips","volume":"34","year":"2010","journal-title":"Artif Organs"},{"key":"ref481","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1111\/aor.12274","article-title":"Possible benefits of catheters with lateral hole on coronary thrombus aspiration: a computational study for different clot viscosity and vacuum pressure","volume":"38","year":"2014","journal-title":"Artif Organs"},{"key":"ref131","year":"2011","journal-title":"Analysis and design of a thrombectomy device by using simulation techniques"},{"key":"ref281","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s00234-011-0893-8","article-title":"Intravenous flat-detector CT angiography in acute ischemic stroke management","volume":"54","year":"2012","journal-title":"Interv Neuroradiol"},{"key":"ref41","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/S0003-4975(10)66351-5","article-title":"Saphenous vein autograf replacement of severe segmental coronary artery occlusion: operative technique","volume":"5","year":"1968","journal-title":"Ann Thoracic Surg"},{"key":"ref141","year":"2010","journal-title":"Modelling and simulation of a thrombectomy probe applied to the middle cerebral artery by using the bond graph technique"},{"key":"ref251","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.jcin.2011.03.009","article-title":"Clinical and angiographic predictors and prognostic value of failed thrombus aspiration in primary percutaneous coronary intervention","volume":"4","year":"2011","journal-title":"Cardiovasc Intervent"},{"key":"ref331","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1007\/s10554-009-9546-y","article-title":"3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: a feasibility study","volume":"26","year":"2010","journal-title":"Int J Cardiovasc Imaging"},{"key":"ref61","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1097\/00029330-200704010-00006","article-title":"Diver CE versus Guardwire plus for thrombectomy in patients with inferior myocardial infarction: a trial of aspiration of thrombus during primary angioplasty for inferior myocardial infarction","volume":"120","year":"2007","journal-title":"Chin Med J"},{"key":"ref371","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1148\/radiology.211.2.r99ma06433","article-title":"In vitro effectiveness study of three hydrodynamic thrombectomy devices","volume":"211","year":"1999","journal-title":"Radiology"},{"key":"ref01","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s00234-011-0893-8","article-title":"Intravenous flat-detector CT angiography in acute ischemic stroke management","volume":"54","year":"2012","journal-title":"Interv Neuroradiol"},{"key":"ref341","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1097\/00029330-200704010-00006","article-title":"Diver CE versus Guardwire plus for thrombectomy in patients with inferior myocardial infarction: a trial of aspiration of thrombus during primary angioplasty for inferior myocardial infarction","volume":"120","year":"2007","journal-title":"Chin Med J"},{"key":"ref321","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/S0003-4975(10)66351-5","article-title":"Saphenous vein autograf replacement of severe segmental coronary artery occlusion: operative technique","volume":"5","year":"1968","journal-title":"Ann Thoracic Surg"},{"key":"ref521","volume-title":"Thrombus formation in aneurysms: an experimental study, division of cardiovascular biomechanics","year":"2008"},{"key":"ref51","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1007\/s10554-009-9546-y","article-title":"3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: a feasibility study","volume":"26","year":"2010","journal-title":"Int J Cardiovasc Imaging"},{"key":"ref291","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ejvs.2003.12.014","article-title":"Thrombectomy for acute internal carotid thrombosis: five thrombectomy devices compared","volume":"27","year":"2004","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref451","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.jacc.2008.05.051","article-title":"A meta-analysis of 17 randomized trials of a percutaneous coronary intervention-based strategy in patients with stable coronary artery disease","volume":"52","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"ref271","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1056\/NEJM199911043411901","article-title":"Long-term benefit of primary angioplasty as compared with thrombolytic therapy for acute myocardial infarction","volume":"341","year":"1999","journal-title":"N Engl J Med"},{"key":"ref201","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1111\/aor.12274","article-title":"Possible benefits of catheters with lateral hole on coronary thrombus aspiration: a computational study for different clot viscosity and vacuum pressure","volume":"38","year":"2014","journal-title":"Artif Organs"},{"key":"ref261","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1161\/STROKEAHA.110.602102","article-title":"Visualization of thrombus lysis in a rat embolic stroke model: application to comparative lytic efficacy","volume":"42","year":"2011","journal-title":"Stroke"}],"container-title":["Biomedical Engineering \/ Biomedizinische Technik"],"original-title":[],"link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/bmte.2016.61.issue-3\/bmt-2014-0013\/bmt-2014-0013.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.degruyter.com\/view\/j\/bmte.2016.61.issue-3\/bmt-2014-0013\/bmt-2014-0013.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,27]],"date-time":"2021-02-27T20:05:41Z","timestamp":1614456341000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/bmt-2014-0013\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,1]]},"references-count":56,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1515\/bmt-2014-0013","relation":{},"ISSN":["1862-278X","0013-5585"],"issn-type":[{"value":"1862-278X","type":"electronic"},{"value":"0013-5585","type":"print"}],"subject":[],"published":{"date-parts":[[2016,6,1]]}}}